Experimental Investigations of the Shear Capacity of Nails in a Row

Tests of the capacity of shear connections consisting of nails in a row placed at distances 7, 10 and 14d, "d" being the cross-sectional dimension of the nail, versus single nail capacities, were executed. The performed tests do support the connotation that no reduction should be required...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Open journal of civil engineering 2013-08, Vol.3 (3), p.173-181
Hauptverfasser: Sørensen, Christian O., Nymark, Ruth-Marie, Baastad, Lars
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 181
container_issue 3
container_start_page 173
container_title Open journal of civil engineering
container_volume 3
creator Sørensen, Christian O.
Nymark, Ruth-Marie
Baastad, Lars
description Tests of the capacity of shear connections consisting of nails in a row placed at distances 7, 10 and 14d, "d" being the cross-sectional dimension of the nail, versus single nail capacities, were executed. The performed tests do support the connotation that no reduction should be required for nails of diameter 2.8 mm or less in a row, provided that nails are spaced sufficiently far apart for wood cracking not to occur. At the ultimate capacity of the joint, all such thin nails in a row will be yielding, having developed plastic hinges, i.e. each single nail will have developed its ultimate capacity. Hence, the ultimate capacity of the connection will be each nail's capacity times the number of nails in the row. The force pr. nail increases subsequent to the development of a plastic hinge. This is likely due to the axial pullout-force, i.e. the ultimate capacity of a shear connection is higher than the force required for developing plastic hinges in the nails. This additional capacity-reserve may also partly be attributed to the rotational resistance of nails. The number of nails in a row should make insignificant difference in the pr. nail capacity, as long as no wood cracking takes place. Thus, applying elastic theory to nails in a row does not seem relevant. This is in contrast to bolt-connections.
doi_str_mv 10.4236/ojce.2013.33021
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1475556035</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1475556035</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1141-2c7c989977f4d9d7367c790cb1b2ad81e5524738587530ae76052d7bba2b30ab3</originalsourceid><addsrcrecordid>eNo9kEtPwzAQhC0EElXpmauPXJJ6_UyOKCpQqQKJx9lyHIe6SuMQp0D_PQlF7GV2V6PV7IfQNZCUUyaXYWddSgmwlDFC4QzNKEieMFD0_L-X_BItYtyRsSQBkeUzVKy-O9f7vWsH0-B1--ni4N_N4EMbcajxsHX4ZetMjwvTGeuH47R9NL6J2LfY4OfwdYUuatNEt_jTOXq7W70WD8nm6X5d3G4SC8AhoVbZPMtzpWpe5ZViUlmVE1tCSU2VgROCcsUykSnBiHFKEkErVZaGluNcsjm6Od3t-vBxGIPqvY_WNY1pXThEDVwJISRhYrQuT1bbhxh7V-tufNL0Rw1ET8T0RExPxPQvMfYDr0ZdCA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1475556035</pqid></control><display><type>article</type><title>Experimental Investigations of the Shear Capacity of Nails in a Row</title><source>EZB Electronic Journals Library</source><creator>Sørensen, Christian O. ; Nymark, Ruth-Marie ; Baastad, Lars</creator><creatorcontrib>Sørensen, Christian O. ; Nymark, Ruth-Marie ; Baastad, Lars</creatorcontrib><description>Tests of the capacity of shear connections consisting of nails in a row placed at distances 7, 10 and 14d, "d" being the cross-sectional dimension of the nail, versus single nail capacities, were executed. The performed tests do support the connotation that no reduction should be required for nails of diameter 2.8 mm or less in a row, provided that nails are spaced sufficiently far apart for wood cracking not to occur. At the ultimate capacity of the joint, all such thin nails in a row will be yielding, having developed plastic hinges, i.e. each single nail will have developed its ultimate capacity. Hence, the ultimate capacity of the connection will be each nail's capacity times the number of nails in the row. The force pr. nail increases subsequent to the development of a plastic hinge. This is likely due to the axial pullout-force, i.e. the ultimate capacity of a shear connection is higher than the force required for developing plastic hinges in the nails. This additional capacity-reserve may also partly be attributed to the rotational resistance of nails. The number of nails in a row should make insignificant difference in the pr. nail capacity, as long as no wood cracking takes place. Thus, applying elastic theory to nails in a row does not seem relevant. This is in contrast to bolt-connections.</description><identifier>ISSN: 2164-3164</identifier><identifier>EISSN: 2164-3172</identifier><identifier>DOI: 10.4236/ojce.2013.33021</identifier><language>eng</language><subject>Bolting ; Bolts ; Fracture mechanics ; Hinges ; Joints ; Nails ; Shear ; Wood</subject><ispartof>Open journal of civil engineering, 2013-08, Vol.3 (3), p.173-181</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1141-2c7c989977f4d9d7367c790cb1b2ad81e5524738587530ae76052d7bba2b30ab3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Sørensen, Christian O.</creatorcontrib><creatorcontrib>Nymark, Ruth-Marie</creatorcontrib><creatorcontrib>Baastad, Lars</creatorcontrib><title>Experimental Investigations of the Shear Capacity of Nails in a Row</title><title>Open journal of civil engineering</title><description>Tests of the capacity of shear connections consisting of nails in a row placed at distances 7, 10 and 14d, "d" being the cross-sectional dimension of the nail, versus single nail capacities, were executed. The performed tests do support the connotation that no reduction should be required for nails of diameter 2.8 mm or less in a row, provided that nails are spaced sufficiently far apart for wood cracking not to occur. At the ultimate capacity of the joint, all such thin nails in a row will be yielding, having developed plastic hinges, i.e. each single nail will have developed its ultimate capacity. Hence, the ultimate capacity of the connection will be each nail's capacity times the number of nails in the row. The force pr. nail increases subsequent to the development of a plastic hinge. This is likely due to the axial pullout-force, i.e. the ultimate capacity of a shear connection is higher than the force required for developing plastic hinges in the nails. This additional capacity-reserve may also partly be attributed to the rotational resistance of nails. The number of nails in a row should make insignificant difference in the pr. nail capacity, as long as no wood cracking takes place. Thus, applying elastic theory to nails in a row does not seem relevant. This is in contrast to bolt-connections.</description><subject>Bolting</subject><subject>Bolts</subject><subject>Fracture mechanics</subject><subject>Hinges</subject><subject>Joints</subject><subject>Nails</subject><subject>Shear</subject><subject>Wood</subject><issn>2164-3164</issn><issn>2164-3172</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNo9kEtPwzAQhC0EElXpmauPXJJ6_UyOKCpQqQKJx9lyHIe6SuMQp0D_PQlF7GV2V6PV7IfQNZCUUyaXYWddSgmwlDFC4QzNKEieMFD0_L-X_BItYtyRsSQBkeUzVKy-O9f7vWsH0-B1--ni4N_N4EMbcajxsHX4ZetMjwvTGeuH47R9NL6J2LfY4OfwdYUuatNEt_jTOXq7W70WD8nm6X5d3G4SC8AhoVbZPMtzpWpe5ZViUlmVE1tCSU2VgROCcsUykSnBiHFKEkErVZaGluNcsjm6Od3t-vBxGIPqvY_WNY1pXThEDVwJISRhYrQuT1bbhxh7V-tufNL0Rw1ET8T0RExPxPQvMfYDr0ZdCA</recordid><startdate>20130801</startdate><enddate>20130801</enddate><creator>Sørensen, Christian O.</creator><creator>Nymark, Ruth-Marie</creator><creator>Baastad, Lars</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>20130801</creationdate><title>Experimental Investigations of the Shear Capacity of Nails in a Row</title><author>Sørensen, Christian O. ; Nymark, Ruth-Marie ; Baastad, Lars</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1141-2c7c989977f4d9d7367c790cb1b2ad81e5524738587530ae76052d7bba2b30ab3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Bolting</topic><topic>Bolts</topic><topic>Fracture mechanics</topic><topic>Hinges</topic><topic>Joints</topic><topic>Nails</topic><topic>Shear</topic><topic>Wood</topic><toplevel>online_resources</toplevel><creatorcontrib>Sørensen, Christian O.</creatorcontrib><creatorcontrib>Nymark, Ruth-Marie</creatorcontrib><creatorcontrib>Baastad, Lars</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Open journal of civil engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sørensen, Christian O.</au><au>Nymark, Ruth-Marie</au><au>Baastad, Lars</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Experimental Investigations of the Shear Capacity of Nails in a Row</atitle><jtitle>Open journal of civil engineering</jtitle><date>2013-08-01</date><risdate>2013</risdate><volume>3</volume><issue>3</issue><spage>173</spage><epage>181</epage><pages>173-181</pages><issn>2164-3164</issn><eissn>2164-3172</eissn><abstract>Tests of the capacity of shear connections consisting of nails in a row placed at distances 7, 10 and 14d, "d" being the cross-sectional dimension of the nail, versus single nail capacities, were executed. The performed tests do support the connotation that no reduction should be required for nails of diameter 2.8 mm or less in a row, provided that nails are spaced sufficiently far apart for wood cracking not to occur. At the ultimate capacity of the joint, all such thin nails in a row will be yielding, having developed plastic hinges, i.e. each single nail will have developed its ultimate capacity. Hence, the ultimate capacity of the connection will be each nail's capacity times the number of nails in the row. The force pr. nail increases subsequent to the development of a plastic hinge. This is likely due to the axial pullout-force, i.e. the ultimate capacity of a shear connection is higher than the force required for developing plastic hinges in the nails. This additional capacity-reserve may also partly be attributed to the rotational resistance of nails. The number of nails in a row should make insignificant difference in the pr. nail capacity, as long as no wood cracking takes place. Thus, applying elastic theory to nails in a row does not seem relevant. This is in contrast to bolt-connections.</abstract><doi>10.4236/ojce.2013.33021</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2164-3164
ispartof Open journal of civil engineering, 2013-08, Vol.3 (3), p.173-181
issn 2164-3164
2164-3172
language eng
recordid cdi_proquest_miscellaneous_1475556035
source EZB Electronic Journals Library
subjects Bolting
Bolts
Fracture mechanics
Hinges
Joints
Nails
Shear
Wood
title Experimental Investigations of the Shear Capacity of Nails in a Row
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-04T18%3A30%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Experimental%20Investigations%20of%20the%20Shear%20Capacity%20of%20Nails%20in%20a%20Row&rft.jtitle=Open%20journal%20of%20civil%20engineering&rft.au=S%C3%B8rensen,%20Christian%20O.&rft.date=2013-08-01&rft.volume=3&rft.issue=3&rft.spage=173&rft.epage=181&rft.pages=173-181&rft.issn=2164-3164&rft.eissn=2164-3172&rft_id=info:doi/10.4236/ojce.2013.33021&rft_dat=%3Cproquest_cross%3E1475556035%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1475556035&rft_id=info:pmid/&rfr_iscdi=true