Heterodyne interferometer for absolute amplitude vibration measurements with femtometer sensitivity
A heterodyne interferometer for highly sensitive vibration measurements in the range 100 kHz - 1.3GHz is presented. The interferometer measures absolute amplitude and phase. The signal processing of the setup is analyzed and described in detail to optimize noise suppression. A noise floor of 7.1 fm/...
Gespeichert in:
Veröffentlicht in: | Optics express 2013-08, Vol.21 (17), p.19900-19921 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 19921 |
---|---|
container_issue | 17 |
container_start_page | 19900 |
container_title | Optics express |
container_volume | 21 |
creator | Leirset, Erlend Engan, Helge E Aksnes, Astrid |
description | A heterodyne interferometer for highly sensitive vibration measurements in the range 100 kHz - 1.3GHz is presented. The interferometer measures absolute amplitude and phase. The signal processing of the setup is analyzed and described in detail to optimize noise suppression. A noise floor of 7.1 fm/Hz(1/2) at 21 MHz was achieved experimentally where the bandwidth is the inverse of all time needed for filter settling and signal sampling. To demonstrate the interferometer, measurements up to 220 MHz were performed on arrays of capacitive micromachined ultrasonic transducers (CMUTs). The measurements provided detailed information e.g. about the frequency response, vibration patterns and array uniformity. Such measurements are highly valuable in the design process of ultrasonic transducers. |
doi_str_mv | 10.1364/OE.21.019900 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1443425861</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1443425861</sourcerecordid><originalsourceid>FETCH-LOGICAL-c329t-592254c501587c09b94b00dd16f1d20364822960b93dfa5955e41abb94a0a3713</originalsourceid><addsrcrecordid>eNpNkM1Lw0AQxRdRbK3ePMsePZg6-5Vkj1KqFQq96HnZJBNcyUfd3VT635vSKp7mzfCbB-8RcstgzkQqHzfLOWdzYFoDnJEpAy0TCXl2_k9PyFUInwBMZjq7JBMuGSglsikpVxjR99W-Q-q6Udbj1h5utO49tUXomyEite22cXGokO5c4W10fUdbtGHw2GIXA_128YPW2MbTd8AuuOh2Lu6vyUVtm4A3pzkj78_Lt8UqWW9eXhdP66QUXMdEac6VLBUwlWcl6ELLAqCqWFqzisOYNedcp1BoUdVWaaVQMluMmAUrMiZm5P7ou_X914AhmtaFEpvGdtgPwTApheQqTw_owxEtfR-Cx9psvWut3xsG5lCr2SwNZ-ZY64jfnZyHosXqD_7tUfwAz_hz9g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1443425861</pqid></control><display><type>article</type><title>Heterodyne interferometer for absolute amplitude vibration measurements with femtometer sensitivity</title><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>Leirset, Erlend ; Engan, Helge E ; Aksnes, Astrid</creator><creatorcontrib>Leirset, Erlend ; Engan, Helge E ; Aksnes, Astrid</creatorcontrib><description>A heterodyne interferometer for highly sensitive vibration measurements in the range 100 kHz - 1.3GHz is presented. The interferometer measures absolute amplitude and phase. The signal processing of the setup is analyzed and described in detail to optimize noise suppression. A noise floor of 7.1 fm/Hz(1/2) at 21 MHz was achieved experimentally where the bandwidth is the inverse of all time needed for filter settling and signal sampling. To demonstrate the interferometer, measurements up to 220 MHz were performed on arrays of capacitive micromachined ultrasonic transducers (CMUTs). The measurements provided detailed information e.g. about the frequency response, vibration patterns and array uniformity. Such measurements are highly valuable in the design process of ultrasonic transducers.</description><identifier>ISSN: 1094-4087</identifier><identifier>EISSN: 1094-4087</identifier><identifier>DOI: 10.1364/OE.21.019900</identifier><identifier>PMID: 24105537</identifier><language>eng</language><publisher>United States</publisher><ispartof>Optics express, 2013-08, Vol.21 (17), p.19900-19921</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c329t-592254c501587c09b94b00dd16f1d20364822960b93dfa5955e41abb94a0a3713</citedby><cites>FETCH-LOGICAL-c329t-592254c501587c09b94b00dd16f1d20364822960b93dfa5955e41abb94a0a3713</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,860,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24105537$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Leirset, Erlend</creatorcontrib><creatorcontrib>Engan, Helge E</creatorcontrib><creatorcontrib>Aksnes, Astrid</creatorcontrib><title>Heterodyne interferometer for absolute amplitude vibration measurements with femtometer sensitivity</title><title>Optics express</title><addtitle>Opt Express</addtitle><description>A heterodyne interferometer for highly sensitive vibration measurements in the range 100 kHz - 1.3GHz is presented. The interferometer measures absolute amplitude and phase. The signal processing of the setup is analyzed and described in detail to optimize noise suppression. A noise floor of 7.1 fm/Hz(1/2) at 21 MHz was achieved experimentally where the bandwidth is the inverse of all time needed for filter settling and signal sampling. To demonstrate the interferometer, measurements up to 220 MHz were performed on arrays of capacitive micromachined ultrasonic transducers (CMUTs). The measurements provided detailed information e.g. about the frequency response, vibration patterns and array uniformity. Such measurements are highly valuable in the design process of ultrasonic transducers.</description><issn>1094-4087</issn><issn>1094-4087</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNpNkM1Lw0AQxRdRbK3ePMsePZg6-5Vkj1KqFQq96HnZJBNcyUfd3VT635vSKp7mzfCbB-8RcstgzkQqHzfLOWdzYFoDnJEpAy0TCXl2_k9PyFUInwBMZjq7JBMuGSglsikpVxjR99W-Q-q6Udbj1h5utO49tUXomyEite22cXGokO5c4W10fUdbtGHw2GIXA_128YPW2MbTd8AuuOh2Lu6vyUVtm4A3pzkj78_Lt8UqWW9eXhdP66QUXMdEac6VLBUwlWcl6ELLAqCqWFqzisOYNedcp1BoUdVWaaVQMluMmAUrMiZm5P7ou_X914AhmtaFEpvGdtgPwTApheQqTw_owxEtfR-Cx9psvWut3xsG5lCr2SwNZ-ZY64jfnZyHosXqD_7tUfwAz_hz9g</recordid><startdate>20130826</startdate><enddate>20130826</enddate><creator>Leirset, Erlend</creator><creator>Engan, Helge E</creator><creator>Aksnes, Astrid</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20130826</creationdate><title>Heterodyne interferometer for absolute amplitude vibration measurements with femtometer sensitivity</title><author>Leirset, Erlend ; Engan, Helge E ; Aksnes, Astrid</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c329t-592254c501587c09b94b00dd16f1d20364822960b93dfa5955e41abb94a0a3713</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Leirset, Erlend</creatorcontrib><creatorcontrib>Engan, Helge E</creatorcontrib><creatorcontrib>Aksnes, Astrid</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Leirset, Erlend</au><au>Engan, Helge E</au><au>Aksnes, Astrid</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Heterodyne interferometer for absolute amplitude vibration measurements with femtometer sensitivity</atitle><jtitle>Optics express</jtitle><addtitle>Opt Express</addtitle><date>2013-08-26</date><risdate>2013</risdate><volume>21</volume><issue>17</issue><spage>19900</spage><epage>19921</epage><pages>19900-19921</pages><issn>1094-4087</issn><eissn>1094-4087</eissn><abstract>A heterodyne interferometer for highly sensitive vibration measurements in the range 100 kHz - 1.3GHz is presented. The interferometer measures absolute amplitude and phase. The signal processing of the setup is analyzed and described in detail to optimize noise suppression. A noise floor of 7.1 fm/Hz(1/2) at 21 MHz was achieved experimentally where the bandwidth is the inverse of all time needed for filter settling and signal sampling. To demonstrate the interferometer, measurements up to 220 MHz were performed on arrays of capacitive micromachined ultrasonic transducers (CMUTs). The measurements provided detailed information e.g. about the frequency response, vibration patterns and array uniformity. Such measurements are highly valuable in the design process of ultrasonic transducers.</abstract><cop>United States</cop><pmid>24105537</pmid><doi>10.1364/OE.21.019900</doi><tpages>22</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1094-4087 |
ispartof | Optics express, 2013-08, Vol.21 (17), p.19900-19921 |
issn | 1094-4087 1094-4087 |
language | eng |
recordid | cdi_proquest_miscellaneous_1443425861 |
source | DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection |
title | Heterodyne interferometer for absolute amplitude vibration measurements with femtometer sensitivity |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T12%3A17%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Heterodyne%20interferometer%20for%20absolute%20amplitude%20vibration%20measurements%20with%20femtometer%20sensitivity&rft.jtitle=Optics%20express&rft.au=Leirset,%20Erlend&rft.date=2013-08-26&rft.volume=21&rft.issue=17&rft.spage=19900&rft.epage=19921&rft.pages=19900-19921&rft.issn=1094-4087&rft.eissn=1094-4087&rft_id=info:doi/10.1364/OE.21.019900&rft_dat=%3Cproquest_cross%3E1443425861%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1443425861&rft_id=info:pmid/24105537&rfr_iscdi=true |