A Controlled, Comparative Study of a Fixed-Bearing Versus Mobile-Bearing Ankle Arthroplasty

Background: Total ankle arthroplasty is available with fixed-bearing (FB) or mobile-bearing (MB) versions, and there is little consensus on the benefits and drawbacks of each type. This study aimed to compare clinical outcomes of statistically paired series of FB and MB versions of the same ankle pr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Foot & ankle international 2014-02, Vol.35 (2), p.131-140
Hauptverfasser: Gaudot, Fabrice, Colombier, Jean-Alain, Bonnin, Michel, Judet, Thierry
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 140
container_issue 2
container_start_page 131
container_title Foot & ankle international
container_volume 35
creator Gaudot, Fabrice
Colombier, Jean-Alain
Bonnin, Michel
Judet, Thierry
description Background: Total ankle arthroplasty is available with fixed-bearing (FB) or mobile-bearing (MB) versions, and there is little consensus on the benefits and drawbacks of each type. This study aimed to compare clinical outcomes of statistically paired series of FB and MB versions of the same ankle prosthesis. Methods: The study was a multicenter retrospective comparison between 2 groups: the FB group of 33 consecutive Talaris cases and the MB group of 33 “paired” Salto cases, selected from a database of 313 consecutive cases to statistically match etiology, age, and preoperative American Orthopaedic Foot & Ankle Society (AOFAS) score. All patients were operated upon with the same operative technique and received identical pre- and postoperative clinical and radiographic assessments. The mean follow-up was 24 months for the FB group and 23 months for the MB group. Results: There was no statistical difference between results of the 2 groups in terms of accuracy of positioning, clinical and radiographic mobility, and morbidity. The most recent postoperative AOFAS scores were higher for the FB group than for the MB group (P = .05). Radiolucent lines were observed in 4 FB patients versus 13 MB patients (P = .02). Subchondral cysts were noted in 1 FB patient and in 8 MB patients (P = .01). Conclusion: There was no notable difference in clinical performance of the FB and MB implants with the numbers available. This short-term study demonstrated that FB ankle arthroplasty had results equivalent to, if not better than, MB ankle arthroplasty. Longer follow-up is necessary to determine the success of this new generation of ankle arthroplasty. Level of Evidence: Level III, retrospective case control study.
doi_str_mv 10.1177/1071100713517094
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1493800503</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1071100713517094</sage_id><sourcerecordid>1493800503</sourcerecordid><originalsourceid>FETCH-LOGICAL-c337t-9e616b3b776d625e68ddcf71a478e824a54c6acab37c99beddf5167bfca38b8f3</originalsourceid><addsrcrecordid>eNp1UDtPwzAQthCIlsLOhDwyELDrxE7GUFFAKmLgsTBEdnwpKU5c7ATRf4-rlg5ILHen-x66-xA6peSSUiGuKBGUklBYQgXJ4j00pFkcRyIVfD_MAYnW-AAdeb8ghApGs0M0GMdBwBM-RG85nti2c9YY0BdhbpbSya7-AvzU9XqFbYUlntbfoKNrkK5u5_gVnO89frCqNrDb5u2HAZy77t3ZpZG-Wx2jg0oaDyfbPkIv05vnyV00e7y9n-SzqGRMdFEGnHLFlBBc83ECPNW6rASVsUghHccyiUsuS6mYKLNMgdZVOF6oqpQsVWnFRuh847t09rMH3xVN7UswRrZge1_QOGMpIQlhgUo21NJZ7x1UxdLVjXSrgpJiHWnxN9IgOdu696oBvRP8ZhgI0Ybg5RyKhe1dG7793_AHwFl9-w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1493800503</pqid></control><display><type>article</type><title>A Controlled, Comparative Study of a Fixed-Bearing Versus Mobile-Bearing Ankle Arthroplasty</title><source>MEDLINE</source><source>SAGE Journals</source><creator>Gaudot, Fabrice ; Colombier, Jean-Alain ; Bonnin, Michel ; Judet, Thierry</creator><creatorcontrib>Gaudot, Fabrice ; Colombier, Jean-Alain ; Bonnin, Michel ; Judet, Thierry</creatorcontrib><description>Background: Total ankle arthroplasty is available with fixed-bearing (FB) or mobile-bearing (MB) versions, and there is little consensus on the benefits and drawbacks of each type. This study aimed to compare clinical outcomes of statistically paired series of FB and MB versions of the same ankle prosthesis. Methods: The study was a multicenter retrospective comparison between 2 groups: the FB group of 33 consecutive Talaris cases and the MB group of 33 “paired” Salto cases, selected from a database of 313 consecutive cases to statistically match etiology, age, and preoperative American Orthopaedic Foot &amp; Ankle Society (AOFAS) score. All patients were operated upon with the same operative technique and received identical pre- and postoperative clinical and radiographic assessments. The mean follow-up was 24 months for the FB group and 23 months for the MB group. Results: There was no statistical difference between results of the 2 groups in terms of accuracy of positioning, clinical and radiographic mobility, and morbidity. The most recent postoperative AOFAS scores were higher for the FB group than for the MB group (P = .05). Radiolucent lines were observed in 4 FB patients versus 13 MB patients (P = .02). Subchondral cysts were noted in 1 FB patient and in 8 MB patients (P = .01). Conclusion: There was no notable difference in clinical performance of the FB and MB implants with the numbers available. This short-term study demonstrated that FB ankle arthroplasty had results equivalent to, if not better than, MB ankle arthroplasty. Longer follow-up is necessary to determine the success of this new generation of ankle arthroplasty. Level of Evidence: Level III, retrospective case control study.</description><identifier>ISSN: 1071-1007</identifier><identifier>EISSN: 1944-7876</identifier><identifier>DOI: 10.1177/1071100713517094</identifier><identifier>PMID: 24351656</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><subject>Adult ; Aged ; Ankle Joint - surgery ; Arthroplasty, Replacement, Ankle - adverse effects ; Arthroplasty, Replacement, Ankle - instrumentation ; Arthroplasty, Replacement, Ankle - methods ; Female ; Follow-Up Studies ; Humans ; Joint Prosthesis - adverse effects ; Male ; Middle Aged ; Prosthesis Design ; Retrospective Studies ; Treatment Outcome ; Weight-Bearing</subject><ispartof>Foot &amp; ankle international, 2014-02, Vol.35 (2), p.131-140</ispartof><rights>The Author(s) 2013</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c337t-9e616b3b776d625e68ddcf71a478e824a54c6acab37c99beddf5167bfca38b8f3</citedby><cites>FETCH-LOGICAL-c337t-9e616b3b776d625e68ddcf71a478e824a54c6acab37c99beddf5167bfca38b8f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/1071100713517094$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/1071100713517094$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24351656$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gaudot, Fabrice</creatorcontrib><creatorcontrib>Colombier, Jean-Alain</creatorcontrib><creatorcontrib>Bonnin, Michel</creatorcontrib><creatorcontrib>Judet, Thierry</creatorcontrib><title>A Controlled, Comparative Study of a Fixed-Bearing Versus Mobile-Bearing Ankle Arthroplasty</title><title>Foot &amp; ankle international</title><addtitle>Foot Ankle Int</addtitle><description>Background: Total ankle arthroplasty is available with fixed-bearing (FB) or mobile-bearing (MB) versions, and there is little consensus on the benefits and drawbacks of each type. This study aimed to compare clinical outcomes of statistically paired series of FB and MB versions of the same ankle prosthesis. Methods: The study was a multicenter retrospective comparison between 2 groups: the FB group of 33 consecutive Talaris cases and the MB group of 33 “paired” Salto cases, selected from a database of 313 consecutive cases to statistically match etiology, age, and preoperative American Orthopaedic Foot &amp; Ankle Society (AOFAS) score. All patients were operated upon with the same operative technique and received identical pre- and postoperative clinical and radiographic assessments. The mean follow-up was 24 months for the FB group and 23 months for the MB group. Results: There was no statistical difference between results of the 2 groups in terms of accuracy of positioning, clinical and radiographic mobility, and morbidity. The most recent postoperative AOFAS scores were higher for the FB group than for the MB group (P = .05). Radiolucent lines were observed in 4 FB patients versus 13 MB patients (P = .02). Subchondral cysts were noted in 1 FB patient and in 8 MB patients (P = .01). Conclusion: There was no notable difference in clinical performance of the FB and MB implants with the numbers available. This short-term study demonstrated that FB ankle arthroplasty had results equivalent to, if not better than, MB ankle arthroplasty. Longer follow-up is necessary to determine the success of this new generation of ankle arthroplasty. Level of Evidence: Level III, retrospective case control study.</description><subject>Adult</subject><subject>Aged</subject><subject>Ankle Joint - surgery</subject><subject>Arthroplasty, Replacement, Ankle - adverse effects</subject><subject>Arthroplasty, Replacement, Ankle - instrumentation</subject><subject>Arthroplasty, Replacement, Ankle - methods</subject><subject>Female</subject><subject>Follow-Up Studies</subject><subject>Humans</subject><subject>Joint Prosthesis - adverse effects</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Prosthesis Design</subject><subject>Retrospective Studies</subject><subject>Treatment Outcome</subject><subject>Weight-Bearing</subject><issn>1071-1007</issn><issn>1944-7876</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1UDtPwzAQthCIlsLOhDwyELDrxE7GUFFAKmLgsTBEdnwpKU5c7ATRf4-rlg5ILHen-x66-xA6peSSUiGuKBGUklBYQgXJ4j00pFkcRyIVfD_MAYnW-AAdeb8ghApGs0M0GMdBwBM-RG85nti2c9YY0BdhbpbSya7-AvzU9XqFbYUlntbfoKNrkK5u5_gVnO89frCqNrDb5u2HAZy77t3ZpZG-Wx2jg0oaDyfbPkIv05vnyV00e7y9n-SzqGRMdFEGnHLFlBBc83ECPNW6rASVsUghHccyiUsuS6mYKLNMgdZVOF6oqpQsVWnFRuh847t09rMH3xVN7UswRrZge1_QOGMpIQlhgUo21NJZ7x1UxdLVjXSrgpJiHWnxN9IgOdu696oBvRP8ZhgI0Ybg5RyKhe1dG7793_AHwFl9-w</recordid><startdate>201402</startdate><enddate>201402</enddate><creator>Gaudot, Fabrice</creator><creator>Colombier, Jean-Alain</creator><creator>Bonnin, Michel</creator><creator>Judet, Thierry</creator><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201402</creationdate><title>A Controlled, Comparative Study of a Fixed-Bearing Versus Mobile-Bearing Ankle Arthroplasty</title><author>Gaudot, Fabrice ; Colombier, Jean-Alain ; Bonnin, Michel ; Judet, Thierry</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c337t-9e616b3b776d625e68ddcf71a478e824a54c6acab37c99beddf5167bfca38b8f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Ankle Joint - surgery</topic><topic>Arthroplasty, Replacement, Ankle - adverse effects</topic><topic>Arthroplasty, Replacement, Ankle - instrumentation</topic><topic>Arthroplasty, Replacement, Ankle - methods</topic><topic>Female</topic><topic>Follow-Up Studies</topic><topic>Humans</topic><topic>Joint Prosthesis - adverse effects</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Prosthesis Design</topic><topic>Retrospective Studies</topic><topic>Treatment Outcome</topic><topic>Weight-Bearing</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gaudot, Fabrice</creatorcontrib><creatorcontrib>Colombier, Jean-Alain</creatorcontrib><creatorcontrib>Bonnin, Michel</creatorcontrib><creatorcontrib>Judet, Thierry</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Foot &amp; ankle international</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gaudot, Fabrice</au><au>Colombier, Jean-Alain</au><au>Bonnin, Michel</au><au>Judet, Thierry</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Controlled, Comparative Study of a Fixed-Bearing Versus Mobile-Bearing Ankle Arthroplasty</atitle><jtitle>Foot &amp; ankle international</jtitle><addtitle>Foot Ankle Int</addtitle><date>2014-02</date><risdate>2014</risdate><volume>35</volume><issue>2</issue><spage>131</spage><epage>140</epage><pages>131-140</pages><issn>1071-1007</issn><eissn>1944-7876</eissn><abstract>Background: Total ankle arthroplasty is available with fixed-bearing (FB) or mobile-bearing (MB) versions, and there is little consensus on the benefits and drawbacks of each type. This study aimed to compare clinical outcomes of statistically paired series of FB and MB versions of the same ankle prosthesis. Methods: The study was a multicenter retrospective comparison between 2 groups: the FB group of 33 consecutive Talaris cases and the MB group of 33 “paired” Salto cases, selected from a database of 313 consecutive cases to statistically match etiology, age, and preoperative American Orthopaedic Foot &amp; Ankle Society (AOFAS) score. All patients were operated upon with the same operative technique and received identical pre- and postoperative clinical and radiographic assessments. The mean follow-up was 24 months for the FB group and 23 months for the MB group. Results: There was no statistical difference between results of the 2 groups in terms of accuracy of positioning, clinical and radiographic mobility, and morbidity. The most recent postoperative AOFAS scores were higher for the FB group than for the MB group (P = .05). Radiolucent lines were observed in 4 FB patients versus 13 MB patients (P = .02). Subchondral cysts were noted in 1 FB patient and in 8 MB patients (P = .01). Conclusion: There was no notable difference in clinical performance of the FB and MB implants with the numbers available. This short-term study demonstrated that FB ankle arthroplasty had results equivalent to, if not better than, MB ankle arthroplasty. Longer follow-up is necessary to determine the success of this new generation of ankle arthroplasty. Level of Evidence: Level III, retrospective case control study.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>24351656</pmid><doi>10.1177/1071100713517094</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1071-1007
ispartof Foot & ankle international, 2014-02, Vol.35 (2), p.131-140
issn 1071-1007
1944-7876
language eng
recordid cdi_proquest_miscellaneous_1493800503
source MEDLINE; SAGE Journals
subjects Adult
Aged
Ankle Joint - surgery
Arthroplasty, Replacement, Ankle - adverse effects
Arthroplasty, Replacement, Ankle - instrumentation
Arthroplasty, Replacement, Ankle - methods
Female
Follow-Up Studies
Humans
Joint Prosthesis - adverse effects
Male
Middle Aged
Prosthesis Design
Retrospective Studies
Treatment Outcome
Weight-Bearing
title A Controlled, Comparative Study of a Fixed-Bearing Versus Mobile-Bearing Ankle Arthroplasty
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T06%3A58%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Controlled,%20Comparative%20Study%20of%20a%20Fixed-Bearing%20Versus%20Mobile-Bearing%20Ankle%20Arthroplasty&rft.jtitle=Foot%20&%20ankle%20international&rft.au=Gaudot,%20Fabrice&rft.date=2014-02&rft.volume=35&rft.issue=2&rft.spage=131&rft.epage=140&rft.pages=131-140&rft.issn=1071-1007&rft.eissn=1944-7876&rft_id=info:doi/10.1177/1071100713517094&rft_dat=%3Cproquest_cross%3E1493800503%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1493800503&rft_id=info:pmid/24351656&rft_sage_id=10.1177_1071100713517094&rfr_iscdi=true