Pyrene based selective–ratiometric fluorescent sensing of zinc and pyrophosphate ions

A simple pyrene-based receptor has been synthesized. It shows a colorimetric and ratiometric fluorescent detection of zinc in aqueous solution. The ratiometric fluorescent change has been accounted to the conformational change of the probe. The ratiometric fluorescence change has been further suppor...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical methods 2014-01, Vol.6 (7), p.2343-2348
Hauptverfasser: Sivaraman, Gandhi, Anand, Thangaraj, Chellappa, Duraisamy
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2348
container_issue 7
container_start_page 2343
container_title Analytical methods
container_volume 6
creator Sivaraman, Gandhi
Anand, Thangaraj
Chellappa, Duraisamy
description A simple pyrene-based receptor has been synthesized. It shows a colorimetric and ratiometric fluorescent detection of zinc in aqueous solution. The ratiometric fluorescent change has been accounted to the conformational change of the probe. The ratiometric fluorescence change has been further supported by DFT/TDDFT calculations. The PDP-1 + Zn 2+ complex is also further successfully utilized for ratiometric fluorescence detection of pyrophosphate anions in buffered aqueous solution. The applicability of these probes for real sample analysis for the detection of Zn( ii ) and pyrophosphate ions has been also studied.
doi_str_mv 10.1039/C3AY42057D
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1520937634</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1520937634</sourcerecordid><originalsourceid>FETCH-LOGICAL-c367t-f9ed7cc4e86131e4c901dacd068f0991b75ef5718679c785bfd65872947865d03</originalsourceid><addsrcrecordid>eNpFkM1KAzEcxIMoWKsXnyBHEVaTZpNsjlI_oaAHRTwtafKPjWyTNUmFevIdfEOfxJWKnmYOP4aZQeiQkhNKmDqdsrOnekK4PN9CIyq5qpSQavvPC7KL9nJ-IUQoJugIPd6tEwTAc53B4gwdmOLf4OvjM-ni4xJK8ga7bhUTZAOhDEzIPjzj6PC7DwbrYHG_TrFfxNwvdAHsY8j7aMfpLsPBr47Rw-XF_fS6mt1e3UzPZpVhQpbKKbDSmBoaQRmF2ihCrTaWiMYRpehccnBc0mZYYWTD584K3siJqmUjuCVsjI42uX2KryvIpV36oWfX6QBxlVvKJ0QxKVg9oMcb1KSYcwLX9skvdVq3lLQ_77X_77FvDG9kBg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1520937634</pqid></control><display><type>article</type><title>Pyrene based selective–ratiometric fluorescent sensing of zinc and pyrophosphate ions</title><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Sivaraman, Gandhi ; Anand, Thangaraj ; Chellappa, Duraisamy</creator><creatorcontrib>Sivaraman, Gandhi ; Anand, Thangaraj ; Chellappa, Duraisamy</creatorcontrib><description>A simple pyrene-based receptor has been synthesized. It shows a colorimetric and ratiometric fluorescent detection of zinc in aqueous solution. The ratiometric fluorescent change has been accounted to the conformational change of the probe. The ratiometric fluorescence change has been further supported by DFT/TDDFT calculations. The PDP-1 + Zn 2+ complex is also further successfully utilized for ratiometric fluorescence detection of pyrophosphate anions in buffered aqueous solution. The applicability of these probes for real sample analysis for the detection of Zn( ii ) and pyrophosphate ions has been also studied.</description><identifier>ISSN: 1759-9660</identifier><identifier>EISSN: 1759-9679</identifier><identifier>DOI: 10.1039/C3AY42057D</identifier><language>eng</language><subject>Anions ; Aqueous solutions ; Buffers ; Colorimetry ; Fluorescence ; Mathematical analysis ; Receptors ; Zinc</subject><ispartof>Analytical methods, 2014-01, Vol.6 (7), p.2343-2348</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c367t-f9ed7cc4e86131e4c901dacd068f0991b75ef5718679c785bfd65872947865d03</citedby><cites>FETCH-LOGICAL-c367t-f9ed7cc4e86131e4c901dacd068f0991b75ef5718679c785bfd65872947865d03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,27929,27930</link.rule.ids></links><search><creatorcontrib>Sivaraman, Gandhi</creatorcontrib><creatorcontrib>Anand, Thangaraj</creatorcontrib><creatorcontrib>Chellappa, Duraisamy</creatorcontrib><title>Pyrene based selective–ratiometric fluorescent sensing of zinc and pyrophosphate ions</title><title>Analytical methods</title><description>A simple pyrene-based receptor has been synthesized. It shows a colorimetric and ratiometric fluorescent detection of zinc in aqueous solution. The ratiometric fluorescent change has been accounted to the conformational change of the probe. The ratiometric fluorescence change has been further supported by DFT/TDDFT calculations. The PDP-1 + Zn 2+ complex is also further successfully utilized for ratiometric fluorescence detection of pyrophosphate anions in buffered aqueous solution. The applicability of these probes for real sample analysis for the detection of Zn( ii ) and pyrophosphate ions has been also studied.</description><subject>Anions</subject><subject>Aqueous solutions</subject><subject>Buffers</subject><subject>Colorimetry</subject><subject>Fluorescence</subject><subject>Mathematical analysis</subject><subject>Receptors</subject><subject>Zinc</subject><issn>1759-9660</issn><issn>1759-9679</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNpFkM1KAzEcxIMoWKsXnyBHEVaTZpNsjlI_oaAHRTwtafKPjWyTNUmFevIdfEOfxJWKnmYOP4aZQeiQkhNKmDqdsrOnekK4PN9CIyq5qpSQavvPC7KL9nJ-IUQoJugIPd6tEwTAc53B4gwdmOLf4OvjM-ni4xJK8ga7bhUTZAOhDEzIPjzj6PC7DwbrYHG_TrFfxNwvdAHsY8j7aMfpLsPBr47Rw-XF_fS6mt1e3UzPZpVhQpbKKbDSmBoaQRmF2ihCrTaWiMYRpehccnBc0mZYYWTD584K3siJqmUjuCVsjI42uX2KryvIpV36oWfX6QBxlVvKJ0QxKVg9oMcb1KSYcwLX9skvdVq3lLQ_77X_77FvDG9kBg</recordid><startdate>20140101</startdate><enddate>20140101</enddate><creator>Sivaraman, Gandhi</creator><creator>Anand, Thangaraj</creator><creator>Chellappa, Duraisamy</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20140101</creationdate><title>Pyrene based selective–ratiometric fluorescent sensing of zinc and pyrophosphate ions</title><author>Sivaraman, Gandhi ; Anand, Thangaraj ; Chellappa, Duraisamy</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c367t-f9ed7cc4e86131e4c901dacd068f0991b75ef5718679c785bfd65872947865d03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Anions</topic><topic>Aqueous solutions</topic><topic>Buffers</topic><topic>Colorimetry</topic><topic>Fluorescence</topic><topic>Mathematical analysis</topic><topic>Receptors</topic><topic>Zinc</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sivaraman, Gandhi</creatorcontrib><creatorcontrib>Anand, Thangaraj</creatorcontrib><creatorcontrib>Chellappa, Duraisamy</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Analytical methods</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sivaraman, Gandhi</au><au>Anand, Thangaraj</au><au>Chellappa, Duraisamy</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Pyrene based selective–ratiometric fluorescent sensing of zinc and pyrophosphate ions</atitle><jtitle>Analytical methods</jtitle><date>2014-01-01</date><risdate>2014</risdate><volume>6</volume><issue>7</issue><spage>2343</spage><epage>2348</epage><pages>2343-2348</pages><issn>1759-9660</issn><eissn>1759-9679</eissn><abstract>A simple pyrene-based receptor has been synthesized. It shows a colorimetric and ratiometric fluorescent detection of zinc in aqueous solution. The ratiometric fluorescent change has been accounted to the conformational change of the probe. The ratiometric fluorescence change has been further supported by DFT/TDDFT calculations. The PDP-1 + Zn 2+ complex is also further successfully utilized for ratiometric fluorescence detection of pyrophosphate anions in buffered aqueous solution. The applicability of these probes for real sample analysis for the detection of Zn( ii ) and pyrophosphate ions has been also studied.</abstract><doi>10.1039/C3AY42057D</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1759-9660
ispartof Analytical methods, 2014-01, Vol.6 (7), p.2343-2348
issn 1759-9660
1759-9679
language eng
recordid cdi_proquest_miscellaneous_1520937634
source Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection
subjects Anions
Aqueous solutions
Buffers
Colorimetry
Fluorescence
Mathematical analysis
Receptors
Zinc
title Pyrene based selective–ratiometric fluorescent sensing of zinc and pyrophosphate ions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-14T06%3A20%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Pyrene%20based%20selective%E2%80%93ratiometric%20fluorescent%20sensing%20of%20zinc%20and%20pyrophosphate%20ions&rft.jtitle=Analytical%20methods&rft.au=Sivaraman,%20Gandhi&rft.date=2014-01-01&rft.volume=6&rft.issue=7&rft.spage=2343&rft.epage=2348&rft.pages=2343-2348&rft.issn=1759-9660&rft.eissn=1759-9679&rft_id=info:doi/10.1039/C3AY42057D&rft_dat=%3Cproquest_cross%3E1520937634%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1520937634&rft_id=info:pmid/&rfr_iscdi=true