Radon activity concentration—a Euromet and BIPM supplementary comparison
For the first time, a comparison of radon activity concentration in air has been performed within the scope of Euromet. In the project 657, ‘Comparison of calibration facilities for the radon activity concentration,’ 12 participants from 9 countries compared different radon reference atmospheres at...
Gespeichert in:
Veröffentlicht in: | Applied Radiation and Isotopes 2006-10, Vol.64 (10), p.1102-1107 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1107 |
---|---|
container_issue | 10 |
container_start_page | 1102 |
container_title | Applied Radiation and Isotopes |
container_volume | 64 |
creator | Röttger, A. Honig, A. Schmidt, V. Buchröder, H. Rox, A. Butterweck, G. Schuler, Ch Maringer, F.J. Jachs, P. Edelmaier, R. Michielsen, N. Howarth, C.B. H. Miles, J.C. Vargas, A. Ortega, X. Burian, I. Turtiainen, T. Hagberg, N. |
description | For the first time, a comparison of radon activity concentration in air has been performed within the scope of Euromet. In the project 657, ‘Comparison of calibration facilities for the radon activity concentration,’ 12 participants from 9 countries compared different radon reference atmospheres at 1, 3 and 10
kBq
m
−3 via a transfer standard. The comparison was listed as BIPM supplementary comparison EUROMET.RI(II)-S1. The results of most participants are correlated due to common traceability to one single radon gas standard producer. This makes a careful correlation analysis necessary to achieve an appropriate comparison reference value. The results of the comparison as well as the complex analysis of the correlated set of data is presented and discussed. |
doi_str_mv | 10.1016/j.apradiso.2006.02.086 |
format | Article |
fullrecord | <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_proquest_miscellaneous_14792800</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0969804306000431</els_id><sourcerecordid>14792800</sourcerecordid><originalsourceid>FETCH-LOGICAL-c497t-8e52cb1615d143ca00e516b418d707b2a279421277f9eadf91cd4b83d82319d23</originalsourceid><addsrcrecordid>eNqFkM9q3DAQh0VpaDbbvsLiU6EHOzOy15JuTUOaP2xIKMlZyJKWarEtV7IXestD5AnzJNGy2-aY08Dw_X4zfIQsEAoErE83hRqCMi76ggLUBdACeP2BzJAzmgsO8JHMQNQi51CVx-Qkxg0AVFzQT-QY6yUHimxGbn4p4_tM6dFt3fg3077Xth-DGp3vX56eVXYxBd_ZMVO9yX5c399mcRqG1naJUmEX6AYV0h_9Z3K0Vm20Xw5zTh5_XjycX-Wru8vr87NVrivBxpzbJdUN1rg0WJVaAdgl1k2F3DBgDVWUiYoiZWwtrDJrgdpUDS8NpyUKQ8s5-bbv_a1aOQTXpTekV05ena3kbgclUIHItpjYr3t2CP7PZOMoOxe1bVvVWz9FiRUTNMlKYL0HdfAxBrv-34wgd8blRv4zLnfGJVCZjKfg4nBhajpr3mIHxQn4vgdscrJ1NsionU2WjQtWj9J4996NV-ARlXk</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>14792800</pqid></control><display><type>article</type><title>Radon activity concentration—a Euromet and BIPM supplementary comparison</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Röttger, A. ; Honig, A. ; Schmidt, V. ; Buchröder, H. ; Rox, A. ; Butterweck, G. ; Schuler, Ch ; Maringer, F.J. ; Jachs, P. ; Edelmaier, R. ; Michielsen, N. ; Howarth, C.B. ; H. Miles, J.C. ; Vargas, A. ; Ortega, X. ; Burian, I. ; Turtiainen, T. ; Hagberg, N.</creator><creatorcontrib>Röttger, A. ; Honig, A. ; Schmidt, V. ; Buchröder, H. ; Rox, A. ; Butterweck, G. ; Schuler, Ch ; Maringer, F.J. ; Jachs, P. ; Edelmaier, R. ; Michielsen, N. ; Howarth, C.B. ; H. Miles, J.C. ; Vargas, A. ; Ortega, X. ; Burian, I. ; Turtiainen, T. ; Hagberg, N.</creatorcontrib><description>For the first time, a comparison of radon activity concentration in air has been performed within the scope of Euromet. In the project 657, ‘Comparison of calibration facilities for the radon activity concentration,’ 12 participants from 9 countries compared different radon reference atmospheres at 1, 3 and 10
kBq
m
−3 via a transfer standard. The comparison was listed as BIPM supplementary comparison EUROMET.RI(II)-S1. The results of most participants are correlated due to common traceability to one single radon gas standard producer. This makes a careful correlation analysis necessary to achieve an appropriate comparison reference value. The results of the comparison as well as the complex analysis of the correlated set of data is presented and discussed.</description><identifier>ISSN: 0969-8043</identifier><identifier>EISSN: 1872-9800</identifier><identifier>DOI: 10.1016/j.apradiso.2006.02.086</identifier><identifier>PMID: 16580217</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Air Pollutants, Radioactive - analysis ; Air Pollutants, Radioactive - standards ; Calibration - standards ; Comparison ; Europe ; Guidelines as Topic ; International Cooperation ; Life Sciences ; Radiation Dosage ; Radiation Monitoring - methods ; Radiation Monitoring - standards ; Radon - analysis ; Radon - standards ; Radon activity concentrations ; Reference Standards ; Reproducibility of Results ; Sensitivity and Specificity</subject><ispartof>Applied Radiation and Isotopes, 2006-10, Vol.64 (10), p.1102-1107</ispartof><rights>2006 Elsevier Ltd</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c497t-8e52cb1615d143ca00e516b418d707b2a279421277f9eadf91cd4b83d82319d23</citedby><cites>FETCH-LOGICAL-c497t-8e52cb1615d143ca00e516b418d707b2a279421277f9eadf91cd4b83d82319d23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.apradiso.2006.02.086$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,777,781,882,3537,27905,27906,45976</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16580217$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://hal.science/hal-03029117$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Röttger, A.</creatorcontrib><creatorcontrib>Honig, A.</creatorcontrib><creatorcontrib>Schmidt, V.</creatorcontrib><creatorcontrib>Buchröder, H.</creatorcontrib><creatorcontrib>Rox, A.</creatorcontrib><creatorcontrib>Butterweck, G.</creatorcontrib><creatorcontrib>Schuler, Ch</creatorcontrib><creatorcontrib>Maringer, F.J.</creatorcontrib><creatorcontrib>Jachs, P.</creatorcontrib><creatorcontrib>Edelmaier, R.</creatorcontrib><creatorcontrib>Michielsen, N.</creatorcontrib><creatorcontrib>Howarth, C.B.</creatorcontrib><creatorcontrib>H. Miles, J.C.</creatorcontrib><creatorcontrib>Vargas, A.</creatorcontrib><creatorcontrib>Ortega, X.</creatorcontrib><creatorcontrib>Burian, I.</creatorcontrib><creatorcontrib>Turtiainen, T.</creatorcontrib><creatorcontrib>Hagberg, N.</creatorcontrib><title>Radon activity concentration—a Euromet and BIPM supplementary comparison</title><title>Applied Radiation and Isotopes</title><addtitle>Appl Radiat Isot</addtitle><description>For the first time, a comparison of radon activity concentration in air has been performed within the scope of Euromet. In the project 657, ‘Comparison of calibration facilities for the radon activity concentration,’ 12 participants from 9 countries compared different radon reference atmospheres at 1, 3 and 10
kBq
m
−3 via a transfer standard. The comparison was listed as BIPM supplementary comparison EUROMET.RI(II)-S1. The results of most participants are correlated due to common traceability to one single radon gas standard producer. This makes a careful correlation analysis necessary to achieve an appropriate comparison reference value. The results of the comparison as well as the complex analysis of the correlated set of data is presented and discussed.</description><subject>Air Pollutants, Radioactive - analysis</subject><subject>Air Pollutants, Radioactive - standards</subject><subject>Calibration - standards</subject><subject>Comparison</subject><subject>Europe</subject><subject>Guidelines as Topic</subject><subject>International Cooperation</subject><subject>Life Sciences</subject><subject>Radiation Dosage</subject><subject>Radiation Monitoring - methods</subject><subject>Radiation Monitoring - standards</subject><subject>Radon - analysis</subject><subject>Radon - standards</subject><subject>Radon activity concentrations</subject><subject>Reference Standards</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><issn>0969-8043</issn><issn>1872-9800</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkM9q3DAQh0VpaDbbvsLiU6EHOzOy15JuTUOaP2xIKMlZyJKWarEtV7IXestD5AnzJNGy2-aY08Dw_X4zfIQsEAoErE83hRqCMi76ggLUBdACeP2BzJAzmgsO8JHMQNQi51CVx-Qkxg0AVFzQT-QY6yUHimxGbn4p4_tM6dFt3fg3077Xth-DGp3vX56eVXYxBd_ZMVO9yX5c399mcRqG1naJUmEX6AYV0h_9Z3K0Vm20Xw5zTh5_XjycX-Wru8vr87NVrivBxpzbJdUN1rg0WJVaAdgl1k2F3DBgDVWUiYoiZWwtrDJrgdpUDS8NpyUKQ8s5-bbv_a1aOQTXpTekV05ena3kbgclUIHItpjYr3t2CP7PZOMoOxe1bVvVWz9FiRUTNMlKYL0HdfAxBrv-34wgd8blRv4zLnfGJVCZjKfg4nBhajpr3mIHxQn4vgdscrJ1NsionU2WjQtWj9J4996NV-ARlXk</recordid><startdate>20061001</startdate><enddate>20061001</enddate><creator>Röttger, A.</creator><creator>Honig, A.</creator><creator>Schmidt, V.</creator><creator>Buchröder, H.</creator><creator>Rox, A.</creator><creator>Butterweck, G.</creator><creator>Schuler, Ch</creator><creator>Maringer, F.J.</creator><creator>Jachs, P.</creator><creator>Edelmaier, R.</creator><creator>Michielsen, N.</creator><creator>Howarth, C.B.</creator><creator>H. Miles, J.C.</creator><creator>Vargas, A.</creator><creator>Ortega, X.</creator><creator>Burian, I.</creator><creator>Turtiainen, T.</creator><creator>Hagberg, N.</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope><scope>1XC</scope></search><sort><creationdate>20061001</creationdate><title>Radon activity concentration—a Euromet and BIPM supplementary comparison</title><author>Röttger, A. ; Honig, A. ; Schmidt, V. ; Buchröder, H. ; Rox, A. ; Butterweck, G. ; Schuler, Ch ; Maringer, F.J. ; Jachs, P. ; Edelmaier, R. ; Michielsen, N. ; Howarth, C.B. ; H. Miles, J.C. ; Vargas, A. ; Ortega, X. ; Burian, I. ; Turtiainen, T. ; Hagberg, N.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c497t-8e52cb1615d143ca00e516b418d707b2a279421277f9eadf91cd4b83d82319d23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Air Pollutants, Radioactive - analysis</topic><topic>Air Pollutants, Radioactive - standards</topic><topic>Calibration - standards</topic><topic>Comparison</topic><topic>Europe</topic><topic>Guidelines as Topic</topic><topic>International Cooperation</topic><topic>Life Sciences</topic><topic>Radiation Dosage</topic><topic>Radiation Monitoring - methods</topic><topic>Radiation Monitoring - standards</topic><topic>Radon - analysis</topic><topic>Radon - standards</topic><topic>Radon activity concentrations</topic><topic>Reference Standards</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Röttger, A.</creatorcontrib><creatorcontrib>Honig, A.</creatorcontrib><creatorcontrib>Schmidt, V.</creatorcontrib><creatorcontrib>Buchröder, H.</creatorcontrib><creatorcontrib>Rox, A.</creatorcontrib><creatorcontrib>Butterweck, G.</creatorcontrib><creatorcontrib>Schuler, Ch</creatorcontrib><creatorcontrib>Maringer, F.J.</creatorcontrib><creatorcontrib>Jachs, P.</creatorcontrib><creatorcontrib>Edelmaier, R.</creatorcontrib><creatorcontrib>Michielsen, N.</creatorcontrib><creatorcontrib>Howarth, C.B.</creatorcontrib><creatorcontrib>H. Miles, J.C.</creatorcontrib><creatorcontrib>Vargas, A.</creatorcontrib><creatorcontrib>Ortega, X.</creatorcontrib><creatorcontrib>Burian, I.</creatorcontrib><creatorcontrib>Turtiainen, T.</creatorcontrib><creatorcontrib>Hagberg, N.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><collection>Hyper Article en Ligne (HAL)</collection><jtitle>Applied Radiation and Isotopes</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Röttger, A.</au><au>Honig, A.</au><au>Schmidt, V.</au><au>Buchröder, H.</au><au>Rox, A.</au><au>Butterweck, G.</au><au>Schuler, Ch</au><au>Maringer, F.J.</au><au>Jachs, P.</au><au>Edelmaier, R.</au><au>Michielsen, N.</au><au>Howarth, C.B.</au><au>H. Miles, J.C.</au><au>Vargas, A.</au><au>Ortega, X.</au><au>Burian, I.</au><au>Turtiainen, T.</au><au>Hagberg, N.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Radon activity concentration—a Euromet and BIPM supplementary comparison</atitle><jtitle>Applied Radiation and Isotopes</jtitle><addtitle>Appl Radiat Isot</addtitle><date>2006-10-01</date><risdate>2006</risdate><volume>64</volume><issue>10</issue><spage>1102</spage><epage>1107</epage><pages>1102-1107</pages><issn>0969-8043</issn><eissn>1872-9800</eissn><abstract>For the first time, a comparison of radon activity concentration in air has been performed within the scope of Euromet. In the project 657, ‘Comparison of calibration facilities for the radon activity concentration,’ 12 participants from 9 countries compared different radon reference atmospheres at 1, 3 and 10
kBq
m
−3 via a transfer standard. The comparison was listed as BIPM supplementary comparison EUROMET.RI(II)-S1. The results of most participants are correlated due to common traceability to one single radon gas standard producer. This makes a careful correlation analysis necessary to achieve an appropriate comparison reference value. The results of the comparison as well as the complex analysis of the correlated set of data is presented and discussed.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>16580217</pmid><doi>10.1016/j.apradiso.2006.02.086</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0969-8043 |
ispartof | Applied Radiation and Isotopes, 2006-10, Vol.64 (10), p.1102-1107 |
issn | 0969-8043 1872-9800 |
language | eng |
recordid | cdi_proquest_miscellaneous_14792800 |
source | MEDLINE; Elsevier ScienceDirect Journals |
subjects | Air Pollutants, Radioactive - analysis Air Pollutants, Radioactive - standards Calibration - standards Comparison Europe Guidelines as Topic International Cooperation Life Sciences Radiation Dosage Radiation Monitoring - methods Radiation Monitoring - standards Radon - analysis Radon - standards Radon activity concentrations Reference Standards Reproducibility of Results Sensitivity and Specificity |
title | Radon activity concentration—a Euromet and BIPM supplementary comparison |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T15%3A15%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Radon%20activity%20concentration%E2%80%94a%20Euromet%20and%20BIPM%20supplementary%20comparison&rft.jtitle=Applied%20Radiation%20and%20Isotopes&rft.au=R%C3%B6ttger,%20A.&rft.date=2006-10-01&rft.volume=64&rft.issue=10&rft.spage=1102&rft.epage=1107&rft.pages=1102-1107&rft.issn=0969-8043&rft.eissn=1872-9800&rft_id=info:doi/10.1016/j.apradiso.2006.02.086&rft_dat=%3Cproquest_hal_p%3E14792800%3C/proquest_hal_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=14792800&rft_id=info:pmid/16580217&rft_els_id=S0969804306000431&rfr_iscdi=true |