Development and Testing of a Low NOx Hydrogen Combustion System for Heavy-Duty Gas Turbines

Interest in hydrogen as a primary fuel stream in heavy-duty gas turbine engines has increased as precombustion carbon capture and sequestration (CCS) has become a viable option for integrated gasification combined cycle (IGCC) power plants. The U.S. Department of Energy has funded the Advanced IGCC/...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of engineering for gas turbines and power 2013-02, Vol.135 (2), p.1-8
Hauptverfasser: York, William D, Ziminsky, Willy S, Yilmaz, Ertan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 8
container_issue 2
container_start_page 1
container_title Journal of engineering for gas turbines and power
container_volume 135
creator York, William D
Ziminsky, Willy S
Yilmaz, Ertan
description Interest in hydrogen as a primary fuel stream in heavy-duty gas turbine engines has increased as precombustion carbon capture and sequestration (CCS) has become a viable option for integrated gasification combined cycle (IGCC) power plants. The U.S. Department of Energy has funded the Advanced IGCC/Hydrogen Gas Turbine Program since 2005 with an aggressive plant-level NOx target of 2 ppm at 15% O2 for an advanced gas turbine cycle. Approaching this NOx level with highly reactive hydrogen fuel at the conditions required is a formidable challenge that requires novel combustion technology. This study begins by measuring entitlement NOx emissions from perfectly premixed combustion of the high-hydrogen fuels of interest. A new premixing fuel injector for high-hydrogen fuels was designed to balance reliable flashback-free operation, reasonable pressure drop, and low emissions. The concept relies on small-scale jet-in-crossflow mixing that is a departure from traditional swirl-based premixing concepts. Single nozzle rig experiments were conducted at pressures of 10 atm and 17 atm, with air preheat temperatures of about 650 K. With nitrogen-diluted hydrogen fuel, characteristic of carbon-free syngas, stable operation without flashback was conducted up to flame temperatures of approximately 1850 K. In addition to the effects of pressure, the impacts of nitrogen dilution levels and amounts of minor constituents in the fuel—carbon monoxide, carbon dioxide, and methane—on flame holding in the premixer are presented. The new fuel injector concept has been incorporated into a full-scale, multinozzle combustor can with an energy conversion rate of more than 10 MW at F-class conditions. The full-can testing was conducted at full gas turbine conditions and various fuel compositions of hydrogen, natural gas, and nitrogen. This combustion system has accumulated over 100 h of fired testing at full load with hydrogen comprising over 90% of the reactants by volume. NOx emissions (ppm) have been measured in the single digits with hydrogen-nitrogen fuel at target gas turbine pressure and temperatures. Results of the testing show that small-scale fuel-air mixing can deliver a reliable, low-NOx solution to hydrogen combustion in advanced gas turbines.
doi_str_mv 10.1115/1.4007733
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1512326401</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1512326401</sourcerecordid><originalsourceid>FETCH-LOGICAL-a378t-e8cf03e9d34035a3e69099bc7e8e1bd0e4389e4c58d6e6813572368008c5480d3</originalsourceid><addsrcrecordid>eNo9kLFOwzAURS0EEqUwMLN4QYIhYMd2bI-ohRapogNlYrDc5KVKldjFTgr5e4JaMb3lvKN7L0LXlDxQSsUjfeCESMnYCRpRkapEaapP0YhIniZcanGOLmLcEkIZ43KEPqewh9rvGnAttq7AK4ht5TbYl9jihf_Gb8sfPO-L4Dfg8MQ3624AvMPvfWyhwaUPeA523yfTru3xzEa86sK6chAv0Vlp6whXxztGHy_Pq8k8WSxnr5OnRWKZVG0CKi8JA10wTpiwDDJNtF7nEhTQdUGAM6WB50IVGWSKMiFTlilCVC64IgUbo7uDdxf8VzfkN00Vc6hr68B30VBBU5ZmfOg8RvcHNA8-xgCl2YWqsaE3lJi_AQ01xwEH9vaotTG3dRmsy6v4_5BKKoVIs4G7OXA2NmC2vgtuaGvY4JCa_QIxj3bb</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1512326401</pqid></control><display><type>article</type><title>Development and Testing of a Low NOx Hydrogen Combustion System for Heavy-Duty Gas Turbines</title><source>Alma/SFX Local Collection</source><source>ASME Transactions Journals (Current)</source><creator>York, William D ; Ziminsky, Willy S ; Yilmaz, Ertan</creator><creatorcontrib>York, William D ; Ziminsky, Willy S ; Yilmaz, Ertan</creatorcontrib><description>Interest in hydrogen as a primary fuel stream in heavy-duty gas turbine engines has increased as precombustion carbon capture and sequestration (CCS) has become a viable option for integrated gasification combined cycle (IGCC) power plants. The U.S. Department of Energy has funded the Advanced IGCC/Hydrogen Gas Turbine Program since 2005 with an aggressive plant-level NOx target of 2 ppm at 15% O2 for an advanced gas turbine cycle. Approaching this NOx level with highly reactive hydrogen fuel at the conditions required is a formidable challenge that requires novel combustion technology. This study begins by measuring entitlement NOx emissions from perfectly premixed combustion of the high-hydrogen fuels of interest. A new premixing fuel injector for high-hydrogen fuels was designed to balance reliable flashback-free operation, reasonable pressure drop, and low emissions. The concept relies on small-scale jet-in-crossflow mixing that is a departure from traditional swirl-based premixing concepts. Single nozzle rig experiments were conducted at pressures of 10 atm and 17 atm, with air preheat temperatures of about 650 K. With nitrogen-diluted hydrogen fuel, characteristic of carbon-free syngas, stable operation without flashback was conducted up to flame temperatures of approximately 1850 K. In addition to the effects of pressure, the impacts of nitrogen dilution levels and amounts of minor constituents in the fuel—carbon monoxide, carbon dioxide, and methane—on flame holding in the premixer are presented. The new fuel injector concept has been incorporated into a full-scale, multinozzle combustor can with an energy conversion rate of more than 10 MW at F-class conditions. The full-can testing was conducted at full gas turbine conditions and various fuel compositions of hydrogen, natural gas, and nitrogen. This combustion system has accumulated over 100 h of fired testing at full load with hydrogen comprising over 90% of the reactants by volume. NOx emissions (ppm) have been measured in the single digits with hydrogen-nitrogen fuel at target gas turbine pressure and temperatures. Results of the testing show that small-scale fuel-air mixing can deliver a reliable, low-NOx solution to hydrogen combustion in advanced gas turbines.</description><identifier>ISSN: 0742-4795</identifier><identifier>EISSN: 1528-8919</identifier><identifier>DOI: 10.1115/1.4007733</identifier><identifier>CODEN: JETPEZ</identifier><language>eng</language><publisher>New York, N: ASME</publisher><subject>Applied sciences ; Energy ; Energy. Thermal use of fuels ; Engines and turbines ; Equipments for energy generation and conversion: thermal, electrical, mechanical energy, etc ; Exact sciences and technology ; Gas Turbines: Industrial &amp; Cogeneration</subject><ispartof>Journal of engineering for gas turbines and power, 2013-02, Vol.135 (2), p.1-8</ispartof><rights>2014 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a378t-e8cf03e9d34035a3e69099bc7e8e1bd0e4389e4c58d6e6813572368008c5480d3</citedby><cites>FETCH-LOGICAL-a378t-e8cf03e9d34035a3e69099bc7e8e1bd0e4389e4c58d6e6813572368008c5480d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902,38497</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=27175526$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>York, William D</creatorcontrib><creatorcontrib>Ziminsky, Willy S</creatorcontrib><creatorcontrib>Yilmaz, Ertan</creatorcontrib><title>Development and Testing of a Low NOx Hydrogen Combustion System for Heavy-Duty Gas Turbines</title><title>Journal of engineering for gas turbines and power</title><addtitle>J. Eng. Gas Turbines Power</addtitle><description>Interest in hydrogen as a primary fuel stream in heavy-duty gas turbine engines has increased as precombustion carbon capture and sequestration (CCS) has become a viable option for integrated gasification combined cycle (IGCC) power plants. The U.S. Department of Energy has funded the Advanced IGCC/Hydrogen Gas Turbine Program since 2005 with an aggressive plant-level NOx target of 2 ppm at 15% O2 for an advanced gas turbine cycle. Approaching this NOx level with highly reactive hydrogen fuel at the conditions required is a formidable challenge that requires novel combustion technology. This study begins by measuring entitlement NOx emissions from perfectly premixed combustion of the high-hydrogen fuels of interest. A new premixing fuel injector for high-hydrogen fuels was designed to balance reliable flashback-free operation, reasonable pressure drop, and low emissions. The concept relies on small-scale jet-in-crossflow mixing that is a departure from traditional swirl-based premixing concepts. Single nozzle rig experiments were conducted at pressures of 10 atm and 17 atm, with air preheat temperatures of about 650 K. With nitrogen-diluted hydrogen fuel, characteristic of carbon-free syngas, stable operation without flashback was conducted up to flame temperatures of approximately 1850 K. In addition to the effects of pressure, the impacts of nitrogen dilution levels and amounts of minor constituents in the fuel—carbon monoxide, carbon dioxide, and methane—on flame holding in the premixer are presented. The new fuel injector concept has been incorporated into a full-scale, multinozzle combustor can with an energy conversion rate of more than 10 MW at F-class conditions. The full-can testing was conducted at full gas turbine conditions and various fuel compositions of hydrogen, natural gas, and nitrogen. This combustion system has accumulated over 100 h of fired testing at full load with hydrogen comprising over 90% of the reactants by volume. NOx emissions (ppm) have been measured in the single digits with hydrogen-nitrogen fuel at target gas turbine pressure and temperatures. Results of the testing show that small-scale fuel-air mixing can deliver a reliable, low-NOx solution to hydrogen combustion in advanced gas turbines.</description><subject>Applied sciences</subject><subject>Energy</subject><subject>Energy. Thermal use of fuels</subject><subject>Engines and turbines</subject><subject>Equipments for energy generation and conversion: thermal, electrical, mechanical energy, etc</subject><subject>Exact sciences and technology</subject><subject>Gas Turbines: Industrial &amp; Cogeneration</subject><issn>0742-4795</issn><issn>1528-8919</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNo9kLFOwzAURS0EEqUwMLN4QYIhYMd2bI-ohRapogNlYrDc5KVKldjFTgr5e4JaMb3lvKN7L0LXlDxQSsUjfeCESMnYCRpRkapEaapP0YhIniZcanGOLmLcEkIZ43KEPqewh9rvGnAttq7AK4ht5TbYl9jihf_Gb8sfPO-L4Dfg8MQ3624AvMPvfWyhwaUPeA523yfTru3xzEa86sK6chAv0Vlp6whXxztGHy_Pq8k8WSxnr5OnRWKZVG0CKi8JA10wTpiwDDJNtF7nEhTQdUGAM6WB50IVGWSKMiFTlilCVC64IgUbo7uDdxf8VzfkN00Vc6hr68B30VBBU5ZmfOg8RvcHNA8-xgCl2YWqsaE3lJi_AQ01xwEH9vaotTG3dRmsy6v4_5BKKoVIs4G7OXA2NmC2vgtuaGvY4JCa_QIxj3bb</recordid><startdate>20130201</startdate><enddate>20130201</enddate><creator>York, William D</creator><creator>Ziminsky, Willy S</creator><creator>Yilmaz, Ertan</creator><general>ASME</general><general>American Society of Mechanical Engineers</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>7U6</scope><scope>C1K</scope></search><sort><creationdate>20130201</creationdate><title>Development and Testing of a Low NOx Hydrogen Combustion System for Heavy-Duty Gas Turbines</title><author>York, William D ; Ziminsky, Willy S ; Yilmaz, Ertan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a378t-e8cf03e9d34035a3e69099bc7e8e1bd0e4389e4c58d6e6813572368008c5480d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Applied sciences</topic><topic>Energy</topic><topic>Energy. Thermal use of fuels</topic><topic>Engines and turbines</topic><topic>Equipments for energy generation and conversion: thermal, electrical, mechanical energy, etc</topic><topic>Exact sciences and technology</topic><topic>Gas Turbines: Industrial &amp; Cogeneration</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>York, William D</creatorcontrib><creatorcontrib>Ziminsky, Willy S</creatorcontrib><creatorcontrib>Yilmaz, Ertan</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Sustainability Science Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><jtitle>Journal of engineering for gas turbines and power</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>York, William D</au><au>Ziminsky, Willy S</au><au>Yilmaz, Ertan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development and Testing of a Low NOx Hydrogen Combustion System for Heavy-Duty Gas Turbines</atitle><jtitle>Journal of engineering for gas turbines and power</jtitle><stitle>J. Eng. Gas Turbines Power</stitle><date>2013-02-01</date><risdate>2013</risdate><volume>135</volume><issue>2</issue><spage>1</spage><epage>8</epage><pages>1-8</pages><issn>0742-4795</issn><eissn>1528-8919</eissn><coden>JETPEZ</coden><abstract>Interest in hydrogen as a primary fuel stream in heavy-duty gas turbine engines has increased as precombustion carbon capture and sequestration (CCS) has become a viable option for integrated gasification combined cycle (IGCC) power plants. The U.S. Department of Energy has funded the Advanced IGCC/Hydrogen Gas Turbine Program since 2005 with an aggressive plant-level NOx target of 2 ppm at 15% O2 for an advanced gas turbine cycle. Approaching this NOx level with highly reactive hydrogen fuel at the conditions required is a formidable challenge that requires novel combustion technology. This study begins by measuring entitlement NOx emissions from perfectly premixed combustion of the high-hydrogen fuels of interest. A new premixing fuel injector for high-hydrogen fuels was designed to balance reliable flashback-free operation, reasonable pressure drop, and low emissions. The concept relies on small-scale jet-in-crossflow mixing that is a departure from traditional swirl-based premixing concepts. Single nozzle rig experiments were conducted at pressures of 10 atm and 17 atm, with air preheat temperatures of about 650 K. With nitrogen-diluted hydrogen fuel, characteristic of carbon-free syngas, stable operation without flashback was conducted up to flame temperatures of approximately 1850 K. In addition to the effects of pressure, the impacts of nitrogen dilution levels and amounts of minor constituents in the fuel—carbon monoxide, carbon dioxide, and methane—on flame holding in the premixer are presented. The new fuel injector concept has been incorporated into a full-scale, multinozzle combustor can with an energy conversion rate of more than 10 MW at F-class conditions. The full-can testing was conducted at full gas turbine conditions and various fuel compositions of hydrogen, natural gas, and nitrogen. This combustion system has accumulated over 100 h of fired testing at full load with hydrogen comprising over 90% of the reactants by volume. NOx emissions (ppm) have been measured in the single digits with hydrogen-nitrogen fuel at target gas turbine pressure and temperatures. Results of the testing show that small-scale fuel-air mixing can deliver a reliable, low-NOx solution to hydrogen combustion in advanced gas turbines.</abstract><cop>New York, N</cop><pub>ASME</pub><doi>10.1115/1.4007733</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0742-4795
ispartof Journal of engineering for gas turbines and power, 2013-02, Vol.135 (2), p.1-8
issn 0742-4795
1528-8919
language eng
recordid cdi_proquest_miscellaneous_1512326401
source Alma/SFX Local Collection; ASME Transactions Journals (Current)
subjects Applied sciences
Energy
Energy. Thermal use of fuels
Engines and turbines
Equipments for energy generation and conversion: thermal, electrical, mechanical energy, etc
Exact sciences and technology
Gas Turbines: Industrial & Cogeneration
title Development and Testing of a Low NOx Hydrogen Combustion System for Heavy-Duty Gas Turbines
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T02%3A17%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20and%20Testing%20of%20a%20Low%20NOx%20Hydrogen%20Combustion%20System%20for%20Heavy-Duty%20Gas%20Turbines&rft.jtitle=Journal%20of%20engineering%20for%20gas%20turbines%20and%20power&rft.au=York,%20William%20D&rft.date=2013-02-01&rft.volume=135&rft.issue=2&rft.spage=1&rft.epage=8&rft.pages=1-8&rft.issn=0742-4795&rft.eissn=1528-8919&rft.coden=JETPEZ&rft_id=info:doi/10.1115/1.4007733&rft_dat=%3Cproquest_cross%3E1512326401%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1512326401&rft_id=info:pmid/&rfr_iscdi=true