Diffusing Fibre Tip for the Minimally Invasive Treatment of Liver Tumours by Interstitial Laser Coagulation (ILC): An Experimental Ex Vivo Study
A newly developed diffusing laser applicator was examined for interstitial laser coagulation (ILC) of liver tumours. The applicator consisted of a matted quartz core and a quartz glass dome, also matted on its inner surface and sealed to the fibre. The applicator provided a homogeneous light intensi...
Gespeichert in:
Veröffentlicht in: | Lasers in medical science 1999-03, Vol.14 (1), p.32-39 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 39 |
---|---|
container_issue | 1 |
container_start_page | 32 |
container_title | Lasers in medical science |
container_volume | 14 |
creator | Germer, C T Albrecht, D Isbert, C Ritz, J Roggan, A Buhr, H J |
description | A newly developed diffusing laser applicator was examined for interstitial laser coagulation (ILC) of liver tumours. The applicator consisted of a matted quartz core and a quartz glass dome, also matted on its inner surface and sealed to the fibre. The applicator provided a homogeneous light intensity distribution over an active length of about 20 mm. Lesions were created in an ex-vivo porcine liver model using a Nd-YAG laser comparing the new diffusing tip with a Ringmode(®)-ITT applicator in order to find optimal laser parameters and damage thresholds. The lesions were investigated using macroscopic size measurement, volume calculation and histological examination (H&E, NADPH-dehydrogenase). The damage threshold of the diffusing tip was 6 W at 14 min exposure time whereas the Ringmode(®)-ITT applicator had its limit at 5 W and 12 min exposure. Comparing various exposure times showed that treatment over a time of more than 840 s did not significantly increase the lesion volume. At 5 W and 720 s the mean lesion volume was 6.9±1.1 cm(3) with the diffusing tip and 6.3±0.6 cm(3) with the Ringmode(®)-ITT applicator, both having a slight ellipsoidal shape. Hence, the created lesions were not significantly different for both applicators when the same laser parameters were applied. On the other hand, the new diffusing tip had a higher damage threshold and was therefore capable of producing maximal coagulation volumes of up to 7.9±0.5 cm(3) at 5 W and 20 min. The experiments showed that lesions with a dimension of 31×22 mm can be achieved with the diffusing applicator which seem suitably sized for treating small human liver metastases in a single laser session. |
doi_str_mv | 10.1007/s101030050018 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1504150576</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1504150576</sourcerecordid><originalsourceid>FETCH-LOGICAL-c291t-e1fd6e376d9d7d9b6ef65f60b829cbfa757d8d9f95218ce43c5e55646cf074523</originalsourceid><addsrcrecordid>eNpVkc1OwzAQhC0EgvJz5Ip8LIeAncROwq0KBSoFcaAgbpGTrItREhfbqdq34JFxRUHisFpp59NoNYPQOSVXlJDk2lJCSUQII4Sme2hE44gFnMRv-2hEQp4GaRbSI3Rs7YcnEk6jQ3QUxiyNU5KN0NetknKwql_gO1UZwHO1xFIb7N4BP6pedaJtN3jWr4RVKy8bEK6D3mEtceEvBs-HTg_G4mqLOTDWKadEiwthvZprsRha4ZTu8XhW5Jc3eNLj6XoJRm19PDhd41e10vjZDc3mFB1I0Vo42-0T9HI3necPQfF0P8snRVCHGXUBUNlwiBLeZE3SZBUHyZnkpErDrK6kSFjSpE0mMxbStIY4qhkwxmNeS5LELIxO0PjHd2n05wDWlZ2yNbSt6EEPtqSMxH5Ywj0a_KC10dYakOXS_y7MpqSk3JZQ_ivB8xc766HqoPmjf1OPvgEIe4K4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1504150576</pqid></control><display><type>article</type><title>Diffusing Fibre Tip for the Minimally Invasive Treatment of Liver Tumours by Interstitial Laser Coagulation (ILC): An Experimental Ex Vivo Study</title><source>SpringerNature Journals</source><creator>Germer, C T ; Albrecht, D ; Isbert, C ; Ritz, J ; Roggan, A ; Buhr, H J</creator><creatorcontrib>Germer, C T ; Albrecht, D ; Isbert, C ; Ritz, J ; Roggan, A ; Buhr, H J</creatorcontrib><description>A newly developed diffusing laser applicator was examined for interstitial laser coagulation (ILC) of liver tumours. The applicator consisted of a matted quartz core and a quartz glass dome, also matted on its inner surface and sealed to the fibre. The applicator provided a homogeneous light intensity distribution over an active length of about 20 mm. Lesions were created in an ex-vivo porcine liver model using a Nd-YAG laser comparing the new diffusing tip with a Ringmode(®)-ITT applicator in order to find optimal laser parameters and damage thresholds. The lesions were investigated using macroscopic size measurement, volume calculation and histological examination (H&E, NADPH-dehydrogenase). The damage threshold of the diffusing tip was 6 W at 14 min exposure time whereas the Ringmode(®)-ITT applicator had its limit at 5 W and 12 min exposure. Comparing various exposure times showed that treatment over a time of more than 840 s did not significantly increase the lesion volume. At 5 W and 720 s the mean lesion volume was 6.9±1.1 cm(3) with the diffusing tip and 6.3±0.6 cm(3) with the Ringmode(®)-ITT applicator, both having a slight ellipsoidal shape. Hence, the created lesions were not significantly different for both applicators when the same laser parameters were applied. On the other hand, the new diffusing tip had a higher damage threshold and was therefore capable of producing maximal coagulation volumes of up to 7.9±0.5 cm(3) at 5 W and 20 min. The experiments showed that lesions with a dimension of 31×22 mm can be achieved with the diffusing applicator which seem suitably sized for treating small human liver metastases in a single laser session.</description><identifier>ISSN: 0268-8921</identifier><identifier>EISSN: 1435-604X</identifier><identifier>DOI: 10.1007/s101030050018</identifier><identifier>PMID: 24584809</identifier><language>eng</language><publisher>England</publisher><ispartof>Lasers in medical science, 1999-03, Vol.14 (1), p.32-39</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c291t-e1fd6e376d9d7d9b6ef65f60b829cbfa757d8d9f95218ce43c5e55646cf074523</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,27929,27930</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24584809$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Germer, C T</creatorcontrib><creatorcontrib>Albrecht, D</creatorcontrib><creatorcontrib>Isbert, C</creatorcontrib><creatorcontrib>Ritz, J</creatorcontrib><creatorcontrib>Roggan, A</creatorcontrib><creatorcontrib>Buhr, H J</creatorcontrib><title>Diffusing Fibre Tip for the Minimally Invasive Treatment of Liver Tumours by Interstitial Laser Coagulation (ILC): An Experimental Ex Vivo Study</title><title>Lasers in medical science</title><addtitle>Lasers Med Sci</addtitle><description>A newly developed diffusing laser applicator was examined for interstitial laser coagulation (ILC) of liver tumours. The applicator consisted of a matted quartz core and a quartz glass dome, also matted on its inner surface and sealed to the fibre. The applicator provided a homogeneous light intensity distribution over an active length of about 20 mm. Lesions were created in an ex-vivo porcine liver model using a Nd-YAG laser comparing the new diffusing tip with a Ringmode(®)-ITT applicator in order to find optimal laser parameters and damage thresholds. The lesions were investigated using macroscopic size measurement, volume calculation and histological examination (H&E, NADPH-dehydrogenase). The damage threshold of the diffusing tip was 6 W at 14 min exposure time whereas the Ringmode(®)-ITT applicator had its limit at 5 W and 12 min exposure. Comparing various exposure times showed that treatment over a time of more than 840 s did not significantly increase the lesion volume. At 5 W and 720 s the mean lesion volume was 6.9±1.1 cm(3) with the diffusing tip and 6.3±0.6 cm(3) with the Ringmode(®)-ITT applicator, both having a slight ellipsoidal shape. Hence, the created lesions were not significantly different for both applicators when the same laser parameters were applied. On the other hand, the new diffusing tip had a higher damage threshold and was therefore capable of producing maximal coagulation volumes of up to 7.9±0.5 cm(3) at 5 W and 20 min. The experiments showed that lesions with a dimension of 31×22 mm can be achieved with the diffusing applicator which seem suitably sized for treating small human liver metastases in a single laser session.</description><issn>0268-8921</issn><issn>1435-604X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><recordid>eNpVkc1OwzAQhC0EgvJz5Ip8LIeAncROwq0KBSoFcaAgbpGTrItREhfbqdq34JFxRUHisFpp59NoNYPQOSVXlJDk2lJCSUQII4Sme2hE44gFnMRv-2hEQp4GaRbSI3Rs7YcnEk6jQ3QUxiyNU5KN0NetknKwql_gO1UZwHO1xFIb7N4BP6pedaJtN3jWr4RVKy8bEK6D3mEtceEvBs-HTg_G4mqLOTDWKadEiwthvZprsRha4ZTu8XhW5Jc3eNLj6XoJRm19PDhd41e10vjZDc3mFB1I0Vo42-0T9HI3necPQfF0P8snRVCHGXUBUNlwiBLeZE3SZBUHyZnkpErDrK6kSFjSpE0mMxbStIY4qhkwxmNeS5LELIxO0PjHd2n05wDWlZ2yNbSt6EEPtqSMxH5Ywj0a_KC10dYakOXS_y7MpqSk3JZQ_ivB8xc766HqoPmjf1OPvgEIe4K4</recordid><startdate>199903</startdate><enddate>199903</enddate><creator>Germer, C T</creator><creator>Albrecht, D</creator><creator>Isbert, C</creator><creator>Ritz, J</creator><creator>Roggan, A</creator><creator>Buhr, H J</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199903</creationdate><title>Diffusing Fibre Tip for the Minimally Invasive Treatment of Liver Tumours by Interstitial Laser Coagulation (ILC): An Experimental Ex Vivo Study</title><author>Germer, C T ; Albrecht, D ; Isbert, C ; Ritz, J ; Roggan, A ; Buhr, H J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c291t-e1fd6e376d9d7d9b6ef65f60b829cbfa757d8d9f95218ce43c5e55646cf074523</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Germer, C T</creatorcontrib><creatorcontrib>Albrecht, D</creatorcontrib><creatorcontrib>Isbert, C</creatorcontrib><creatorcontrib>Ritz, J</creatorcontrib><creatorcontrib>Roggan, A</creatorcontrib><creatorcontrib>Buhr, H J</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Lasers in medical science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Germer, C T</au><au>Albrecht, D</au><au>Isbert, C</au><au>Ritz, J</au><au>Roggan, A</au><au>Buhr, H J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Diffusing Fibre Tip for the Minimally Invasive Treatment of Liver Tumours by Interstitial Laser Coagulation (ILC): An Experimental Ex Vivo Study</atitle><jtitle>Lasers in medical science</jtitle><addtitle>Lasers Med Sci</addtitle><date>1999-03</date><risdate>1999</risdate><volume>14</volume><issue>1</issue><spage>32</spage><epage>39</epage><pages>32-39</pages><issn>0268-8921</issn><eissn>1435-604X</eissn><abstract>A newly developed diffusing laser applicator was examined for interstitial laser coagulation (ILC) of liver tumours. The applicator consisted of a matted quartz core and a quartz glass dome, also matted on its inner surface and sealed to the fibre. The applicator provided a homogeneous light intensity distribution over an active length of about 20 mm. Lesions were created in an ex-vivo porcine liver model using a Nd-YAG laser comparing the new diffusing tip with a Ringmode(®)-ITT applicator in order to find optimal laser parameters and damage thresholds. The lesions were investigated using macroscopic size measurement, volume calculation and histological examination (H&E, NADPH-dehydrogenase). The damage threshold of the diffusing tip was 6 W at 14 min exposure time whereas the Ringmode(®)-ITT applicator had its limit at 5 W and 12 min exposure. Comparing various exposure times showed that treatment over a time of more than 840 s did not significantly increase the lesion volume. At 5 W and 720 s the mean lesion volume was 6.9±1.1 cm(3) with the diffusing tip and 6.3±0.6 cm(3) with the Ringmode(®)-ITT applicator, both having a slight ellipsoidal shape. Hence, the created lesions were not significantly different for both applicators when the same laser parameters were applied. On the other hand, the new diffusing tip had a higher damage threshold and was therefore capable of producing maximal coagulation volumes of up to 7.9±0.5 cm(3) at 5 W and 20 min. The experiments showed that lesions with a dimension of 31×22 mm can be achieved with the diffusing applicator which seem suitably sized for treating small human liver metastases in a single laser session.</abstract><cop>England</cop><pmid>24584809</pmid><doi>10.1007/s101030050018</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0268-8921 |
ispartof | Lasers in medical science, 1999-03, Vol.14 (1), p.32-39 |
issn | 0268-8921 1435-604X |
language | eng |
recordid | cdi_proquest_miscellaneous_1504150576 |
source | SpringerNature Journals |
title | Diffusing Fibre Tip for the Minimally Invasive Treatment of Liver Tumours by Interstitial Laser Coagulation (ILC): An Experimental Ex Vivo Study |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-11T12%3A32%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Diffusing%20Fibre%20Tip%20for%20the%20Minimally%20Invasive%20Treatment%20of%20Liver%20Tumours%20by%20Interstitial%20Laser%20Coagulation%20(ILC):%20An%20Experimental%20Ex%20Vivo%20Study&rft.jtitle=Lasers%20in%20medical%20science&rft.au=Germer,%20C%20T&rft.date=1999-03&rft.volume=14&rft.issue=1&rft.spage=32&rft.epage=39&rft.pages=32-39&rft.issn=0268-8921&rft.eissn=1435-604X&rft_id=info:doi/10.1007/s101030050018&rft_dat=%3Cproquest_cross%3E1504150576%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1504150576&rft_id=info:pmid/24584809&rfr_iscdi=true |