Fabrication of a highly sensitive disposable immunosensor based on indium tin oxide substrates for cancer biomarker detection

Anti-HER-3 antibody was used for the first time in a disposable immunosensor based on indium tin oxide (ITO) substrate for HER-3 quantification. Anti-HER-3 was immobilized onto ITO substrate by 3-aminopropyl)triethoxysilane (APTES) and glutaraldehyde. This highly sensitive immunosensor was capable o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical biochemistry 2014-02, Vol.446, p.9-18
Hauptverfasser: Canbaz, Mehmet Çetin, Sezgintürk, Mustafa Kemal
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 18
container_issue
container_start_page 9
container_title Analytical biochemistry
container_volume 446
creator Canbaz, Mehmet Çetin
Sezgintürk, Mustafa Kemal
description Anti-HER-3 antibody was used for the first time in a disposable immunosensor based on indium tin oxide (ITO) substrate for HER-3 quantification. Anti-HER-3 was immobilized onto ITO substrate by 3-aminopropyl)triethoxysilane (APTES) and glutaraldehyde. This highly sensitive immunosensor was capable of detecting concentrations of HER-3 down to the femtogram/ml level by investigating changes in the charge transfer resistance (Rct) using electrochemical impedance spectroscopy (EIS). Construction of ITO layers was carefully investigated using a broad range of techniques such as voltammetry, EIS, atomic force microscopy (AFM), and scanning electron microscopy (SEM). Meanwhile, in an immunosensor system, the “single frequency impedance” technique was first used for characterization of interaction between HER-3 and anti-HER-3. Eventually, the proposed ITO-based immunosensor was applied to artificial serum samples spiked with HER-3.
doi_str_mv 10.1016/j.ab.2013.10.014
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1490746974</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003269713004946</els_id><sourcerecordid>1490746974</sourcerecordid><originalsourceid>FETCH-LOGICAL-c416t-19a5cdd907264e9c7d5bed770c735c05e7ea00cf532333c73b4de41f0f7a27653</originalsourceid><addsrcrecordid>eNp1kE1P3DAQhi1EBVvg3lPlI5dsx7ETN71VCGglJC70bPljUmabxFs7QeXAf8fR0t56sj1-5h37YeyDgK0A0X7aba3b1iBkOW5BqCO2EdC1FUjojtkGAGRVt50-Ze9z3gEIoZr2hJ3WSigB-vOGvdxYl8jbmeLEY88tf6Sfj8MzzzhlmukJeaC8j9m6ATmN4zLF9Som7mzGwEsbTYGWkc9UEv5QQJ4Xl-dkZ8y8L6C3k8fCUxxt-lV2AWf068Rz9q63Q8aLt_WM_bi5frj6Vt3d336_-npXeSXauRKdbXwIHei6Vdh5HRqHQWvwWjYeGtRoAXzfyFpKWYpOBVSih17bWreNPGOXh9x9ir8XzLMZKXscBjthXLIRqmSrIkoVFA6oTzHnhL3ZJyrvfjYCzCrd7Ix1ZpW-Vor00vLxLX1xI4Z_DX8tF-DLAcDyxyfCZLInLFICpSLChEj_T38FQdSTjA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1490746974</pqid></control><display><type>article</type><title>Fabrication of a highly sensitive disposable immunosensor based on indium tin oxide substrates for cancer biomarker detection</title><source>Elsevier ScienceDirect Journals Complete - AutoHoldings</source><source>MEDLINE</source><creator>Canbaz, Mehmet Çetin ; Sezgintürk, Mustafa Kemal</creator><creatorcontrib>Canbaz, Mehmet Çetin ; Sezgintürk, Mustafa Kemal</creatorcontrib><description>Anti-HER-3 antibody was used for the first time in a disposable immunosensor based on indium tin oxide (ITO) substrate for HER-3 quantification. Anti-HER-3 was immobilized onto ITO substrate by 3-aminopropyl)triethoxysilane (APTES) and glutaraldehyde. This highly sensitive immunosensor was capable of detecting concentrations of HER-3 down to the femtogram/ml level by investigating changes in the charge transfer resistance (Rct) using electrochemical impedance spectroscopy (EIS). Construction of ITO layers was carefully investigated using a broad range of techniques such as voltammetry, EIS, atomic force microscopy (AFM), and scanning electron microscopy (SEM). Meanwhile, in an immunosensor system, the “single frequency impedance” technique was first used for characterization of interaction between HER-3 and anti-HER-3. Eventually, the proposed ITO-based immunosensor was applied to artificial serum samples spiked with HER-3.</description><identifier>ISSN: 0003-2697</identifier><identifier>EISSN: 1096-0309</identifier><identifier>DOI: 10.1016/j.ab.2013.10.014</identifier><identifier>PMID: 24141078</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Animals ; Antibodies, Immobilized - immunology ; Biomarkers, Tumor - analysis ; Biomarkers, Tumor - chemistry ; Biomarkers, Tumor - immunology ; Biosensing Techniques - instrumentation ; Biosensor ; Cancer biomarkers ; Disposable Equipment ; Electrodes ; HER-3 ; Immunoassay - instrumentation ; ITO ; Receptor, ErbB-3 - analysis ; Receptor, ErbB-3 - chemistry ; Receptor, ErbB-3 - immunology ; Single frequency impedance ; Surface Properties ; Tin Compounds - chemistry</subject><ispartof>Analytical biochemistry, 2014-02, Vol.446, p.9-18</ispartof><rights>2013 Elsevier Inc.</rights><rights>Copyright © 2013 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c416t-19a5cdd907264e9c7d5bed770c735c05e7ea00cf532333c73b4de41f0f7a27653</citedby><cites>FETCH-LOGICAL-c416t-19a5cdd907264e9c7d5bed770c735c05e7ea00cf532333c73b4de41f0f7a27653</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.ab.2013.10.014$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,778,782,3539,27913,27914,45984</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24141078$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Canbaz, Mehmet Çetin</creatorcontrib><creatorcontrib>Sezgintürk, Mustafa Kemal</creatorcontrib><title>Fabrication of a highly sensitive disposable immunosensor based on indium tin oxide substrates for cancer biomarker detection</title><title>Analytical biochemistry</title><addtitle>Anal Biochem</addtitle><description>Anti-HER-3 antibody was used for the first time in a disposable immunosensor based on indium tin oxide (ITO) substrate for HER-3 quantification. Anti-HER-3 was immobilized onto ITO substrate by 3-aminopropyl)triethoxysilane (APTES) and glutaraldehyde. This highly sensitive immunosensor was capable of detecting concentrations of HER-3 down to the femtogram/ml level by investigating changes in the charge transfer resistance (Rct) using electrochemical impedance spectroscopy (EIS). Construction of ITO layers was carefully investigated using a broad range of techniques such as voltammetry, EIS, atomic force microscopy (AFM), and scanning electron microscopy (SEM). Meanwhile, in an immunosensor system, the “single frequency impedance” technique was first used for characterization of interaction between HER-3 and anti-HER-3. Eventually, the proposed ITO-based immunosensor was applied to artificial serum samples spiked with HER-3.</description><subject>Animals</subject><subject>Antibodies, Immobilized - immunology</subject><subject>Biomarkers, Tumor - analysis</subject><subject>Biomarkers, Tumor - chemistry</subject><subject>Biomarkers, Tumor - immunology</subject><subject>Biosensing Techniques - instrumentation</subject><subject>Biosensor</subject><subject>Cancer biomarkers</subject><subject>Disposable Equipment</subject><subject>Electrodes</subject><subject>HER-3</subject><subject>Immunoassay - instrumentation</subject><subject>ITO</subject><subject>Receptor, ErbB-3 - analysis</subject><subject>Receptor, ErbB-3 - chemistry</subject><subject>Receptor, ErbB-3 - immunology</subject><subject>Single frequency impedance</subject><subject>Surface Properties</subject><subject>Tin Compounds - chemistry</subject><issn>0003-2697</issn><issn>1096-0309</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kE1P3DAQhi1EBVvg3lPlI5dsx7ETN71VCGglJC70bPljUmabxFs7QeXAf8fR0t56sj1-5h37YeyDgK0A0X7aba3b1iBkOW5BqCO2EdC1FUjojtkGAGRVt50-Ze9z3gEIoZr2hJ3WSigB-vOGvdxYl8jbmeLEY88tf6Sfj8MzzzhlmukJeaC8j9m6ATmN4zLF9Som7mzGwEsbTYGWkc9UEv5QQJ4Xl-dkZ8y8L6C3k8fCUxxt-lV2AWf068Rz9q63Q8aLt_WM_bi5frj6Vt3d336_-npXeSXauRKdbXwIHei6Vdh5HRqHQWvwWjYeGtRoAXzfyFpKWYpOBVSih17bWreNPGOXh9x9ir8XzLMZKXscBjthXLIRqmSrIkoVFA6oTzHnhL3ZJyrvfjYCzCrd7Ix1ZpW-Vor00vLxLX1xI4Z_DX8tF-DLAcDyxyfCZLInLFICpSLChEj_T38FQdSTjA</recordid><startdate>20140201</startdate><enddate>20140201</enddate><creator>Canbaz, Mehmet Çetin</creator><creator>Sezgintürk, Mustafa Kemal</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20140201</creationdate><title>Fabrication of a highly sensitive disposable immunosensor based on indium tin oxide substrates for cancer biomarker detection</title><author>Canbaz, Mehmet Çetin ; Sezgintürk, Mustafa Kemal</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c416t-19a5cdd907264e9c7d5bed770c735c05e7ea00cf532333c73b4de41f0f7a27653</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Animals</topic><topic>Antibodies, Immobilized - immunology</topic><topic>Biomarkers, Tumor - analysis</topic><topic>Biomarkers, Tumor - chemistry</topic><topic>Biomarkers, Tumor - immunology</topic><topic>Biosensing Techniques - instrumentation</topic><topic>Biosensor</topic><topic>Cancer biomarkers</topic><topic>Disposable Equipment</topic><topic>Electrodes</topic><topic>HER-3</topic><topic>Immunoassay - instrumentation</topic><topic>ITO</topic><topic>Receptor, ErbB-3 - analysis</topic><topic>Receptor, ErbB-3 - chemistry</topic><topic>Receptor, ErbB-3 - immunology</topic><topic>Single frequency impedance</topic><topic>Surface Properties</topic><topic>Tin Compounds - chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Canbaz, Mehmet Çetin</creatorcontrib><creatorcontrib>Sezgintürk, Mustafa Kemal</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical biochemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Canbaz, Mehmet Çetin</au><au>Sezgintürk, Mustafa Kemal</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fabrication of a highly sensitive disposable immunosensor based on indium tin oxide substrates for cancer biomarker detection</atitle><jtitle>Analytical biochemistry</jtitle><addtitle>Anal Biochem</addtitle><date>2014-02-01</date><risdate>2014</risdate><volume>446</volume><spage>9</spage><epage>18</epage><pages>9-18</pages><issn>0003-2697</issn><eissn>1096-0309</eissn><abstract>Anti-HER-3 antibody was used for the first time in a disposable immunosensor based on indium tin oxide (ITO) substrate for HER-3 quantification. Anti-HER-3 was immobilized onto ITO substrate by 3-aminopropyl)triethoxysilane (APTES) and glutaraldehyde. This highly sensitive immunosensor was capable of detecting concentrations of HER-3 down to the femtogram/ml level by investigating changes in the charge transfer resistance (Rct) using electrochemical impedance spectroscopy (EIS). Construction of ITO layers was carefully investigated using a broad range of techniques such as voltammetry, EIS, atomic force microscopy (AFM), and scanning electron microscopy (SEM). Meanwhile, in an immunosensor system, the “single frequency impedance” technique was first used for characterization of interaction between HER-3 and anti-HER-3. Eventually, the proposed ITO-based immunosensor was applied to artificial serum samples spiked with HER-3.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>24141078</pmid><doi>10.1016/j.ab.2013.10.014</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2697
ispartof Analytical biochemistry, 2014-02, Vol.446, p.9-18
issn 0003-2697
1096-0309
language eng
recordid cdi_proquest_miscellaneous_1490746974
source Elsevier ScienceDirect Journals Complete - AutoHoldings; MEDLINE
subjects Animals
Antibodies, Immobilized - immunology
Biomarkers, Tumor - analysis
Biomarkers, Tumor - chemistry
Biomarkers, Tumor - immunology
Biosensing Techniques - instrumentation
Biosensor
Cancer biomarkers
Disposable Equipment
Electrodes
HER-3
Immunoassay - instrumentation
ITO
Receptor, ErbB-3 - analysis
Receptor, ErbB-3 - chemistry
Receptor, ErbB-3 - immunology
Single frequency impedance
Surface Properties
Tin Compounds - chemistry
title Fabrication of a highly sensitive disposable immunosensor based on indium tin oxide substrates for cancer biomarker detection
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T09%3A06%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fabrication%20of%20a%20highly%20sensitive%20disposable%20immunosensor%20based%20on%20indium%20tin%20oxide%20substrates%20for%20cancer%20biomarker%20detection&rft.jtitle=Analytical%20biochemistry&rft.au=Canbaz,%20Mehmet%20%C3%87etin&rft.date=2014-02-01&rft.volume=446&rft.spage=9&rft.epage=18&rft.pages=9-18&rft.issn=0003-2697&rft.eissn=1096-0309&rft_id=info:doi/10.1016/j.ab.2013.10.014&rft_dat=%3Cproquest_cross%3E1490746974%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1490746974&rft_id=info:pmid/24141078&rft_els_id=S0003269713004946&rfr_iscdi=true