Optimization of Multi-Pole Permanent Magnet Synchronous Generator Based 8 Blade Magnetically Levitated Variable Pitch Low Speed Vertical Axis Wind Turbine
The paper presents a new Vertical Axis Wind Turbine (VAWT) design by using magnetic levitation (Maglev) and Permanent Magnet Synchronous Generator (PMSG). A lab prototype of VAWT was built which was run at low wind speed of around 3 to 5 meter per second. The bearing was replaced by Neodymium Magnet...
Gespeichert in:
Veröffentlicht in: | Applied Mechanics and Materials 2014-01, Vol.492 (Power and Energy Systems III), p.113-117 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 117 |
---|---|
container_issue | Power and Energy Systems III |
container_start_page | 113 |
container_title | Applied Mechanics and Materials |
container_volume | 492 |
creator | Khan, M. Shahrukh Adnan Rajkumar, Rajprasad K. Rajkumar, Rajparthiban K. Aravind, C.V. |
description | The paper presents a new Vertical Axis Wind Turbine (VAWT) design by using magnetic levitation (Maglev) and Permanent Magnet Synchronous Generator (PMSG). A lab prototype of VAWT was built which was run at low wind speed of around 3 to 5 meter per second. The bearing was replaced by Neodymium Magnet to avoid the friction which in turns reduces the losses and increase the efficiency. A Prototype version of PMSG was built which could generate voltage from the turbine even in low rotational speed. Suitable turbine blade angle was also determined using trial and error method. |
doi_str_mv | 10.4028/www.scientific.net/AMM.492.113 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1520930755</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1520930755</sourcerecordid><originalsourceid>FETCH-LOGICAL-c389t-95d162a856a6277ec6741c9bf26c5f8dc803860220cd888663bf3d38688ffe533</originalsourceid><addsrcrecordid>eNqNkV1rFDEUhgc_wLb6HwKCeDPTfEwymRtxW2wVdmmhVS9DNnPipswma5Jx3f4Uf63ZbkHxyqtAzsP75uSpqjcENy2m8nS73TbJOPDZWWcaD_l0tlg0bU8bQtiT6ogIQeuulfRpdcww6yTve0KePQxw3TMmXlTHKd1hLFrSyqPq19Umu7W719kFj4JFi2nMrr4OI6BriGvtSxla6G-lC93svFnF4MOU0CV4iDqHiM50ggFJdDbqAR5RZ_Q47tAcfriscxl_0dHp5T7UZbNC87BFNxvYDyA-0Gj20yX01fkB3U5x6Ty8rJ5bPSZ49XieVJ8vPtyef6znV5efzmfz2jDZ57rnAxFUSy60oF0HRnQtMf3SUmG4lYORmEmBKcVmkFIKwZaWDeVKSmuBM3ZSvT3kbmL4PkHKau2SgXEsu5dNFeEU9wx3nBf09T_oXZiiL69TpO1ESzvekkK9O1AmhpQiWLWJbq3jThGs9h5V8aj-eFTlw1TxqIpHVTyWgPeHgBy1TxnM6q-e_4v4DfzYrg8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1476427541</pqid></control><display><type>article</type><title>Optimization of Multi-Pole Permanent Magnet Synchronous Generator Based 8 Blade Magnetically Levitated Variable Pitch Low Speed Vertical Axis Wind Turbine</title><source>Scientific.net Journals</source><creator>Khan, M. Shahrukh Adnan ; Rajkumar, Rajprasad K. ; Rajkumar, Rajparthiban K. ; Aravind, C.V.</creator><creatorcontrib>Khan, M. Shahrukh Adnan ; Rajkumar, Rajprasad K. ; Rajkumar, Rajparthiban K. ; Aravind, C.V.</creatorcontrib><description>The paper presents a new Vertical Axis Wind Turbine (VAWT) design by using magnetic levitation (Maglev) and Permanent Magnet Synchronous Generator (PMSG). A lab prototype of VAWT was built which was run at low wind speed of around 3 to 5 meter per second. The bearing was replaced by Neodymium Magnet to avoid the friction which in turns reduces the losses and increase the efficiency. A Prototype version of PMSG was built which could generate voltage from the turbine even in low rotational speed. Suitable turbine blade angle was also determined using trial and error method.</description><identifier>ISSN: 1660-9336</identifier><identifier>ISSN: 1662-7482</identifier><identifier>ISBN: 3037859911</identifier><identifier>ISBN: 9783037859919</identifier><identifier>EISSN: 1662-7482</identifier><identifier>DOI: 10.4028/www.scientific.net/AMM.492.113</identifier><language>eng</language><publisher>Zurich: Trans Tech Publications Ltd</publisher><subject>Generators ; Low speed ; Meters ; Permanent magnets ; Prototypes ; Synchronous ; Trial and error methods ; Vertical axis wind turbines</subject><ispartof>Applied Mechanics and Materials, 2014-01, Vol.492 (Power and Energy Systems III), p.113-117</ispartof><rights>2014 Trans Tech Publications Ltd</rights><rights>Copyright Trans Tech Publications Ltd. Jan 2014</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c389t-95d162a856a6277ec6741c9bf26c5f8dc803860220cd888663bf3d38688ffe533</citedby><cites>FETCH-LOGICAL-c389t-95d162a856a6277ec6741c9bf26c5f8dc803860220cd888663bf3d38688ffe533</cites><orcidid>0000-0002-2060-8748</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/2947?width=600</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Khan, M. Shahrukh Adnan</creatorcontrib><creatorcontrib>Rajkumar, Rajprasad K.</creatorcontrib><creatorcontrib>Rajkumar, Rajparthiban K.</creatorcontrib><creatorcontrib>Aravind, C.V.</creatorcontrib><title>Optimization of Multi-Pole Permanent Magnet Synchronous Generator Based 8 Blade Magnetically Levitated Variable Pitch Low Speed Vertical Axis Wind Turbine</title><title>Applied Mechanics and Materials</title><description>The paper presents a new Vertical Axis Wind Turbine (VAWT) design by using magnetic levitation (Maglev) and Permanent Magnet Synchronous Generator (PMSG). A lab prototype of VAWT was built which was run at low wind speed of around 3 to 5 meter per second. The bearing was replaced by Neodymium Magnet to avoid the friction which in turns reduces the losses and increase the efficiency. A Prototype version of PMSG was built which could generate voltage from the turbine even in low rotational speed. Suitable turbine blade angle was also determined using trial and error method.</description><subject>Generators</subject><subject>Low speed</subject><subject>Meters</subject><subject>Permanent magnets</subject><subject>Prototypes</subject><subject>Synchronous</subject><subject>Trial and error methods</subject><subject>Vertical axis wind turbines</subject><issn>1660-9336</issn><issn>1662-7482</issn><issn>1662-7482</issn><isbn>3037859911</isbn><isbn>9783037859919</isbn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNqNkV1rFDEUhgc_wLb6HwKCeDPTfEwymRtxW2wVdmmhVS9DNnPipswma5Jx3f4Uf63ZbkHxyqtAzsP75uSpqjcENy2m8nS73TbJOPDZWWcaD_l0tlg0bU8bQtiT6ogIQeuulfRpdcww6yTve0KePQxw3TMmXlTHKd1hLFrSyqPq19Umu7W719kFj4JFi2nMrr4OI6BriGvtSxla6G-lC93svFnF4MOU0CV4iDqHiM50ggFJdDbqAR5RZ_Q47tAcfriscxl_0dHp5T7UZbNC87BFNxvYDyA-0Gj20yX01fkB3U5x6Ty8rJ5bPSZ49XieVJ8vPtyef6znV5efzmfz2jDZ57rnAxFUSy60oF0HRnQtMf3SUmG4lYORmEmBKcVmkFIKwZaWDeVKSmuBM3ZSvT3kbmL4PkHKau2SgXEsu5dNFeEU9wx3nBf09T_oXZiiL69TpO1ESzvekkK9O1AmhpQiWLWJbq3jThGs9h5V8aj-eFTlw1TxqIpHVTyWgPeHgBy1TxnM6q-e_4v4DfzYrg8</recordid><startdate>20140101</startdate><enddate>20140101</enddate><creator>Khan, M. Shahrukh Adnan</creator><creator>Rajkumar, Rajprasad K.</creator><creator>Rajkumar, Rajparthiban K.</creator><creator>Aravind, C.V.</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7TB</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>BFMQW</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>FR3</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>KB.</scope><scope>KR7</scope><scope>L6V</scope><scope>M7S</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope><scope>7U5</scope><scope>H8D</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0002-2060-8748</orcidid></search><sort><creationdate>20140101</creationdate><title>Optimization of Multi-Pole Permanent Magnet Synchronous Generator Based 8 Blade Magnetically Levitated Variable Pitch Low Speed Vertical Axis Wind Turbine</title><author>Khan, M. Shahrukh Adnan ; Rajkumar, Rajprasad K. ; Rajkumar, Rajparthiban K. ; Aravind, C.V.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c389t-95d162a856a6277ec6741c9bf26c5f8dc803860220cd888663bf3d38688ffe533</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Generators</topic><topic>Low speed</topic><topic>Meters</topic><topic>Permanent magnets</topic><topic>Prototypes</topic><topic>Synchronous</topic><topic>Trial and error methods</topic><topic>Vertical axis wind turbines</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Khan, M. Shahrukh Adnan</creatorcontrib><creatorcontrib>Rajkumar, Rajprasad K.</creatorcontrib><creatorcontrib>Rajkumar, Rajparthiban K.</creatorcontrib><creatorcontrib>Aravind, C.V.</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>Continental Europe Database</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>Materials Science Database</collection><collection>Civil Engineering Abstracts</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Materials Science Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Applied Mechanics and Materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Khan, M. Shahrukh Adnan</au><au>Rajkumar, Rajprasad K.</au><au>Rajkumar, Rajparthiban K.</au><au>Aravind, C.V.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimization of Multi-Pole Permanent Magnet Synchronous Generator Based 8 Blade Magnetically Levitated Variable Pitch Low Speed Vertical Axis Wind Turbine</atitle><jtitle>Applied Mechanics and Materials</jtitle><date>2014-01-01</date><risdate>2014</risdate><volume>492</volume><issue>Power and Energy Systems III</issue><spage>113</spage><epage>117</epage><pages>113-117</pages><issn>1660-9336</issn><issn>1662-7482</issn><eissn>1662-7482</eissn><isbn>3037859911</isbn><isbn>9783037859919</isbn><abstract>The paper presents a new Vertical Axis Wind Turbine (VAWT) design by using magnetic levitation (Maglev) and Permanent Magnet Synchronous Generator (PMSG). A lab prototype of VAWT was built which was run at low wind speed of around 3 to 5 meter per second. The bearing was replaced by Neodymium Magnet to avoid the friction which in turns reduces the losses and increase the efficiency. A Prototype version of PMSG was built which could generate voltage from the turbine even in low rotational speed. Suitable turbine blade angle was also determined using trial and error method.</abstract><cop>Zurich</cop><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/AMM.492.113</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0002-2060-8748</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1660-9336 |
ispartof | Applied Mechanics and Materials, 2014-01, Vol.492 (Power and Energy Systems III), p.113-117 |
issn | 1660-9336 1662-7482 1662-7482 |
language | eng |
recordid | cdi_proquest_miscellaneous_1520930755 |
source | Scientific.net Journals |
subjects | Generators Low speed Meters Permanent magnets Prototypes Synchronous Trial and error methods Vertical axis wind turbines |
title | Optimization of Multi-Pole Permanent Magnet Synchronous Generator Based 8 Blade Magnetically Levitated Variable Pitch Low Speed Vertical Axis Wind Turbine |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T17%3A14%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimization%20of%20Multi-Pole%20Permanent%20Magnet%20Synchronous%20Generator%20Based%208%20Blade%20Magnetically%20Levitated%20Variable%20Pitch%20Low%20Speed%20Vertical%20Axis%20Wind%20Turbine&rft.jtitle=Applied%20Mechanics%20and%20Materials&rft.au=Khan,%20M.%20Shahrukh%20Adnan&rft.date=2014-01-01&rft.volume=492&rft.issue=Power%20and%20Energy%20Systems%20III&rft.spage=113&rft.epage=117&rft.pages=113-117&rft.issn=1660-9336&rft.eissn=1662-7482&rft.isbn=3037859911&rft.isbn_list=9783037859919&rft_id=info:doi/10.4028/www.scientific.net/AMM.492.113&rft_dat=%3Cproquest_cross%3E1520930755%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1476427541&rft_id=info:pmid/&rfr_iscdi=true |