An improved highly sensitive method to determine low oxyresveratrol concentrations in rat plasma and its pharmacokinetic application

ABSTRACT Existing methods to determine oxyresveratrol, a trans‐polyphenolic stilbene, lack selectivity, require large plasma sample volumes or have time‐consuming sample preparation and chromatographic isolation. Here an improved highly sensitive liquid chromatography–tandem mass spectrometry method...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biomedical chromatography 2014-05, Vol.28 (5), p.667-672
Hauptverfasser: Tian, Fangzhen, Wei, Hongtu, Jia, Tanghong, Tian, Hua
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 672
container_issue 5
container_start_page 667
container_title Biomedical chromatography
container_volume 28
creator Tian, Fangzhen
Wei, Hongtu
Jia, Tanghong
Tian, Hua
description ABSTRACT Existing methods to determine oxyresveratrol, a trans‐polyphenolic stilbene, lack selectivity, require large plasma sample volumes or have time‐consuming sample preparation and chromatographic isolation. Here an improved highly sensitive liquid chromatography–tandem mass spectrometry method was developed to determine low oxyresveratrol concentrations in rat plasma. The plasma samples were prepared by liquid–liquid extraction with acetoacetate. The analytes were separated on Venusil hydrophilic interaction chromatography (HILIC) column (2.1 × 50 mm, 5.0 µm) guarded by a HILIC column (4 × 3.0 mm, 5.0 µm). The mobile phase consisted of acetonitrile–water (containing 1 mmol/L ammonium formate) at gradient elution mode with a flow rate of 0.3 mL/min. Resveratrol was used as the internal standard. An electrospray ionization source was applied and operated in the negative multiple reaction monitoring (MRM) mode. Oxyresveratrol and resveratrol were detected on MRM by the transitions from the precursor to the product ion (m/z 243.1 → 175.1 and 227.1 → 143.0). The total running time was 5 min and the retention times of oxyresveratrol and resveratrol were 1.97 and 1.82 min. Chromatograms showed no endogenous interfering peaks with blank samples. The linear calibration curve was obtained over the concentration range of 1–500 ng/mL. The injection volume was 10 μL and the limit of quantification was 1 ng/mL. The extraction recovery varied from 78.2 to 84.3% for low, medium and high quality control samples. At the same time, the intra‐ and inter‐day relative standard deviations were
doi_str_mv 10.1002/bmc.3087
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1516723764</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1516723764</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3597-153fd949eac0895e9223c01b69d75a8403bb69fa0abd455997187adb8b277933</originalsourceid><addsrcrecordid>eNp1kE1vEzEQhi0EoqEg8QuQj1y29cd6vT6WqASkUoRUgcTF8toTYuq1F9tJmzs_nG0byonTvCM980jzIvSakhNKCDsdRnvCSS-foAUlSjWkJ_QpWhDWqYb3Uh2hF6X8JISojsnn6Ii1nEnB5QL9PovYj1NOO3B4439swh4XiMVXvwM8Qt0kh2vCDirk0UfAId3gdLvPUHaQTc0pYJuihVjnzadYsI94jngKpowGm-iwrwVPG5NHY9P1LKneYjNNwdv7k5fo2dqEAq8O8xhdvT-_Wn5oLj6vPi7PLhrLhZINFXztVKvAWNIrAYoxbgkdOuWkMH1L-DDntSFmcK0QSknaS-OGfmBSKs6P0dsH7fzury2UqkdfLIRgIqRt0VTQTjIuu_YfanMqJcNaT9mPJu81Jfqucj1Xru8qn9E3B-t2GME9gn87noHmAbjxAfb_Fel3n5YH4YH3pcLtI2_yte4kl0J_u1zpr10vvny_bPWK_wEDK5xd</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1516723764</pqid></control><display><type>article</type><title>An improved highly sensitive method to determine low oxyresveratrol concentrations in rat plasma and its pharmacokinetic application</title><source>MEDLINE</source><source>Access via Wiley Online Library</source><creator>Tian, Fangzhen ; Wei, Hongtu ; Jia, Tanghong ; Tian, Hua</creator><creatorcontrib>Tian, Fangzhen ; Wei, Hongtu ; Jia, Tanghong ; Tian, Hua</creatorcontrib><description>ABSTRACT Existing methods to determine oxyresveratrol, a trans‐polyphenolic stilbene, lack selectivity, require large plasma sample volumes or have time‐consuming sample preparation and chromatographic isolation. Here an improved highly sensitive liquid chromatography–tandem mass spectrometry method was developed to determine low oxyresveratrol concentrations in rat plasma. The plasma samples were prepared by liquid–liquid extraction with acetoacetate. The analytes were separated on Venusil hydrophilic interaction chromatography (HILIC) column (2.1 × 50 mm, 5.0 µm) guarded by a HILIC column (4 × 3.0 mm, 5.0 µm). The mobile phase consisted of acetonitrile–water (containing 1 mmol/L ammonium formate) at gradient elution mode with a flow rate of 0.3 mL/min. Resveratrol was used as the internal standard. An electrospray ionization source was applied and operated in the negative multiple reaction monitoring (MRM) mode. Oxyresveratrol and resveratrol were detected on MRM by the transitions from the precursor to the product ion (m/z 243.1 → 175.1 and 227.1 → 143.0). The total running time was 5 min and the retention times of oxyresveratrol and resveratrol were 1.97 and 1.82 min. Chromatograms showed no endogenous interfering peaks with blank samples. The linear calibration curve was obtained over the concentration range of 1–500 ng/mL. The injection volume was 10 μL and the limit of quantification was 1 ng/mL. The extraction recovery varied from 78.2 to 84.3% for low, medium and high quality control samples. At the same time, the intra‐ and inter‐day relative standard deviations were &lt;6.78 and &lt;10.02%, respectively, while the corresponding intra‐ and inter‐day accuracy relative error values fell in the range of 3.75–6.67%. The HPLC‐MS/MS method was successfully applied to a pharmacokinetics study, in which the experimental rats received a single dose of oxyresveratrol (10 mg/kg, intragastric administration). The pharmacokinetic results are presented. Copyright © 2013 John Wiley &amp; Sons, Ltd.</description><identifier>ISSN: 0269-3879</identifier><identifier>EISSN: 1099-0801</identifier><identifier>DOI: 10.1002/bmc.3087</identifier><identifier>PMID: 24327537</identifier><language>eng</language><publisher>England: Blackwell Publishing Ltd</publisher><subject>Animals ; Chromatography, Liquid - methods ; LC-MS/MS ; Male ; oxyresveratrol ; pharmacokinetics ; rat plasma ; Rats ; Rats, Sprague-Dawley ; Sensitivity and Specificity ; Stilbenes - blood ; Stilbenes - pharmacokinetics</subject><ispartof>Biomedical chromatography, 2014-05, Vol.28 (5), p.667-672</ispartof><rights>Copyright © 2013 John Wiley &amp; Sons, Ltd.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3597-153fd949eac0895e9223c01b69d75a8403bb69fa0abd455997187adb8b277933</citedby><cites>FETCH-LOGICAL-c3597-153fd949eac0895e9223c01b69d75a8403bb69fa0abd455997187adb8b277933</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fbmc.3087$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fbmc.3087$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24327537$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Tian, Fangzhen</creatorcontrib><creatorcontrib>Wei, Hongtu</creatorcontrib><creatorcontrib>Jia, Tanghong</creatorcontrib><creatorcontrib>Tian, Hua</creatorcontrib><title>An improved highly sensitive method to determine low oxyresveratrol concentrations in rat plasma and its pharmacokinetic application</title><title>Biomedical chromatography</title><addtitle>Biomed. Chromatogr</addtitle><description>ABSTRACT Existing methods to determine oxyresveratrol, a trans‐polyphenolic stilbene, lack selectivity, require large plasma sample volumes or have time‐consuming sample preparation and chromatographic isolation. Here an improved highly sensitive liquid chromatography–tandem mass spectrometry method was developed to determine low oxyresveratrol concentrations in rat plasma. The plasma samples were prepared by liquid–liquid extraction with acetoacetate. The analytes were separated on Venusil hydrophilic interaction chromatography (HILIC) column (2.1 × 50 mm, 5.0 µm) guarded by a HILIC column (4 × 3.0 mm, 5.0 µm). The mobile phase consisted of acetonitrile–water (containing 1 mmol/L ammonium formate) at gradient elution mode with a flow rate of 0.3 mL/min. Resveratrol was used as the internal standard. An electrospray ionization source was applied and operated in the negative multiple reaction monitoring (MRM) mode. Oxyresveratrol and resveratrol were detected on MRM by the transitions from the precursor to the product ion (m/z 243.1 → 175.1 and 227.1 → 143.0). The total running time was 5 min and the retention times of oxyresveratrol and resveratrol were 1.97 and 1.82 min. Chromatograms showed no endogenous interfering peaks with blank samples. The linear calibration curve was obtained over the concentration range of 1–500 ng/mL. The injection volume was 10 μL and the limit of quantification was 1 ng/mL. The extraction recovery varied from 78.2 to 84.3% for low, medium and high quality control samples. At the same time, the intra‐ and inter‐day relative standard deviations were &lt;6.78 and &lt;10.02%, respectively, while the corresponding intra‐ and inter‐day accuracy relative error values fell in the range of 3.75–6.67%. The HPLC‐MS/MS method was successfully applied to a pharmacokinetics study, in which the experimental rats received a single dose of oxyresveratrol (10 mg/kg, intragastric administration). The pharmacokinetic results are presented. Copyright © 2013 John Wiley &amp; Sons, Ltd.</description><subject>Animals</subject><subject>Chromatography, Liquid - methods</subject><subject>LC-MS/MS</subject><subject>Male</subject><subject>oxyresveratrol</subject><subject>pharmacokinetics</subject><subject>rat plasma</subject><subject>Rats</subject><subject>Rats, Sprague-Dawley</subject><subject>Sensitivity and Specificity</subject><subject>Stilbenes - blood</subject><subject>Stilbenes - pharmacokinetics</subject><issn>0269-3879</issn><issn>1099-0801</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kE1vEzEQhi0EoqEg8QuQj1y29cd6vT6WqASkUoRUgcTF8toTYuq1F9tJmzs_nG0byonTvCM980jzIvSakhNKCDsdRnvCSS-foAUlSjWkJ_QpWhDWqYb3Uh2hF6X8JISojsnn6Ii1nEnB5QL9PovYj1NOO3B4439swh4XiMVXvwM8Qt0kh2vCDirk0UfAId3gdLvPUHaQTc0pYJuihVjnzadYsI94jngKpowGm-iwrwVPG5NHY9P1LKneYjNNwdv7k5fo2dqEAq8O8xhdvT-_Wn5oLj6vPi7PLhrLhZINFXztVKvAWNIrAYoxbgkdOuWkMH1L-DDntSFmcK0QSknaS-OGfmBSKs6P0dsH7fzury2UqkdfLIRgIqRt0VTQTjIuu_YfanMqJcNaT9mPJu81Jfqucj1Xru8qn9E3B-t2GME9gn87noHmAbjxAfb_Fel3n5YH4YH3pcLtI2_yte4kl0J_u1zpr10vvny_bPWK_wEDK5xd</recordid><startdate>201405</startdate><enddate>201405</enddate><creator>Tian, Fangzhen</creator><creator>Wei, Hongtu</creator><creator>Jia, Tanghong</creator><creator>Tian, Hua</creator><general>Blackwell Publishing Ltd</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201405</creationdate><title>An improved highly sensitive method to determine low oxyresveratrol concentrations in rat plasma and its pharmacokinetic application</title><author>Tian, Fangzhen ; Wei, Hongtu ; Jia, Tanghong ; Tian, Hua</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3597-153fd949eac0895e9223c01b69d75a8403bb69fa0abd455997187adb8b277933</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Animals</topic><topic>Chromatography, Liquid - methods</topic><topic>LC-MS/MS</topic><topic>Male</topic><topic>oxyresveratrol</topic><topic>pharmacokinetics</topic><topic>rat plasma</topic><topic>Rats</topic><topic>Rats, Sprague-Dawley</topic><topic>Sensitivity and Specificity</topic><topic>Stilbenes - blood</topic><topic>Stilbenes - pharmacokinetics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tian, Fangzhen</creatorcontrib><creatorcontrib>Wei, Hongtu</creatorcontrib><creatorcontrib>Jia, Tanghong</creatorcontrib><creatorcontrib>Tian, Hua</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Biomedical chromatography</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tian, Fangzhen</au><au>Wei, Hongtu</au><au>Jia, Tanghong</au><au>Tian, Hua</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An improved highly sensitive method to determine low oxyresveratrol concentrations in rat plasma and its pharmacokinetic application</atitle><jtitle>Biomedical chromatography</jtitle><addtitle>Biomed. Chromatogr</addtitle><date>2014-05</date><risdate>2014</risdate><volume>28</volume><issue>5</issue><spage>667</spage><epage>672</epage><pages>667-672</pages><issn>0269-3879</issn><eissn>1099-0801</eissn><abstract>ABSTRACT Existing methods to determine oxyresveratrol, a trans‐polyphenolic stilbene, lack selectivity, require large plasma sample volumes or have time‐consuming sample preparation and chromatographic isolation. Here an improved highly sensitive liquid chromatography–tandem mass spectrometry method was developed to determine low oxyresveratrol concentrations in rat plasma. The plasma samples were prepared by liquid–liquid extraction with acetoacetate. The analytes were separated on Venusil hydrophilic interaction chromatography (HILIC) column (2.1 × 50 mm, 5.0 µm) guarded by a HILIC column (4 × 3.0 mm, 5.0 µm). The mobile phase consisted of acetonitrile–water (containing 1 mmol/L ammonium formate) at gradient elution mode with a flow rate of 0.3 mL/min. Resveratrol was used as the internal standard. An electrospray ionization source was applied and operated in the negative multiple reaction monitoring (MRM) mode. Oxyresveratrol and resveratrol were detected on MRM by the transitions from the precursor to the product ion (m/z 243.1 → 175.1 and 227.1 → 143.0). The total running time was 5 min and the retention times of oxyresveratrol and resveratrol were 1.97 and 1.82 min. Chromatograms showed no endogenous interfering peaks with blank samples. The linear calibration curve was obtained over the concentration range of 1–500 ng/mL. The injection volume was 10 μL and the limit of quantification was 1 ng/mL. The extraction recovery varied from 78.2 to 84.3% for low, medium and high quality control samples. At the same time, the intra‐ and inter‐day relative standard deviations were &lt;6.78 and &lt;10.02%, respectively, while the corresponding intra‐ and inter‐day accuracy relative error values fell in the range of 3.75–6.67%. The HPLC‐MS/MS method was successfully applied to a pharmacokinetics study, in which the experimental rats received a single dose of oxyresveratrol (10 mg/kg, intragastric administration). The pharmacokinetic results are presented. Copyright © 2013 John Wiley &amp; Sons, Ltd.</abstract><cop>England</cop><pub>Blackwell Publishing Ltd</pub><pmid>24327537</pmid><doi>10.1002/bmc.3087</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0269-3879
ispartof Biomedical chromatography, 2014-05, Vol.28 (5), p.667-672
issn 0269-3879
1099-0801
language eng
recordid cdi_proquest_miscellaneous_1516723764
source MEDLINE; Access via Wiley Online Library
subjects Animals
Chromatography, Liquid - methods
LC-MS/MS
Male
oxyresveratrol
pharmacokinetics
rat plasma
Rats
Rats, Sprague-Dawley
Sensitivity and Specificity
Stilbenes - blood
Stilbenes - pharmacokinetics
title An improved highly sensitive method to determine low oxyresveratrol concentrations in rat plasma and its pharmacokinetic application
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T17%3A33%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20improved%20highly%20sensitive%20method%20to%20determine%20low%20oxyresveratrol%20concentrations%20in%20rat%20plasma%20and%20its%20pharmacokinetic%20application&rft.jtitle=Biomedical%20chromatography&rft.au=Tian,%20Fangzhen&rft.date=2014-05&rft.volume=28&rft.issue=5&rft.spage=667&rft.epage=672&rft.pages=667-672&rft.issn=0269-3879&rft.eissn=1099-0801&rft_id=info:doi/10.1002/bmc.3087&rft_dat=%3Cproquest_cross%3E1516723764%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1516723764&rft_id=info:pmid/24327537&rfr_iscdi=true