Dental implants: early versus standard two-stage loading (animal study)

Direct bone formation on the implant surface is a treatment goal in implant dentistry. It was always thought that a healing period of 3 months for the lower jaw and 5-6 months for the upper jaw was required for osseointegration to occur. Recent studies, however, show that with the early loading prot...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of oral implantology 2014-02, Vol.40 (1), p.84-92
Hauptverfasser: Rismanchian, Mansour, Bajoghli, Farshad, Gholamreza, Tabakhian, Razavi, Mohamad
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 92
container_issue 1
container_start_page 84
container_title The Journal of oral implantology
container_volume 40
creator Rismanchian, Mansour
Bajoghli, Farshad
Gholamreza, Tabakhian
Razavi, Mohamad
description Direct bone formation on the implant surface is a treatment goal in implant dentistry. It was always thought that a healing period of 3 months for the lower jaw and 5-6 months for the upper jaw was required for osseointegration to occur. Recent studies, however, show that with the early loading protocol, osseointegration is possible as well. The goal of this study was to evaluate clinical, histologic, and histomorphometric parameters of implants with early loading protocols and implants that did not undergo the early loading protocol. In this experimental study, the first to the fourth premolar teeth were extracted from the lower jaws of 3 dogs. After a healing period of 3 months, 12 BioHorizons internal implants 4.5 × 10.5 mm were placed in the mandible of the dogs. The implant stability quotient (ISQ) was recorded. After 3 weeks, half of the implants were exposed, and after recording ISQ, polycarbonate crowns were placed on them and occlusion was adjusted so that there was no contact in centric occlusion and no lateral movement with the opposing teeth. After 3 months, the ISQs were recorded for all the implants. Bleeding upon probing and pocket depths were measured for the early loading implants. All the implants were removed using a trephine bur, and cross-sections of 150 μm were prepared, from which the bone implant contact (BIC) and the type of bone around them were obtained. Statistical analysis was conducted with independent t test, paired t test, and repeated analysis of variance. The BIC for the early loaded group was 46.17% ± 12.89%, and for the unloaded group was 44.4% ± 10.45%. This difference was not statistically significant (P = .811). The ISQ for the implants in the early loaded group (before they were removed) was 71 ± 7.35 and that of the unloaded group was 66.75 ± 11.86 .These differences were statistically insignificant. With regard to the result of this study, and the fact that the 2 groups showed no statistically significant differences in a number of major aspects, such as BIC and ISQ, it seems possible to load implants with an earlier than usual protocol with no adverse effects on implant success. It is necessary, however, to follow certain protocols for this type of loading.
doi_str_mv 10.1563/AAID-JOI-D-10-00202
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1529932526</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1510090727</sourcerecordid><originalsourceid>FETCH-LOGICAL-c411t-79540e0a81f0b426d6bed88014623a09823de536dbb80eb597ff3a3b9ab12aa13</originalsourceid><addsrcrecordid>eNqNkb1OwzAURi0EouXnCZBQJJYyGO61YydhqxooRZW6wBw5tVOlSpNiJ6C-PQ4tDExM1rXO9-nah5ArhDsUkt-Px7OUvixmNKUIFIABOyJDFGFMkXN5TIaAEqhMIjYgZ86tPSKEwFMyYIxhKDAakmlq6lZVQbnZVqpu3UNglK12wYexrnOBa1WtldVB-9lQP6xMUDVKl_UqGKm63Pikazu9u70gJ4WqnLk8nOfk7enxdfJM54vpbDKe02WI2NIoESEYUDEWkIdMapkbHceAoWRcQRIzro3gUud5DCYXSVQUXPE8UTkypZCfk9G-d2ub9864NtuUbmkqv7xpOpehYEnCmWDyHygCJBCxyKM3f9B109naP6SnQukbZegpvqeWtnHOmiLbWv8FdpchZL2SrFeSeSVZ2l99K_Gp60N3l2-M_s38OOBfDTCFfQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1514693264</pqid></control><display><type>article</type><title>Dental implants: early versus standard two-stage loading (animal study)</title><source>MEDLINE</source><source>Allen Press Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>Rismanchian, Mansour ; Bajoghli, Farshad ; Gholamreza, Tabakhian ; Razavi, Mohamad</creator><creatorcontrib>Rismanchian, Mansour ; Bajoghli, Farshad ; Gholamreza, Tabakhian ; Razavi, Mohamad</creatorcontrib><description>Direct bone formation on the implant surface is a treatment goal in implant dentistry. It was always thought that a healing period of 3 months for the lower jaw and 5-6 months for the upper jaw was required for osseointegration to occur. Recent studies, however, show that with the early loading protocol, osseointegration is possible as well. The goal of this study was to evaluate clinical, histologic, and histomorphometric parameters of implants with early loading protocols and implants that did not undergo the early loading protocol. In this experimental study, the first to the fourth premolar teeth were extracted from the lower jaws of 3 dogs. After a healing period of 3 months, 12 BioHorizons internal implants 4.5 × 10.5 mm were placed in the mandible of the dogs. The implant stability quotient (ISQ) was recorded. After 3 weeks, half of the implants were exposed, and after recording ISQ, polycarbonate crowns were placed on them and occlusion was adjusted so that there was no contact in centric occlusion and no lateral movement with the opposing teeth. After 3 months, the ISQs were recorded for all the implants. Bleeding upon probing and pocket depths were measured for the early loading implants. All the implants were removed using a trephine bur, and cross-sections of 150 μm were prepared, from which the bone implant contact (BIC) and the type of bone around them were obtained. Statistical analysis was conducted with independent t test, paired t test, and repeated analysis of variance. The BIC for the early loaded group was 46.17% ± 12.89%, and for the unloaded group was 44.4% ± 10.45%. This difference was not statistically significant (P = .811). The ISQ for the implants in the early loaded group (before they were removed) was 71 ± 7.35 and that of the unloaded group was 66.75 ± 11.86 .These differences were statistically insignificant. With regard to the result of this study, and the fact that the 2 groups showed no statistically significant differences in a number of major aspects, such as BIC and ISQ, it seems possible to load implants with an earlier than usual protocol with no adverse effects on implant success. It is necessary, however, to follow certain protocols for this type of loading.</description><identifier>ISSN: 0160-6972</identifier><identifier>EISSN: 1548-1336</identifier><identifier>DOI: 10.1563/AAID-JOI-D-10-00202</identifier><identifier>PMID: 22214517</identifier><language>eng</language><publisher>United States: Allen Press Inc</publisher><subject>Animals ; Connective Tissue - pathology ; Crowns ; Dental Implant-Abutment Design ; Dental Implantation, Endosseous - methods ; Dental Implants ; Dental Materials - chemistry ; Dental Prosthesis Retention ; Dental Prosthesis, Implant-Supported ; Dentistry ; Dogs ; Immediate Dental Implant Loading - methods ; Mandible - pathology ; Mandible - surgery ; Models, Animal ; Osseointegration - physiology ; Periodontal Index ; Periodontal Pocket - classification ; Polycarboxylate Cement - chemistry ; Prostheses ; Studies ; Success ; Surface Properties ; Surgery ; Teeth ; Time Factors ; Tooth Extraction ; Transplants &amp; implants</subject><ispartof>The Journal of oral implantology, 2014-02, Vol.40 (1), p.84-92</ispartof><rights>Copyright Allen Press Publishing Services 2014</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c411t-79540e0a81f0b426d6bed88014623a09823de536dbb80eb597ff3a3b9ab12aa13</citedby><cites>FETCH-LOGICAL-c411t-79540e0a81f0b426d6bed88014623a09823de536dbb80eb597ff3a3b9ab12aa13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/22214517$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Rismanchian, Mansour</creatorcontrib><creatorcontrib>Bajoghli, Farshad</creatorcontrib><creatorcontrib>Gholamreza, Tabakhian</creatorcontrib><creatorcontrib>Razavi, Mohamad</creatorcontrib><title>Dental implants: early versus standard two-stage loading (animal study)</title><title>The Journal of oral implantology</title><addtitle>J Oral Implantol</addtitle><description>Direct bone formation on the implant surface is a treatment goal in implant dentistry. It was always thought that a healing period of 3 months for the lower jaw and 5-6 months for the upper jaw was required for osseointegration to occur. Recent studies, however, show that with the early loading protocol, osseointegration is possible as well. The goal of this study was to evaluate clinical, histologic, and histomorphometric parameters of implants with early loading protocols and implants that did not undergo the early loading protocol. In this experimental study, the first to the fourth premolar teeth were extracted from the lower jaws of 3 dogs. After a healing period of 3 months, 12 BioHorizons internal implants 4.5 × 10.5 mm were placed in the mandible of the dogs. The implant stability quotient (ISQ) was recorded. After 3 weeks, half of the implants were exposed, and after recording ISQ, polycarbonate crowns were placed on them and occlusion was adjusted so that there was no contact in centric occlusion and no lateral movement with the opposing teeth. After 3 months, the ISQs were recorded for all the implants. Bleeding upon probing and pocket depths were measured for the early loading implants. All the implants were removed using a trephine bur, and cross-sections of 150 μm were prepared, from which the bone implant contact (BIC) and the type of bone around them were obtained. Statistical analysis was conducted with independent t test, paired t test, and repeated analysis of variance. The BIC for the early loaded group was 46.17% ± 12.89%, and for the unloaded group was 44.4% ± 10.45%. This difference was not statistically significant (P = .811). The ISQ for the implants in the early loaded group (before they were removed) was 71 ± 7.35 and that of the unloaded group was 66.75 ± 11.86 .These differences were statistically insignificant. With regard to the result of this study, and the fact that the 2 groups showed no statistically significant differences in a number of major aspects, such as BIC and ISQ, it seems possible to load implants with an earlier than usual protocol with no adverse effects on implant success. It is necessary, however, to follow certain protocols for this type of loading.</description><subject>Animals</subject><subject>Connective Tissue - pathology</subject><subject>Crowns</subject><subject>Dental Implant-Abutment Design</subject><subject>Dental Implantation, Endosseous - methods</subject><subject>Dental Implants</subject><subject>Dental Materials - chemistry</subject><subject>Dental Prosthesis Retention</subject><subject>Dental Prosthesis, Implant-Supported</subject><subject>Dentistry</subject><subject>Dogs</subject><subject>Immediate Dental Implant Loading - methods</subject><subject>Mandible - pathology</subject><subject>Mandible - surgery</subject><subject>Models, Animal</subject><subject>Osseointegration - physiology</subject><subject>Periodontal Index</subject><subject>Periodontal Pocket - classification</subject><subject>Polycarboxylate Cement - chemistry</subject><subject>Prostheses</subject><subject>Studies</subject><subject>Success</subject><subject>Surface Properties</subject><subject>Surgery</subject><subject>Teeth</subject><subject>Time Factors</subject><subject>Tooth Extraction</subject><subject>Transplants &amp; implants</subject><issn>0160-6972</issn><issn>1548-1336</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>8G5</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><sourceid>GUQSH</sourceid><sourceid>M2O</sourceid><recordid>eNqNkb1OwzAURi0EouXnCZBQJJYyGO61YydhqxooRZW6wBw5tVOlSpNiJ6C-PQ4tDExM1rXO9-nah5ArhDsUkt-Px7OUvixmNKUIFIABOyJDFGFMkXN5TIaAEqhMIjYgZ86tPSKEwFMyYIxhKDAakmlq6lZVQbnZVqpu3UNglK12wYexrnOBa1WtldVB-9lQP6xMUDVKl_UqGKm63Pikazu9u70gJ4WqnLk8nOfk7enxdfJM54vpbDKe02WI2NIoESEYUDEWkIdMapkbHceAoWRcQRIzro3gUud5DCYXSVQUXPE8UTkypZCfk9G-d2ub9864NtuUbmkqv7xpOpehYEnCmWDyHygCJBCxyKM3f9B109naP6SnQukbZegpvqeWtnHOmiLbWv8FdpchZL2SrFeSeSVZ2l99K_Gp60N3l2-M_s38OOBfDTCFfQ</recordid><startdate>20140201</startdate><enddate>20140201</enddate><creator>Rismanchian, Mansour</creator><creator>Bajoghli, Farshad</creator><creator>Gholamreza, Tabakhian</creator><creator>Razavi, Mohamad</creator><general>Allen Press Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M1P</scope><scope>M2O</scope><scope>M7P</scope><scope>MBDVC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>7X8</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope></search><sort><creationdate>20140201</creationdate><title>Dental implants: early versus standard two-stage loading (animal study)</title><author>Rismanchian, Mansour ; Bajoghli, Farshad ; Gholamreza, Tabakhian ; Razavi, Mohamad</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c411t-79540e0a81f0b426d6bed88014623a09823de536dbb80eb597ff3a3b9ab12aa13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Animals</topic><topic>Connective Tissue - pathology</topic><topic>Crowns</topic><topic>Dental Implant-Abutment Design</topic><topic>Dental Implantation, Endosseous - methods</topic><topic>Dental Implants</topic><topic>Dental Materials - chemistry</topic><topic>Dental Prosthesis Retention</topic><topic>Dental Prosthesis, Implant-Supported</topic><topic>Dentistry</topic><topic>Dogs</topic><topic>Immediate Dental Implant Loading - methods</topic><topic>Mandible - pathology</topic><topic>Mandible - surgery</topic><topic>Models, Animal</topic><topic>Osseointegration - physiology</topic><topic>Periodontal Index</topic><topic>Periodontal Pocket - classification</topic><topic>Polycarboxylate Cement - chemistry</topic><topic>Prostheses</topic><topic>Studies</topic><topic>Success</topic><topic>Surface Properties</topic><topic>Surgery</topic><topic>Teeth</topic><topic>Time Factors</topic><topic>Tooth Extraction</topic><topic>Transplants &amp; implants</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rismanchian, Mansour</creatorcontrib><creatorcontrib>Bajoghli, Farshad</creatorcontrib><creatorcontrib>Gholamreza, Tabakhian</creatorcontrib><creatorcontrib>Razavi, Mohamad</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Research Library</collection><collection>Biological Science Database</collection><collection>Research Library (Corporate)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>The Journal of oral implantology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rismanchian, Mansour</au><au>Bajoghli, Farshad</au><au>Gholamreza, Tabakhian</au><au>Razavi, Mohamad</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dental implants: early versus standard two-stage loading (animal study)</atitle><jtitle>The Journal of oral implantology</jtitle><addtitle>J Oral Implantol</addtitle><date>2014-02-01</date><risdate>2014</risdate><volume>40</volume><issue>1</issue><spage>84</spage><epage>92</epage><pages>84-92</pages><issn>0160-6972</issn><eissn>1548-1336</eissn><abstract>Direct bone formation on the implant surface is a treatment goal in implant dentistry. It was always thought that a healing period of 3 months for the lower jaw and 5-6 months for the upper jaw was required for osseointegration to occur. Recent studies, however, show that with the early loading protocol, osseointegration is possible as well. The goal of this study was to evaluate clinical, histologic, and histomorphometric parameters of implants with early loading protocols and implants that did not undergo the early loading protocol. In this experimental study, the first to the fourth premolar teeth were extracted from the lower jaws of 3 dogs. After a healing period of 3 months, 12 BioHorizons internal implants 4.5 × 10.5 mm were placed in the mandible of the dogs. The implant stability quotient (ISQ) was recorded. After 3 weeks, half of the implants were exposed, and after recording ISQ, polycarbonate crowns were placed on them and occlusion was adjusted so that there was no contact in centric occlusion and no lateral movement with the opposing teeth. After 3 months, the ISQs were recorded for all the implants. Bleeding upon probing and pocket depths were measured for the early loading implants. All the implants were removed using a trephine bur, and cross-sections of 150 μm were prepared, from which the bone implant contact (BIC) and the type of bone around them were obtained. Statistical analysis was conducted with independent t test, paired t test, and repeated analysis of variance. The BIC for the early loaded group was 46.17% ± 12.89%, and for the unloaded group was 44.4% ± 10.45%. This difference was not statistically significant (P = .811). The ISQ for the implants in the early loaded group (before they were removed) was 71 ± 7.35 and that of the unloaded group was 66.75 ± 11.86 .These differences were statistically insignificant. With regard to the result of this study, and the fact that the 2 groups showed no statistically significant differences in a number of major aspects, such as BIC and ISQ, it seems possible to load implants with an earlier than usual protocol with no adverse effects on implant success. It is necessary, however, to follow certain protocols for this type of loading.</abstract><cop>United States</cop><pub>Allen Press Inc</pub><pmid>22214517</pmid><doi>10.1563/AAID-JOI-D-10-00202</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0160-6972
ispartof The Journal of oral implantology, 2014-02, Vol.40 (1), p.84-92
issn 0160-6972
1548-1336
language eng
recordid cdi_proquest_miscellaneous_1529932526
source MEDLINE; Allen Press Journals; EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection
subjects Animals
Connective Tissue - pathology
Crowns
Dental Implant-Abutment Design
Dental Implantation, Endosseous - methods
Dental Implants
Dental Materials - chemistry
Dental Prosthesis Retention
Dental Prosthesis, Implant-Supported
Dentistry
Dogs
Immediate Dental Implant Loading - methods
Mandible - pathology
Mandible - surgery
Models, Animal
Osseointegration - physiology
Periodontal Index
Periodontal Pocket - classification
Polycarboxylate Cement - chemistry
Prostheses
Studies
Success
Surface Properties
Surgery
Teeth
Time Factors
Tooth Extraction
Transplants & implants
title Dental implants: early versus standard two-stage loading (animal study)
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T00%3A56%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dental%20implants:%20early%20versus%20standard%20two-stage%20loading%20(animal%20study)&rft.jtitle=The%20Journal%20of%20oral%20implantology&rft.au=Rismanchian,%20Mansour&rft.date=2014-02-01&rft.volume=40&rft.issue=1&rft.spage=84&rft.epage=92&rft.pages=84-92&rft.issn=0160-6972&rft.eissn=1548-1336&rft_id=info:doi/10.1563/AAID-JOI-D-10-00202&rft_dat=%3Cproquest_cross%3E1510090727%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1514693264&rft_id=info:pmid/22214517&rfr_iscdi=true