A Comparison of Nonlocking Semitubular Plates and Precontoured Locking Plates for First Metatarsophalangeal Joint Arthrodesis
Background: First metatarsophalangeal (MTP) joint arthrodesis is a successful, commonly performed procedure for many conditions affecting this joint. The purpose of this retrospective study was to compare the clinical and radiographic outcomes between patients who had primary first MTP joint fusions...
Gespeichert in:
Veröffentlicht in: | Foot & ankle international 2014-05, Vol.35 (5), p.438-444 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 444 |
---|---|
container_issue | 5 |
container_start_page | 438 |
container_title | Foot & ankle international |
container_volume | 35 |
creator | Mayer, Stephanie A. Zelenski, Nicole A. DeOrio, James K. Easley, Mark E. Nunley, James A. |
description | Background:
First metatarsophalangeal (MTP) joint arthrodesis is a successful, commonly performed procedure for many conditions affecting this joint. The purpose of this retrospective study was to compare the clinical and radiographic outcomes between patients who had primary first MTP joint fusions with either noncontoured stainless steel semitubular plates or precontoured plates. Our hypothesis was that there would be no difference in clinical or radiographic outcomes between these groups.
Methods:
A search based on operative report coding was performed to detect all patients who had undergone primary first MTP joint arthrodesis with a dorsal plating construct at our institution from 2005 to 2010. A retrospective review of electronic medical records and postoperative radiographs was performed to determine time to clinical and radiographic union, pain scores, complications, MTP angle, and proximal phalanx to floor angle. A Kruskal-Wallis test was used for continuous variables, and a chi-square or Fisher exact test was used for categorical variables to determine statistical significance between the 2 groups.
Results:
We identified 128 patients who met our inclusion criteria. One hundred and two feet in 97 patients underwent arthrodesis with a noncontoured, stainless steel 1/3 tubular plate (group 1) and 26 feet in 21 patients with a precontoured, locking plate (group 2). The patients presented with a variety of inflammatory and noninflammatory preoperative diagnoses. The overall union rate, complication rate, time to radiographic healing, MTP angle, and patient-reported visual analog scale (VAS) score were similar between the 2 groups. Clinical time to healing was more rapid in the noncontoured group (3.7 months vs 4.8 degrees in precontoured) (P = .02). The radiographically measured proximal phalanx to floor angle was significantly decreased in noncontoured patients (2.6 degrees vs 4.6 degrees in precontoured, P = .04).
In patients who had a diagnosis of an inflammatory arthropathy, the union rate fell to 84.3% (27/32) in the noncontoured group and 87.5% (7/8) in the precontoured group, and time to radiographic as well as clinical union increased in both groups. When patients with inflammatory arthropathies were compared with noninflammatory patients within groups, it was found that the time to both clinical and radiographic union was significantly longer in the noncontoured group for those with an inflammatory arthropathy (P = .0052, P = .022). For the p |
doi_str_mv | 10.1177/1071100714520695 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1521336467</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1071100714520695</sage_id><sourcerecordid>1521336467</sourcerecordid><originalsourceid>FETCH-LOGICAL-c403t-969de9580a5a07610dbeec7c59b5aab128ee66a82bf8ba0f87b9a207beacdf053</originalsourceid><addsrcrecordid>eNp1kLtPxDAMxiME4r0zoYwsBadtmnY8nXjqeEjAXDmte1domyNJBwb-d3K6gwGJxbb0_fzJ_hg7EXAuhFIXApQQEEoqY8gKucX2RZGmkcpVth3moEQrfY8dOPcGIFQiil22F6cSBIhkn31N-NT0S7StMwM3DX8wQ2eq93aY82fqWz_qsUPLnzr05DgONX-yVJnBm9FSzWcbdqM3xvKr1jrP78mjR-vMcoEdDnPCjt-ZdvB8Yv3Cmppc647YToOdo-NNP2SvV5cv05to9nh9O53MoiqFxEdFVtRUyBxQIqhMQK2JKlXJQktELeKcKMswj3WTa4QmV7rAGJQmrOoGZHLIzta-S2s-RnK-7FtXURcOIzO6UshYJEmWZiqgsEYra5yz1JRL2_ZoP0sB5Sr08m_oYeV04z7qnurfhZ-UAxCtAYdzKt9CckP49n_Db1Rci-Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1521336467</pqid></control><display><type>article</type><title>A Comparison of Nonlocking Semitubular Plates and Precontoured Locking Plates for First Metatarsophalangeal Joint Arthrodesis</title><source>Access via SAGE</source><source>MEDLINE</source><creator>Mayer, Stephanie A. ; Zelenski, Nicole A. ; DeOrio, James K. ; Easley, Mark E. ; Nunley, James A.</creator><creatorcontrib>Mayer, Stephanie A. ; Zelenski, Nicole A. ; DeOrio, James K. ; Easley, Mark E. ; Nunley, James A.</creatorcontrib><description>Background:
First metatarsophalangeal (MTP) joint arthrodesis is a successful, commonly performed procedure for many conditions affecting this joint. The purpose of this retrospective study was to compare the clinical and radiographic outcomes between patients who had primary first MTP joint fusions with either noncontoured stainless steel semitubular plates or precontoured plates. Our hypothesis was that there would be no difference in clinical or radiographic outcomes between these groups.
Methods:
A search based on operative report coding was performed to detect all patients who had undergone primary first MTP joint arthrodesis with a dorsal plating construct at our institution from 2005 to 2010. A retrospective review of electronic medical records and postoperative radiographs was performed to determine time to clinical and radiographic union, pain scores, complications, MTP angle, and proximal phalanx to floor angle. A Kruskal-Wallis test was used for continuous variables, and a chi-square or Fisher exact test was used for categorical variables to determine statistical significance between the 2 groups.
Results:
We identified 128 patients who met our inclusion criteria. One hundred and two feet in 97 patients underwent arthrodesis with a noncontoured, stainless steel 1/3 tubular plate (group 1) and 26 feet in 21 patients with a precontoured, locking plate (group 2). The patients presented with a variety of inflammatory and noninflammatory preoperative diagnoses. The overall union rate, complication rate, time to radiographic healing, MTP angle, and patient-reported visual analog scale (VAS) score were similar between the 2 groups. Clinical time to healing was more rapid in the noncontoured group (3.7 months vs 4.8 degrees in precontoured) (P = .02). The radiographically measured proximal phalanx to floor angle was significantly decreased in noncontoured patients (2.6 degrees vs 4.6 degrees in precontoured, P = .04).
In patients who had a diagnosis of an inflammatory arthropathy, the union rate fell to 84.3% (27/32) in the noncontoured group and 87.5% (7/8) in the precontoured group, and time to radiographic as well as clinical union increased in both groups. When patients with inflammatory arthropathies were compared with noninflammatory patients within groups, it was found that the time to both clinical and radiographic union was significantly longer in the noncontoured group for those with an inflammatory arthropathy (P = .0052, P = .022). For the precontoured group, these values were not statistically significant (P = .089, P = .43). Additionally, the cost of the noncontoured implants was significantly less than that of the precontoured implants.
Conclusion:
In this study, clinical time to healing of primary first MTP fusion with dorsal plate and screw constructs was improved with the use of noncontoured plates. However, other clinical indicators such as pain, complication rate, MTP angle, and VAS score did not differ between groups. Noncontoured plates are less expensive, and thus the decision to use precontoured plates routinely should be made cautiously. However, in the presence of inflammatory arthropathy, the use of precontoured plates may be justified given that the use of these plates in the inflammatory group resulted in improved radiographic and clinical union.
Level of Evidence:
Level III, comparative series.</description><identifier>ISSN: 1071-1007</identifier><identifier>EISSN: 1944-7876</identifier><identifier>DOI: 10.1177/1071100714520695</identifier><identifier>PMID: 24501013</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><subject>Adult ; Arthrodesis - methods ; Bone Plates ; Female ; Fracture Fixation, Internal - methods ; Hallux - surgery ; Humans ; Male ; Metatarsophalangeal Joint - surgery ; Middle Aged ; Retrospective Studies ; Treatment Outcome</subject><ispartof>Foot & ankle international, 2014-05, Vol.35 (5), p.438-444</ispartof><rights>The Author(s) 2014</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c403t-969de9580a5a07610dbeec7c59b5aab128ee66a82bf8ba0f87b9a207beacdf053</citedby><cites>FETCH-LOGICAL-c403t-969de9580a5a07610dbeec7c59b5aab128ee66a82bf8ba0f87b9a207beacdf053</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/1071100714520695$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/1071100714520695$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24501013$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mayer, Stephanie A.</creatorcontrib><creatorcontrib>Zelenski, Nicole A.</creatorcontrib><creatorcontrib>DeOrio, James K.</creatorcontrib><creatorcontrib>Easley, Mark E.</creatorcontrib><creatorcontrib>Nunley, James A.</creatorcontrib><title>A Comparison of Nonlocking Semitubular Plates and Precontoured Locking Plates for First Metatarsophalangeal Joint Arthrodesis</title><title>Foot & ankle international</title><addtitle>Foot Ankle Int</addtitle><description>Background:
First metatarsophalangeal (MTP) joint arthrodesis is a successful, commonly performed procedure for many conditions affecting this joint. The purpose of this retrospective study was to compare the clinical and radiographic outcomes between patients who had primary first MTP joint fusions with either noncontoured stainless steel semitubular plates or precontoured plates. Our hypothesis was that there would be no difference in clinical or radiographic outcomes between these groups.
Methods:
A search based on operative report coding was performed to detect all patients who had undergone primary first MTP joint arthrodesis with a dorsal plating construct at our institution from 2005 to 2010. A retrospective review of electronic medical records and postoperative radiographs was performed to determine time to clinical and radiographic union, pain scores, complications, MTP angle, and proximal phalanx to floor angle. A Kruskal-Wallis test was used for continuous variables, and a chi-square or Fisher exact test was used for categorical variables to determine statistical significance between the 2 groups.
Results:
We identified 128 patients who met our inclusion criteria. One hundred and two feet in 97 patients underwent arthrodesis with a noncontoured, stainless steel 1/3 tubular plate (group 1) and 26 feet in 21 patients with a precontoured, locking plate (group 2). The patients presented with a variety of inflammatory and noninflammatory preoperative diagnoses. The overall union rate, complication rate, time to radiographic healing, MTP angle, and patient-reported visual analog scale (VAS) score were similar between the 2 groups. Clinical time to healing was more rapid in the noncontoured group (3.7 months vs 4.8 degrees in precontoured) (P = .02). The radiographically measured proximal phalanx to floor angle was significantly decreased in noncontoured patients (2.6 degrees vs 4.6 degrees in precontoured, P = .04).
In patients who had a diagnosis of an inflammatory arthropathy, the union rate fell to 84.3% (27/32) in the noncontoured group and 87.5% (7/8) in the precontoured group, and time to radiographic as well as clinical union increased in both groups. When patients with inflammatory arthropathies were compared with noninflammatory patients within groups, it was found that the time to both clinical and radiographic union was significantly longer in the noncontoured group for those with an inflammatory arthropathy (P = .0052, P = .022). For the precontoured group, these values were not statistically significant (P = .089, P = .43). Additionally, the cost of the noncontoured implants was significantly less than that of the precontoured implants.
Conclusion:
In this study, clinical time to healing of primary first MTP fusion with dorsal plate and screw constructs was improved with the use of noncontoured plates. However, other clinical indicators such as pain, complication rate, MTP angle, and VAS score did not differ between groups. Noncontoured plates are less expensive, and thus the decision to use precontoured plates routinely should be made cautiously. However, in the presence of inflammatory arthropathy, the use of precontoured plates may be justified given that the use of these plates in the inflammatory group resulted in improved radiographic and clinical union.
Level of Evidence:
Level III, comparative series.</description><subject>Adult</subject><subject>Arthrodesis - methods</subject><subject>Bone Plates</subject><subject>Female</subject><subject>Fracture Fixation, Internal - methods</subject><subject>Hallux - surgery</subject><subject>Humans</subject><subject>Male</subject><subject>Metatarsophalangeal Joint - surgery</subject><subject>Middle Aged</subject><subject>Retrospective Studies</subject><subject>Treatment Outcome</subject><issn>1071-1007</issn><issn>1944-7876</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kLtPxDAMxiME4r0zoYwsBadtmnY8nXjqeEjAXDmte1domyNJBwb-d3K6gwGJxbb0_fzJ_hg7EXAuhFIXApQQEEoqY8gKucX2RZGmkcpVth3moEQrfY8dOPcGIFQiil22F6cSBIhkn31N-NT0S7StMwM3DX8wQ2eq93aY82fqWz_qsUPLnzr05DgONX-yVJnBm9FSzWcbdqM3xvKr1jrP78mjR-vMcoEdDnPCjt-ZdvB8Yv3Cmppc647YToOdo-NNP2SvV5cv05to9nh9O53MoiqFxEdFVtRUyBxQIqhMQK2JKlXJQktELeKcKMswj3WTa4QmV7rAGJQmrOoGZHLIzta-S2s-RnK-7FtXURcOIzO6UshYJEmWZiqgsEYra5yz1JRL2_ZoP0sB5Sr08m_oYeV04z7qnurfhZ-UAxCtAYdzKt9CckP49n_Db1Rci-Q</recordid><startdate>20140501</startdate><enddate>20140501</enddate><creator>Mayer, Stephanie A.</creator><creator>Zelenski, Nicole A.</creator><creator>DeOrio, James K.</creator><creator>Easley, Mark E.</creator><creator>Nunley, James A.</creator><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20140501</creationdate><title>A Comparison of Nonlocking Semitubular Plates and Precontoured Locking Plates for First Metatarsophalangeal Joint Arthrodesis</title><author>Mayer, Stephanie A. ; Zelenski, Nicole A. ; DeOrio, James K. ; Easley, Mark E. ; Nunley, James A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c403t-969de9580a5a07610dbeec7c59b5aab128ee66a82bf8ba0f87b9a207beacdf053</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Adult</topic><topic>Arthrodesis - methods</topic><topic>Bone Plates</topic><topic>Female</topic><topic>Fracture Fixation, Internal - methods</topic><topic>Hallux - surgery</topic><topic>Humans</topic><topic>Male</topic><topic>Metatarsophalangeal Joint - surgery</topic><topic>Middle Aged</topic><topic>Retrospective Studies</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mayer, Stephanie A.</creatorcontrib><creatorcontrib>Zelenski, Nicole A.</creatorcontrib><creatorcontrib>DeOrio, James K.</creatorcontrib><creatorcontrib>Easley, Mark E.</creatorcontrib><creatorcontrib>Nunley, James A.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Foot & ankle international</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mayer, Stephanie A.</au><au>Zelenski, Nicole A.</au><au>DeOrio, James K.</au><au>Easley, Mark E.</au><au>Nunley, James A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Comparison of Nonlocking Semitubular Plates and Precontoured Locking Plates for First Metatarsophalangeal Joint Arthrodesis</atitle><jtitle>Foot & ankle international</jtitle><addtitle>Foot Ankle Int</addtitle><date>2014-05-01</date><risdate>2014</risdate><volume>35</volume><issue>5</issue><spage>438</spage><epage>444</epage><pages>438-444</pages><issn>1071-1007</issn><eissn>1944-7876</eissn><abstract>Background:
First metatarsophalangeal (MTP) joint arthrodesis is a successful, commonly performed procedure for many conditions affecting this joint. The purpose of this retrospective study was to compare the clinical and radiographic outcomes between patients who had primary first MTP joint fusions with either noncontoured stainless steel semitubular plates or precontoured plates. Our hypothesis was that there would be no difference in clinical or radiographic outcomes between these groups.
Methods:
A search based on operative report coding was performed to detect all patients who had undergone primary first MTP joint arthrodesis with a dorsal plating construct at our institution from 2005 to 2010. A retrospective review of electronic medical records and postoperative radiographs was performed to determine time to clinical and radiographic union, pain scores, complications, MTP angle, and proximal phalanx to floor angle. A Kruskal-Wallis test was used for continuous variables, and a chi-square or Fisher exact test was used for categorical variables to determine statistical significance between the 2 groups.
Results:
We identified 128 patients who met our inclusion criteria. One hundred and two feet in 97 patients underwent arthrodesis with a noncontoured, stainless steel 1/3 tubular plate (group 1) and 26 feet in 21 patients with a precontoured, locking plate (group 2). The patients presented with a variety of inflammatory and noninflammatory preoperative diagnoses. The overall union rate, complication rate, time to radiographic healing, MTP angle, and patient-reported visual analog scale (VAS) score were similar between the 2 groups. Clinical time to healing was more rapid in the noncontoured group (3.7 months vs 4.8 degrees in precontoured) (P = .02). The radiographically measured proximal phalanx to floor angle was significantly decreased in noncontoured patients (2.6 degrees vs 4.6 degrees in precontoured, P = .04).
In patients who had a diagnosis of an inflammatory arthropathy, the union rate fell to 84.3% (27/32) in the noncontoured group and 87.5% (7/8) in the precontoured group, and time to radiographic as well as clinical union increased in both groups. When patients with inflammatory arthropathies were compared with noninflammatory patients within groups, it was found that the time to both clinical and radiographic union was significantly longer in the noncontoured group for those with an inflammatory arthropathy (P = .0052, P = .022). For the precontoured group, these values were not statistically significant (P = .089, P = .43). Additionally, the cost of the noncontoured implants was significantly less than that of the precontoured implants.
Conclusion:
In this study, clinical time to healing of primary first MTP fusion with dorsal plate and screw constructs was improved with the use of noncontoured plates. However, other clinical indicators such as pain, complication rate, MTP angle, and VAS score did not differ between groups. Noncontoured plates are less expensive, and thus the decision to use precontoured plates routinely should be made cautiously. However, in the presence of inflammatory arthropathy, the use of precontoured plates may be justified given that the use of these plates in the inflammatory group resulted in improved radiographic and clinical union.
Level of Evidence:
Level III, comparative series.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>24501013</pmid><doi>10.1177/1071100714520695</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1071-1007 |
ispartof | Foot & ankle international, 2014-05, Vol.35 (5), p.438-444 |
issn | 1071-1007 1944-7876 |
language | eng |
recordid | cdi_proquest_miscellaneous_1521336467 |
source | Access via SAGE; MEDLINE |
subjects | Adult Arthrodesis - methods Bone Plates Female Fracture Fixation, Internal - methods Hallux - surgery Humans Male Metatarsophalangeal Joint - surgery Middle Aged Retrospective Studies Treatment Outcome |
title | A Comparison of Nonlocking Semitubular Plates and Precontoured Locking Plates for First Metatarsophalangeal Joint Arthrodesis |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-19T05%3A01%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Comparison%20of%20Nonlocking%20Semitubular%20Plates%20and%20Precontoured%20Locking%20Plates%20for%20First%20Metatarsophalangeal%20Joint%20Arthrodesis&rft.jtitle=Foot%20&%20ankle%20international&rft.au=Mayer,%20Stephanie%20A.&rft.date=2014-05-01&rft.volume=35&rft.issue=5&rft.spage=438&rft.epage=444&rft.pages=438-444&rft.issn=1071-1007&rft.eissn=1944-7876&rft_id=info:doi/10.1177/1071100714520695&rft_dat=%3Cproquest_cross%3E1521336467%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1521336467&rft_id=info:pmid/24501013&rft_sage_id=10.1177_1071100714520695&rfr_iscdi=true |