Relative ion yields measured with a high-resolution glow discharge mass spectrometer operated with an argon/hydrogen mixture

Quantitative elemental analysis by glow discharge mass spectrometry (GDMS) requires a calibration factor for each element. The calibration factors used in the present work are called relative ion yields (RIYs). The RIYs of each of 19 elements within samples of four National Institute of Standards an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the American Society for Mass Spectrometry 1993-03, Vol.4 (3), p.278-285
Hauptverfasser: Smithwick, R.W., Lynch, D.W., Franklin, J.C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 285
container_issue 3
container_start_page 278
container_title Journal of the American Society for Mass Spectrometry
container_volume 4
creator Smithwick, R.W.
Lynch, D.W.
Franklin, J.C.
description Quantitative elemental analysis by glow discharge mass spectrometry (GDMS) requires a calibration factor for each element. The calibration factors used in the present work are called relative ion yields (RIYs). The RIYs of each of 19 elements within samples of four National Institute of Standards and Technology steel reference materials (nos. 661-664) were measured using pure argon and an argon mixture containing 1.0% hydrogen by volume. The RIYs measured using pure argon correlated within a factor of approximately 2–3 to the RIYs calculated by a theoretical model. The RIYs measured for these 19 elements using the argon mixture containing 1.0% hydrogen correlated within a factor of approximately 1.3 to the calculated RIYs. These results may have significant analytical potential with respect to GDMS and may have application to other plasma techniques.
doi_str_mv 10.1016/1044-0305(93)85092-C
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1459159288</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>104403059385092C</els_id><sourcerecordid>1459159288</sourcerecordid><originalsourceid>FETCH-LOGICAL-c435t-d0a8ce488a5496553473637769767c5bf420140e9fb564071ea84e64bf30a7493</originalsourceid><addsrcrecordid>eNp9kMFq3DAQhkVpSdI0b1CKDj2kByeSJVnSJVCWpC0EAiE5C608XqvY1kaSky7k4avtbvbY08zhm_l_PoQ-U3JBCW0uKeG8IoyIc82-KUF0XS3eoROqpK4ordn7sr8hx-hjSr8JoZJoeYSOa14zroQ6Qa_3MNjsnwH7MOGNh6FNeASb5ggtfvG5xxb3ftVXEVIY5rzFVkN4wa1PrrdxBXi0KeG0BpdjGCFDxGEN0ebDgwkXLkyX_aaNYQUTHv2fXAI-oQ-dHRKc7ecpery5flj8rG7vfvxafL-tHGciVy2xygFXygquGyEYl6xhUjZaNtKJZcdrQjkB3S1Fw4mkYBWHhi87Rqzkmp2i893fdQxPM6RsxlIehsFOEOZkKBeaCl0rVVC-Q10MKUXozDr60caNocRsvZutVLOVajQz_7ybRTn7sk-YlyO0h6M30QX4ugdscnboop2cTweON1IoSQp2tcOg6Hj2EE1yHiYHrY_Fr2mD_3-Rvxshn8s</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1459159288</pqid></control><display><type>article</type><title>Relative ion yields measured with a high-resolution glow discharge mass spectrometer operated with an argon/hydrogen mixture</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><source>Free Full-Text Journals in Chemistry</source><creator>Smithwick, R.W. ; Lynch, D.W. ; Franklin, J.C.</creator><creatorcontrib>Smithwick, R.W. ; Lynch, D.W. ; Franklin, J.C.</creatorcontrib><description>Quantitative elemental analysis by glow discharge mass spectrometry (GDMS) requires a calibration factor for each element. The calibration factors used in the present work are called relative ion yields (RIYs). The RIYs of each of 19 elements within samples of four National Institute of Standards and Technology steel reference materials (nos. 661-664) were measured using pure argon and an argon mixture containing 1.0% hydrogen by volume. The RIYs measured using pure argon correlated within a factor of approximately 2–3 to the RIYs calculated by a theoretical model. The RIYs measured for these 19 elements using the argon mixture containing 1.0% hydrogen correlated within a factor of approximately 1.3 to the calculated RIYs. These results may have significant analytical potential with respect to GDMS and may have application to other plasma techniques.</description><identifier>ISSN: 1044-0305</identifier><identifier>EISSN: 1879-1123</identifier><identifier>DOI: 10.1016/1044-0305(93)85092-C</identifier><identifier>PMID: 24234858</identifier><language>eng</language><publisher>New York, NY: Elsevier Inc</publisher><subject>Analytical chemistry ; Chemistry ; Exact sciences and technology ; Spectrometric and optical methods</subject><ispartof>Journal of the American Society for Mass Spectrometry, 1993-03, Vol.4 (3), p.278-285</ispartof><rights>1993</rights><rights>1993 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c435t-d0a8ce488a5496553473637769767c5bf420140e9fb564071ea84e64bf30a7493</citedby><cites>FETCH-LOGICAL-c435t-d0a8ce488a5496553473637769767c5bf420140e9fb564071ea84e64bf30a7493</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=4675870$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24234858$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Smithwick, R.W.</creatorcontrib><creatorcontrib>Lynch, D.W.</creatorcontrib><creatorcontrib>Franklin, J.C.</creatorcontrib><title>Relative ion yields measured with a high-resolution glow discharge mass spectrometer operated with an argon/hydrogen mixture</title><title>Journal of the American Society for Mass Spectrometry</title><addtitle>J Am Soc Mass Spectrom</addtitle><description>Quantitative elemental analysis by glow discharge mass spectrometry (GDMS) requires a calibration factor for each element. The calibration factors used in the present work are called relative ion yields (RIYs). The RIYs of each of 19 elements within samples of four National Institute of Standards and Technology steel reference materials (nos. 661-664) were measured using pure argon and an argon mixture containing 1.0% hydrogen by volume. The RIYs measured using pure argon correlated within a factor of approximately 2–3 to the RIYs calculated by a theoretical model. The RIYs measured for these 19 elements using the argon mixture containing 1.0% hydrogen correlated within a factor of approximately 1.3 to the calculated RIYs. These results may have significant analytical potential with respect to GDMS and may have application to other plasma techniques.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Exact sciences and technology</subject><subject>Spectrometric and optical methods</subject><issn>1044-0305</issn><issn>1879-1123</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1993</creationdate><recordtype>article</recordtype><recordid>eNp9kMFq3DAQhkVpSdI0b1CKDj2kByeSJVnSJVCWpC0EAiE5C608XqvY1kaSky7k4avtbvbY08zhm_l_PoQ-U3JBCW0uKeG8IoyIc82-KUF0XS3eoROqpK4ordn7sr8hx-hjSr8JoZJoeYSOa14zroQ6Qa_3MNjsnwH7MOGNh6FNeASb5ggtfvG5xxb3ftVXEVIY5rzFVkN4wa1PrrdxBXi0KeG0BpdjGCFDxGEN0ebDgwkXLkyX_aaNYQUTHv2fXAI-oQ-dHRKc7ecpery5flj8rG7vfvxafL-tHGciVy2xygFXygquGyEYl6xhUjZaNtKJZcdrQjkB3S1Fw4mkYBWHhi87Rqzkmp2i893fdQxPM6RsxlIehsFOEOZkKBeaCl0rVVC-Q10MKUXozDr60caNocRsvZutVLOVajQz_7ybRTn7sk-YlyO0h6M30QX4ugdscnboop2cTweON1IoSQp2tcOg6Hj2EE1yHiYHrY_Fr2mD_3-Rvxshn8s</recordid><startdate>19930301</startdate><enddate>19930301</enddate><creator>Smithwick, R.W.</creator><creator>Lynch, D.W.</creator><creator>Franklin, J.C.</creator><general>Elsevier Inc</general><general>Elsevier Science</general><scope>6I.</scope><scope>AAFTH</scope><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19930301</creationdate><title>Relative ion yields measured with a high-resolution glow discharge mass spectrometer operated with an argon/hydrogen mixture</title><author>Smithwick, R.W. ; Lynch, D.W. ; Franklin, J.C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c435t-d0a8ce488a5496553473637769767c5bf420140e9fb564071ea84e64bf30a7493</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1993</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Exact sciences and technology</topic><topic>Spectrometric and optical methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Smithwick, R.W.</creatorcontrib><creatorcontrib>Lynch, D.W.</creatorcontrib><creatorcontrib>Franklin, J.C.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the American Society for Mass Spectrometry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Smithwick, R.W.</au><au>Lynch, D.W.</au><au>Franklin, J.C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Relative ion yields measured with a high-resolution glow discharge mass spectrometer operated with an argon/hydrogen mixture</atitle><jtitle>Journal of the American Society for Mass Spectrometry</jtitle><addtitle>J Am Soc Mass Spectrom</addtitle><date>1993-03-01</date><risdate>1993</risdate><volume>4</volume><issue>3</issue><spage>278</spage><epage>285</epage><pages>278-285</pages><issn>1044-0305</issn><eissn>1879-1123</eissn><abstract>Quantitative elemental analysis by glow discharge mass spectrometry (GDMS) requires a calibration factor for each element. The calibration factors used in the present work are called relative ion yields (RIYs). The RIYs of each of 19 elements within samples of four National Institute of Standards and Technology steel reference materials (nos. 661-664) were measured using pure argon and an argon mixture containing 1.0% hydrogen by volume. The RIYs measured using pure argon correlated within a factor of approximately 2–3 to the RIYs calculated by a theoretical model. The RIYs measured for these 19 elements using the argon mixture containing 1.0% hydrogen correlated within a factor of approximately 1.3 to the calculated RIYs. These results may have significant analytical potential with respect to GDMS and may have application to other plasma techniques.</abstract><cop>New York, NY</cop><pub>Elsevier Inc</pub><pmid>24234858</pmid><doi>10.1016/1044-0305(93)85092-C</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1044-0305
ispartof Journal of the American Society for Mass Spectrometry, 1993-03, Vol.4 (3), p.278-285
issn 1044-0305
1879-1123
language eng
recordid cdi_proquest_miscellaneous_1459159288
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection; Free Full-Text Journals in Chemistry
subjects Analytical chemistry
Chemistry
Exact sciences and technology
Spectrometric and optical methods
title Relative ion yields measured with a high-resolution glow discharge mass spectrometer operated with an argon/hydrogen mixture
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T08%3A33%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Relative%20ion%20yields%20measured%20with%20a%20high-resolution%20glow%20discharge%20mass%20spectrometer%20operated%20with%20an%20argon/hydrogen%20mixture&rft.jtitle=Journal%20of%20the%20American%20Society%20for%20Mass%20Spectrometry&rft.au=Smithwick,%20R.W.&rft.date=1993-03-01&rft.volume=4&rft.issue=3&rft.spage=278&rft.epage=285&rft.pages=278-285&rft.issn=1044-0305&rft.eissn=1879-1123&rft_id=info:doi/10.1016/1044-0305(93)85092-C&rft_dat=%3Cproquest_cross%3E1459159288%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1459159288&rft_id=info:pmid/24234858&rft_els_id=104403059385092C&rfr_iscdi=true