Comparison between experimental and 2-D numerical studies of multiple scattering in Inconel600ARG by means of array probes

Ultrasonic non-destructive testing of polycrystalline structures can be disturbed by scattering at grain boundaries. Understanding and modeling this so-called astructural noisea is crucial for characterization as well as detection purposes. Structural noise can be considered as a fingerprint of the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ultrasonics 2014-01, Vol.54 (1), p.358-367
Hauptverfasser: Shahjahan, S, Rupin, F, Aubry, A, Chassignole, B, Fouquet, T, Derode, A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 367
container_issue 1
container_start_page 358
container_title Ultrasonics
container_volume 54
creator Shahjahan, S
Rupin, F
Aubry, A
Chassignole, B
Fouquet, T
Derode, A
description Ultrasonic non-destructive testing of polycrystalline structures can be disturbed by scattering at grain boundaries. Understanding and modeling this so-called astructural noisea is crucial for characterization as well as detection purposes. Structural noise can be considered as a fingerprint of the material under investigation, since it contains information about its microstructure. The interpretation of experimental data necessitates an accurate comprehension of complex phenomena that occur in multiple scattering media and thus robust scattering models. In particular, numerical models can offer the opportunity to realize parametrical studies on controlled microstructures. However, the ability of the model to simulate wave propagation in complex media must be validated. In that perspective, the main objective of the present work is to evaluate the ability of the finite-element code ATHENA 2D to reproduce typical features of multiple wave scattering in the context of ultrasonic non-destructive evaluation, with an array of sources and receivers. Experiments were carried out with a 64-element array, around 2 MHz. The sample was a mock-up of Inconel600ARG exhibiting a coarse grain structure with a known grain size distribution. The numerical model of this microstructure is based on Voronoi diagrams. Two physical parameters were used to compare numerical and experimental data: the coherent backscattering peak, and the singular value distribution of the array response matrix. Though the simulations are 2-D, a good agreement was found between simulated and experimental data.
doi_str_mv 10.1016/j.ultras.2013.06.012
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_1513428758</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1513428758</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_15134287583</originalsourceid><addsrcrecordid>eNqVjc1OwzAQhH0AiUL7Bhz2yCVh7aQhV1R-r4gDt8pJt8iVvQ5eR1CeHgvxApxG-r4ZjVKXGmuNurs-1LPPyUptUDc1djVqc6IWiK2uOtO-nalzkQOibnvdLNT3JobJJieRYaD8ScRAXxMlF4iz9WB5B6a6A55DgWMhkuedI4G4h1C-3OQJZLQ5F8_v4BieeYxMvkO8fXmE4QiBLP8ObEr2CFOKA8lSne6tF1r95YW6erh_3TxVRX_MJHkbnIzkvWWKs2z1Wjet6W_WffOP6g8o1Vip</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1513428758</pqid></control><display><type>article</type><title>Comparison between experimental and 2-D numerical studies of multiple scattering in Inconel600ARG by means of array probes</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Shahjahan, S ; Rupin, F ; Aubry, A ; Chassignole, B ; Fouquet, T ; Derode, A</creator><creatorcontrib>Shahjahan, S ; Rupin, F ; Aubry, A ; Chassignole, B ; Fouquet, T ; Derode, A</creatorcontrib><description>Ultrasonic non-destructive testing of polycrystalline structures can be disturbed by scattering at grain boundaries. Understanding and modeling this so-called astructural noisea is crucial for characterization as well as detection purposes. Structural noise can be considered as a fingerprint of the material under investigation, since it contains information about its microstructure. The interpretation of experimental data necessitates an accurate comprehension of complex phenomena that occur in multiple scattering media and thus robust scattering models. In particular, numerical models can offer the opportunity to realize parametrical studies on controlled microstructures. However, the ability of the model to simulate wave propagation in complex media must be validated. In that perspective, the main objective of the present work is to evaluate the ability of the finite-element code ATHENA 2D to reproduce typical features of multiple wave scattering in the context of ultrasonic non-destructive evaluation, with an array of sources and receivers. Experiments were carried out with a 64-element array, around 2 MHz. The sample was a mock-up of Inconel600ARG exhibiting a coarse grain structure with a known grain size distribution. The numerical model of this microstructure is based on Voronoi diagrams. Two physical parameters were used to compare numerical and experimental data: the coherent backscattering peak, and the singular value distribution of the array response matrix. Though the simulations are 2-D, a good agreement was found between simulated and experimental data.</description><identifier>ISSN: 0041-624X</identifier><identifier>DOI: 10.1016/j.ultras.2013.06.012</identifier><language>eng</language><subject>Arrays ; Computer simulation ; Fingerprints ; Mathematical models ; Microstructure ; Nondestructive testing ; Scattering ; Ultrasonic testing</subject><ispartof>Ultrasonics, 2014-01, Vol.54 (1), p.358-367</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Shahjahan, S</creatorcontrib><creatorcontrib>Rupin, F</creatorcontrib><creatorcontrib>Aubry, A</creatorcontrib><creatorcontrib>Chassignole, B</creatorcontrib><creatorcontrib>Fouquet, T</creatorcontrib><creatorcontrib>Derode, A</creatorcontrib><title>Comparison between experimental and 2-D numerical studies of multiple scattering in Inconel600ARG by means of array probes</title><title>Ultrasonics</title><description>Ultrasonic non-destructive testing of polycrystalline structures can be disturbed by scattering at grain boundaries. Understanding and modeling this so-called astructural noisea is crucial for characterization as well as detection purposes. Structural noise can be considered as a fingerprint of the material under investigation, since it contains information about its microstructure. The interpretation of experimental data necessitates an accurate comprehension of complex phenomena that occur in multiple scattering media and thus robust scattering models. In particular, numerical models can offer the opportunity to realize parametrical studies on controlled microstructures. However, the ability of the model to simulate wave propagation in complex media must be validated. In that perspective, the main objective of the present work is to evaluate the ability of the finite-element code ATHENA 2D to reproduce typical features of multiple wave scattering in the context of ultrasonic non-destructive evaluation, with an array of sources and receivers. Experiments were carried out with a 64-element array, around 2 MHz. The sample was a mock-up of Inconel600ARG exhibiting a coarse grain structure with a known grain size distribution. The numerical model of this microstructure is based on Voronoi diagrams. Two physical parameters were used to compare numerical and experimental data: the coherent backscattering peak, and the singular value distribution of the array response matrix. Though the simulations are 2-D, a good agreement was found between simulated and experimental data.</description><subject>Arrays</subject><subject>Computer simulation</subject><subject>Fingerprints</subject><subject>Mathematical models</subject><subject>Microstructure</subject><subject>Nondestructive testing</subject><subject>Scattering</subject><subject>Ultrasonic testing</subject><issn>0041-624X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNqVjc1OwzAQhH0AiUL7Bhz2yCVh7aQhV1R-r4gDt8pJt8iVvQ5eR1CeHgvxApxG-r4ZjVKXGmuNurs-1LPPyUptUDc1djVqc6IWiK2uOtO-nalzkQOibnvdLNT3JobJJieRYaD8ScRAXxMlF4iz9WB5B6a6A55DgWMhkuedI4G4h1C-3OQJZLQ5F8_v4BieeYxMvkO8fXmE4QiBLP8ObEr2CFOKA8lSne6tF1r95YW6erh_3TxVRX_MJHkbnIzkvWWKs2z1Wjet6W_WffOP6g8o1Vip</recordid><startdate>20140101</startdate><enddate>20140101</enddate><creator>Shahjahan, S</creator><creator>Rupin, F</creator><creator>Aubry, A</creator><creator>Chassignole, B</creator><creator>Fouquet, T</creator><creator>Derode, A</creator><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20140101</creationdate><title>Comparison between experimental and 2-D numerical studies of multiple scattering in Inconel600ARG by means of array probes</title><author>Shahjahan, S ; Rupin, F ; Aubry, A ; Chassignole, B ; Fouquet, T ; Derode, A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_15134287583</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Arrays</topic><topic>Computer simulation</topic><topic>Fingerprints</topic><topic>Mathematical models</topic><topic>Microstructure</topic><topic>Nondestructive testing</topic><topic>Scattering</topic><topic>Ultrasonic testing</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shahjahan, S</creatorcontrib><creatorcontrib>Rupin, F</creatorcontrib><creatorcontrib>Aubry, A</creatorcontrib><creatorcontrib>Chassignole, B</creatorcontrib><creatorcontrib>Fouquet, T</creatorcontrib><creatorcontrib>Derode, A</creatorcontrib><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Ultrasonics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shahjahan, S</au><au>Rupin, F</au><au>Aubry, A</au><au>Chassignole, B</au><au>Fouquet, T</au><au>Derode, A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison between experimental and 2-D numerical studies of multiple scattering in Inconel600ARG by means of array probes</atitle><jtitle>Ultrasonics</jtitle><date>2014-01-01</date><risdate>2014</risdate><volume>54</volume><issue>1</issue><spage>358</spage><epage>367</epage><pages>358-367</pages><issn>0041-624X</issn><abstract>Ultrasonic non-destructive testing of polycrystalline structures can be disturbed by scattering at grain boundaries. Understanding and modeling this so-called astructural noisea is crucial for characterization as well as detection purposes. Structural noise can be considered as a fingerprint of the material under investigation, since it contains information about its microstructure. The interpretation of experimental data necessitates an accurate comprehension of complex phenomena that occur in multiple scattering media and thus robust scattering models. In particular, numerical models can offer the opportunity to realize parametrical studies on controlled microstructures. However, the ability of the model to simulate wave propagation in complex media must be validated. In that perspective, the main objective of the present work is to evaluate the ability of the finite-element code ATHENA 2D to reproduce typical features of multiple wave scattering in the context of ultrasonic non-destructive evaluation, with an array of sources and receivers. Experiments were carried out with a 64-element array, around 2 MHz. The sample was a mock-up of Inconel600ARG exhibiting a coarse grain structure with a known grain size distribution. The numerical model of this microstructure is based on Voronoi diagrams. Two physical parameters were used to compare numerical and experimental data: the coherent backscattering peak, and the singular value distribution of the array response matrix. Though the simulations are 2-D, a good agreement was found between simulated and experimental data.</abstract><doi>10.1016/j.ultras.2013.06.012</doi></addata></record>
fulltext fulltext
identifier ISSN: 0041-624X
ispartof Ultrasonics, 2014-01, Vol.54 (1), p.358-367
issn 0041-624X
language eng
recordid cdi_proquest_miscellaneous_1513428758
source ScienceDirect Journals (5 years ago - present)
subjects Arrays
Computer simulation
Fingerprints
Mathematical models
Microstructure
Nondestructive testing
Scattering
Ultrasonic testing
title Comparison between experimental and 2-D numerical studies of multiple scattering in Inconel600ARG by means of array probes
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T18%3A19%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20between%20experimental%20and%202-D%20numerical%20studies%20of%20multiple%20scattering%20in%20Inconel600ARG%20by%20means%20of%20array%20probes&rft.jtitle=Ultrasonics&rft.au=Shahjahan,%20S&rft.date=2014-01-01&rft.volume=54&rft.issue=1&rft.spage=358&rft.epage=367&rft.pages=358-367&rft.issn=0041-624X&rft_id=info:doi/10.1016/j.ultras.2013.06.012&rft_dat=%3Cproquest%3E1513428758%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1513428758&rft_id=info:pmid/&rfr_iscdi=true