Indoor air measurement campaign in Helsinki, Finland 1999 – the effect of outdoor air pollution on indoor air

Wintertime indoor and outdoor particle size distributions were studied in an office building near Helsinki downtown by measuring the particle size distributions with two similar differential mobility particle sizer systems (DMPS). Measurements were made simultaneously at two places; on the rooftop o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Atmospheric environment (1994) 2001, Vol.35 (8), p.1465-1477
Hauptverfasser: K. Koponen, Ismo, Asmi, Ari, Keronen, Petri, Puhto, Katri, Kulmala, Markku
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1477
container_issue 8
container_start_page 1465
container_title Atmospheric environment (1994)
container_volume 35
creator K. Koponen, Ismo
Asmi, Ari
Keronen, Petri
Puhto, Katri
Kulmala, Markku
description Wintertime indoor and outdoor particle size distributions were studied in an office building near Helsinki downtown by measuring the particle size distributions with two similar differential mobility particle sizer systems (DMPS). Measurements were made simultaneously at two places; on the rooftop of a building (30 m above the ground level) in front of a ventilation system corresponding to outdoor concentration, and an office room (first floor). The ventilation rate was also continuously monitored. Indoor particle concentrations were observed to vary from 500 to 10 4 cm −3 with a high dependence on the outdoor concentrations. This indicates that in this scenario, indoor particles are mainly of outdoor origin. Effects of ventilation rates on indoor air particle concentrations and several inorganic gases were studied. We found that ventilation had a strong influence on indoor particle and gas concentrations. I/O (indoor/outdoor) ratio in different in different particle size classes.
doi_str_mv 10.1016/S1352-2310(00)00338-1
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_14578876</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1352231000003381</els_id><sourcerecordid>14578876</sourcerecordid><originalsourceid>FETCH-LOGICAL-c338t-eea8adec4da5f957aa442c5b6a98e3c0ba8562a4f91574897474ce866e1bdfbe3</originalsourceid><addsrcrecordid>eNqFkMFKxDAURYMoOI5-gpCVKFhN2rRJVyKD4wwILtR1SNNXjbbJmLSCO__BP_RLTB3HrfDgPR73Xi4HoUNKziihxfkdzfI0STNKjgk5ISTLREK30IQKniWpYGw73hvJLtoL4ZlEFS_5BLmlrZ3zWBmPO1Bh8NCB7bFW3UqZR4uNxQtog7Ev5hTPjW2VrTEtyxJ_fXzi_gkwNA3oHrsGu6H_C1u5th164yx2Y8jmv492GtUGOPjdU_Qwv7qfLZKb2-vl7PIm0bF9nwAooWrQrFZ5U-ZcKcZSnVeFKgVkmlRK5EWqWFPSnDNRcsaZBlEUQKu6qSCboqN17sq71wFCLzsTNLSxPrghSMpyLgQvojBfC7V3IXho5MqbTvl3SYkc8cofvHJkJ8k4saCk0Xex9kU48GbAy6ANWA218RGHrJ35J-EbPpaDjQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>14578876</pqid></control><display><type>article</type><title>Indoor air measurement campaign in Helsinki, Finland 1999 – the effect of outdoor air pollution on indoor air</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>K. Koponen, Ismo ; Asmi, Ari ; Keronen, Petri ; Puhto, Katri ; Kulmala, Markku</creator><creatorcontrib>K. Koponen, Ismo ; Asmi, Ari ; Keronen, Petri ; Puhto, Katri ; Kulmala, Markku</creatorcontrib><description>Wintertime indoor and outdoor particle size distributions were studied in an office building near Helsinki downtown by measuring the particle size distributions with two similar differential mobility particle sizer systems (DMPS). Measurements were made simultaneously at two places; on the rooftop of a building (30 m above the ground level) in front of a ventilation system corresponding to outdoor concentration, and an office room (first floor). The ventilation rate was also continuously monitored. Indoor particle concentrations were observed to vary from 500 to 10 4 cm −3 with a high dependence on the outdoor concentrations. This indicates that in this scenario, indoor particles are mainly of outdoor origin. Effects of ventilation rates on indoor air particle concentrations and several inorganic gases were studied. We found that ventilation had a strong influence on indoor particle and gas concentrations. I/O (indoor/outdoor) ratio in different in different particle size classes.</description><identifier>ISSN: 1352-2310</identifier><identifier>EISSN: 1873-2844</identifier><identifier>DOI: 10.1016/S1352-2310(00)00338-1</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Filtration ; I/O ratios ; Indoor aerosols ; Particle size distributions ; Ultrafine particles ; Ventilation</subject><ispartof>Atmospheric environment (1994), 2001, Vol.35 (8), p.1465-1477</ispartof><rights>2001 Elsevier Science B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c338t-eea8adec4da5f957aa442c5b6a98e3c0ba8562a4f91574897474ce866e1bdfbe3</citedby><cites>FETCH-LOGICAL-c338t-eea8adec4da5f957aa442c5b6a98e3c0ba8562a4f91574897474ce866e1bdfbe3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S1352-2310(00)00338-1$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,4022,27922,27923,27924,45994</link.rule.ids></links><search><creatorcontrib>K. Koponen, Ismo</creatorcontrib><creatorcontrib>Asmi, Ari</creatorcontrib><creatorcontrib>Keronen, Petri</creatorcontrib><creatorcontrib>Puhto, Katri</creatorcontrib><creatorcontrib>Kulmala, Markku</creatorcontrib><title>Indoor air measurement campaign in Helsinki, Finland 1999 – the effect of outdoor air pollution on indoor air</title><title>Atmospheric environment (1994)</title><description>Wintertime indoor and outdoor particle size distributions were studied in an office building near Helsinki downtown by measuring the particle size distributions with two similar differential mobility particle sizer systems (DMPS). Measurements were made simultaneously at two places; on the rooftop of a building (30 m above the ground level) in front of a ventilation system corresponding to outdoor concentration, and an office room (first floor). The ventilation rate was also continuously monitored. Indoor particle concentrations were observed to vary from 500 to 10 4 cm −3 with a high dependence on the outdoor concentrations. This indicates that in this scenario, indoor particles are mainly of outdoor origin. Effects of ventilation rates on indoor air particle concentrations and several inorganic gases were studied. We found that ventilation had a strong influence on indoor particle and gas concentrations. I/O (indoor/outdoor) ratio in different in different particle size classes.</description><subject>Filtration</subject><subject>I/O ratios</subject><subject>Indoor aerosols</subject><subject>Particle size distributions</subject><subject>Ultrafine particles</subject><subject>Ventilation</subject><issn>1352-2310</issn><issn>1873-2844</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><recordid>eNqFkMFKxDAURYMoOI5-gpCVKFhN2rRJVyKD4wwILtR1SNNXjbbJmLSCO__BP_RLTB3HrfDgPR73Xi4HoUNKziihxfkdzfI0STNKjgk5ISTLREK30IQKniWpYGw73hvJLtoL4ZlEFS_5BLmlrZ3zWBmPO1Bh8NCB7bFW3UqZR4uNxQtog7Ev5hTPjW2VrTEtyxJ_fXzi_gkwNA3oHrsGu6H_C1u5th164yx2Y8jmv492GtUGOPjdU_Qwv7qfLZKb2-vl7PIm0bF9nwAooWrQrFZ5U-ZcKcZSnVeFKgVkmlRK5EWqWFPSnDNRcsaZBlEUQKu6qSCboqN17sq71wFCLzsTNLSxPrghSMpyLgQvojBfC7V3IXho5MqbTvl3SYkc8cofvHJkJ8k4saCk0Xex9kU48GbAy6ANWA218RGHrJ35J-EbPpaDjQ</recordid><startdate>2001</startdate><enddate>2001</enddate><creator>K. Koponen, Ismo</creator><creator>Asmi, Ari</creator><creator>Keronen, Petri</creator><creator>Puhto, Katri</creator><creator>Kulmala, Markku</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope></search><sort><creationdate>2001</creationdate><title>Indoor air measurement campaign in Helsinki, Finland 1999 – the effect of outdoor air pollution on indoor air</title><author>K. Koponen, Ismo ; Asmi, Ari ; Keronen, Petri ; Puhto, Katri ; Kulmala, Markku</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c338t-eea8adec4da5f957aa442c5b6a98e3c0ba8562a4f91574897474ce866e1bdfbe3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Filtration</topic><topic>I/O ratios</topic><topic>Indoor aerosols</topic><topic>Particle size distributions</topic><topic>Ultrafine particles</topic><topic>Ventilation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>K. Koponen, Ismo</creatorcontrib><creatorcontrib>Asmi, Ari</creatorcontrib><creatorcontrib>Keronen, Petri</creatorcontrib><creatorcontrib>Puhto, Katri</creatorcontrib><creatorcontrib>Kulmala, Markku</creatorcontrib><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><jtitle>Atmospheric environment (1994)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>K. Koponen, Ismo</au><au>Asmi, Ari</au><au>Keronen, Petri</au><au>Puhto, Katri</au><au>Kulmala, Markku</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Indoor air measurement campaign in Helsinki, Finland 1999 – the effect of outdoor air pollution on indoor air</atitle><jtitle>Atmospheric environment (1994)</jtitle><date>2001</date><risdate>2001</risdate><volume>35</volume><issue>8</issue><spage>1465</spage><epage>1477</epage><pages>1465-1477</pages><issn>1352-2310</issn><eissn>1873-2844</eissn><abstract>Wintertime indoor and outdoor particle size distributions were studied in an office building near Helsinki downtown by measuring the particle size distributions with two similar differential mobility particle sizer systems (DMPS). Measurements were made simultaneously at two places; on the rooftop of a building (30 m above the ground level) in front of a ventilation system corresponding to outdoor concentration, and an office room (first floor). The ventilation rate was also continuously monitored. Indoor particle concentrations were observed to vary from 500 to 10 4 cm −3 with a high dependence on the outdoor concentrations. This indicates that in this scenario, indoor particles are mainly of outdoor origin. Effects of ventilation rates on indoor air particle concentrations and several inorganic gases were studied. We found that ventilation had a strong influence on indoor particle and gas concentrations. I/O (indoor/outdoor) ratio in different in different particle size classes.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/S1352-2310(00)00338-1</doi><tpages>13</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1352-2310
ispartof Atmospheric environment (1994), 2001, Vol.35 (8), p.1465-1477
issn 1352-2310
1873-2844
language eng
recordid cdi_proquest_miscellaneous_14578876
source ScienceDirect Journals (5 years ago - present)
subjects Filtration
I/O ratios
Indoor aerosols
Particle size distributions
Ultrafine particles
Ventilation
title Indoor air measurement campaign in Helsinki, Finland 1999 – the effect of outdoor air pollution on indoor air
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T14%3A42%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Indoor%20air%20measurement%20campaign%20in%20Helsinki,%20Finland%201999%20%E2%80%93%20the%20effect%20of%20outdoor%20air%20pollution%20on%20indoor%20air&rft.jtitle=Atmospheric%20environment%20(1994)&rft.au=K.%20Koponen,%20Ismo&rft.date=2001&rft.volume=35&rft.issue=8&rft.spage=1465&rft.epage=1477&rft.pages=1465-1477&rft.issn=1352-2310&rft.eissn=1873-2844&rft_id=info:doi/10.1016/S1352-2310(00)00338-1&rft_dat=%3Cproquest_cross%3E14578876%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=14578876&rft_id=info:pmid/&rft_els_id=S1352231000003381&rfr_iscdi=true