Indoor air measurement campaign in Helsinki, Finland 1999 – the effect of outdoor air pollution on indoor air
Wintertime indoor and outdoor particle size distributions were studied in an office building near Helsinki downtown by measuring the particle size distributions with two similar differential mobility particle sizer systems (DMPS). Measurements were made simultaneously at two places; on the rooftop o...
Gespeichert in:
Veröffentlicht in: | Atmospheric environment (1994) 2001, Vol.35 (8), p.1465-1477 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1477 |
---|---|
container_issue | 8 |
container_start_page | 1465 |
container_title | Atmospheric environment (1994) |
container_volume | 35 |
creator | K. Koponen, Ismo Asmi, Ari Keronen, Petri Puhto, Katri Kulmala, Markku |
description | Wintertime indoor and outdoor particle size distributions were studied in an office building near Helsinki downtown by measuring the particle size distributions with two similar differential mobility particle sizer systems (DMPS). Measurements were made simultaneously at two places; on the rooftop of a building (30 m above the ground level) in front of a ventilation system corresponding to outdoor concentration, and an office room (first floor). The ventilation rate was also continuously monitored. Indoor particle concentrations were observed to vary from 500 to
10
4
cm
−3
with a high dependence on the outdoor concentrations. This indicates that in this scenario, indoor particles are mainly of outdoor origin. Effects of ventilation rates on indoor air particle concentrations and several inorganic gases were studied. We found that ventilation had a strong influence on indoor particle and gas concentrations. I/O (indoor/outdoor) ratio in different in different particle size classes. |
doi_str_mv | 10.1016/S1352-2310(00)00338-1 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_14578876</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1352231000003381</els_id><sourcerecordid>14578876</sourcerecordid><originalsourceid>FETCH-LOGICAL-c338t-eea8adec4da5f957aa442c5b6a98e3c0ba8562a4f91574897474ce866e1bdfbe3</originalsourceid><addsrcrecordid>eNqFkMFKxDAURYMoOI5-gpCVKFhN2rRJVyKD4wwILtR1SNNXjbbJmLSCO__BP_RLTB3HrfDgPR73Xi4HoUNKziihxfkdzfI0STNKjgk5ISTLREK30IQKniWpYGw73hvJLtoL4ZlEFS_5BLmlrZ3zWBmPO1Bh8NCB7bFW3UqZR4uNxQtog7Ev5hTPjW2VrTEtyxJ_fXzi_gkwNA3oHrsGu6H_C1u5th164yx2Y8jmv492GtUGOPjdU_Qwv7qfLZKb2-vl7PIm0bF9nwAooWrQrFZ5U-ZcKcZSnVeFKgVkmlRK5EWqWFPSnDNRcsaZBlEUQKu6qSCboqN17sq71wFCLzsTNLSxPrghSMpyLgQvojBfC7V3IXho5MqbTvl3SYkc8cofvHJkJ8k4saCk0Xex9kU48GbAy6ANWA218RGHrJ35J-EbPpaDjQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>14578876</pqid></control><display><type>article</type><title>Indoor air measurement campaign in Helsinki, Finland 1999 – the effect of outdoor air pollution on indoor air</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>K. Koponen, Ismo ; Asmi, Ari ; Keronen, Petri ; Puhto, Katri ; Kulmala, Markku</creator><creatorcontrib>K. Koponen, Ismo ; Asmi, Ari ; Keronen, Petri ; Puhto, Katri ; Kulmala, Markku</creatorcontrib><description>Wintertime indoor and outdoor particle size distributions were studied in an office building near Helsinki downtown by measuring the particle size distributions with two similar differential mobility particle sizer systems (DMPS). Measurements were made simultaneously at two places; on the rooftop of a building (30 m above the ground level) in front of a ventilation system corresponding to outdoor concentration, and an office room (first floor). The ventilation rate was also continuously monitored. Indoor particle concentrations were observed to vary from 500 to
10
4
cm
−3
with a high dependence on the outdoor concentrations. This indicates that in this scenario, indoor particles are mainly of outdoor origin. Effects of ventilation rates on indoor air particle concentrations and several inorganic gases were studied. We found that ventilation had a strong influence on indoor particle and gas concentrations. I/O (indoor/outdoor) ratio in different in different particle size classes.</description><identifier>ISSN: 1352-2310</identifier><identifier>EISSN: 1873-2844</identifier><identifier>DOI: 10.1016/S1352-2310(00)00338-1</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Filtration ; I/O ratios ; Indoor aerosols ; Particle size distributions ; Ultrafine particles ; Ventilation</subject><ispartof>Atmospheric environment (1994), 2001, Vol.35 (8), p.1465-1477</ispartof><rights>2001 Elsevier Science B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c338t-eea8adec4da5f957aa442c5b6a98e3c0ba8562a4f91574897474ce866e1bdfbe3</citedby><cites>FETCH-LOGICAL-c338t-eea8adec4da5f957aa442c5b6a98e3c0ba8562a4f91574897474ce866e1bdfbe3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S1352-2310(00)00338-1$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,4022,27922,27923,27924,45994</link.rule.ids></links><search><creatorcontrib>K. Koponen, Ismo</creatorcontrib><creatorcontrib>Asmi, Ari</creatorcontrib><creatorcontrib>Keronen, Petri</creatorcontrib><creatorcontrib>Puhto, Katri</creatorcontrib><creatorcontrib>Kulmala, Markku</creatorcontrib><title>Indoor air measurement campaign in Helsinki, Finland 1999 – the effect of outdoor air pollution on indoor air</title><title>Atmospheric environment (1994)</title><description>Wintertime indoor and outdoor particle size distributions were studied in an office building near Helsinki downtown by measuring the particle size distributions with two similar differential mobility particle sizer systems (DMPS). Measurements were made simultaneously at two places; on the rooftop of a building (30 m above the ground level) in front of a ventilation system corresponding to outdoor concentration, and an office room (first floor). The ventilation rate was also continuously monitored. Indoor particle concentrations were observed to vary from 500 to
10
4
cm
−3
with a high dependence on the outdoor concentrations. This indicates that in this scenario, indoor particles are mainly of outdoor origin. Effects of ventilation rates on indoor air particle concentrations and several inorganic gases were studied. We found that ventilation had a strong influence on indoor particle and gas concentrations. I/O (indoor/outdoor) ratio in different in different particle size classes.</description><subject>Filtration</subject><subject>I/O ratios</subject><subject>Indoor aerosols</subject><subject>Particle size distributions</subject><subject>Ultrafine particles</subject><subject>Ventilation</subject><issn>1352-2310</issn><issn>1873-2844</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><recordid>eNqFkMFKxDAURYMoOI5-gpCVKFhN2rRJVyKD4wwILtR1SNNXjbbJmLSCO__BP_RLTB3HrfDgPR73Xi4HoUNKziihxfkdzfI0STNKjgk5ISTLREK30IQKniWpYGw73hvJLtoL4ZlEFS_5BLmlrZ3zWBmPO1Bh8NCB7bFW3UqZR4uNxQtog7Ev5hTPjW2VrTEtyxJ_fXzi_gkwNA3oHrsGu6H_C1u5th164yx2Y8jmv492GtUGOPjdU_Qwv7qfLZKb2-vl7PIm0bF9nwAooWrQrFZ5U-ZcKcZSnVeFKgVkmlRK5EWqWFPSnDNRcsaZBlEUQKu6qSCboqN17sq71wFCLzsTNLSxPrghSMpyLgQvojBfC7V3IXho5MqbTvl3SYkc8cofvHJkJ8k4saCk0Xex9kU48GbAy6ANWA218RGHrJ35J-EbPpaDjQ</recordid><startdate>2001</startdate><enddate>2001</enddate><creator>K. Koponen, Ismo</creator><creator>Asmi, Ari</creator><creator>Keronen, Petri</creator><creator>Puhto, Katri</creator><creator>Kulmala, Markku</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope></search><sort><creationdate>2001</creationdate><title>Indoor air measurement campaign in Helsinki, Finland 1999 – the effect of outdoor air pollution on indoor air</title><author>K. Koponen, Ismo ; Asmi, Ari ; Keronen, Petri ; Puhto, Katri ; Kulmala, Markku</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c338t-eea8adec4da5f957aa442c5b6a98e3c0ba8562a4f91574897474ce866e1bdfbe3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Filtration</topic><topic>I/O ratios</topic><topic>Indoor aerosols</topic><topic>Particle size distributions</topic><topic>Ultrafine particles</topic><topic>Ventilation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>K. Koponen, Ismo</creatorcontrib><creatorcontrib>Asmi, Ari</creatorcontrib><creatorcontrib>Keronen, Petri</creatorcontrib><creatorcontrib>Puhto, Katri</creatorcontrib><creatorcontrib>Kulmala, Markku</creatorcontrib><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><jtitle>Atmospheric environment (1994)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>K. Koponen, Ismo</au><au>Asmi, Ari</au><au>Keronen, Petri</au><au>Puhto, Katri</au><au>Kulmala, Markku</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Indoor air measurement campaign in Helsinki, Finland 1999 – the effect of outdoor air pollution on indoor air</atitle><jtitle>Atmospheric environment (1994)</jtitle><date>2001</date><risdate>2001</risdate><volume>35</volume><issue>8</issue><spage>1465</spage><epage>1477</epage><pages>1465-1477</pages><issn>1352-2310</issn><eissn>1873-2844</eissn><abstract>Wintertime indoor and outdoor particle size distributions were studied in an office building near Helsinki downtown by measuring the particle size distributions with two similar differential mobility particle sizer systems (DMPS). Measurements were made simultaneously at two places; on the rooftop of a building (30 m above the ground level) in front of a ventilation system corresponding to outdoor concentration, and an office room (first floor). The ventilation rate was also continuously monitored. Indoor particle concentrations were observed to vary from 500 to
10
4
cm
−3
with a high dependence on the outdoor concentrations. This indicates that in this scenario, indoor particles are mainly of outdoor origin. Effects of ventilation rates on indoor air particle concentrations and several inorganic gases were studied. We found that ventilation had a strong influence on indoor particle and gas concentrations. I/O (indoor/outdoor) ratio in different in different particle size classes.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/S1352-2310(00)00338-1</doi><tpages>13</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1352-2310 |
ispartof | Atmospheric environment (1994), 2001, Vol.35 (8), p.1465-1477 |
issn | 1352-2310 1873-2844 |
language | eng |
recordid | cdi_proquest_miscellaneous_14578876 |
source | ScienceDirect Journals (5 years ago - present) |
subjects | Filtration I/O ratios Indoor aerosols Particle size distributions Ultrafine particles Ventilation |
title | Indoor air measurement campaign in Helsinki, Finland 1999 – the effect of outdoor air pollution on indoor air |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T14%3A42%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Indoor%20air%20measurement%20campaign%20in%20Helsinki,%20Finland%201999%20%E2%80%93%20the%20effect%20of%20outdoor%20air%20pollution%20on%20indoor%20air&rft.jtitle=Atmospheric%20environment%20(1994)&rft.au=K.%20Koponen,%20Ismo&rft.date=2001&rft.volume=35&rft.issue=8&rft.spage=1465&rft.epage=1477&rft.pages=1465-1477&rft.issn=1352-2310&rft.eissn=1873-2844&rft_id=info:doi/10.1016/S1352-2310(00)00338-1&rft_dat=%3Cproquest_cross%3E14578876%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=14578876&rft_id=info:pmid/&rft_els_id=S1352231000003381&rfr_iscdi=true |