Microfabricated suspended island platform for the measurement of in-plane thermal conductivity of thin films and nanostructured materials with consideration of contact resistance

A technique based on suspended islands is described to measure the in-plane thermal conductivity of thin films and nano-structured materials, and is also employed for measurements of several samples with a single measurement platform. Using systematic steps for measurements, the characterization of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 2013-10, Vol.84 (10), p.105003-105003
Hauptverfasser: Alaie, Seyedhamidreza, Goettler, Drew F, Abbas, Khawar, Su, Mehmet F, Reinke, Charles M, El-Kady, Ihab, Leseman, Zayd C
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 105003
container_issue 10
container_start_page 105003
container_title Review of scientific instruments
container_volume 84
creator Alaie, Seyedhamidreza
Goettler, Drew F
Abbas, Khawar
Su, Mehmet F
Reinke, Charles M
El-Kady, Ihab
Leseman, Zayd C
description A technique based on suspended islands is described to measure the in-plane thermal conductivity of thin films and nano-structured materials, and is also employed for measurements of several samples with a single measurement platform. Using systematic steps for measurements, the characterization of the thermal resistances of a sample and its contacts are studied. The calibration of the contacts in this method is independent of the geometry, size, materials, and uniformity of contacts. To verify the technique, two different Si samples with different thicknesses and two samples of the same SiN(x) wafer are characterized on a single device. One of the Si samples is also characterized by another technique, which verifies the current results. Characterization of the two SiN(x) samples taken from the same wafer showed less than 1% difference in the measured thermal conductivities, indicating the precision of the method. Additionally, one of the SiN(x) samples is characterized and then demounted, remounted, and characterized for a second time. The comparison showed the change in the thermal resistance of the contact in multiple measurements could be as small as 0.2 K/μW, if a similar sample is used.
doi_str_mv 10.1063/1.4824076
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1449276655</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1449276655</sourcerecordid><originalsourceid>FETCH-LOGICAL-c285t-d2be2329f9519954847d1a40005f391dc6043cc6451dac87e2db3cf1db28ddd93</originalsourceid><addsrcrecordid>eNo9kctOHDEQRa0oiJkAi_xA5GWyaPCrX8sIQYI0iA2sW267rHHUdk9c7kT8Fl-IWzNJLVwl-9QtuS4hnzm75qyRN_xadUKxtvlAtpx1fdU2Qn4kW8akqppWdRvyCfEXK1Fzfk42QvFO8FptydujN2l2ekze6AyW4oIHiLZUHicdLT1MOrs5BVoOmvdAA2hcEgSImc6O-lgVJML6loKeqJmjXUz2f3x-XYG895E6PwWkq17UccacClFELA1lavJ6QvrX5_3ajN5C0tnPce0uF1mbTBOgx6yjgUty5goPV6d8QV7u755vf1a7px8Pt993lRFdnSsrRhBS9K6ved_XqlOt5VqtO3Cy59Y0TEljGlVzq03XgrCjNI7bUXTW2l5ekK9H3UOafy-AeQgeDUzrZ-cFB65UL9qmqeuCfjuiZZeICdxwSD7o9DpwNqwWDXw4WVTYLyfZZQxg_5P_PJHvjsqQtw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1449276655</pqid></control><display><type>article</type><title>Microfabricated suspended island platform for the measurement of in-plane thermal conductivity of thin films and nanostructured materials with consideration of contact resistance</title><source>AIP Journals Complete</source><source>AIP Digital Archive</source><source>Alma/SFX Local Collection</source><creator>Alaie, Seyedhamidreza ; Goettler, Drew F ; Abbas, Khawar ; Su, Mehmet F ; Reinke, Charles M ; El-Kady, Ihab ; Leseman, Zayd C</creator><creatorcontrib>Alaie, Seyedhamidreza ; Goettler, Drew F ; Abbas, Khawar ; Su, Mehmet F ; Reinke, Charles M ; El-Kady, Ihab ; Leseman, Zayd C</creatorcontrib><description>A technique based on suspended islands is described to measure the in-plane thermal conductivity of thin films and nano-structured materials, and is also employed for measurements of several samples with a single measurement platform. Using systematic steps for measurements, the characterization of the thermal resistances of a sample and its contacts are studied. The calibration of the contacts in this method is independent of the geometry, size, materials, and uniformity of contacts. To verify the technique, two different Si samples with different thicknesses and two samples of the same SiN(x) wafer are characterized on a single device. One of the Si samples is also characterized by another technique, which verifies the current results. Characterization of the two SiN(x) samples taken from the same wafer showed less than 1% difference in the measured thermal conductivities, indicating the precision of the method. Additionally, one of the SiN(x) samples is characterized and then demounted, remounted, and characterized for a second time. The comparison showed the change in the thermal resistance of the contact in multiple measurements could be as small as 0.2 K/μW, if a similar sample is used.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.4824076</identifier><identifier>PMID: 24182154</identifier><language>eng</language><publisher>United States</publisher><ispartof>Review of scientific instruments, 2013-10, Vol.84 (10), p.105003-105003</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c285t-d2be2329f9519954847d1a40005f391dc6043cc6451dac87e2db3cf1db28ddd93</citedby><cites>FETCH-LOGICAL-c285t-d2be2329f9519954847d1a40005f391dc6043cc6451dac87e2db3cf1db28ddd93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24182154$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Alaie, Seyedhamidreza</creatorcontrib><creatorcontrib>Goettler, Drew F</creatorcontrib><creatorcontrib>Abbas, Khawar</creatorcontrib><creatorcontrib>Su, Mehmet F</creatorcontrib><creatorcontrib>Reinke, Charles M</creatorcontrib><creatorcontrib>El-Kady, Ihab</creatorcontrib><creatorcontrib>Leseman, Zayd C</creatorcontrib><title>Microfabricated suspended island platform for the measurement of in-plane thermal conductivity of thin films and nanostructured materials with consideration of contact resistance</title><title>Review of scientific instruments</title><addtitle>Rev Sci Instrum</addtitle><description>A technique based on suspended islands is described to measure the in-plane thermal conductivity of thin films and nano-structured materials, and is also employed for measurements of several samples with a single measurement platform. Using systematic steps for measurements, the characterization of the thermal resistances of a sample and its contacts are studied. The calibration of the contacts in this method is independent of the geometry, size, materials, and uniformity of contacts. To verify the technique, two different Si samples with different thicknesses and two samples of the same SiN(x) wafer are characterized on a single device. One of the Si samples is also characterized by another technique, which verifies the current results. Characterization of the two SiN(x) samples taken from the same wafer showed less than 1% difference in the measured thermal conductivities, indicating the precision of the method. Additionally, one of the SiN(x) samples is characterized and then demounted, remounted, and characterized for a second time. The comparison showed the change in the thermal resistance of the contact in multiple measurements could be as small as 0.2 K/μW, if a similar sample is used.</description><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNo9kctOHDEQRa0oiJkAi_xA5GWyaPCrX8sIQYI0iA2sW267rHHUdk9c7kT8Fl-IWzNJLVwl-9QtuS4hnzm75qyRN_xadUKxtvlAtpx1fdU2Qn4kW8akqppWdRvyCfEXK1Fzfk42QvFO8FptydujN2l2ekze6AyW4oIHiLZUHicdLT1MOrs5BVoOmvdAA2hcEgSImc6O-lgVJML6loKeqJmjXUz2f3x-XYG895E6PwWkq17UccacClFELA1lavJ6QvrX5_3ajN5C0tnPce0uF1mbTBOgx6yjgUty5goPV6d8QV7u755vf1a7px8Pt993lRFdnSsrRhBS9K6ved_XqlOt5VqtO3Cy59Y0TEljGlVzq03XgrCjNI7bUXTW2l5ekK9H3UOafy-AeQgeDUzrZ-cFB65UL9qmqeuCfjuiZZeICdxwSD7o9DpwNqwWDXw4WVTYLyfZZQxg_5P_PJHvjsqQtw</recordid><startdate>201310</startdate><enddate>201310</enddate><creator>Alaie, Seyedhamidreza</creator><creator>Goettler, Drew F</creator><creator>Abbas, Khawar</creator><creator>Su, Mehmet F</creator><creator>Reinke, Charles M</creator><creator>El-Kady, Ihab</creator><creator>Leseman, Zayd C</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201310</creationdate><title>Microfabricated suspended island platform for the measurement of in-plane thermal conductivity of thin films and nanostructured materials with consideration of contact resistance</title><author>Alaie, Seyedhamidreza ; Goettler, Drew F ; Abbas, Khawar ; Su, Mehmet F ; Reinke, Charles M ; El-Kady, Ihab ; Leseman, Zayd C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c285t-d2be2329f9519954847d1a40005f391dc6043cc6451dac87e2db3cf1db28ddd93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Alaie, Seyedhamidreza</creatorcontrib><creatorcontrib>Goettler, Drew F</creatorcontrib><creatorcontrib>Abbas, Khawar</creatorcontrib><creatorcontrib>Su, Mehmet F</creatorcontrib><creatorcontrib>Reinke, Charles M</creatorcontrib><creatorcontrib>El-Kady, Ihab</creatorcontrib><creatorcontrib>Leseman, Zayd C</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Alaie, Seyedhamidreza</au><au>Goettler, Drew F</au><au>Abbas, Khawar</au><au>Su, Mehmet F</au><au>Reinke, Charles M</au><au>El-Kady, Ihab</au><au>Leseman, Zayd C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Microfabricated suspended island platform for the measurement of in-plane thermal conductivity of thin films and nanostructured materials with consideration of contact resistance</atitle><jtitle>Review of scientific instruments</jtitle><addtitle>Rev Sci Instrum</addtitle><date>2013-10</date><risdate>2013</risdate><volume>84</volume><issue>10</issue><spage>105003</spage><epage>105003</epage><pages>105003-105003</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><abstract>A technique based on suspended islands is described to measure the in-plane thermal conductivity of thin films and nano-structured materials, and is also employed for measurements of several samples with a single measurement platform. Using systematic steps for measurements, the characterization of the thermal resistances of a sample and its contacts are studied. The calibration of the contacts in this method is independent of the geometry, size, materials, and uniformity of contacts. To verify the technique, two different Si samples with different thicknesses and two samples of the same SiN(x) wafer are characterized on a single device. One of the Si samples is also characterized by another technique, which verifies the current results. Characterization of the two SiN(x) samples taken from the same wafer showed less than 1% difference in the measured thermal conductivities, indicating the precision of the method. Additionally, one of the SiN(x) samples is characterized and then demounted, remounted, and characterized for a second time. The comparison showed the change in the thermal resistance of the contact in multiple measurements could be as small as 0.2 K/μW, if a similar sample is used.</abstract><cop>United States</cop><pmid>24182154</pmid><doi>10.1063/1.4824076</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of scientific instruments, 2013-10, Vol.84 (10), p.105003-105003
issn 0034-6748
1089-7623
language eng
recordid cdi_proquest_miscellaneous_1449276655
source AIP Journals Complete; AIP Digital Archive; Alma/SFX Local Collection
title Microfabricated suspended island platform for the measurement of in-plane thermal conductivity of thin films and nanostructured materials with consideration of contact resistance
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T02%3A21%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Microfabricated%20suspended%20island%20platform%20for%20the%20measurement%20of%20in-plane%20thermal%20conductivity%20of%20thin%20films%20and%20nanostructured%20materials%20with%20consideration%20of%20contact%20resistance&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Alaie,%20Seyedhamidreza&rft.date=2013-10&rft.volume=84&rft.issue=10&rft.spage=105003&rft.epage=105003&rft.pages=105003-105003&rft.issn=0034-6748&rft.eissn=1089-7623&rft_id=info:doi/10.1063/1.4824076&rft_dat=%3Cproquest_cross%3E1449276655%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1449276655&rft_id=info:pmid/24182154&rfr_iscdi=true