The use of intralaminar screws in patients with spinal deformity
Retrospective study. To demonstrate that intralaminar screws (ILS) can be used as supplements in spinal deformity surgery in the thoracic and lumbar levels in pediatric and adult patients. Rigid posterior fixation of the spine is generally accomplished using pedicle screws, hooks, or wires. ILSs are...
Gespeichert in:
Veröffentlicht in: | Journal of spinal disorders & techniques 2013-12, Vol.26 (8), p.E299-E305 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | E305 |
---|---|
container_issue | 8 |
container_start_page | E299 |
container_title | Journal of spinal disorders & techniques |
container_volume | 26 |
creator | Kose, Kamil C Inanmaz, Mustafa E Atmaca, Halil Basar, Hakan Isik, Cengiz Bal, Emre |
description | Retrospective study.
To demonstrate that intralaminar screws (ILS) can be used as supplements in spinal deformity surgery in the thoracic and lumbar levels in pediatric and adult patients.
Rigid posterior fixation of the spine is generally accomplished using pedicle screws, hooks, or wires. ILSs are useful tools when other spinal fixation techniques have failed or the bony anatomy precludes hook or screw placement.
All spinal deformity patients (primary/revision) operated between 2007 and 2011 were retrospectively reviewed. The patients with ILS were included in the study. The anteroposterior and lateral standing x-rays were evaluated in terms of preoperative and postoperative coronal and sagittal deformities. The number and level of ILS, intraoperative complications, and postoperative complications were noted.
There were 20 patients (12 male and 8 female). The mean age was 21.75 years. The mean follow-up period was 17.4 months. Fifty-seven ILS were inserted. Seventeen screws were used in the uppermost to lowermost levels. Forty screws were used in the middle. There was 1 lamina fracture and screw pull out (1.75%). There were 3 canal violations (corrected intraoperative) and 2 instrument prominences which required implant removal. The mean preoperative/postoperative cobb angles were 78.5 degrees/27.8 degrees and the mean preoperative/postoperative kyphosis angles were 57.2 degrees/32.5 degrees, respectively. The loss of correction was 1.2 degrees. There were no neurological deficits and no instrument failures.
ILS are safe and effective when used in deformity correction. However, biomechanical studies and randomized controlled trials are needed to conclude whether ILS will be considered a first-line technique, or will remain a technique for salvage situations. |
doi_str_mv | 10.1097/BSD.0b013e31828804a7 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1459150025</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1459150025</sourcerecordid><originalsourceid>FETCH-LOGICAL-c307t-6e541a63cc9a073b449d94ce1d4ddb5ea31b6263ff48fc4d8f937c0300ebc3db3</originalsourceid><addsrcrecordid>eNpdkEtPwzAQhC0EoqXwDxDykUvKOraT-AaUp1SJA-UcOfZaDcoLO1HVf99ACwdOu9qZ2ZE-Qi4ZzBmo9Ob-_WEOBTCOnGVxloHQ6RGZMslVFItEHv_sSQSJjCfkLIRPAJZyIU7JJOYiVhzSKbldrZEOAWnraNn0Xle6LhvtaTAeN2G80U73JTZ9oJuyX9PQjXJFLbrW12W_PScnTlcBLw5zRj6eHleLl2j59vy6uFtGZuzpowSlYDrhxigNKS-EUFYJg8wKawuJmrMiiRPunMicETZziqcGOAAWhtuCz8j1_m_n268BQ5_XZTBYVbrBdgg5E1IxCRDL0Sr2VuPbEDy6vPNlrf02Z5B_s8tHdvl_dmPs6tAwFDXav9AvLL4D275rPA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1459150025</pqid></control><display><type>article</type><title>The use of intralaminar screws in patients with spinal deformity</title><source>MEDLINE</source><source>Journals@Ovid Ovid Autoload</source><creator>Kose, Kamil C ; Inanmaz, Mustafa E ; Atmaca, Halil ; Basar, Hakan ; Isik, Cengiz ; Bal, Emre</creator><creatorcontrib>Kose, Kamil C ; Inanmaz, Mustafa E ; Atmaca, Halil ; Basar, Hakan ; Isik, Cengiz ; Bal, Emre</creatorcontrib><description>Retrospective study.
To demonstrate that intralaminar screws (ILS) can be used as supplements in spinal deformity surgery in the thoracic and lumbar levels in pediatric and adult patients.
Rigid posterior fixation of the spine is generally accomplished using pedicle screws, hooks, or wires. ILSs are useful tools when other spinal fixation techniques have failed or the bony anatomy precludes hook or screw placement.
All spinal deformity patients (primary/revision) operated between 2007 and 2011 were retrospectively reviewed. The patients with ILS were included in the study. The anteroposterior and lateral standing x-rays were evaluated in terms of preoperative and postoperative coronal and sagittal deformities. The number and level of ILS, intraoperative complications, and postoperative complications were noted.
There were 20 patients (12 male and 8 female). The mean age was 21.75 years. The mean follow-up period was 17.4 months. Fifty-seven ILS were inserted. Seventeen screws were used in the uppermost to lowermost levels. Forty screws were used in the middle. There was 1 lamina fracture and screw pull out (1.75%). There were 3 canal violations (corrected intraoperative) and 2 instrument prominences which required implant removal. The mean preoperative/postoperative cobb angles were 78.5 degrees/27.8 degrees and the mean preoperative/postoperative kyphosis angles were 57.2 degrees/32.5 degrees, respectively. The loss of correction was 1.2 degrees. There were no neurological deficits and no instrument failures.
ILS are safe and effective when used in deformity correction. However, biomechanical studies and randomized controlled trials are needed to conclude whether ILS will be considered a first-line technique, or will remain a technique for salvage situations.</description><identifier>ISSN: 1536-0652</identifier><identifier>EISSN: 1539-2465</identifier><identifier>DOI: 10.1097/BSD.0b013e31828804a7</identifier><identifier>PMID: 23429307</identifier><language>eng</language><publisher>United States</publisher><subject>Adolescent ; Adult ; Bone Screws ; Child ; Child, Preschool ; Female ; Humans ; Intraoperative Care ; Kyphosis - diagnostic imaging ; Kyphosis - surgery ; Male ; Middle Aged ; Postoperative Care ; Radiography ; Scoliosis - diagnostic imaging ; Scoliosis - surgery</subject><ispartof>Journal of spinal disorders & techniques, 2013-12, Vol.26 (8), p.E299-E305</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c307t-6e541a63cc9a073b449d94ce1d4ddb5ea31b6263ff48fc4d8f937c0300ebc3db3</citedby><cites>FETCH-LOGICAL-c307t-6e541a63cc9a073b449d94ce1d4ddb5ea31b6263ff48fc4d8f937c0300ebc3db3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23429307$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kose, Kamil C</creatorcontrib><creatorcontrib>Inanmaz, Mustafa E</creatorcontrib><creatorcontrib>Atmaca, Halil</creatorcontrib><creatorcontrib>Basar, Hakan</creatorcontrib><creatorcontrib>Isik, Cengiz</creatorcontrib><creatorcontrib>Bal, Emre</creatorcontrib><title>The use of intralaminar screws in patients with spinal deformity</title><title>Journal of spinal disorders & techniques</title><addtitle>J Spinal Disord Tech</addtitle><description>Retrospective study.
To demonstrate that intralaminar screws (ILS) can be used as supplements in spinal deformity surgery in the thoracic and lumbar levels in pediatric and adult patients.
Rigid posterior fixation of the spine is generally accomplished using pedicle screws, hooks, or wires. ILSs are useful tools when other spinal fixation techniques have failed or the bony anatomy precludes hook or screw placement.
All spinal deformity patients (primary/revision) operated between 2007 and 2011 were retrospectively reviewed. The patients with ILS were included in the study. The anteroposterior and lateral standing x-rays were evaluated in terms of preoperative and postoperative coronal and sagittal deformities. The number and level of ILS, intraoperative complications, and postoperative complications were noted.
There were 20 patients (12 male and 8 female). The mean age was 21.75 years. The mean follow-up period was 17.4 months. Fifty-seven ILS were inserted. Seventeen screws were used in the uppermost to lowermost levels. Forty screws were used in the middle. There was 1 lamina fracture and screw pull out (1.75%). There were 3 canal violations (corrected intraoperative) and 2 instrument prominences which required implant removal. The mean preoperative/postoperative cobb angles were 78.5 degrees/27.8 degrees and the mean preoperative/postoperative kyphosis angles were 57.2 degrees/32.5 degrees, respectively. The loss of correction was 1.2 degrees. There were no neurological deficits and no instrument failures.
ILS are safe and effective when used in deformity correction. However, biomechanical studies and randomized controlled trials are needed to conclude whether ILS will be considered a first-line technique, or will remain a technique for salvage situations.</description><subject>Adolescent</subject><subject>Adult</subject><subject>Bone Screws</subject><subject>Child</subject><subject>Child, Preschool</subject><subject>Female</subject><subject>Humans</subject><subject>Intraoperative Care</subject><subject>Kyphosis - diagnostic imaging</subject><subject>Kyphosis - surgery</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Postoperative Care</subject><subject>Radiography</subject><subject>Scoliosis - diagnostic imaging</subject><subject>Scoliosis - surgery</subject><issn>1536-0652</issn><issn>1539-2465</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpdkEtPwzAQhC0EoqXwDxDykUvKOraT-AaUp1SJA-UcOfZaDcoLO1HVf99ACwdOu9qZ2ZE-Qi4ZzBmo9Ob-_WEOBTCOnGVxloHQ6RGZMslVFItEHv_sSQSJjCfkLIRPAJZyIU7JJOYiVhzSKbldrZEOAWnraNn0Xle6LhvtaTAeN2G80U73JTZ9oJuyX9PQjXJFLbrW12W_PScnTlcBLw5zRj6eHleLl2j59vy6uFtGZuzpowSlYDrhxigNKS-EUFYJg8wKawuJmrMiiRPunMicETZziqcGOAAWhtuCz8j1_m_n268BQ5_XZTBYVbrBdgg5E1IxCRDL0Sr2VuPbEDy6vPNlrf02Z5B_s8tHdvl_dmPs6tAwFDXav9AvLL4D275rPA</recordid><startdate>20131201</startdate><enddate>20131201</enddate><creator>Kose, Kamil C</creator><creator>Inanmaz, Mustafa E</creator><creator>Atmaca, Halil</creator><creator>Basar, Hakan</creator><creator>Isik, Cengiz</creator><creator>Bal, Emre</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20131201</creationdate><title>The use of intralaminar screws in patients with spinal deformity</title><author>Kose, Kamil C ; Inanmaz, Mustafa E ; Atmaca, Halil ; Basar, Hakan ; Isik, Cengiz ; Bal, Emre</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c307t-6e541a63cc9a073b449d94ce1d4ddb5ea31b6263ff48fc4d8f937c0300ebc3db3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Adolescent</topic><topic>Adult</topic><topic>Bone Screws</topic><topic>Child</topic><topic>Child, Preschool</topic><topic>Female</topic><topic>Humans</topic><topic>Intraoperative Care</topic><topic>Kyphosis - diagnostic imaging</topic><topic>Kyphosis - surgery</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Postoperative Care</topic><topic>Radiography</topic><topic>Scoliosis - diagnostic imaging</topic><topic>Scoliosis - surgery</topic><toplevel>online_resources</toplevel><creatorcontrib>Kose, Kamil C</creatorcontrib><creatorcontrib>Inanmaz, Mustafa E</creatorcontrib><creatorcontrib>Atmaca, Halil</creatorcontrib><creatorcontrib>Basar, Hakan</creatorcontrib><creatorcontrib>Isik, Cengiz</creatorcontrib><creatorcontrib>Bal, Emre</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of spinal disorders & techniques</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kose, Kamil C</au><au>Inanmaz, Mustafa E</au><au>Atmaca, Halil</au><au>Basar, Hakan</au><au>Isik, Cengiz</au><au>Bal, Emre</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The use of intralaminar screws in patients with spinal deformity</atitle><jtitle>Journal of spinal disorders & techniques</jtitle><addtitle>J Spinal Disord Tech</addtitle><date>2013-12-01</date><risdate>2013</risdate><volume>26</volume><issue>8</issue><spage>E299</spage><epage>E305</epage><pages>E299-E305</pages><issn>1536-0652</issn><eissn>1539-2465</eissn><abstract>Retrospective study.
To demonstrate that intralaminar screws (ILS) can be used as supplements in spinal deformity surgery in the thoracic and lumbar levels in pediatric and adult patients.
Rigid posterior fixation of the spine is generally accomplished using pedicle screws, hooks, or wires. ILSs are useful tools when other spinal fixation techniques have failed or the bony anatomy precludes hook or screw placement.
All spinal deformity patients (primary/revision) operated between 2007 and 2011 were retrospectively reviewed. The patients with ILS were included in the study. The anteroposterior and lateral standing x-rays were evaluated in terms of preoperative and postoperative coronal and sagittal deformities. The number and level of ILS, intraoperative complications, and postoperative complications were noted.
There were 20 patients (12 male and 8 female). The mean age was 21.75 years. The mean follow-up period was 17.4 months. Fifty-seven ILS were inserted. Seventeen screws were used in the uppermost to lowermost levels. Forty screws were used in the middle. There was 1 lamina fracture and screw pull out (1.75%). There were 3 canal violations (corrected intraoperative) and 2 instrument prominences which required implant removal. The mean preoperative/postoperative cobb angles were 78.5 degrees/27.8 degrees and the mean preoperative/postoperative kyphosis angles were 57.2 degrees/32.5 degrees, respectively. The loss of correction was 1.2 degrees. There were no neurological deficits and no instrument failures.
ILS are safe and effective when used in deformity correction. However, biomechanical studies and randomized controlled trials are needed to conclude whether ILS will be considered a first-line technique, or will remain a technique for salvage situations.</abstract><cop>United States</cop><pmid>23429307</pmid><doi>10.1097/BSD.0b013e31828804a7</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1536-0652 |
ispartof | Journal of spinal disorders & techniques, 2013-12, Vol.26 (8), p.E299-E305 |
issn | 1536-0652 1539-2465 |
language | eng |
recordid | cdi_proquest_miscellaneous_1459150025 |
source | MEDLINE; Journals@Ovid Ovid Autoload |
subjects | Adolescent Adult Bone Screws Child Child, Preschool Female Humans Intraoperative Care Kyphosis - diagnostic imaging Kyphosis - surgery Male Middle Aged Postoperative Care Radiography Scoliosis - diagnostic imaging Scoliosis - surgery |
title | The use of intralaminar screws in patients with spinal deformity |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T16%3A39%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20use%20of%20intralaminar%20screws%20in%20patients%20with%20spinal%20deformity&rft.jtitle=Journal%20of%20spinal%20disorders%20&%20techniques&rft.au=Kose,%20Kamil%20C&rft.date=2013-12-01&rft.volume=26&rft.issue=8&rft.spage=E299&rft.epage=E305&rft.pages=E299-E305&rft.issn=1536-0652&rft.eissn=1539-2465&rft_id=info:doi/10.1097/BSD.0b013e31828804a7&rft_dat=%3Cproquest_cross%3E1459150025%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1459150025&rft_id=info:pmid/23429307&rfr_iscdi=true |