Fiducial markers for image-guided partial breast irradiation

Purpose This study was undertaken to study the role of fiducial markers for image-guided partial breast irradiation (IG-PBI), and to compare the shifts based on bony anatomy and fiducial markers. Materials and methods Fifteen patients underwent IGPBI. Three fiducial markers were placed in the tumour...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiologia medica 2013-10, Vol.118 (7), p.1212-1219
Hauptverfasser: Trovo, Marco, Polesel, Jerry, Biasutti, Cristina, Sartor, Giovanna, Roncadin, Mario, Trovo, Gaetano Mauro
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1219
container_issue 7
container_start_page 1212
container_title Radiologia medica
container_volume 118
creator Trovo, Marco
Polesel, Jerry
Biasutti, Cristina
Sartor, Giovanna
Roncadin, Mario
Trovo, Gaetano Mauro
description Purpose This study was undertaken to study the role of fiducial markers for image-guided partial breast irradiation (IG-PBI), and to compare the shifts based on bony anatomy and fiducial markers. Materials and methods Fifteen patients underwent IGPBI. Three fiducial markers were placed in the tumour bed at the time of surgery. Daily orthogonal anterior/ posterior and lateral kV-images were taken before each fraction and compared with the digitally-reconstructed radiographs, both using bony landmarks and fiducial markers as reference. The Student’s t test was used to detect a meaningful difference of 3 mm in between the two methods. Results A total of 105 image-guided radiation therapy (IGRT) sessions were obtained. The mean superior/inferior, right/left, and anterior/posterior shifts obtained using the bony landmarks vs. the fiducial markers were 2 mm [standard deviation (SD) 10 mm] vs . 0 mm (SD 7 mm), 0 mm (SD 7 mm) vs . 1 mm (SD 4 mm), and 1 mm (SD 7 mm) vs . 0 mm (SD 5 mm), respectively. The mean shift differences in absolute value between the two methods, along the superior/inferior, right/left and anterior/posterior directions were 5 mm ( p =0.001), 3 mm [ p =not significant (ns)], and 3 mm ( p =ns), respectively. Conclusions Fiducial markers for IG-PBI increase set-up accuracy compared to the bony landmarks, in particular along the superior/inferior direction.
doi_str_mv 10.1007/s11547-013-0967-2
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1466375241</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1466375241</sourcerecordid><originalsourceid>FETCH-LOGICAL-c344t-b22e2731b4ec7a89267ca342d68a4625acee18ea4771277d25497f1ceeadd2af3</originalsourceid><addsrcrecordid>eNp9kLFOwzAQhi0EoqXwACwoI4vBPjt2IrGgigJSJRaYLSe-VC5NUuxk4O1xlcLIdNLdd__pPkKuObvjjOn7yHkuNWVcUFYqTeGEzHkBiqqyEKdkzpgQtBAKZuQixi1jknFWnpMZiKKEMldz8rDybqy93WWtDZ8YYtb0IfOt3SDdjN6hy_Y2DAegCmjjkPkQrPN28H13Sc4au4t4dawL8rF6el--0PXb8-vycU1rIeVAKwAELXglsdY2XVa6tkKCU4WVCnJbI_ICrdSag9YOclnqhqeudQ5sIxbkdsrdh_5rxDiY1scadzvbYT9Gw6VSQucgeUL5hNahjzFgY_YhfRO-DWfmIM1M0kySZg7SDKSdm2P8WLXo_jZ-LSUAJiCmUbfBYLb9GLr08j-pP8eCdww</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1466375241</pqid></control><display><type>article</type><title>Fiducial markers for image-guided partial breast irradiation</title><source>MEDLINE</source><source>SpringerLink Journals - AutoHoldings</source><creator>Trovo, Marco ; Polesel, Jerry ; Biasutti, Cristina ; Sartor, Giovanna ; Roncadin, Mario ; Trovo, Gaetano Mauro</creator><creatorcontrib>Trovo, Marco ; Polesel, Jerry ; Biasutti, Cristina ; Sartor, Giovanna ; Roncadin, Mario ; Trovo, Gaetano Mauro</creatorcontrib><description>Purpose This study was undertaken to study the role of fiducial markers for image-guided partial breast irradiation (IG-PBI), and to compare the shifts based on bony anatomy and fiducial markers. Materials and methods Fifteen patients underwent IGPBI. Three fiducial markers were placed in the tumour bed at the time of surgery. Daily orthogonal anterior/ posterior and lateral kV-images were taken before each fraction and compared with the digitally-reconstructed radiographs, both using bony landmarks and fiducial markers as reference. The Student’s t test was used to detect a meaningful difference of 3 mm in between the two methods. Results A total of 105 image-guided radiation therapy (IGRT) sessions were obtained. The mean superior/inferior, right/left, and anterior/posterior shifts obtained using the bony landmarks vs. the fiducial markers were 2 mm [standard deviation (SD) 10 mm] vs . 0 mm (SD 7 mm), 0 mm (SD 7 mm) vs . 1 mm (SD 4 mm), and 1 mm (SD 7 mm) vs . 0 mm (SD 5 mm), respectively. The mean shift differences in absolute value between the two methods, along the superior/inferior, right/left and anterior/posterior directions were 5 mm ( p =0.001), 3 mm [ p =not significant (ns)], and 3 mm ( p =ns), respectively. Conclusions Fiducial markers for IG-PBI increase set-up accuracy compared to the bony landmarks, in particular along the superior/inferior direction.</description><identifier>ISSN: 0033-8362</identifier><identifier>EISSN: 1826-6983</identifier><identifier>DOI: 10.1007/s11547-013-0967-2</identifier><identifier>PMID: 23892956</identifier><language>eng</language><publisher>Milan: Springer-Verlag</publisher><subject>Aged ; Breast Neoplasms - pathology ; Breast Neoplasms - radiotherapy ; Diagnostic Radiology ; Female ; Fiducial Markers ; Humans ; Imaging ; Interventional Radiology ; Medicine ; Medicine &amp; Public Health ; Middle Aged ; Neoplasm Grading ; Neoplasm Staging ; Neuroradiology ; Radiology ; Radioterapia ; Radiotherapy ; Radiotherapy Dosage ; Radiotherapy, Image-Guided - methods ; Treatment Outcome ; Ultrasound</subject><ispartof>Radiologia medica, 2013-10, Vol.118 (7), p.1212-1219</ispartof><rights>Springer-Verlag 2013</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c344t-b22e2731b4ec7a89267ca342d68a4625acee18ea4771277d25497f1ceeadd2af3</citedby><cites>FETCH-LOGICAL-c344t-b22e2731b4ec7a89267ca342d68a4625acee18ea4771277d25497f1ceeadd2af3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s11547-013-0967-2$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s11547-013-0967-2$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,41488,42557,51319</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23892956$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Trovo, Marco</creatorcontrib><creatorcontrib>Polesel, Jerry</creatorcontrib><creatorcontrib>Biasutti, Cristina</creatorcontrib><creatorcontrib>Sartor, Giovanna</creatorcontrib><creatorcontrib>Roncadin, Mario</creatorcontrib><creatorcontrib>Trovo, Gaetano Mauro</creatorcontrib><title>Fiducial markers for image-guided partial breast irradiation</title><title>Radiologia medica</title><addtitle>Radiol med</addtitle><addtitle>Radiol Med</addtitle><description>Purpose This study was undertaken to study the role of fiducial markers for image-guided partial breast irradiation (IG-PBI), and to compare the shifts based on bony anatomy and fiducial markers. Materials and methods Fifteen patients underwent IGPBI. Three fiducial markers were placed in the tumour bed at the time of surgery. Daily orthogonal anterior/ posterior and lateral kV-images were taken before each fraction and compared with the digitally-reconstructed radiographs, both using bony landmarks and fiducial markers as reference. The Student’s t test was used to detect a meaningful difference of 3 mm in between the two methods. Results A total of 105 image-guided radiation therapy (IGRT) sessions were obtained. The mean superior/inferior, right/left, and anterior/posterior shifts obtained using the bony landmarks vs. the fiducial markers were 2 mm [standard deviation (SD) 10 mm] vs . 0 mm (SD 7 mm), 0 mm (SD 7 mm) vs . 1 mm (SD 4 mm), and 1 mm (SD 7 mm) vs . 0 mm (SD 5 mm), respectively. The mean shift differences in absolute value between the two methods, along the superior/inferior, right/left and anterior/posterior directions were 5 mm ( p =0.001), 3 mm [ p =not significant (ns)], and 3 mm ( p =ns), respectively. Conclusions Fiducial markers for IG-PBI increase set-up accuracy compared to the bony landmarks, in particular along the superior/inferior direction.</description><subject>Aged</subject><subject>Breast Neoplasms - pathology</subject><subject>Breast Neoplasms - radiotherapy</subject><subject>Diagnostic Radiology</subject><subject>Female</subject><subject>Fiducial Markers</subject><subject>Humans</subject><subject>Imaging</subject><subject>Interventional Radiology</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Middle Aged</subject><subject>Neoplasm Grading</subject><subject>Neoplasm Staging</subject><subject>Neuroradiology</subject><subject>Radiology</subject><subject>Radioterapia</subject><subject>Radiotherapy</subject><subject>Radiotherapy Dosage</subject><subject>Radiotherapy, Image-Guided - methods</subject><subject>Treatment Outcome</subject><subject>Ultrasound</subject><issn>0033-8362</issn><issn>1826-6983</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kLFOwzAQhi0EoqXwACwoI4vBPjt2IrGgigJSJRaYLSe-VC5NUuxk4O1xlcLIdNLdd__pPkKuObvjjOn7yHkuNWVcUFYqTeGEzHkBiqqyEKdkzpgQtBAKZuQixi1jknFWnpMZiKKEMldz8rDybqy93WWtDZ8YYtb0IfOt3SDdjN6hy_Y2DAegCmjjkPkQrPN28H13Sc4au4t4dawL8rF6el--0PXb8-vycU1rIeVAKwAELXglsdY2XVa6tkKCU4WVCnJbI_ICrdSag9YOclnqhqeudQ5sIxbkdsrdh_5rxDiY1scadzvbYT9Gw6VSQucgeUL5hNahjzFgY_YhfRO-DWfmIM1M0kySZg7SDKSdm2P8WLXo_jZ-LSUAJiCmUbfBYLb9GLr08j-pP8eCdww</recordid><startdate>20131001</startdate><enddate>20131001</enddate><creator>Trovo, Marco</creator><creator>Polesel, Jerry</creator><creator>Biasutti, Cristina</creator><creator>Sartor, Giovanna</creator><creator>Roncadin, Mario</creator><creator>Trovo, Gaetano Mauro</creator><general>Springer-Verlag</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20131001</creationdate><title>Fiducial markers for image-guided partial breast irradiation</title><author>Trovo, Marco ; Polesel, Jerry ; Biasutti, Cristina ; Sartor, Giovanna ; Roncadin, Mario ; Trovo, Gaetano Mauro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c344t-b22e2731b4ec7a89267ca342d68a4625acee18ea4771277d25497f1ceeadd2af3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Aged</topic><topic>Breast Neoplasms - pathology</topic><topic>Breast Neoplasms - radiotherapy</topic><topic>Diagnostic Radiology</topic><topic>Female</topic><topic>Fiducial Markers</topic><topic>Humans</topic><topic>Imaging</topic><topic>Interventional Radiology</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Middle Aged</topic><topic>Neoplasm Grading</topic><topic>Neoplasm Staging</topic><topic>Neuroradiology</topic><topic>Radiology</topic><topic>Radioterapia</topic><topic>Radiotherapy</topic><topic>Radiotherapy Dosage</topic><topic>Radiotherapy, Image-Guided - methods</topic><topic>Treatment Outcome</topic><topic>Ultrasound</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Trovo, Marco</creatorcontrib><creatorcontrib>Polesel, Jerry</creatorcontrib><creatorcontrib>Biasutti, Cristina</creatorcontrib><creatorcontrib>Sartor, Giovanna</creatorcontrib><creatorcontrib>Roncadin, Mario</creatorcontrib><creatorcontrib>Trovo, Gaetano Mauro</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Radiologia medica</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Trovo, Marco</au><au>Polesel, Jerry</au><au>Biasutti, Cristina</au><au>Sartor, Giovanna</au><au>Roncadin, Mario</au><au>Trovo, Gaetano Mauro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fiducial markers for image-guided partial breast irradiation</atitle><jtitle>Radiologia medica</jtitle><stitle>Radiol med</stitle><addtitle>Radiol Med</addtitle><date>2013-10-01</date><risdate>2013</risdate><volume>118</volume><issue>7</issue><spage>1212</spage><epage>1219</epage><pages>1212-1219</pages><issn>0033-8362</issn><eissn>1826-6983</eissn><abstract>Purpose This study was undertaken to study the role of fiducial markers for image-guided partial breast irradiation (IG-PBI), and to compare the shifts based on bony anatomy and fiducial markers. Materials and methods Fifteen patients underwent IGPBI. Three fiducial markers were placed in the tumour bed at the time of surgery. Daily orthogonal anterior/ posterior and lateral kV-images were taken before each fraction and compared with the digitally-reconstructed radiographs, both using bony landmarks and fiducial markers as reference. The Student’s t test was used to detect a meaningful difference of 3 mm in between the two methods. Results A total of 105 image-guided radiation therapy (IGRT) sessions were obtained. The mean superior/inferior, right/left, and anterior/posterior shifts obtained using the bony landmarks vs. the fiducial markers were 2 mm [standard deviation (SD) 10 mm] vs . 0 mm (SD 7 mm), 0 mm (SD 7 mm) vs . 1 mm (SD 4 mm), and 1 mm (SD 7 mm) vs . 0 mm (SD 5 mm), respectively. The mean shift differences in absolute value between the two methods, along the superior/inferior, right/left and anterior/posterior directions were 5 mm ( p =0.001), 3 mm [ p =not significant (ns)], and 3 mm ( p =ns), respectively. Conclusions Fiducial markers for IG-PBI increase set-up accuracy compared to the bony landmarks, in particular along the superior/inferior direction.</abstract><cop>Milan</cop><pub>Springer-Verlag</pub><pmid>23892956</pmid><doi>10.1007/s11547-013-0967-2</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0033-8362
ispartof Radiologia medica, 2013-10, Vol.118 (7), p.1212-1219
issn 0033-8362
1826-6983
language eng
recordid cdi_proquest_miscellaneous_1466375241
source MEDLINE; SpringerLink Journals - AutoHoldings
subjects Aged
Breast Neoplasms - pathology
Breast Neoplasms - radiotherapy
Diagnostic Radiology
Female
Fiducial Markers
Humans
Imaging
Interventional Radiology
Medicine
Medicine & Public Health
Middle Aged
Neoplasm Grading
Neoplasm Staging
Neuroradiology
Radiology
Radioterapia
Radiotherapy
Radiotherapy Dosage
Radiotherapy, Image-Guided - methods
Treatment Outcome
Ultrasound
title Fiducial markers for image-guided partial breast irradiation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T15%3A05%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fiducial%20markers%20for%20image-guided%20partial%20breast%20irradiation&rft.jtitle=Radiologia%20medica&rft.au=Trovo,%20Marco&rft.date=2013-10-01&rft.volume=118&rft.issue=7&rft.spage=1212&rft.epage=1219&rft.pages=1212-1219&rft.issn=0033-8362&rft.eissn=1826-6983&rft_id=info:doi/10.1007/s11547-013-0967-2&rft_dat=%3Cproquest_cross%3E1466375241%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1466375241&rft_id=info:pmid/23892956&rfr_iscdi=true