The evaluation of working casts prepared from digital impressions

The aim of this study is to evaluate the reproducibility of working casts of a digital impression system by comparing them with the original, virtual, and rapid prototyping casts. A total of 54 cast sets in clinically stable occlusion were used. They were scanned by an iTero intraoral scanner and co...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Operative dentistry 2013-11, Vol.38 (6), p.655-662
Hauptverfasser: Hwang, Y C, Park, Y S, Kim, H K, Hong, Y S, Ahn, J S, Ryu, J J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 662
container_issue 6
container_start_page 655
container_title Operative dentistry
container_volume 38
creator Hwang, Y C
Park, Y S
Kim, H K
Hong, Y S
Ahn, J S
Ryu, J J
description The aim of this study is to evaluate the reproducibility of working casts of a digital impression system by comparing them with the original, virtual, and rapid prototyping casts. A total of 54 cast sets in clinically stable occlusion were used. They were scanned by an iTero intraoral scanner and converted into STL format virtual casts. Rapid prototyping casts and polyurethane casts were fabricated from the iTero milling system based on the virtual casts. Several horizontal and vertical measurements were performed from the four types of casts, that is, original stone casts, virtual casts, rapid prototyping casts, and polyurethane casts of iTero. Measurement error, intraclass correlation coefficient (ICC), and differences among the casts were calculated and compared. Casts from iTero milling machines exhibited greater dimensional differences and lower ICC values than did other casts. In addition, many of the measurements of the iTero working casts showed statistically significant differences in comparison to the three other types of casts. In contrast, there were no statistically significant differences between the virtual and original casts. Virtual casts made by the iTero intraoral scanner exhibited excellent reproducibility. However, the casts from the iTero milling machine showed greater dimensional differences and lower reproducibility compared to other types of casts.
doi_str_mv 10.2341/12-352-l
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1459161746</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1459161746</sourcerecordid><originalsourceid>FETCH-LOGICAL-c383t-e58700c4145fe4cdfce188b2d584742519abdaf160e0855cdcc1fbd7b750cefb3</originalsourceid><addsrcrecordid>eNpFkEtLxDAURoMoTh0Ff4Fk6aaam0fTWQ6DLxhwM65DmtyM1XZak1bx31tx1NWFy_nO4hByDuyKCwnXwHOheN4ckAyUWuS8LMQhyZgoINdayBk5SemFMamkUsdkxoXSTDDIyHLzjBTfbTPaoe52tAv0o4uv9W5LnU1Don3E3kb0NMSupb7e1oNtaN1O_5SmRTolR8E2Cc_2d06ebm82q_t8_Xj3sFqucydKMeSoSs2YkyBVQOl8cAhlWXGvSqklV7CwlbcBCoasVMp55yBUXldaMYehEnNy-ePtY_c2YhpMWyeHTWN32I3JTOIFFKBl8Y-62KUUMZg-1q2NnwaY-Q5mgJspmFlP6MXeOlYt-j_wt5D4AmptZfA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1459161746</pqid></control><display><type>article</type><title>The evaluation of working casts prepared from digital impressions</title><source>MEDLINE</source><source>Allen Press Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Hwang, Y C ; Park, Y S ; Kim, H K ; Hong, Y S ; Ahn, J S ; Ryu, J J</creator><creatorcontrib>Hwang, Y C ; Park, Y S ; Kim, H K ; Hong, Y S ; Ahn, J S ; Ryu, J J</creatorcontrib><description>The aim of this study is to evaluate the reproducibility of working casts of a digital impression system by comparing them with the original, virtual, and rapid prototyping casts. A total of 54 cast sets in clinically stable occlusion were used. They were scanned by an iTero intraoral scanner and converted into STL format virtual casts. Rapid prototyping casts and polyurethane casts were fabricated from the iTero milling system based on the virtual casts. Several horizontal and vertical measurements were performed from the four types of casts, that is, original stone casts, virtual casts, rapid prototyping casts, and polyurethane casts of iTero. Measurement error, intraclass correlation coefficient (ICC), and differences among the casts were calculated and compared. Casts from iTero milling machines exhibited greater dimensional differences and lower ICC values than did other casts. In addition, many of the measurements of the iTero working casts showed statistically significant differences in comparison to the three other types of casts. In contrast, there were no statistically significant differences between the virtual and original casts. Virtual casts made by the iTero intraoral scanner exhibited excellent reproducibility. However, the casts from the iTero milling machine showed greater dimensional differences and lower reproducibility compared to other types of casts.</description><identifier>ISSN: 0361-7734</identifier><identifier>EISSN: 1559-2863</identifier><identifier>DOI: 10.2341/12-352-l</identifier><identifier>PMID: 23570301</identifier><language>eng</language><publisher>United States</publisher><subject>Dental Impression Technique ; Dentistry ; Humans ; Imaging, Three-Dimensional - methods ; Reproducibility of Results ; Software ; User-Computer Interface</subject><ispartof>Operative dentistry, 2013-11, Vol.38 (6), p.655-662</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c383t-e58700c4145fe4cdfce188b2d584742519abdaf160e0855cdcc1fbd7b750cefb3</citedby><cites>FETCH-LOGICAL-c383t-e58700c4145fe4cdfce188b2d584742519abdaf160e0855cdcc1fbd7b750cefb3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,782,786,27931,27932</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23570301$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hwang, Y C</creatorcontrib><creatorcontrib>Park, Y S</creatorcontrib><creatorcontrib>Kim, H K</creatorcontrib><creatorcontrib>Hong, Y S</creatorcontrib><creatorcontrib>Ahn, J S</creatorcontrib><creatorcontrib>Ryu, J J</creatorcontrib><title>The evaluation of working casts prepared from digital impressions</title><title>Operative dentistry</title><addtitle>Oper Dent</addtitle><description>The aim of this study is to evaluate the reproducibility of working casts of a digital impression system by comparing them with the original, virtual, and rapid prototyping casts. A total of 54 cast sets in clinically stable occlusion were used. They were scanned by an iTero intraoral scanner and converted into STL format virtual casts. Rapid prototyping casts and polyurethane casts were fabricated from the iTero milling system based on the virtual casts. Several horizontal and vertical measurements were performed from the four types of casts, that is, original stone casts, virtual casts, rapid prototyping casts, and polyurethane casts of iTero. Measurement error, intraclass correlation coefficient (ICC), and differences among the casts were calculated and compared. Casts from iTero milling machines exhibited greater dimensional differences and lower ICC values than did other casts. In addition, many of the measurements of the iTero working casts showed statistically significant differences in comparison to the three other types of casts. In contrast, there were no statistically significant differences between the virtual and original casts. Virtual casts made by the iTero intraoral scanner exhibited excellent reproducibility. However, the casts from the iTero milling machine showed greater dimensional differences and lower reproducibility compared to other types of casts.</description><subject>Dental Impression Technique</subject><subject>Dentistry</subject><subject>Humans</subject><subject>Imaging, Three-Dimensional - methods</subject><subject>Reproducibility of Results</subject><subject>Software</subject><subject>User-Computer Interface</subject><issn>0361-7734</issn><issn>1559-2863</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkEtLxDAURoMoTh0Ff4Fk6aaam0fTWQ6DLxhwM65DmtyM1XZak1bx31tx1NWFy_nO4hByDuyKCwnXwHOheN4ckAyUWuS8LMQhyZgoINdayBk5SemFMamkUsdkxoXSTDDIyHLzjBTfbTPaoe52tAv0o4uv9W5LnU1Don3E3kb0NMSupb7e1oNtaN1O_5SmRTolR8E2Cc_2d06ebm82q_t8_Xj3sFqucydKMeSoSs2YkyBVQOl8cAhlWXGvSqklV7CwlbcBCoasVMp55yBUXldaMYehEnNy-ePtY_c2YhpMWyeHTWN32I3JTOIFFKBl8Y-62KUUMZg-1q2NnwaY-Q5mgJspmFlP6MXeOlYt-j_wt5D4AmptZfA</recordid><startdate>201311</startdate><enddate>201311</enddate><creator>Hwang, Y C</creator><creator>Park, Y S</creator><creator>Kim, H K</creator><creator>Hong, Y S</creator><creator>Ahn, J S</creator><creator>Ryu, J J</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201311</creationdate><title>The evaluation of working casts prepared from digital impressions</title><author>Hwang, Y C ; Park, Y S ; Kim, H K ; Hong, Y S ; Ahn, J S ; Ryu, J J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c383t-e58700c4145fe4cdfce188b2d584742519abdaf160e0855cdcc1fbd7b750cefb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Dental Impression Technique</topic><topic>Dentistry</topic><topic>Humans</topic><topic>Imaging, Three-Dimensional - methods</topic><topic>Reproducibility of Results</topic><topic>Software</topic><topic>User-Computer Interface</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hwang, Y C</creatorcontrib><creatorcontrib>Park, Y S</creatorcontrib><creatorcontrib>Kim, H K</creatorcontrib><creatorcontrib>Hong, Y S</creatorcontrib><creatorcontrib>Ahn, J S</creatorcontrib><creatorcontrib>Ryu, J J</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Operative dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hwang, Y C</au><au>Park, Y S</au><au>Kim, H K</au><au>Hong, Y S</au><au>Ahn, J S</au><au>Ryu, J J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The evaluation of working casts prepared from digital impressions</atitle><jtitle>Operative dentistry</jtitle><addtitle>Oper Dent</addtitle><date>2013-11</date><risdate>2013</risdate><volume>38</volume><issue>6</issue><spage>655</spage><epage>662</epage><pages>655-662</pages><issn>0361-7734</issn><eissn>1559-2863</eissn><abstract>The aim of this study is to evaluate the reproducibility of working casts of a digital impression system by comparing them with the original, virtual, and rapid prototyping casts. A total of 54 cast sets in clinically stable occlusion were used. They were scanned by an iTero intraoral scanner and converted into STL format virtual casts. Rapid prototyping casts and polyurethane casts were fabricated from the iTero milling system based on the virtual casts. Several horizontal and vertical measurements were performed from the four types of casts, that is, original stone casts, virtual casts, rapid prototyping casts, and polyurethane casts of iTero. Measurement error, intraclass correlation coefficient (ICC), and differences among the casts were calculated and compared. Casts from iTero milling machines exhibited greater dimensional differences and lower ICC values than did other casts. In addition, many of the measurements of the iTero working casts showed statistically significant differences in comparison to the three other types of casts. In contrast, there were no statistically significant differences between the virtual and original casts. Virtual casts made by the iTero intraoral scanner exhibited excellent reproducibility. However, the casts from the iTero milling machine showed greater dimensional differences and lower reproducibility compared to other types of casts.</abstract><cop>United States</cop><pmid>23570301</pmid><doi>10.2341/12-352-l</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0361-7734
ispartof Operative dentistry, 2013-11, Vol.38 (6), p.655-662
issn 0361-7734
1559-2863
language eng
recordid cdi_proquest_miscellaneous_1459161746
source MEDLINE; Allen Press Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection
subjects Dental Impression Technique
Dentistry
Humans
Imaging, Three-Dimensional - methods
Reproducibility of Results
Software
User-Computer Interface
title The evaluation of working casts prepared from digital impressions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-05T04%3A43%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20evaluation%20of%20working%20casts%20prepared%20from%20digital%20impressions&rft.jtitle=Operative%20dentistry&rft.au=Hwang,%20Y%20C&rft.date=2013-11&rft.volume=38&rft.issue=6&rft.spage=655&rft.epage=662&rft.pages=655-662&rft.issn=0361-7734&rft.eissn=1559-2863&rft_id=info:doi/10.2341/12-352-l&rft_dat=%3Cproquest_cross%3E1459161746%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1459161746&rft_id=info:pmid/23570301&rfr_iscdi=true