Modified phased radiofrequency ablation of atrial fibrillation reduces the number of cerebral microembolic signals

Phased radiofrequency (RF) ablation for atrial fibrillation is associated with an increased number of silent cerebral lesions on magnetic resonance imaging and cerebral microembolic signals (MESs) on transcranial Doppler ultrasound imaging compared with irrigated RF. The increased rate of embolic ev...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Europace (London, England) England), 2014-03, Vol.16 (3), p.341-346
Hauptverfasser: Zellerhoff, Stephan, Ritter, Martin A, Kochhäuser, Simon, Dittrich, Ralf, Köbe, Julia, Milberg, Peter, Korsukewitz, Catharina, Dechering, Dirk G, Pott, Christian, Wasmer, Kristina, Leitz, Patrick, Güner, Fatih, Eckardt, Lars, Mönnig, Gerold
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 346
container_issue 3
container_start_page 341
container_title Europace (London, England)
container_volume 16
creator Zellerhoff, Stephan
Ritter, Martin A
Kochhäuser, Simon
Dittrich, Ralf
Köbe, Julia
Milberg, Peter
Korsukewitz, Catharina
Dechering, Dirk G
Pott, Christian
Wasmer, Kristina
Leitz, Patrick
Güner, Fatih
Eckardt, Lars
Mönnig, Gerold
description Phased radiofrequency (RF) ablation for atrial fibrillation is associated with an increased number of silent cerebral lesions on magnetic resonance imaging and cerebral microembolic signals (MESs) on transcranial Doppler ultrasound imaging compared with irrigated RF. The increased rate of embolic events may be due to a specific electrical interference of ablation electrodes attributed to the catheter design. The purpose of this study was to elucidate the effect of deactivating the culprit electrodes on cerebral MESs. Twenty-nine consecutive patients (60 ± 11 years, 10 female) underwent their first pulmonary vein isolation using phased RF energy. Electrode pairs 1 or 5 were deactivated to avoid electrical interference between electrodes 1 and 10 ('modified'). Detection of MESs by transcranial Doppler ultrasound was performed throughout the procedure to assess cerebral microembolism. Results were compared with the numbers of MESs in 31 patients ablated using all available electrodes ('conventional') and to 30 patients undergoing irrigated RF ablation of a previous randomized study. Ablation with 'modified' phased RF was associated with a marked decrease in MESs when compared with 'conventional' phased RF (566 ± 332 vs. 1530 ± 980; P < 0.001). This difference was mainly triggered by the reduction of MES during delivery of phased RF energy, resulting in MES numbers comparable to irrigated RF ablation (646 ± 449; P = 0.7). Total procedure duration as well as time of RF delivery was comparable between phased RF groups. Both times, however, were significantly shorter compared with the irrigated RF group (123 ± 28 vs. 195 ± 38; 15 ± 4 vs. 30 ± 9; P < 0.001, respectively). Pulmonary vein isolation with 'modified' phased RF is associated with a decreased number of cerebral microembolism especially during the delivery of ablation impulses, supporting the significance of electrical interference between ablation electrodes 1 and 10. Deactivation of electrode pairs 1 or 5 might increase the safety of this approach without an increase in procedure duration or RF delivery time.
doi_str_mv 10.1093/europace/eut282
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1502996794</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1502996794</sourcerecordid><originalsourceid>FETCH-LOGICAL-c338t-d1b69d3fd48f71889025891e1b2de2b60b7a81a5d84ab2cd9d77460ee220090b3</originalsourceid><addsrcrecordid>eNo9kDlPAzEQhS0EIiFQ0yGXNEt87GGXKOKSgmigXvkYE6PddbB3i_x7HCWhek-jb55mHkK3lDxQIvkSphi2ykA2IxPsDM1pxVnBiGTn2RMpi4oyOUNXKf0QQhomq0s0Y2V2ZcnnKL4H650Hi7cblbJEZX1wEX4nGMwOK92p0YcBB4fVGL3qsPM6-u44jmAnAwmPG8DD1GuIe9JABB0z23sTA_Q6dN7g5L8H1aVrdOGywM1RF-jr-elz9VqsP17eVo_rwnAuxsJSXUvLnS2Fa6gQkrBKSApUMwtM10Q3SlBVWVEqzYyVtmnKmgAwRogkmi_Q_SF3G0P-Jo1t75OBfPkAYUotrQiTsm5kmdHlAc3XphTBtdvoexV3LSXtvuj2VHR7KDpv3B3DJ92D_edPzfI_fJp-1Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1502996794</pqid></control><display><type>article</type><title>Modified phased radiofrequency ablation of atrial fibrillation reduces the number of cerebral microembolic signals</title><source>MEDLINE</source><source>Access via Oxford University Press (Open Access Collection)</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Zellerhoff, Stephan ; Ritter, Martin A ; Kochhäuser, Simon ; Dittrich, Ralf ; Köbe, Julia ; Milberg, Peter ; Korsukewitz, Catharina ; Dechering, Dirk G ; Pott, Christian ; Wasmer, Kristina ; Leitz, Patrick ; Güner, Fatih ; Eckardt, Lars ; Mönnig, Gerold</creator><creatorcontrib>Zellerhoff, Stephan ; Ritter, Martin A ; Kochhäuser, Simon ; Dittrich, Ralf ; Köbe, Julia ; Milberg, Peter ; Korsukewitz, Catharina ; Dechering, Dirk G ; Pott, Christian ; Wasmer, Kristina ; Leitz, Patrick ; Güner, Fatih ; Eckardt, Lars ; Mönnig, Gerold</creatorcontrib><description>Phased radiofrequency (RF) ablation for atrial fibrillation is associated with an increased number of silent cerebral lesions on magnetic resonance imaging and cerebral microembolic signals (MESs) on transcranial Doppler ultrasound imaging compared with irrigated RF. The increased rate of embolic events may be due to a specific electrical interference of ablation electrodes attributed to the catheter design. The purpose of this study was to elucidate the effect of deactivating the culprit electrodes on cerebral MESs. Twenty-nine consecutive patients (60 ± 11 years, 10 female) underwent their first pulmonary vein isolation using phased RF energy. Electrode pairs 1 or 5 were deactivated to avoid electrical interference between electrodes 1 and 10 ('modified'). Detection of MESs by transcranial Doppler ultrasound was performed throughout the procedure to assess cerebral microembolism. Results were compared with the numbers of MESs in 31 patients ablated using all available electrodes ('conventional') and to 30 patients undergoing irrigated RF ablation of a previous randomized study. Ablation with 'modified' phased RF was associated with a marked decrease in MESs when compared with 'conventional' phased RF (566 ± 332 vs. 1530 ± 980; P &lt; 0.001). This difference was mainly triggered by the reduction of MES during delivery of phased RF energy, resulting in MES numbers comparable to irrigated RF ablation (646 ± 449; P = 0.7). Total procedure duration as well as time of RF delivery was comparable between phased RF groups. Both times, however, were significantly shorter compared with the irrigated RF group (123 ± 28 vs. 195 ± 38; 15 ± 4 vs. 30 ± 9; P &lt; 0.001, respectively). Pulmonary vein isolation with 'modified' phased RF is associated with a decreased number of cerebral microembolism especially during the delivery of ablation impulses, supporting the significance of electrical interference between ablation electrodes 1 and 10. Deactivation of electrode pairs 1 or 5 might increase the safety of this approach without an increase in procedure duration or RF delivery time.</description><identifier>ISSN: 1099-5129</identifier><identifier>EISSN: 1532-2092</identifier><identifier>DOI: 10.1093/europace/eut282</identifier><identifier>PMID: 24072443</identifier><language>eng</language><publisher>England</publisher><subject>Atrial Fibrillation - complications ; Atrial Fibrillation - diagnosis ; Atrial Fibrillation - surgery ; Catheter Ablation - adverse effects ; Catheter Ablation - methods ; Female ; Humans ; Intracranial Embolism - diagnosis ; Intracranial Embolism - etiology ; Intracranial Embolism - prevention &amp; control ; Male ; Middle Aged ; Pulmonary Veins - surgery ; Treatment Outcome</subject><ispartof>Europace (London, England), 2014-03, Vol.16 (3), p.341-346</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c338t-d1b69d3fd48f71889025891e1b2de2b60b7a81a5d84ab2cd9d77460ee220090b3</citedby><cites>FETCH-LOGICAL-c338t-d1b69d3fd48f71889025891e1b2de2b60b7a81a5d84ab2cd9d77460ee220090b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,27929,27930</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24072443$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zellerhoff, Stephan</creatorcontrib><creatorcontrib>Ritter, Martin A</creatorcontrib><creatorcontrib>Kochhäuser, Simon</creatorcontrib><creatorcontrib>Dittrich, Ralf</creatorcontrib><creatorcontrib>Köbe, Julia</creatorcontrib><creatorcontrib>Milberg, Peter</creatorcontrib><creatorcontrib>Korsukewitz, Catharina</creatorcontrib><creatorcontrib>Dechering, Dirk G</creatorcontrib><creatorcontrib>Pott, Christian</creatorcontrib><creatorcontrib>Wasmer, Kristina</creatorcontrib><creatorcontrib>Leitz, Patrick</creatorcontrib><creatorcontrib>Güner, Fatih</creatorcontrib><creatorcontrib>Eckardt, Lars</creatorcontrib><creatorcontrib>Mönnig, Gerold</creatorcontrib><title>Modified phased radiofrequency ablation of atrial fibrillation reduces the number of cerebral microembolic signals</title><title>Europace (London, England)</title><addtitle>Europace</addtitle><description>Phased radiofrequency (RF) ablation for atrial fibrillation is associated with an increased number of silent cerebral lesions on magnetic resonance imaging and cerebral microembolic signals (MESs) on transcranial Doppler ultrasound imaging compared with irrigated RF. The increased rate of embolic events may be due to a specific electrical interference of ablation electrodes attributed to the catheter design. The purpose of this study was to elucidate the effect of deactivating the culprit electrodes on cerebral MESs. Twenty-nine consecutive patients (60 ± 11 years, 10 female) underwent their first pulmonary vein isolation using phased RF energy. Electrode pairs 1 or 5 were deactivated to avoid electrical interference between electrodes 1 and 10 ('modified'). Detection of MESs by transcranial Doppler ultrasound was performed throughout the procedure to assess cerebral microembolism. Results were compared with the numbers of MESs in 31 patients ablated using all available electrodes ('conventional') and to 30 patients undergoing irrigated RF ablation of a previous randomized study. Ablation with 'modified' phased RF was associated with a marked decrease in MESs when compared with 'conventional' phased RF (566 ± 332 vs. 1530 ± 980; P &lt; 0.001). This difference was mainly triggered by the reduction of MES during delivery of phased RF energy, resulting in MES numbers comparable to irrigated RF ablation (646 ± 449; P = 0.7). Total procedure duration as well as time of RF delivery was comparable between phased RF groups. Both times, however, were significantly shorter compared with the irrigated RF group (123 ± 28 vs. 195 ± 38; 15 ± 4 vs. 30 ± 9; P &lt; 0.001, respectively). Pulmonary vein isolation with 'modified' phased RF is associated with a decreased number of cerebral microembolism especially during the delivery of ablation impulses, supporting the significance of electrical interference between ablation electrodes 1 and 10. Deactivation of electrode pairs 1 or 5 might increase the safety of this approach without an increase in procedure duration or RF delivery time.</description><subject>Atrial Fibrillation - complications</subject><subject>Atrial Fibrillation - diagnosis</subject><subject>Atrial Fibrillation - surgery</subject><subject>Catheter Ablation - adverse effects</subject><subject>Catheter Ablation - methods</subject><subject>Female</subject><subject>Humans</subject><subject>Intracranial Embolism - diagnosis</subject><subject>Intracranial Embolism - etiology</subject><subject>Intracranial Embolism - prevention &amp; control</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Pulmonary Veins - surgery</subject><subject>Treatment Outcome</subject><issn>1099-5129</issn><issn>1532-2092</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kDlPAzEQhS0EIiFQ0yGXNEt87GGXKOKSgmigXvkYE6PddbB3i_x7HCWhek-jb55mHkK3lDxQIvkSphi2ykA2IxPsDM1pxVnBiGTn2RMpi4oyOUNXKf0QQhomq0s0Y2V2ZcnnKL4H650Hi7cblbJEZX1wEX4nGMwOK92p0YcBB4fVGL3qsPM6-u44jmAnAwmPG8DD1GuIe9JABB0z23sTA_Q6dN7g5L8H1aVrdOGywM1RF-jr-elz9VqsP17eVo_rwnAuxsJSXUvLnS2Fa6gQkrBKSApUMwtM10Q3SlBVWVEqzYyVtmnKmgAwRogkmi_Q_SF3G0P-Jo1t75OBfPkAYUotrQiTsm5kmdHlAc3XphTBtdvoexV3LSXtvuj2VHR7KDpv3B3DJ92D_edPzfI_fJp-1Q</recordid><startdate>20140301</startdate><enddate>20140301</enddate><creator>Zellerhoff, Stephan</creator><creator>Ritter, Martin A</creator><creator>Kochhäuser, Simon</creator><creator>Dittrich, Ralf</creator><creator>Köbe, Julia</creator><creator>Milberg, Peter</creator><creator>Korsukewitz, Catharina</creator><creator>Dechering, Dirk G</creator><creator>Pott, Christian</creator><creator>Wasmer, Kristina</creator><creator>Leitz, Patrick</creator><creator>Güner, Fatih</creator><creator>Eckardt, Lars</creator><creator>Mönnig, Gerold</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20140301</creationdate><title>Modified phased radiofrequency ablation of atrial fibrillation reduces the number of cerebral microembolic signals</title><author>Zellerhoff, Stephan ; Ritter, Martin A ; Kochhäuser, Simon ; Dittrich, Ralf ; Köbe, Julia ; Milberg, Peter ; Korsukewitz, Catharina ; Dechering, Dirk G ; Pott, Christian ; Wasmer, Kristina ; Leitz, Patrick ; Güner, Fatih ; Eckardt, Lars ; Mönnig, Gerold</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c338t-d1b69d3fd48f71889025891e1b2de2b60b7a81a5d84ab2cd9d77460ee220090b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Atrial Fibrillation - complications</topic><topic>Atrial Fibrillation - diagnosis</topic><topic>Atrial Fibrillation - surgery</topic><topic>Catheter Ablation - adverse effects</topic><topic>Catheter Ablation - methods</topic><topic>Female</topic><topic>Humans</topic><topic>Intracranial Embolism - diagnosis</topic><topic>Intracranial Embolism - etiology</topic><topic>Intracranial Embolism - prevention &amp; control</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Pulmonary Veins - surgery</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zellerhoff, Stephan</creatorcontrib><creatorcontrib>Ritter, Martin A</creatorcontrib><creatorcontrib>Kochhäuser, Simon</creatorcontrib><creatorcontrib>Dittrich, Ralf</creatorcontrib><creatorcontrib>Köbe, Julia</creatorcontrib><creatorcontrib>Milberg, Peter</creatorcontrib><creatorcontrib>Korsukewitz, Catharina</creatorcontrib><creatorcontrib>Dechering, Dirk G</creatorcontrib><creatorcontrib>Pott, Christian</creatorcontrib><creatorcontrib>Wasmer, Kristina</creatorcontrib><creatorcontrib>Leitz, Patrick</creatorcontrib><creatorcontrib>Güner, Fatih</creatorcontrib><creatorcontrib>Eckardt, Lars</creatorcontrib><creatorcontrib>Mönnig, Gerold</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Europace (London, England)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zellerhoff, Stephan</au><au>Ritter, Martin A</au><au>Kochhäuser, Simon</au><au>Dittrich, Ralf</au><au>Köbe, Julia</au><au>Milberg, Peter</au><au>Korsukewitz, Catharina</au><au>Dechering, Dirk G</au><au>Pott, Christian</au><au>Wasmer, Kristina</au><au>Leitz, Patrick</au><au>Güner, Fatih</au><au>Eckardt, Lars</au><au>Mönnig, Gerold</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Modified phased radiofrequency ablation of atrial fibrillation reduces the number of cerebral microembolic signals</atitle><jtitle>Europace (London, England)</jtitle><addtitle>Europace</addtitle><date>2014-03-01</date><risdate>2014</risdate><volume>16</volume><issue>3</issue><spage>341</spage><epage>346</epage><pages>341-346</pages><issn>1099-5129</issn><eissn>1532-2092</eissn><abstract>Phased radiofrequency (RF) ablation for atrial fibrillation is associated with an increased number of silent cerebral lesions on magnetic resonance imaging and cerebral microembolic signals (MESs) on transcranial Doppler ultrasound imaging compared with irrigated RF. The increased rate of embolic events may be due to a specific electrical interference of ablation electrodes attributed to the catheter design. The purpose of this study was to elucidate the effect of deactivating the culprit electrodes on cerebral MESs. Twenty-nine consecutive patients (60 ± 11 years, 10 female) underwent their first pulmonary vein isolation using phased RF energy. Electrode pairs 1 or 5 were deactivated to avoid electrical interference between electrodes 1 and 10 ('modified'). Detection of MESs by transcranial Doppler ultrasound was performed throughout the procedure to assess cerebral microembolism. Results were compared with the numbers of MESs in 31 patients ablated using all available electrodes ('conventional') and to 30 patients undergoing irrigated RF ablation of a previous randomized study. Ablation with 'modified' phased RF was associated with a marked decrease in MESs when compared with 'conventional' phased RF (566 ± 332 vs. 1530 ± 980; P &lt; 0.001). This difference was mainly triggered by the reduction of MES during delivery of phased RF energy, resulting in MES numbers comparable to irrigated RF ablation (646 ± 449; P = 0.7). Total procedure duration as well as time of RF delivery was comparable between phased RF groups. Both times, however, were significantly shorter compared with the irrigated RF group (123 ± 28 vs. 195 ± 38; 15 ± 4 vs. 30 ± 9; P &lt; 0.001, respectively). Pulmonary vein isolation with 'modified' phased RF is associated with a decreased number of cerebral microembolism especially during the delivery of ablation impulses, supporting the significance of electrical interference between ablation electrodes 1 and 10. Deactivation of electrode pairs 1 or 5 might increase the safety of this approach without an increase in procedure duration or RF delivery time.</abstract><cop>England</cop><pmid>24072443</pmid><doi>10.1093/europace/eut282</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1099-5129
ispartof Europace (London, England), 2014-03, Vol.16 (3), p.341-346
issn 1099-5129
1532-2092
language eng
recordid cdi_proquest_miscellaneous_1502996794
source MEDLINE; Access via Oxford University Press (Open Access Collection); EZB-FREE-00999 freely available EZB journals; PubMed Central; Alma/SFX Local Collection
subjects Atrial Fibrillation - complications
Atrial Fibrillation - diagnosis
Atrial Fibrillation - surgery
Catheter Ablation - adverse effects
Catheter Ablation - methods
Female
Humans
Intracranial Embolism - diagnosis
Intracranial Embolism - etiology
Intracranial Embolism - prevention & control
Male
Middle Aged
Pulmonary Veins - surgery
Treatment Outcome
title Modified phased radiofrequency ablation of atrial fibrillation reduces the number of cerebral microembolic signals
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-12T02%3A20%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Modified%20phased%20radiofrequency%20ablation%20of%20atrial%20fibrillation%20reduces%20the%20number%20of%20cerebral%20microembolic%20signals&rft.jtitle=Europace%20(London,%20England)&rft.au=Zellerhoff,%20Stephan&rft.date=2014-03-01&rft.volume=16&rft.issue=3&rft.spage=341&rft.epage=346&rft.pages=341-346&rft.issn=1099-5129&rft.eissn=1532-2092&rft_id=info:doi/10.1093/europace/eut282&rft_dat=%3Cproquest_cross%3E1502996794%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1502996794&rft_id=info:pmid/24072443&rfr_iscdi=true