Mechanical ventilators availability survey in Thai ICUs (ICU-RESOURCE I Study)
Mechanical ventilators (MV) have been progressing rapidly. New ventilator modes and supportive equipments have been developed. However; the MV status in Thai ICUs was not available. The objective of this report was to describe the MV supply and availability in Thai ICUs and review some important cha...
Gespeichert in:
Veröffentlicht in: | Journal of the Medical Association of Thailand 2014-01, Vol.97 Suppl 1, p.S1-S7 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | S7 |
---|---|
container_issue | |
container_start_page | S1 |
container_title | Journal of the Medical Association of Thailand |
container_volume | 97 Suppl 1 |
creator | Chittawatanarat, Kaweesak Bunburaphong, Thananchai Champunot, Ratapum |
description | Mechanical ventilators (MV) have been progressing rapidly. New ventilator modes and supportive equipments have been developed. However; the MV status in Thai ICUs was not available. The objective of this report was to describe the MV supply and availability in Thai ICUs and review some important characteristics regarding of the availability of MV MATERIAL AND METHOD: The ICU RESOURCE I study (Mechanical ventilator part) database was used in the present study. Hospital types, MV brands and models were recorded. Statistically significant differences between and among groups were defined as p-value < 0.05.
A total of 2,098 MVs were included in the present study. Of these, 448 electrically independent MVs (Bird's Mark) were noted (21.35%). The remainder of 1,650 (78.65%) MVs were electrically dependent MVs (eMV). About 90 percent of eMVs were from the following seven eMV brands including Benette, Hamilton, Event, Newport, CareFusion or Bird (volume type), Drager and Servo respectively. About half of them were from the two brands of Bennette and Hamilton. Recent advanced MVs including EvitaXL, Hamilton G5, Servo-I and Epi (NAVA) were more available in academic ICUs than in non-academic ICUs. The adult HFOV could be found only in academic ICUs in this survey
Bird Mark ventilators were also a high proportion of the MVs in Thai ICUs. Bennette and Hamilton were the most highly available MVin this survey. Advanced MV models were more available in academic ICUs (Thai Clinical Trial Registry: TCTR-201200005). |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_1528875369</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1528875369</sourcerecordid><originalsourceid>FETCH-LOGICAL-p126t-ac8530bf3f2ee9d28d90872de818bd08f6b90ebaacc16124efcafec5d7f336bf3</originalsourceid><addsrcrecordid>eNo1kDFPwzAUhD2AaCn8BeSxDJEcO3adEUUBIhUqtc0cvdjPqlGaljiplH9PpJbl7obvbrg7MmcxlxHnTM_IYwg_jCUyVeKBzHiipdRCzcn3F5oDtN5AQy_Y9r6B_tQFCheYYu0b3480DN0FR-pbuj-Ap0VWBrqcNNrmu025zXJa0F0_2PH1idw7aAI-33xByvd8n31G681Hkb2to3PMVR-B0VKw2gnHEVPLtU2ZXnGLOta1ZdqpOmVYAxgTq5gn6Aw4NNKunBBq6i3I8rp77k6_A4a-OvpgsGmgxdMQqlhyrVdSqHRCX27oUB_RVufOH6Ebq_8PxB_n5lbP</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1528875369</pqid></control><display><type>article</type><title>Mechanical ventilators availability survey in Thai ICUs (ICU-RESOURCE I Study)</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Chittawatanarat, Kaweesak ; Bunburaphong, Thananchai ; Champunot, Ratapum</creator><creatorcontrib>Chittawatanarat, Kaweesak ; Bunburaphong, Thananchai ; Champunot, Ratapum ; Thai Society of Critical Care Medicine Study Group</creatorcontrib><description>Mechanical ventilators (MV) have been progressing rapidly. New ventilator modes and supportive equipments have been developed. However; the MV status in Thai ICUs was not available. The objective of this report was to describe the MV supply and availability in Thai ICUs and review some important characteristics regarding of the availability of MV MATERIAL AND METHOD: The ICU RESOURCE I study (Mechanical ventilator part) database was used in the present study. Hospital types, MV brands and models were recorded. Statistically significant differences between and among groups were defined as p-value < 0.05.
A total of 2,098 MVs were included in the present study. Of these, 448 electrically independent MVs (Bird's Mark) were noted (21.35%). The remainder of 1,650 (78.65%) MVs were electrically dependent MVs (eMV). About 90 percent of eMVs were from the following seven eMV brands including Benette, Hamilton, Event, Newport, CareFusion or Bird (volume type), Drager and Servo respectively. About half of them were from the two brands of Bennette and Hamilton. Recent advanced MVs including EvitaXL, Hamilton G5, Servo-I and Epi (NAVA) were more available in academic ICUs than in non-academic ICUs. The adult HFOV could be found only in academic ICUs in this survey
Bird Mark ventilators were also a high proportion of the MVs in Thai ICUs. Bennette and Hamilton were the most highly available MVin this survey. Advanced MV models were more available in academic ICUs (Thai Clinical Trial Registry: TCTR-201200005).</description><identifier>ISSN: 0125-2208</identifier><identifier>PMID: 24855836</identifier><language>eng</language><publisher>Thailand</publisher><subject>Health Services Accessibility - statistics & numerical data ; Humans ; Intensive Care Units - supply & distribution ; Thailand ; Ventilators, Mechanical - supply & distribution</subject><ispartof>Journal of the Medical Association of Thailand, 2014-01, Vol.97 Suppl 1, p.S1-S7</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24855836$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Chittawatanarat, Kaweesak</creatorcontrib><creatorcontrib>Bunburaphong, Thananchai</creatorcontrib><creatorcontrib>Champunot, Ratapum</creatorcontrib><creatorcontrib>Thai Society of Critical Care Medicine Study Group</creatorcontrib><title>Mechanical ventilators availability survey in Thai ICUs (ICU-RESOURCE I Study)</title><title>Journal of the Medical Association of Thailand</title><addtitle>J Med Assoc Thai</addtitle><description>Mechanical ventilators (MV) have been progressing rapidly. New ventilator modes and supportive equipments have been developed. However; the MV status in Thai ICUs was not available. The objective of this report was to describe the MV supply and availability in Thai ICUs and review some important characteristics regarding of the availability of MV MATERIAL AND METHOD: The ICU RESOURCE I study (Mechanical ventilator part) database was used in the present study. Hospital types, MV brands and models were recorded. Statistically significant differences between and among groups were defined as p-value < 0.05.
A total of 2,098 MVs were included in the present study. Of these, 448 electrically independent MVs (Bird's Mark) were noted (21.35%). The remainder of 1,650 (78.65%) MVs were electrically dependent MVs (eMV). About 90 percent of eMVs were from the following seven eMV brands including Benette, Hamilton, Event, Newport, CareFusion or Bird (volume type), Drager and Servo respectively. About half of them were from the two brands of Bennette and Hamilton. Recent advanced MVs including EvitaXL, Hamilton G5, Servo-I and Epi (NAVA) were more available in academic ICUs than in non-academic ICUs. The adult HFOV could be found only in academic ICUs in this survey
Bird Mark ventilators were also a high proportion of the MVs in Thai ICUs. Bennette and Hamilton were the most highly available MVin this survey. Advanced MV models were more available in academic ICUs (Thai Clinical Trial Registry: TCTR-201200005).</description><subject>Health Services Accessibility - statistics & numerical data</subject><subject>Humans</subject><subject>Intensive Care Units - supply & distribution</subject><subject>Thailand</subject><subject>Ventilators, Mechanical - supply & distribution</subject><issn>0125-2208</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo1kDFPwzAUhD2AaCn8BeSxDJEcO3adEUUBIhUqtc0cvdjPqlGaljiplH9PpJbl7obvbrg7MmcxlxHnTM_IYwg_jCUyVeKBzHiipdRCzcn3F5oDtN5AQy_Y9r6B_tQFCheYYu0b3480DN0FR-pbuj-Ap0VWBrqcNNrmu025zXJa0F0_2PH1idw7aAI-33xByvd8n31G681Hkb2to3PMVR-B0VKw2gnHEVPLtU2ZXnGLOta1ZdqpOmVYAxgTq5gn6Aw4NNKunBBq6i3I8rp77k6_A4a-OvpgsGmgxdMQqlhyrVdSqHRCX27oUB_RVufOH6Ebq_8PxB_n5lbP</recordid><startdate>201401</startdate><enddate>201401</enddate><creator>Chittawatanarat, Kaweesak</creator><creator>Bunburaphong, Thananchai</creator><creator>Champunot, Ratapum</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>201401</creationdate><title>Mechanical ventilators availability survey in Thai ICUs (ICU-RESOURCE I Study)</title><author>Chittawatanarat, Kaweesak ; Bunburaphong, Thananchai ; Champunot, Ratapum</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p126t-ac8530bf3f2ee9d28d90872de818bd08f6b90ebaacc16124efcafec5d7f336bf3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Health Services Accessibility - statistics & numerical data</topic><topic>Humans</topic><topic>Intensive Care Units - supply & distribution</topic><topic>Thailand</topic><topic>Ventilators, Mechanical - supply & distribution</topic><toplevel>online_resources</toplevel><creatorcontrib>Chittawatanarat, Kaweesak</creatorcontrib><creatorcontrib>Bunburaphong, Thananchai</creatorcontrib><creatorcontrib>Champunot, Ratapum</creatorcontrib><creatorcontrib>Thai Society of Critical Care Medicine Study Group</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the Medical Association of Thailand</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chittawatanarat, Kaweesak</au><au>Bunburaphong, Thananchai</au><au>Champunot, Ratapum</au><aucorp>Thai Society of Critical Care Medicine Study Group</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Mechanical ventilators availability survey in Thai ICUs (ICU-RESOURCE I Study)</atitle><jtitle>Journal of the Medical Association of Thailand</jtitle><addtitle>J Med Assoc Thai</addtitle><date>2014-01</date><risdate>2014</risdate><volume>97 Suppl 1</volume><spage>S1</spage><epage>S7</epage><pages>S1-S7</pages><issn>0125-2208</issn><abstract>Mechanical ventilators (MV) have been progressing rapidly. New ventilator modes and supportive equipments have been developed. However; the MV status in Thai ICUs was not available. The objective of this report was to describe the MV supply and availability in Thai ICUs and review some important characteristics regarding of the availability of MV MATERIAL AND METHOD: The ICU RESOURCE I study (Mechanical ventilator part) database was used in the present study. Hospital types, MV brands and models were recorded. Statistically significant differences between and among groups were defined as p-value < 0.05.
A total of 2,098 MVs were included in the present study. Of these, 448 electrically independent MVs (Bird's Mark) were noted (21.35%). The remainder of 1,650 (78.65%) MVs were electrically dependent MVs (eMV). About 90 percent of eMVs were from the following seven eMV brands including Benette, Hamilton, Event, Newport, CareFusion or Bird (volume type), Drager and Servo respectively. About half of them were from the two brands of Bennette and Hamilton. Recent advanced MVs including EvitaXL, Hamilton G5, Servo-I and Epi (NAVA) were more available in academic ICUs than in non-academic ICUs. The adult HFOV could be found only in academic ICUs in this survey
Bird Mark ventilators were also a high proportion of the MVs in Thai ICUs. Bennette and Hamilton were the most highly available MVin this survey. Advanced MV models were more available in academic ICUs (Thai Clinical Trial Registry: TCTR-201200005).</abstract><cop>Thailand</cop><pmid>24855836</pmid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0125-2208 |
ispartof | Journal of the Medical Association of Thailand, 2014-01, Vol.97 Suppl 1, p.S1-S7 |
issn | 0125-2208 |
language | eng |
recordid | cdi_proquest_miscellaneous_1528875369 |
source | MEDLINE; Alma/SFX Local Collection |
subjects | Health Services Accessibility - statistics & numerical data Humans Intensive Care Units - supply & distribution Thailand Ventilators, Mechanical - supply & distribution |
title | Mechanical ventilators availability survey in Thai ICUs (ICU-RESOURCE I Study) |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T17%3A57%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Mechanical%20ventilators%20availability%20survey%20in%20Thai%20ICUs%20(ICU-RESOURCE%20I%20Study)&rft.jtitle=Journal%20of%20the%20Medical%20Association%20of%20Thailand&rft.au=Chittawatanarat,%20Kaweesak&rft.aucorp=Thai%20Society%20of%20Critical%20Care%20Medicine%20Study%20Group&rft.date=2014-01&rft.volume=97%20Suppl%201&rft.spage=S1&rft.epage=S7&rft.pages=S1-S7&rft.issn=0125-2208&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E1528875369%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1528875369&rft_id=info:pmid/24855836&rfr_iscdi=true |