Performance study of a micro-pattern gas detector: leak microstructure
A micro-pattern gas detector named leak microstructure (LM) has been studied. A new chemical electrolytic technique is introduced to make perfect shaped LM needles with very sharp tips, and this method may be developed to make LM array detectors in batches. The experimental results are presented for...
Gespeichert in:
Veröffentlicht in: | Chinese physics C 2012-10, Vol.36 (10), p.985-990 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 990 |
---|---|
container_issue | 10 |
container_start_page | 985 |
container_title | Chinese physics C |
container_volume | 36 |
creator | 章爱武 谢宇广 俞伯祥 安正华 王志刚 蔡啸 孙希磊 石峰 方建 薛镇 吕绮雯 孙丽君 葛永帅 刘颖彪 刘宏邦 郑阳恒 谢一冈 胡涛 周莉 吕军光 |
description | A micro-pattern gas detector named leak microstructure (LM) has been studied. A new chemical electrolytic technique is introduced to make perfect shaped LM needles with very sharp tips, and this method may be developed to make LM array detectors in batches. The experimental results are presented for both a single needle LM detector and a small LM array detector. The gas gain is up to 105 by calculation from the waveform. Good gain stability and uniformity are achieved. The light emission from the needle tip is also measured in Ar/CF4 (95/5) gas mixture. The result shows a promising application for imaging. |
doi_str_mv | 10.1088/1674-1137/36/10/012 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1439781134</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>43918505</cqvip_id><sourcerecordid>1439781134</sourcerecordid><originalsourceid>FETCH-LOGICAL-c308t-b596f01df198cd257cd55f45d9cde354c4c896a82dd479d0d533bd929964c09b3</originalsourceid><addsrcrecordid>eNo9kEtOwzAURS0EEqWwAiZmxiTEjj-xh6gCilQJBjC2XH9KIIlb2xmwFdbCntgCiVp19KSnc67euwBcY3SHkRAl5jUtMCZ1SXiJUYlwdQJmqGK0IIhVp2B2JM7BRUqfCHE6ijOwfHXRh9jp3jiY8mC_YfBQw64xMRRbnbOLPdzoBK3LzuQQ_35_YOv01x5JOQ4mD9FdgjOv2-SuDnMO3h8f3hbLYvXy9Ly4XxWGIJGLNZPcI2w9lsLYitXGMuYps9JYRxg11AjJtaispbW0yDJC1lZWUnJqkFyTObjd525j2A0uZdU1ybi21b0LQ1KYElmL8VM6omSPTnem6LzaxqbT8VthpKbe1NSKmlpRhE_LsbfRujlYH6Hf7Jp-c9TGaCwYYuQfoV5tCQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1439781134</pqid></control><display><type>article</type><title>Performance study of a micro-pattern gas detector: leak microstructure</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><source>Alma/SFX Local Collection</source><creator>章爱武 谢宇广 俞伯祥 安正华 王志刚 蔡啸 孙希磊 石峰 方建 薛镇 吕绮雯 孙丽君 葛永帅 刘颖彪 刘宏邦 郑阳恒 谢一冈 胡涛 周莉 吕军光</creator><creatorcontrib>章爱武 谢宇广 俞伯祥 安正华 王志刚 蔡啸 孙希磊 石峰 方建 薛镇 吕绮雯 孙丽君 葛永帅 刘颖彪 刘宏邦 郑阳恒 谢一冈 胡涛 周莉 吕军光</creatorcontrib><description>A micro-pattern gas detector named leak microstructure (LM) has been studied. A new chemical electrolytic technique is introduced to make perfect shaped LM needles with very sharp tips, and this method may be developed to make LM array detectors in batches. The experimental results are presented for both a single needle LM detector and a small LM array detector. The gas gain is up to 105 by calculation from the waveform. Good gain stability and uniformity are achieved. The light emission from the needle tip is also measured in Ar/CF4 (95/5) gas mixture. The result shows a promising application for imaging.</description><identifier>ISSN: 1674-1137</identifier><identifier>EISSN: 0254-3052</identifier><identifier>DOI: 10.1088/1674-1137/36/10/012</identifier><language>eng</language><subject>Arrays ; Detectors ; Gain ; Gas detectors ; Leaks ; Microstructure ; Needles ; Waveforms ; 图案 ; 微细 ; 微观结构 ; 气体检测仪 ; 气体检测器 ; 泄漏 ; 结构性能 ; 阵列探测器</subject><ispartof>Chinese physics C, 2012-10, Vol.36 (10), p.985-990</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c308t-b596f01df198cd257cd55f45d9cde354c4c896a82dd479d0d533bd929964c09b3</citedby><cites>FETCH-LOGICAL-c308t-b596f01df198cd257cd55f45d9cde354c4c896a82dd479d0d533bd929964c09b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/92043A/92043A.jpg</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids></links><search><creatorcontrib>章爱武 谢宇广 俞伯祥 安正华 王志刚 蔡啸 孙希磊 石峰 方建 薛镇 吕绮雯 孙丽君 葛永帅 刘颖彪 刘宏邦 郑阳恒 谢一冈 胡涛 周莉 吕军光</creatorcontrib><title>Performance study of a micro-pattern gas detector: leak microstructure</title><title>Chinese physics C</title><addtitle>Chinese Physica C</addtitle><description>A micro-pattern gas detector named leak microstructure (LM) has been studied. A new chemical electrolytic technique is introduced to make perfect shaped LM needles with very sharp tips, and this method may be developed to make LM array detectors in batches. The experimental results are presented for both a single needle LM detector and a small LM array detector. The gas gain is up to 105 by calculation from the waveform. Good gain stability and uniformity are achieved. The light emission from the needle tip is also measured in Ar/CF4 (95/5) gas mixture. The result shows a promising application for imaging.</description><subject>Arrays</subject><subject>Detectors</subject><subject>Gain</subject><subject>Gas detectors</subject><subject>Leaks</subject><subject>Microstructure</subject><subject>Needles</subject><subject>Waveforms</subject><subject>图案</subject><subject>微细</subject><subject>微观结构</subject><subject>气体检测仪</subject><subject>气体检测器</subject><subject>泄漏</subject><subject>结构性能</subject><subject>阵列探测器</subject><issn>1674-1137</issn><issn>0254-3052</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNo9kEtOwzAURS0EEqWwAiZmxiTEjj-xh6gCilQJBjC2XH9KIIlb2xmwFdbCntgCiVp19KSnc67euwBcY3SHkRAl5jUtMCZ1SXiJUYlwdQJmqGK0IIhVp2B2JM7BRUqfCHE6ijOwfHXRh9jp3jiY8mC_YfBQw64xMRRbnbOLPdzoBK3LzuQQ_35_YOv01x5JOQ4mD9FdgjOv2-SuDnMO3h8f3hbLYvXy9Ly4XxWGIJGLNZPcI2w9lsLYitXGMuYps9JYRxg11AjJtaispbW0yDJC1lZWUnJqkFyTObjd525j2A0uZdU1ybi21b0LQ1KYElmL8VM6omSPTnem6LzaxqbT8VthpKbe1NSKmlpRhE_LsbfRujlYH6Hf7Jp-c9TGaCwYYuQfoV5tCQ</recordid><startdate>20121001</startdate><enddate>20121001</enddate><creator>章爱武 谢宇广 俞伯祥 安正华 王志刚 蔡啸 孙希磊 石峰 方建 薛镇 吕绮雯 孙丽君 葛永帅 刘颖彪 刘宏邦 郑阳恒 谢一冈 胡涛 周莉 吕军光</creator><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>~WA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20121001</creationdate><title>Performance study of a micro-pattern gas detector: leak microstructure</title><author>章爱武 谢宇广 俞伯祥 安正华 王志刚 蔡啸 孙希磊 石峰 方建 薛镇 吕绮雯 孙丽君 葛永帅 刘颖彪 刘宏邦 郑阳恒 谢一冈 胡涛 周莉 吕军光</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c308t-b596f01df198cd257cd55f45d9cde354c4c896a82dd479d0d533bd929964c09b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Arrays</topic><topic>Detectors</topic><topic>Gain</topic><topic>Gas detectors</topic><topic>Leaks</topic><topic>Microstructure</topic><topic>Needles</topic><topic>Waveforms</topic><topic>图案</topic><topic>微细</topic><topic>微观结构</topic><topic>气体检测仪</topic><topic>气体检测器</topic><topic>泄漏</topic><topic>结构性能</topic><topic>阵列探测器</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>章爱武 谢宇广 俞伯祥 安正华 王志刚 蔡啸 孙希磊 石峰 方建 薛镇 吕绮雯 孙丽君 葛永帅 刘颖彪 刘宏邦 郑阳恒 谢一冈 胡涛 周莉 吕军光</creatorcontrib><collection>中文科技期刊数据库</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库- 镜像站点</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Chinese physics C</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>章爱武 谢宇广 俞伯祥 安正华 王志刚 蔡啸 孙希磊 石峰 方建 薛镇 吕绮雯 孙丽君 葛永帅 刘颖彪 刘宏邦 郑阳恒 谢一冈 胡涛 周莉 吕军光</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Performance study of a micro-pattern gas detector: leak microstructure</atitle><jtitle>Chinese physics C</jtitle><addtitle>Chinese Physica C</addtitle><date>2012-10-01</date><risdate>2012</risdate><volume>36</volume><issue>10</issue><spage>985</spage><epage>990</epage><pages>985-990</pages><issn>1674-1137</issn><eissn>0254-3052</eissn><abstract>A micro-pattern gas detector named leak microstructure (LM) has been studied. A new chemical electrolytic technique is introduced to make perfect shaped LM needles with very sharp tips, and this method may be developed to make LM array detectors in batches. The experimental results are presented for both a single needle LM detector and a small LM array detector. The gas gain is up to 105 by calculation from the waveform. Good gain stability and uniformity are achieved. The light emission from the needle tip is also measured in Ar/CF4 (95/5) gas mixture. The result shows a promising application for imaging.</abstract><doi>10.1088/1674-1137/36/10/012</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1674-1137 |
ispartof | Chinese physics C, 2012-10, Vol.36 (10), p.985-990 |
issn | 1674-1137 0254-3052 |
language | eng |
recordid | cdi_proquest_miscellaneous_1439781134 |
source | IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link; Alma/SFX Local Collection |
subjects | Arrays Detectors Gain Gas detectors Leaks Microstructure Needles Waveforms 图案 微细 微观结构 气体检测仪 气体检测器 泄漏 结构性能 阵列探测器 |
title | Performance study of a micro-pattern gas detector: leak microstructure |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T06%3A27%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Performance%20study%20of%20a%20micro-pattern%20gas%20detector%EF%BC%9A%20leak%20microstructure&rft.jtitle=Chinese%20physics%20C&rft.au=%E7%AB%A0%E7%88%B1%E6%AD%A6%20%E8%B0%A2%E5%AE%87%E5%B9%BF%20%E4%BF%9E%E4%BC%AF%E7%A5%A5%20%E5%AE%89%E6%AD%A3%E5%8D%8E%20%E7%8E%8B%E5%BF%97%E5%88%9A%20%E8%94%A1%E5%95%B8%20%E5%AD%99%E5%B8%8C%E7%A3%8A%20%E7%9F%B3%E5%B3%B0%20%E6%96%B9%E5%BB%BA%20%E8%96%9B%E9%95%87%20%E5%90%95%E7%BB%AE%E9%9B%AF%20%E5%AD%99%E4%B8%BD%E5%90%9B%20%E8%91%9B%E6%B0%B8%E5%B8%85%20%E5%88%98%E9%A2%96%E5%BD%AA%20%E5%88%98%E5%AE%8F%E9%82%A6%20%E9%83%91%E9%98%B3%E6%81%92%20%E8%B0%A2%E4%B8%80%E5%86%88%20%E8%83%A1%E6%B6%9B%20%E5%91%A8%E8%8E%89%20%E5%90%95%E5%86%9B%E5%85%89&rft.date=2012-10-01&rft.volume=36&rft.issue=10&rft.spage=985&rft.epage=990&rft.pages=985-990&rft.issn=1674-1137&rft.eissn=0254-3052&rft_id=info:doi/10.1088/1674-1137/36/10/012&rft_dat=%3Cproquest_cross%3E1439781134%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1439781134&rft_id=info:pmid/&rft_cqvip_id=43918505&rfr_iscdi=true |