Heterodyne interferometer for absolute amplitude vibration measurements with femtometer sensitivity

A heterodyne interferometer for highly sensitive vibration measurements in the range 100 kHz - 1.3GHz is presented. The interferometer measures absolute amplitude and phase. The signal processing of the setup is analyzed and described in detail to optimize noise suppression. A noise floor of 7.1 fm/...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Optics express 2013-08, Vol.21 (17), p.19900-19921
Hauptverfasser: Leirset, Erlend, Engan, Helge E, Aksnes, Astrid
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 19921
container_issue 17
container_start_page 19900
container_title Optics express
container_volume 21
creator Leirset, Erlend
Engan, Helge E
Aksnes, Astrid
description A heterodyne interferometer for highly sensitive vibration measurements in the range 100 kHz - 1.3GHz is presented. The interferometer measures absolute amplitude and phase. The signal processing of the setup is analyzed and described in detail to optimize noise suppression. A noise floor of 7.1 fm/Hz(1/2) at 21 MHz was achieved experimentally where the bandwidth is the inverse of all time needed for filter settling and signal sampling. To demonstrate the interferometer, measurements up to 220 MHz were performed on arrays of capacitive micromachined ultrasonic transducers (CMUTs). The measurements provided detailed information e.g. about the frequency response, vibration patterns and array uniformity. Such measurements are highly valuable in the design process of ultrasonic transducers.
doi_str_mv 10.1364/OE.21.019900
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1443425861</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1443425861</sourcerecordid><originalsourceid>FETCH-LOGICAL-c329t-592254c501587c09b94b00dd16f1d20364822960b93dfa5955e41abb94a0a3713</originalsourceid><addsrcrecordid>eNpNkM1Lw0AQxRdRbK3ePMsePZg6-5Vkj1KqFQq96HnZJBNcyUfd3VT635vSKp7mzfCbB-8RcstgzkQqHzfLOWdzYFoDnJEpAy0TCXl2_k9PyFUInwBMZjq7JBMuGSglsikpVxjR99W-Q-q6Udbj1h5utO49tUXomyEite22cXGokO5c4W10fUdbtGHw2GIXA_128YPW2MbTd8AuuOh2Lu6vyUVtm4A3pzkj78_Lt8UqWW9eXhdP66QUXMdEac6VLBUwlWcl6ELLAqCqWFqzisOYNedcp1BoUdVWaaVQMluMmAUrMiZm5P7ou_X914AhmtaFEpvGdtgPwTApheQqTw_owxEtfR-Cx9psvWut3xsG5lCr2SwNZ-ZY64jfnZyHosXqD_7tUfwAz_hz9g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1443425861</pqid></control><display><type>article</type><title>Heterodyne interferometer for absolute amplitude vibration measurements with femtometer sensitivity</title><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>Leirset, Erlend ; Engan, Helge E ; Aksnes, Astrid</creator><creatorcontrib>Leirset, Erlend ; Engan, Helge E ; Aksnes, Astrid</creatorcontrib><description>A heterodyne interferometer for highly sensitive vibration measurements in the range 100 kHz - 1.3GHz is presented. The interferometer measures absolute amplitude and phase. The signal processing of the setup is analyzed and described in detail to optimize noise suppression. A noise floor of 7.1 fm/Hz(1/2) at 21 MHz was achieved experimentally where the bandwidth is the inverse of all time needed for filter settling and signal sampling. To demonstrate the interferometer, measurements up to 220 MHz were performed on arrays of capacitive micromachined ultrasonic transducers (CMUTs). The measurements provided detailed information e.g. about the frequency response, vibration patterns and array uniformity. Such measurements are highly valuable in the design process of ultrasonic transducers.</description><identifier>ISSN: 1094-4087</identifier><identifier>EISSN: 1094-4087</identifier><identifier>DOI: 10.1364/OE.21.019900</identifier><identifier>PMID: 24105537</identifier><language>eng</language><publisher>United States</publisher><ispartof>Optics express, 2013-08, Vol.21 (17), p.19900-19921</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c329t-592254c501587c09b94b00dd16f1d20364822960b93dfa5955e41abb94a0a3713</citedby><cites>FETCH-LOGICAL-c329t-592254c501587c09b94b00dd16f1d20364822960b93dfa5955e41abb94a0a3713</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,860,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24105537$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Leirset, Erlend</creatorcontrib><creatorcontrib>Engan, Helge E</creatorcontrib><creatorcontrib>Aksnes, Astrid</creatorcontrib><title>Heterodyne interferometer for absolute amplitude vibration measurements with femtometer sensitivity</title><title>Optics express</title><addtitle>Opt Express</addtitle><description>A heterodyne interferometer for highly sensitive vibration measurements in the range 100 kHz - 1.3GHz is presented. The interferometer measures absolute amplitude and phase. The signal processing of the setup is analyzed and described in detail to optimize noise suppression. A noise floor of 7.1 fm/Hz(1/2) at 21 MHz was achieved experimentally where the bandwidth is the inverse of all time needed for filter settling and signal sampling. To demonstrate the interferometer, measurements up to 220 MHz were performed on arrays of capacitive micromachined ultrasonic transducers (CMUTs). The measurements provided detailed information e.g. about the frequency response, vibration patterns and array uniformity. Such measurements are highly valuable in the design process of ultrasonic transducers.</description><issn>1094-4087</issn><issn>1094-4087</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNpNkM1Lw0AQxRdRbK3ePMsePZg6-5Vkj1KqFQq96HnZJBNcyUfd3VT635vSKp7mzfCbB-8RcstgzkQqHzfLOWdzYFoDnJEpAy0TCXl2_k9PyFUInwBMZjq7JBMuGSglsikpVxjR99W-Q-q6Udbj1h5utO49tUXomyEite22cXGokO5c4W10fUdbtGHw2GIXA_128YPW2MbTd8AuuOh2Lu6vyUVtm4A3pzkj78_Lt8UqWW9eXhdP66QUXMdEac6VLBUwlWcl6ELLAqCqWFqzisOYNedcp1BoUdVWaaVQMluMmAUrMiZm5P7ou_X914AhmtaFEpvGdtgPwTApheQqTw_owxEtfR-Cx9psvWut3xsG5lCr2SwNZ-ZY64jfnZyHosXqD_7tUfwAz_hz9g</recordid><startdate>20130826</startdate><enddate>20130826</enddate><creator>Leirset, Erlend</creator><creator>Engan, Helge E</creator><creator>Aksnes, Astrid</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20130826</creationdate><title>Heterodyne interferometer for absolute amplitude vibration measurements with femtometer sensitivity</title><author>Leirset, Erlend ; Engan, Helge E ; Aksnes, Astrid</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c329t-592254c501587c09b94b00dd16f1d20364822960b93dfa5955e41abb94a0a3713</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Leirset, Erlend</creatorcontrib><creatorcontrib>Engan, Helge E</creatorcontrib><creatorcontrib>Aksnes, Astrid</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Leirset, Erlend</au><au>Engan, Helge E</au><au>Aksnes, Astrid</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Heterodyne interferometer for absolute amplitude vibration measurements with femtometer sensitivity</atitle><jtitle>Optics express</jtitle><addtitle>Opt Express</addtitle><date>2013-08-26</date><risdate>2013</risdate><volume>21</volume><issue>17</issue><spage>19900</spage><epage>19921</epage><pages>19900-19921</pages><issn>1094-4087</issn><eissn>1094-4087</eissn><abstract>A heterodyne interferometer for highly sensitive vibration measurements in the range 100 kHz - 1.3GHz is presented. The interferometer measures absolute amplitude and phase. The signal processing of the setup is analyzed and described in detail to optimize noise suppression. A noise floor of 7.1 fm/Hz(1/2) at 21 MHz was achieved experimentally where the bandwidth is the inverse of all time needed for filter settling and signal sampling. To demonstrate the interferometer, measurements up to 220 MHz were performed on arrays of capacitive micromachined ultrasonic transducers (CMUTs). The measurements provided detailed information e.g. about the frequency response, vibration patterns and array uniformity. Such measurements are highly valuable in the design process of ultrasonic transducers.</abstract><cop>United States</cop><pmid>24105537</pmid><doi>10.1364/OE.21.019900</doi><tpages>22</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1094-4087
ispartof Optics express, 2013-08, Vol.21 (17), p.19900-19921
issn 1094-4087
1094-4087
language eng
recordid cdi_proquest_miscellaneous_1443425861
source DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection
title Heterodyne interferometer for absolute amplitude vibration measurements with femtometer sensitivity
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T12%3A17%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Heterodyne%20interferometer%20for%20absolute%20amplitude%20vibration%20measurements%20with%20femtometer%20sensitivity&rft.jtitle=Optics%20express&rft.au=Leirset,%20Erlend&rft.date=2013-08-26&rft.volume=21&rft.issue=17&rft.spage=19900&rft.epage=19921&rft.pages=19900-19921&rft.issn=1094-4087&rft.eissn=1094-4087&rft_id=info:doi/10.1364/OE.21.019900&rft_dat=%3Cproquest_cross%3E1443425861%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1443425861&rft_id=info:pmid/24105537&rfr_iscdi=true