Evaluating and Improving Existing Ground-Water Systems

ABSTRACT Considerable energy savings are available from improving well and pump efficiencies. One major problem is evaluating the well and pump inefficiencies over prolonged periods of time, because these efficiencies are erratic unless normalized. A new well should be tested at different discharges...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ground water 1982-07, Vol.20 (4), p.402-409
1. Verfasser: Helweg, Otto J.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 409
container_issue 4
container_start_page 402
container_title Ground water
container_volume 20
creator Helweg, Otto J.
description ABSTRACT Considerable energy savings are available from improving well and pump efficiencies. One major problem is evaluating the well and pump inefficiencies over prolonged periods of time, because these efficiencies are erratic unless normalized. A new well should be tested at different discharges to construct a relationship between specific capacity and drawdown. Future well efficiency tests should compare the specific capacity with the original curve at the test discharge. The departure from the original curve indicates the loss in well efficiency. Similarly, pump efficiency needs to be normalized, so that the tested efficiency may be compared with the original efficiency at the test discharge.
doi_str_mv 10.1111/j.1745-6584.1982.tb02759.x
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_14971780</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>13874576</sourcerecordid><originalsourceid>FETCH-LOGICAL-a3862-1be40d53cb671de08e9d6a2e3b7a63c08c6e0c01f91d6fbf74085b549136a7d83</originalsourceid><addsrcrecordid>eNqVkV1LwzAUhoMoOKf_YXjhXetJ0-bDGxlj1sHwAyf1LqRtKp39mE07u39va8du1UMgnOR9Xw7PQegSg427ul7bmLmeRT3u2lhwx65DcJgn7PYIjQ5fx2gEgJnlUvZ2is6MWQMAESBGiM63KmtUnRbvE1XEk0W-qcpt383b1Pw8-1XZFLEVqFpXk5edqXVuztFJojKjL_b3GL3ezVeze2v56C9m06WlCKeOhUPtQuyRKKQMxxq4FjFVjiYhU5REwCOqIQKcCBzTJEyYC9wLPVdgQhWLORmjqyG3m-qz0aaWeWoinWWq0GVjJHYFw4zDH4SYEtKdX4WEd9gY7YQ3gzCqSmMqnchNleaq2kkMsocv17InLHvCsocv9_Bl25lvB_NXmundP5zSD6YrF5wuwRoSui3o9pCgqg9JGWGeDB58STwR-PTpWQryDWstmwA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>13874576</pqid></control><display><type>article</type><title>Evaluating and Improving Existing Ground-Water Systems</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Helweg, Otto J.</creator><creatorcontrib>Helweg, Otto J.</creatorcontrib><description>ABSTRACT Considerable energy savings are available from improving well and pump efficiencies. One major problem is evaluating the well and pump inefficiencies over prolonged periods of time, because these efficiencies are erratic unless normalized. A new well should be tested at different discharges to construct a relationship between specific capacity and drawdown. Future well efficiency tests should compare the specific capacity with the original curve at the test discharge. The departure from the original curve indicates the loss in well efficiency. Similarly, pump efficiency needs to be normalized, so that the tested efficiency may be compared with the original efficiency at the test discharge.</description><identifier>ISSN: 0017-467X</identifier><identifier>EISSN: 1745-6584</identifier><identifier>DOI: 10.1111/j.1745-6584.1982.tb02759.x</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Publishing Ltd</publisher><ispartof>Ground water, 1982-07, Vol.20 (4), p.402-409</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a3862-1be40d53cb671de08e9d6a2e3b7a63c08c6e0c01f91d6fbf74085b549136a7d83</citedby><cites>FETCH-LOGICAL-a3862-1be40d53cb671de08e9d6a2e3b7a63c08c6e0c01f91d6fbf74085b549136a7d83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1111%2Fj.1745-6584.1982.tb02759.x$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1111%2Fj.1745-6584.1982.tb02759.x$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,777,781,1412,27905,27906,45555,45556</link.rule.ids></links><search><creatorcontrib>Helweg, Otto J.</creatorcontrib><title>Evaluating and Improving Existing Ground-Water Systems</title><title>Ground water</title><description>ABSTRACT Considerable energy savings are available from improving well and pump efficiencies. One major problem is evaluating the well and pump inefficiencies over prolonged periods of time, because these efficiencies are erratic unless normalized. A new well should be tested at different discharges to construct a relationship between specific capacity and drawdown. Future well efficiency tests should compare the specific capacity with the original curve at the test discharge. The departure from the original curve indicates the loss in well efficiency. Similarly, pump efficiency needs to be normalized, so that the tested efficiency may be compared with the original efficiency at the test discharge.</description><issn>0017-467X</issn><issn>1745-6584</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1982</creationdate><recordtype>article</recordtype><recordid>eNqVkV1LwzAUhoMoOKf_YXjhXetJ0-bDGxlj1sHwAyf1LqRtKp39mE07u39va8du1UMgnOR9Xw7PQegSg427ul7bmLmeRT3u2lhwx65DcJgn7PYIjQ5fx2gEgJnlUvZ2is6MWQMAESBGiM63KmtUnRbvE1XEk0W-qcpt383b1Pw8-1XZFLEVqFpXk5edqXVuztFJojKjL_b3GL3ezVeze2v56C9m06WlCKeOhUPtQuyRKKQMxxq4FjFVjiYhU5REwCOqIQKcCBzTJEyYC9wLPVdgQhWLORmjqyG3m-qz0aaWeWoinWWq0GVjJHYFw4zDH4SYEtKdX4WEd9gY7YQ3gzCqSmMqnchNleaq2kkMsocv17InLHvCsocv9_Bl25lvB_NXmundP5zSD6YrF5wuwRoSui3o9pCgqg9JGWGeDB58STwR-PTpWQryDWstmwA</recordid><startdate>198207</startdate><enddate>198207</enddate><creator>Helweg, Otto J.</creator><general>Blackwell Publishing Ltd</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QH</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope></search><sort><creationdate>198207</creationdate><title>Evaluating and Improving Existing Ground-Water Systems</title><author>Helweg, Otto J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a3862-1be40d53cb671de08e9d6a2e3b7a63c08c6e0c01f91d6fbf74085b549136a7d83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1982</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Helweg, Otto J.</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><collection>Aqualine</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><jtitle>Ground water</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Helweg, Otto J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluating and Improving Existing Ground-Water Systems</atitle><jtitle>Ground water</jtitle><date>1982-07</date><risdate>1982</risdate><volume>20</volume><issue>4</issue><spage>402</spage><epage>409</epage><pages>402-409</pages><issn>0017-467X</issn><eissn>1745-6584</eissn><abstract>ABSTRACT Considerable energy savings are available from improving well and pump efficiencies. One major problem is evaluating the well and pump inefficiencies over prolonged periods of time, because these efficiencies are erratic unless normalized. A new well should be tested at different discharges to construct a relationship between specific capacity and drawdown. Future well efficiency tests should compare the specific capacity with the original curve at the test discharge. The departure from the original curve indicates the loss in well efficiency. Similarly, pump efficiency needs to be normalized, so that the tested efficiency may be compared with the original efficiency at the test discharge.</abstract><cop>Oxford, UK</cop><pub>Blackwell Publishing Ltd</pub><doi>10.1111/j.1745-6584.1982.tb02759.x</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0017-467X
ispartof Ground water, 1982-07, Vol.20 (4), p.402-409
issn 0017-467X
1745-6584
language eng
recordid cdi_proquest_miscellaneous_14971780
source Wiley Online Library Journals Frontfile Complete
title Evaluating and Improving Existing Ground-Water Systems
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T14%3A57%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluating%20and%20Improving%20Existing%20Ground-Water%20Systems&rft.jtitle=Ground%20water&rft.au=Helweg,%20Otto%20J.&rft.date=1982-07&rft.volume=20&rft.issue=4&rft.spage=402&rft.epage=409&rft.pages=402-409&rft.issn=0017-467X&rft.eissn=1745-6584&rft_id=info:doi/10.1111/j.1745-6584.1982.tb02759.x&rft_dat=%3Cproquest_cross%3E13874576%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=13874576&rft_id=info:pmid/&rfr_iscdi=true