Operation of an optically coherent frequency comb outside the metrology lab

We demonstrate a self-referenced fiber frequency comb that can operate outside the well-controlled optical laboratory. The frequency comb has residual optical linewidths of < 1 Hz, sub-radian residual optical phase noise, and residual pulse-to-pulse timing jitter of 2.4 - 5 fs, when locked to an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Optics express 2014-03, Vol.22 (6), p.6996-7006
Hauptverfasser: Sinclair, L C, Coddington, I, Swann, W C, Rieker, G B, Hati, A, Iwakuni, K, Newbury, N R
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 7006
container_issue 6
container_start_page 6996
container_title Optics express
container_volume 22
creator Sinclair, L C
Coddington, I
Swann, W C
Rieker, G B
Hati, A
Iwakuni, K
Newbury, N R
description We demonstrate a self-referenced fiber frequency comb that can operate outside the well-controlled optical laboratory. The frequency comb has residual optical linewidths of < 1 Hz, sub-radian residual optical phase noise, and residual pulse-to-pulse timing jitter of 2.4 - 5 fs, when locked to an optical reference. This fully phase-locked frequency comb has been successfully operated in a moving vehicle with 0.5 g peak accelerations and on a shaker table with a sustained 0.5 g rms integrated acceleration, while retaining its optical coherence and 5-fs-level timing jitter. This frequency comb should enable metrological measurements outside the laboratory with the precision and accuracy that are the hallmarks of comb-based systems.
doi_str_mv 10.1364/OE.22.006996
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1510401705</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1510401705</sourcerecordid><originalsourceid>FETCH-LOGICAL-c438t-a4b2d5160831376d5d19fb404fc878471dd8c9faa43b357257af287c3429afc23</originalsourceid><addsrcrecordid>eNpNkDtPwzAURi0EoqWwMSOPDKT4FdsZUVUeolIWmC3HsWlQEgfbGfrvm6oFsdx7dXX06dMB4BajJaacPZbrJSFLhHhR8DMwx6hgGUNSnP-7Z-Aqxm-EMBOFuAQzwjhniMk5eC8HG3RqfA-9g3qaQ2qMbtsdNH5rg-0TdMH-jLY3h1dXQT-m2NQWpq2FnU3Bt_5rB1tdXYMLp9tob057AT6f1x-r12xTvrytnjaZYVSmTLOK1DnmSFJMBa_zGheumuo4I4VkAte1NIXTmtGK5oLkQjsihaGMFNoZQhfg_pg7BD8Vi0l1TTS2bXVv_RgVzjFiCAuUT-jDETXBxxisU0NoOh12CiN10KfKtSJEHfVN-N0peaw6W__Bv77oHkZ4ahw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1510401705</pqid></control><display><type>article</type><title>Operation of an optically coherent frequency comb outside the metrology lab</title><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Sinclair, L C ; Coddington, I ; Swann, W C ; Rieker, G B ; Hati, A ; Iwakuni, K ; Newbury, N R</creator><creatorcontrib>Sinclair, L C ; Coddington, I ; Swann, W C ; Rieker, G B ; Hati, A ; Iwakuni, K ; Newbury, N R</creatorcontrib><description>We demonstrate a self-referenced fiber frequency comb that can operate outside the well-controlled optical laboratory. The frequency comb has residual optical linewidths of &lt; 1 Hz, sub-radian residual optical phase noise, and residual pulse-to-pulse timing jitter of 2.4 - 5 fs, when locked to an optical reference. This fully phase-locked frequency comb has been successfully operated in a moving vehicle with 0.5 g peak accelerations and on a shaker table with a sustained 0.5 g rms integrated acceleration, while retaining its optical coherence and 5-fs-level timing jitter. This frequency comb should enable metrological measurements outside the laboratory with the precision and accuracy that are the hallmarks of comb-based systems.</description><identifier>ISSN: 1094-4087</identifier><identifier>EISSN: 1094-4087</identifier><identifier>DOI: 10.1364/OE.22.006996</identifier><identifier>PMID: 24664048</identifier><language>eng</language><publisher>United States</publisher><ispartof>Optics express, 2014-03, Vol.22 (6), p.6996-7006</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c438t-a4b2d5160831376d5d19fb404fc878471dd8c9faa43b357257af287c3429afc23</citedby><cites>FETCH-LOGICAL-c438t-a4b2d5160831376d5d19fb404fc878471dd8c9faa43b357257af287c3429afc23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,860,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24664048$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sinclair, L C</creatorcontrib><creatorcontrib>Coddington, I</creatorcontrib><creatorcontrib>Swann, W C</creatorcontrib><creatorcontrib>Rieker, G B</creatorcontrib><creatorcontrib>Hati, A</creatorcontrib><creatorcontrib>Iwakuni, K</creatorcontrib><creatorcontrib>Newbury, N R</creatorcontrib><title>Operation of an optically coherent frequency comb outside the metrology lab</title><title>Optics express</title><addtitle>Opt Express</addtitle><description>We demonstrate a self-referenced fiber frequency comb that can operate outside the well-controlled optical laboratory. The frequency comb has residual optical linewidths of &lt; 1 Hz, sub-radian residual optical phase noise, and residual pulse-to-pulse timing jitter of 2.4 - 5 fs, when locked to an optical reference. This fully phase-locked frequency comb has been successfully operated in a moving vehicle with 0.5 g peak accelerations and on a shaker table with a sustained 0.5 g rms integrated acceleration, while retaining its optical coherence and 5-fs-level timing jitter. This frequency comb should enable metrological measurements outside the laboratory with the precision and accuracy that are the hallmarks of comb-based systems.</description><issn>1094-4087</issn><issn>1094-4087</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNpNkDtPwzAURi0EoqWwMSOPDKT4FdsZUVUeolIWmC3HsWlQEgfbGfrvm6oFsdx7dXX06dMB4BajJaacPZbrJSFLhHhR8DMwx6hgGUNSnP-7Z-Aqxm-EMBOFuAQzwjhniMk5eC8HG3RqfA-9g3qaQ2qMbtsdNH5rg-0TdMH-jLY3h1dXQT-m2NQWpq2FnU3Bt_5rB1tdXYMLp9tob057AT6f1x-r12xTvrytnjaZYVSmTLOK1DnmSFJMBa_zGheumuo4I4VkAte1NIXTmtGK5oLkQjsihaGMFNoZQhfg_pg7BD8Vi0l1TTS2bXVv_RgVzjFiCAuUT-jDETXBxxisU0NoOh12CiN10KfKtSJEHfVN-N0peaw6W__Bv77oHkZ4ahw</recordid><startdate>20140324</startdate><enddate>20140324</enddate><creator>Sinclair, L C</creator><creator>Coddington, I</creator><creator>Swann, W C</creator><creator>Rieker, G B</creator><creator>Hati, A</creator><creator>Iwakuni, K</creator><creator>Newbury, N R</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20140324</creationdate><title>Operation of an optically coherent frequency comb outside the metrology lab</title><author>Sinclair, L C ; Coddington, I ; Swann, W C ; Rieker, G B ; Hati, A ; Iwakuni, K ; Newbury, N R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c438t-a4b2d5160831376d5d19fb404fc878471dd8c9faa43b357257af287c3429afc23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sinclair, L C</creatorcontrib><creatorcontrib>Coddington, I</creatorcontrib><creatorcontrib>Swann, W C</creatorcontrib><creatorcontrib>Rieker, G B</creatorcontrib><creatorcontrib>Hati, A</creatorcontrib><creatorcontrib>Iwakuni, K</creatorcontrib><creatorcontrib>Newbury, N R</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sinclair, L C</au><au>Coddington, I</au><au>Swann, W C</au><au>Rieker, G B</au><au>Hati, A</au><au>Iwakuni, K</au><au>Newbury, N R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Operation of an optically coherent frequency comb outside the metrology lab</atitle><jtitle>Optics express</jtitle><addtitle>Opt Express</addtitle><date>2014-03-24</date><risdate>2014</risdate><volume>22</volume><issue>6</issue><spage>6996</spage><epage>7006</epage><pages>6996-7006</pages><issn>1094-4087</issn><eissn>1094-4087</eissn><abstract>We demonstrate a self-referenced fiber frequency comb that can operate outside the well-controlled optical laboratory. The frequency comb has residual optical linewidths of &lt; 1 Hz, sub-radian residual optical phase noise, and residual pulse-to-pulse timing jitter of 2.4 - 5 fs, when locked to an optical reference. This fully phase-locked frequency comb has been successfully operated in a moving vehicle with 0.5 g peak accelerations and on a shaker table with a sustained 0.5 g rms integrated acceleration, while retaining its optical coherence and 5-fs-level timing jitter. This frequency comb should enable metrological measurements outside the laboratory with the precision and accuracy that are the hallmarks of comb-based systems.</abstract><cop>United States</cop><pmid>24664048</pmid><doi>10.1364/OE.22.006996</doi><tpages>11</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1094-4087
ispartof Optics express, 2014-03, Vol.22 (6), p.6996-7006
issn 1094-4087
1094-4087
language eng
recordid cdi_proquest_miscellaneous_1510401705
source DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection
title Operation of an optically coherent frequency comb outside the metrology lab
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T02%3A12%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Operation%20of%20an%20optically%20coherent%20frequency%20comb%20outside%20the%20metrology%20lab&rft.jtitle=Optics%20express&rft.au=Sinclair,%20L%20C&rft.date=2014-03-24&rft.volume=22&rft.issue=6&rft.spage=6996&rft.epage=7006&rft.pages=6996-7006&rft.issn=1094-4087&rft.eissn=1094-4087&rft_id=info:doi/10.1364/OE.22.006996&rft_dat=%3Cproquest_cross%3E1510401705%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1510401705&rft_id=info:pmid/24664048&rfr_iscdi=true