Lithiasis size estimation variability depending on image technical methodology

The lithiasic size is a determining factor in selecting the most suitable treatment, surgical or medical. However, the method for obtaining a reliable lithiasic size is not standardized. Our objetives are to determine the differences between the estimated lithiasic sizes shown by plain radiography t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Urolithiasis 2013-11, Vol.41 (6), p.517-522
Hauptverfasser: Argüelles Salido, Enrique, Aguilar García, Jesús, Lozano-Blasco, Jose María, Subirá Rios, Jorge, Beardo Villar, Pastora, Campoy-Martínez, Pedro, Medina-López, Rafael A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The lithiasic size is a determining factor in selecting the most suitable treatment, surgical or medical. However, the method for obtaining a reliable lithiasic size is not standardized. Our objetives are to determine the differences between the estimated lithiasic sizes shown by plain radiography test and by computerized axial tomography (CT) scan (using different techniques) in relation to the actual size, and to establish which is the ideal type of imaging for this purpose. We present an in vitro model with lithiasis obtained in cooperation with four centers. Inclusion criteria: lithiasis >0.5 cm, intact, and visible via simple radiography. A sample of 245 lithiases was obtained, with 87 rejected as they did not fulfill the inclusion criteria. Initially the three main actual diameters of each lithiasis were measured with a calibrator, then a plain X-ray and a CT scan were taken of the samples to determine the surface size in cm 2 for simple radiography; surface size and volume in cm 3 for CT scan, in bone window and soft tissue (Toshiba Aquillion 64, sections of 0.5 mm, 120 Kv, 250 mA). The tomographic area was calculated by employing the formula recommended by the European Association of Urology and scanner software. The actual, radiographic and tomographic measurements were taken by three different researchers who were unaware of the results obtained by the each other. The statistics program IBM SPSS Statistics ® 19 was used. Differences were analyzed using the Wilcoxon sign test. The bone window CT scan slightly overestimated the actual lithiasic size (0.12 vs. 0.17 cm 3 ), while in soft tissue window the actual volume was practically doubled (0.12 vs. 0.21 cm 3 ) ( p  
ISSN:2194-7228
2194-7236
DOI:10.1007/s00240-013-0597-0