Does bilirubin interfere with capillary electrophoresis of serum proteins?
Capillary electrophoresis of serum proteins is a fast, reliable and simple technique, but many interference exist. The objective of our work is to study the interference of bilirubin on this technique; 70 icteric sera were analysed on Capillarys ™ (Sebia). A second electrophoresis was performed on 4...
Gespeichert in:
Veröffentlicht in: | Annales de biologie clinique (Paris) 2014-01, Vol.72 (1), p.124-128 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | fre |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 128 |
---|---|
container_issue | 1 |
container_start_page | 124 |
container_title | Annales de biologie clinique (Paris) |
container_volume | 72 |
creator | Hellara, Ilhem Fekih, Ons Triki, Sonia Elmay, Ahlem Neffati, Fadoua Najjar, Mohamed Fadhel |
description | Capillary electrophoresis of serum proteins is a fast, reliable and simple technique, but many interference exist. The objective of our work is to study the interference of bilirubin on this technique; 70 icteric sera were analysed on Capillarys ™ (Sebia). A second electrophoresis was performed on 40 samples after bilirubin photodegradation. The bilirubin and serum proteins were determinated respectively by Jendrassik and Grof and biuret methods on Konélab 20i ™ (Thermo Electron Corporation). We found abnormal spreading of the albumin fraction of the anode side wich constitute sometimes an isolated fraction in the traditional area of pre-albumin migration. This fraction varies from 2.0 ± 2.0% (0.0 to 7.3%) or 0.98 ± 1.53 g/L (0 to 5.3 g/L) and it seems to be related to the direct bilirubin since, following overloading sera with a solution of bilirubin, no further fraction was recovered. An average decrease of bilirubin after photodegradation of 58 ± 17% (26-89%) is followed by a decrease in the same order 64 ± 38% (10-100%) of the additional fraction. Acetate cellulose electrophoresis of the same samples showed no variation. The high bilirubin levels seem modify slightly the electrophoretic profile. However the impact of the interference on the interpretation of electrophoretic trace is negligible. |
doi_str_mv | 10.1684/abc.2013.0926 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_1508944414</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1508944414</sourcerecordid><originalsourceid>FETCH-LOGICAL-c185t-7b3f95e5b678a5c85fcb9af69c4a05ac8c4e5959bf56631a0b270b4e0674ad323</originalsourceid><addsrcrecordid>eNo1j0tLAzEYRYMgtlaXbiVLN1PznmQlUuuLghtdD0n6hUbmZZJB_PcOWFd3c7j3HoSuKFlTpcWtdX7NCOVrYpg6QUtqJKkUpWyBznP-JIQyzfkZWjAhDKOELtHrwwAZu9jGNLnY49gXSAES4O9YDtjbMbatTT8YWvAlDeNhSJBjxkPAGdLU4TENBWKf7y7QabBthstjrtDH4_Z981zt3p5eNve7ylMtS1U7HowE6VStrfRaBu-MDcp4YYm0XnsB0kjjglSKU0scq4kTQFQt7J4zvkI3f73z8tcEuTRdzB7mmz0MU26oJNoIIaiY0esjOrkO9s2YYjfLNP_-_Bd_T1tZ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1508944414</pqid></control><display><type>article</type><title>Does bilirubin interfere with capillary electrophoresis of serum proteins?</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Hellara, Ilhem ; Fekih, Ons ; Triki, Sonia ; Elmay, Ahlem ; Neffati, Fadoua ; Najjar, Mohamed Fadhel</creator><creatorcontrib>Hellara, Ilhem ; Fekih, Ons ; Triki, Sonia ; Elmay, Ahlem ; Neffati, Fadoua ; Najjar, Mohamed Fadhel</creatorcontrib><description>Capillary electrophoresis of serum proteins is a fast, reliable and simple technique, but many interference exist. The objective of our work is to study the interference of bilirubin on this technique; 70 icteric sera were analysed on Capillarys ™ (Sebia). A second electrophoresis was performed on 40 samples after bilirubin photodegradation. The bilirubin and serum proteins were determinated respectively by Jendrassik and Grof and biuret methods on Konélab 20i ™ (Thermo Electron Corporation). We found abnormal spreading of the albumin fraction of the anode side wich constitute sometimes an isolated fraction in the traditional area of pre-albumin migration. This fraction varies from 2.0 ± 2.0% (0.0 to 7.3%) or 0.98 ± 1.53 g/L (0 to 5.3 g/L) and it seems to be related to the direct bilirubin since, following overloading sera with a solution of bilirubin, no further fraction was recovered. An average decrease of bilirubin after photodegradation of 58 ± 17% (26-89%) is followed by a decrease in the same order 64 ± 38% (10-100%) of the additional fraction. Acetate cellulose electrophoresis of the same samples showed no variation. The high bilirubin levels seem modify slightly the electrophoretic profile. However the impact of the interference on the interpretation of electrophoretic trace is negligible.</description><identifier>EISSN: 1950-6112</identifier><identifier>DOI: 10.1684/abc.2013.0926</identifier><identifier>PMID: 24492101</identifier><language>fre</language><publisher>France</publisher><subject>Albumins - analysis ; Bilirubin - blood ; Blood Chemical Analysis - methods ; Blood Proteins - analysis ; Chemical Fractionation ; Electrophoresis, Capillary ; Humans</subject><ispartof>Annales de biologie clinique (Paris), 2014-01, Vol.72 (1), p.124-128</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c185t-7b3f95e5b678a5c85fcb9af69c4a05ac8c4e5959bf56631a0b270b4e0674ad323</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24492101$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hellara, Ilhem</creatorcontrib><creatorcontrib>Fekih, Ons</creatorcontrib><creatorcontrib>Triki, Sonia</creatorcontrib><creatorcontrib>Elmay, Ahlem</creatorcontrib><creatorcontrib>Neffati, Fadoua</creatorcontrib><creatorcontrib>Najjar, Mohamed Fadhel</creatorcontrib><title>Does bilirubin interfere with capillary electrophoresis of serum proteins?</title><title>Annales de biologie clinique (Paris)</title><addtitle>Ann Biol Clin (Paris)</addtitle><description>Capillary electrophoresis of serum proteins is a fast, reliable and simple technique, but many interference exist. The objective of our work is to study the interference of bilirubin on this technique; 70 icteric sera were analysed on Capillarys ™ (Sebia). A second electrophoresis was performed on 40 samples after bilirubin photodegradation. The bilirubin and serum proteins were determinated respectively by Jendrassik and Grof and biuret methods on Konélab 20i ™ (Thermo Electron Corporation). We found abnormal spreading of the albumin fraction of the anode side wich constitute sometimes an isolated fraction in the traditional area of pre-albumin migration. This fraction varies from 2.0 ± 2.0% (0.0 to 7.3%) or 0.98 ± 1.53 g/L (0 to 5.3 g/L) and it seems to be related to the direct bilirubin since, following overloading sera with a solution of bilirubin, no further fraction was recovered. An average decrease of bilirubin after photodegradation of 58 ± 17% (26-89%) is followed by a decrease in the same order 64 ± 38% (10-100%) of the additional fraction. Acetate cellulose electrophoresis of the same samples showed no variation. The high bilirubin levels seem modify slightly the electrophoretic profile. However the impact of the interference on the interpretation of electrophoretic trace is negligible.</description><subject>Albumins - analysis</subject><subject>Bilirubin - blood</subject><subject>Blood Chemical Analysis - methods</subject><subject>Blood Proteins - analysis</subject><subject>Chemical Fractionation</subject><subject>Electrophoresis, Capillary</subject><subject>Humans</subject><issn>1950-6112</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo1j0tLAzEYRYMgtlaXbiVLN1PznmQlUuuLghtdD0n6hUbmZZJB_PcOWFd3c7j3HoSuKFlTpcWtdX7NCOVrYpg6QUtqJKkUpWyBznP-JIQyzfkZWjAhDKOELtHrwwAZu9jGNLnY49gXSAES4O9YDtjbMbatTT8YWvAlDeNhSJBjxkPAGdLU4TENBWKf7y7QabBthstjrtDH4_Z981zt3p5eNve7ylMtS1U7HowE6VStrfRaBu-MDcp4YYm0XnsB0kjjglSKU0scq4kTQFQt7J4zvkI3f73z8tcEuTRdzB7mmz0MU26oJNoIIaiY0esjOrkO9s2YYjfLNP_-_Bd_T1tZ</recordid><startdate>201401</startdate><enddate>201401</enddate><creator>Hellara, Ilhem</creator><creator>Fekih, Ons</creator><creator>Triki, Sonia</creator><creator>Elmay, Ahlem</creator><creator>Neffati, Fadoua</creator><creator>Najjar, Mohamed Fadhel</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>201401</creationdate><title>Does bilirubin interfere with capillary electrophoresis of serum proteins?</title><author>Hellara, Ilhem ; Fekih, Ons ; Triki, Sonia ; Elmay, Ahlem ; Neffati, Fadoua ; Najjar, Mohamed Fadhel</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c185t-7b3f95e5b678a5c85fcb9af69c4a05ac8c4e5959bf56631a0b270b4e0674ad323</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>fre</language><creationdate>2014</creationdate><topic>Albumins - analysis</topic><topic>Bilirubin - blood</topic><topic>Blood Chemical Analysis - methods</topic><topic>Blood Proteins - analysis</topic><topic>Chemical Fractionation</topic><topic>Electrophoresis, Capillary</topic><topic>Humans</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hellara, Ilhem</creatorcontrib><creatorcontrib>Fekih, Ons</creatorcontrib><creatorcontrib>Triki, Sonia</creatorcontrib><creatorcontrib>Elmay, Ahlem</creatorcontrib><creatorcontrib>Neffati, Fadoua</creatorcontrib><creatorcontrib>Najjar, Mohamed Fadhel</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Annales de biologie clinique (Paris)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hellara, Ilhem</au><au>Fekih, Ons</au><au>Triki, Sonia</au><au>Elmay, Ahlem</au><au>Neffati, Fadoua</au><au>Najjar, Mohamed Fadhel</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Does bilirubin interfere with capillary electrophoresis of serum proteins?</atitle><jtitle>Annales de biologie clinique (Paris)</jtitle><addtitle>Ann Biol Clin (Paris)</addtitle><date>2014-01</date><risdate>2014</risdate><volume>72</volume><issue>1</issue><spage>124</spage><epage>128</epage><pages>124-128</pages><eissn>1950-6112</eissn><abstract>Capillary electrophoresis of serum proteins is a fast, reliable and simple technique, but many interference exist. The objective of our work is to study the interference of bilirubin on this technique; 70 icteric sera were analysed on Capillarys ™ (Sebia). A second electrophoresis was performed on 40 samples after bilirubin photodegradation. The bilirubin and serum proteins were determinated respectively by Jendrassik and Grof and biuret methods on Konélab 20i ™ (Thermo Electron Corporation). We found abnormal spreading of the albumin fraction of the anode side wich constitute sometimes an isolated fraction in the traditional area of pre-albumin migration. This fraction varies from 2.0 ± 2.0% (0.0 to 7.3%) or 0.98 ± 1.53 g/L (0 to 5.3 g/L) and it seems to be related to the direct bilirubin since, following overloading sera with a solution of bilirubin, no further fraction was recovered. An average decrease of bilirubin after photodegradation of 58 ± 17% (26-89%) is followed by a decrease in the same order 64 ± 38% (10-100%) of the additional fraction. Acetate cellulose electrophoresis of the same samples showed no variation. The high bilirubin levels seem modify slightly the electrophoretic profile. However the impact of the interference on the interpretation of electrophoretic trace is negligible.</abstract><cop>France</cop><pmid>24492101</pmid><doi>10.1684/abc.2013.0926</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | EISSN: 1950-6112 |
ispartof | Annales de biologie clinique (Paris), 2014-01, Vol.72 (1), p.124-128 |
issn | 1950-6112 |
language | fre |
recordid | cdi_proquest_miscellaneous_1508944414 |
source | MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals |
subjects | Albumins - analysis Bilirubin - blood Blood Chemical Analysis - methods Blood Proteins - analysis Chemical Fractionation Electrophoresis, Capillary Humans |
title | Does bilirubin interfere with capillary electrophoresis of serum proteins? |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T03%3A48%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Does%20bilirubin%20interfere%20with%20capillary%20electrophoresis%20of%20serum%20proteins?&rft.jtitle=Annales%20de%20biologie%20clinique%20(Paris)&rft.au=Hellara,%20Ilhem&rft.date=2014-01&rft.volume=72&rft.issue=1&rft.spage=124&rft.epage=128&rft.pages=124-128&rft.eissn=1950-6112&rft_id=info:doi/10.1684/abc.2013.0926&rft_dat=%3Cproquest_pubme%3E1508944414%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1508944414&rft_id=info:pmid/24492101&rfr_iscdi=true |