Utility of Live/Real Time Three-Dimensional Transesophageal Echocardiography in the Assessment and Percutaneous Intervention of Bioprosthetic Pulmonary Valve Stenosis

Accurate echocardiographic evaluation of the pulmonary valve is technically difficult because of its close proximity to the left lung, which often limits decision making. Pulmonary valvotomy is the intervention of choice for symptomatic pulmonary valve stenosis, but fluoroscopy lacks appropriate rea...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Echocardiography (Mount Kisco, N.Y.) N.Y.), 2014-04, Vol.31 (4), p.531-533
Hauptverfasser: Ahmed, Mustafa I., Escañuela, Maximiliano German Amado, Crosland, William A., McMahon, William S., Alli, Oluseun O., Nanda, Navin C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 533
container_issue 4
container_start_page 531
container_title Echocardiography (Mount Kisco, N.Y.)
container_volume 31
creator Ahmed, Mustafa I.
Escañuela, Maximiliano German Amado
Crosland, William A.
McMahon, William S.
Alli, Oluseun O.
Nanda, Navin C.
description Accurate echocardiographic evaluation of the pulmonary valve is technically difficult because of its close proximity to the left lung, which often limits decision making. Pulmonary valvotomy is the intervention of choice for symptomatic pulmonary valve stenosis, but fluoroscopy lacks appropriate real time anatomic detail. In this report, we present a case where direct imaging of the pulmonary valve with live/real time three‐dimensional transesophageal echocardiography (3DTEE) aided in accurate evaluation and was then used to help guide and monitor successful valvuloplasty of a stenotic pulmonary valve bioprosthesis. We demonstrate that even in cases where two‐dimensional (2D) evaluation of the pulmonary valve is difficult, the use of live/real time 3DTEE allows for accurate evaluation of bioprosthetic pulmonary valve structure and function, and enhances the precision and monitoring of percutaneous valvuloplasty.
doi_str_mv 10.1111/echo.12551
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1514427805</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1514427805</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3671-dfee14c4e899975728148c50287961c65d2a067e58d85669cb0cadff20fd662f3</originalsourceid><addsrcrecordid>eNp9kc1uEzEUhS0EoqGw4QGQlwhpWtvjn5llSUNTEWgFaVharudOxzA_wXYCeSGeEw_Tdok3tq6_c-6RDkKvKTmh6ZyCbYYTyoSgT9CMCk6ygirxFM2I4ixjBWNH6EUI3wkhilL-HB0xLrkkTM3Qn5voWhcPeKjxyu3h9AuYFq9dB3jdeIDsPD374IZ-HHvTBwjDtjF3I7ZIi63xlRvuvNk2B-x6HBvAZyFRIekiNn2Fr8HbXTQ9DLuAL_sIfp--kuW49L0btn4ISRadxde7tkur_AFvTLsH_DVCPwQXXqJntWkDvLq_j9HNh8V6vsxWVxeX87NVZnOpaFbVAJRbDkVZlkooVlBeWEFYoUpJrRQVM0QqEEVVCClLe0usqeqakbqSktX5MXo7-aZMP3cQou5csNC2U3pNBeWcqYKIhL6bUJviBw-13nrXpeiaEj32osde9L9eEvzm3nd320H1iD4UkQA6Ab9cC4f_WOnFfHn1YJpNGhci_H7UGP9DS5Urob99vtBLsfn4aVPkmuR_AZUKqvI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1514427805</pqid></control><display><type>article</type><title>Utility of Live/Real Time Three-Dimensional Transesophageal Echocardiography in the Assessment and Percutaneous Intervention of Bioprosthetic Pulmonary Valve Stenosis</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><creator>Ahmed, Mustafa I. ; Escañuela, Maximiliano German Amado ; Crosland, William A. ; McMahon, William S. ; Alli, Oluseun O. ; Nanda, Navin C.</creator><creatorcontrib>Ahmed, Mustafa I. ; Escañuela, Maximiliano German Amado ; Crosland, William A. ; McMahon, William S. ; Alli, Oluseun O. ; Nanda, Navin C.</creatorcontrib><description>Accurate echocardiographic evaluation of the pulmonary valve is technically difficult because of its close proximity to the left lung, which often limits decision making. Pulmonary valvotomy is the intervention of choice for symptomatic pulmonary valve stenosis, but fluoroscopy lacks appropriate real time anatomic detail. In this report, we present a case where direct imaging of the pulmonary valve with live/real time three‐dimensional transesophageal echocardiography (3DTEE) aided in accurate evaluation and was then used to help guide and monitor successful valvuloplasty of a stenotic pulmonary valve bioprosthesis. We demonstrate that even in cases where two‐dimensional (2D) evaluation of the pulmonary valve is difficult, the use of live/real time 3DTEE allows for accurate evaluation of bioprosthetic pulmonary valve structure and function, and enhances the precision and monitoring of percutaneous valvuloplasty.</description><identifier>ISSN: 0742-2822</identifier><identifier>EISSN: 1540-8175</identifier><identifier>DOI: 10.1111/echo.12551</identifier><identifier>PMID: 24646027</identifier><language>eng</language><publisher>United States: Blackwell Publishing Ltd</publisher><subject>Bioprosthesis ; Cardiac Catheterization ; echocardiography ; Echocardiography, Three-Dimensional - utilization ; Echocardiography, Transesophageal - methods ; Female ; Follow-Up Studies ; Heart Valve Prosthesis ; Heart Valve Prosthesis Implantation - adverse effects ; Heart Valve Prosthesis Implantation - methods ; Humans ; Middle Aged ; Minimally Invasive Surgical Procedures - methods ; Prosthesis Failure ; prosthetic valve ; pulmonary valve ; pulmonary valve prosthesis ; pulmonary valve stenosis ; Pulmonary Valve Stenosis - congenital ; Pulmonary Valve Stenosis - diagnostic imaging ; Pulmonary Valve Stenosis - surgery ; Reoperation - methods ; Risk Assessment ; Severity of Illness Index ; three-dimensional echocardiography ; three-dimensional transesophageal echocardiography ; Treatment Outcome</subject><ispartof>Echocardiography (Mount Kisco, N.Y.), 2014-04, Vol.31 (4), p.531-533</ispartof><rights>2014, Wiley Periodicals, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3671-dfee14c4e899975728148c50287961c65d2a067e58d85669cb0cadff20fd662f3</citedby><cites>FETCH-LOGICAL-c3671-dfee14c4e899975728148c50287961c65d2a067e58d85669cb0cadff20fd662f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1111%2Fecho.12551$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1111%2Fecho.12551$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,777,781,1412,27905,27906,45555,45556</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24646027$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ahmed, Mustafa I.</creatorcontrib><creatorcontrib>Escañuela, Maximiliano German Amado</creatorcontrib><creatorcontrib>Crosland, William A.</creatorcontrib><creatorcontrib>McMahon, William S.</creatorcontrib><creatorcontrib>Alli, Oluseun O.</creatorcontrib><creatorcontrib>Nanda, Navin C.</creatorcontrib><title>Utility of Live/Real Time Three-Dimensional Transesophageal Echocardiography in the Assessment and Percutaneous Intervention of Bioprosthetic Pulmonary Valve Stenosis</title><title>Echocardiography (Mount Kisco, N.Y.)</title><addtitle>Echocardiography</addtitle><description>Accurate echocardiographic evaluation of the pulmonary valve is technically difficult because of its close proximity to the left lung, which often limits decision making. Pulmonary valvotomy is the intervention of choice for symptomatic pulmonary valve stenosis, but fluoroscopy lacks appropriate real time anatomic detail. In this report, we present a case where direct imaging of the pulmonary valve with live/real time three‐dimensional transesophageal echocardiography (3DTEE) aided in accurate evaluation and was then used to help guide and monitor successful valvuloplasty of a stenotic pulmonary valve bioprosthesis. We demonstrate that even in cases where two‐dimensional (2D) evaluation of the pulmonary valve is difficult, the use of live/real time 3DTEE allows for accurate evaluation of bioprosthetic pulmonary valve structure and function, and enhances the precision and monitoring of percutaneous valvuloplasty.</description><subject>Bioprosthesis</subject><subject>Cardiac Catheterization</subject><subject>echocardiography</subject><subject>Echocardiography, Three-Dimensional - utilization</subject><subject>Echocardiography, Transesophageal - methods</subject><subject>Female</subject><subject>Follow-Up Studies</subject><subject>Heart Valve Prosthesis</subject><subject>Heart Valve Prosthesis Implantation - adverse effects</subject><subject>Heart Valve Prosthesis Implantation - methods</subject><subject>Humans</subject><subject>Middle Aged</subject><subject>Minimally Invasive Surgical Procedures - methods</subject><subject>Prosthesis Failure</subject><subject>prosthetic valve</subject><subject>pulmonary valve</subject><subject>pulmonary valve prosthesis</subject><subject>pulmonary valve stenosis</subject><subject>Pulmonary Valve Stenosis - congenital</subject><subject>Pulmonary Valve Stenosis - diagnostic imaging</subject><subject>Pulmonary Valve Stenosis - surgery</subject><subject>Reoperation - methods</subject><subject>Risk Assessment</subject><subject>Severity of Illness Index</subject><subject>three-dimensional echocardiography</subject><subject>three-dimensional transesophageal echocardiography</subject><subject>Treatment Outcome</subject><issn>0742-2822</issn><issn>1540-8175</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kc1uEzEUhS0EoqGw4QGQlwhpWtvjn5llSUNTEWgFaVharudOxzA_wXYCeSGeEw_Tdok3tq6_c-6RDkKvKTmh6ZyCbYYTyoSgT9CMCk6ygirxFM2I4ixjBWNH6EUI3wkhilL-HB0xLrkkTM3Qn5voWhcPeKjxyu3h9AuYFq9dB3jdeIDsPD374IZ-HHvTBwjDtjF3I7ZIi63xlRvuvNk2B-x6HBvAZyFRIekiNn2Fr8HbXTQ9DLuAL_sIfp--kuW49L0btn4ISRadxde7tkur_AFvTLsH_DVCPwQXXqJntWkDvLq_j9HNh8V6vsxWVxeX87NVZnOpaFbVAJRbDkVZlkooVlBeWEFYoUpJrRQVM0QqEEVVCClLe0usqeqakbqSktX5MXo7-aZMP3cQou5csNC2U3pNBeWcqYKIhL6bUJviBw-13nrXpeiaEj32osde9L9eEvzm3nd320H1iD4UkQA6Ab9cC4f_WOnFfHn1YJpNGhci_H7UGP9DS5Urob99vtBLsfn4aVPkmuR_AZUKqvI</recordid><startdate>201404</startdate><enddate>201404</enddate><creator>Ahmed, Mustafa I.</creator><creator>Escañuela, Maximiliano German Amado</creator><creator>Crosland, William A.</creator><creator>McMahon, William S.</creator><creator>Alli, Oluseun O.</creator><creator>Nanda, Navin C.</creator><general>Blackwell Publishing Ltd</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201404</creationdate><title>Utility of Live/Real Time Three-Dimensional Transesophageal Echocardiography in the Assessment and Percutaneous Intervention of Bioprosthetic Pulmonary Valve Stenosis</title><author>Ahmed, Mustafa I. ; Escañuela, Maximiliano German Amado ; Crosland, William A. ; McMahon, William S. ; Alli, Oluseun O. ; Nanda, Navin C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3671-dfee14c4e899975728148c50287961c65d2a067e58d85669cb0cadff20fd662f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Bioprosthesis</topic><topic>Cardiac Catheterization</topic><topic>echocardiography</topic><topic>Echocardiography, Three-Dimensional - utilization</topic><topic>Echocardiography, Transesophageal - methods</topic><topic>Female</topic><topic>Follow-Up Studies</topic><topic>Heart Valve Prosthesis</topic><topic>Heart Valve Prosthesis Implantation - adverse effects</topic><topic>Heart Valve Prosthesis Implantation - methods</topic><topic>Humans</topic><topic>Middle Aged</topic><topic>Minimally Invasive Surgical Procedures - methods</topic><topic>Prosthesis Failure</topic><topic>prosthetic valve</topic><topic>pulmonary valve</topic><topic>pulmonary valve prosthesis</topic><topic>pulmonary valve stenosis</topic><topic>Pulmonary Valve Stenosis - congenital</topic><topic>Pulmonary Valve Stenosis - diagnostic imaging</topic><topic>Pulmonary Valve Stenosis - surgery</topic><topic>Reoperation - methods</topic><topic>Risk Assessment</topic><topic>Severity of Illness Index</topic><topic>three-dimensional echocardiography</topic><topic>three-dimensional transesophageal echocardiography</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ahmed, Mustafa I.</creatorcontrib><creatorcontrib>Escañuela, Maximiliano German Amado</creatorcontrib><creatorcontrib>Crosland, William A.</creatorcontrib><creatorcontrib>McMahon, William S.</creatorcontrib><creatorcontrib>Alli, Oluseun O.</creatorcontrib><creatorcontrib>Nanda, Navin C.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Echocardiography (Mount Kisco, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ahmed, Mustafa I.</au><au>Escañuela, Maximiliano German Amado</au><au>Crosland, William A.</au><au>McMahon, William S.</au><au>Alli, Oluseun O.</au><au>Nanda, Navin C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Utility of Live/Real Time Three-Dimensional Transesophageal Echocardiography in the Assessment and Percutaneous Intervention of Bioprosthetic Pulmonary Valve Stenosis</atitle><jtitle>Echocardiography (Mount Kisco, N.Y.)</jtitle><addtitle>Echocardiography</addtitle><date>2014-04</date><risdate>2014</risdate><volume>31</volume><issue>4</issue><spage>531</spage><epage>533</epage><pages>531-533</pages><issn>0742-2822</issn><eissn>1540-8175</eissn><abstract>Accurate echocardiographic evaluation of the pulmonary valve is technically difficult because of its close proximity to the left lung, which often limits decision making. Pulmonary valvotomy is the intervention of choice for symptomatic pulmonary valve stenosis, but fluoroscopy lacks appropriate real time anatomic detail. In this report, we present a case where direct imaging of the pulmonary valve with live/real time three‐dimensional transesophageal echocardiography (3DTEE) aided in accurate evaluation and was then used to help guide and monitor successful valvuloplasty of a stenotic pulmonary valve bioprosthesis. We demonstrate that even in cases where two‐dimensional (2D) evaluation of the pulmonary valve is difficult, the use of live/real time 3DTEE allows for accurate evaluation of bioprosthetic pulmonary valve structure and function, and enhances the precision and monitoring of percutaneous valvuloplasty.</abstract><cop>United States</cop><pub>Blackwell Publishing Ltd</pub><pmid>24646027</pmid><doi>10.1111/echo.12551</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0742-2822
ispartof Echocardiography (Mount Kisco, N.Y.), 2014-04, Vol.31 (4), p.531-533
issn 0742-2822
1540-8175
language eng
recordid cdi_proquest_miscellaneous_1514427805
source MEDLINE; Wiley Online Library Journals Frontfile Complete
subjects Bioprosthesis
Cardiac Catheterization
echocardiography
Echocardiography, Three-Dimensional - utilization
Echocardiography, Transesophageal - methods
Female
Follow-Up Studies
Heart Valve Prosthesis
Heart Valve Prosthesis Implantation - adverse effects
Heart Valve Prosthesis Implantation - methods
Humans
Middle Aged
Minimally Invasive Surgical Procedures - methods
Prosthesis Failure
prosthetic valve
pulmonary valve
pulmonary valve prosthesis
pulmonary valve stenosis
Pulmonary Valve Stenosis - congenital
Pulmonary Valve Stenosis - diagnostic imaging
Pulmonary Valve Stenosis - surgery
Reoperation - methods
Risk Assessment
Severity of Illness Index
three-dimensional echocardiography
three-dimensional transesophageal echocardiography
Treatment Outcome
title Utility of Live/Real Time Three-Dimensional Transesophageal Echocardiography in the Assessment and Percutaneous Intervention of Bioprosthetic Pulmonary Valve Stenosis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T17%3A07%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Utility%20of%20Live/Real%20Time%20Three-Dimensional%20Transesophageal%20Echocardiography%20in%20the%20Assessment%20and%20Percutaneous%20Intervention%20of%20Bioprosthetic%20Pulmonary%20Valve%20Stenosis&rft.jtitle=Echocardiography%20(Mount%20Kisco,%20N.Y.)&rft.au=Ahmed,%20Mustafa%20I.&rft.date=2014-04&rft.volume=31&rft.issue=4&rft.spage=531&rft.epage=533&rft.pages=531-533&rft.issn=0742-2822&rft.eissn=1540-8175&rft_id=info:doi/10.1111/echo.12551&rft_dat=%3Cproquest_cross%3E1514427805%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1514427805&rft_id=info:pmid/24646027&rfr_iscdi=true