Coronary artery stents: influence of adaptive statistical iterative reconstruction on image quality using 64-HDCT

The assessment of coronary stents with present-generation 64-detector row computed tomography (HDCT) scanners is limited by image noise and blooming artefacts. We evaluated the performance of adaptive statistical iterative reconstruction (ASIR) for noise reduction in coronary stent imaging with HDCT...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European heart journal cardiovascular imaging 2013-10, Vol.14 (10), p.969-977
Hauptverfasser: Gebhard, Cathérine, Fiechter, Michael, Fuchs, Tobias A, Stehli, Julia, Müller, Ennio, Stähli, Barbara E, Gebhard, Caroline E, Ghadri, Jelena R, Klaeser, Bernd, Gaemperli, Oliver, Kaufmann, Philipp A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 977
container_issue 10
container_start_page 969
container_title European heart journal cardiovascular imaging
container_volume 14
creator Gebhard, Cathérine
Fiechter, Michael
Fuchs, Tobias A
Stehli, Julia
Müller, Ennio
Stähli, Barbara E
Gebhard, Caroline E
Ghadri, Jelena R
Klaeser, Bernd
Gaemperli, Oliver
Kaufmann, Philipp A
description The assessment of coronary stents with present-generation 64-detector row computed tomography (HDCT) scanners is limited by image noise and blooming artefacts. We evaluated the performance of adaptive statistical iterative reconstruction (ASIR) for noise reduction in coronary stent imaging with HDCT. In 50 stents of 28 patients (mean age 64 ± 10 years) undergoing coronary CT angiography (CCTA) on an HDCT scanner the mean in-stent luminal diameter, stent length, image quality, in-stent contrast attenuation, and image noise were assessed. Studies were reconstructed using filtered back projection (FBP) and ASIR-FBP composites. ASIR resulted in reduced image noise vs. FBP (P < 0.0001). Two readers graded the CCTA stent image quality on a 4-point Likert scale and determined the proportion of interpretable stent segments. The best image quality for all clinical images was obtained with 40 and 60% ASIR with significantly larger luminal area visualization compared with FBP (+42.1 ± 5.4% with 100% ASIR vs. FBP alone; P < 0.0001) while the stent length was decreased (-4.7 ± 0.9%,
doi_str_mv 10.1093/ehjci/jet013
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1436564500</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1436564500</sourcerecordid><originalsourceid>FETCH-LOGICAL-c395t-41f11db33ec96d8fcb717dd9b501351f704f21cc38f67bf02f8c5183bd7602853</originalsourceid><addsrcrecordid>eNo9kMtLAzEQxoMottTePEuOHlyb5z68yfqoUPBSz0s2m9SUbdImWaH_vbGtHQZmmPnxwfcBcIvRI0YVnanvtTSztYoI0wswJogVGWGYXJ53xEZgGsIapeIsZwRfgxGhjJQ5R2Owq513Vvg9FD6qNEJUNoYnaKzuB2Wlgk5D0YltND8qfUU0IRopemgSLw5Xr6SzIfpBRuMsTG02YqXgbhC9iXs4BGNXMGfZ_KVe3oArLfqgpqc5AV9vr8t6ni0-3z_q50UmacVjxrDGuGspVbLKu1LLtsBF11UtT1Y51gVimmApaanzotWI6FJyXNK2K3JESk4n4P6ou_VuN6gQm40JUvW9sMoNocGM5jxnHKGEPhxR6V0IXulm65MDv28wav5ybg45N8ecE353Uh7ajerO8H-q9BepG3uZ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1436564500</pqid></control><display><type>article</type><title>Coronary artery stents: influence of adaptive statistical iterative reconstruction on image quality using 64-HDCT</title><source>MEDLINE</source><source>Oxford University Press Journals All Titles (1996-Current)</source><source>Alma/SFX Local Collection</source><creator>Gebhard, Cathérine ; Fiechter, Michael ; Fuchs, Tobias A ; Stehli, Julia ; Müller, Ennio ; Stähli, Barbara E ; Gebhard, Caroline E ; Ghadri, Jelena R ; Klaeser, Bernd ; Gaemperli, Oliver ; Kaufmann, Philipp A</creator><creatorcontrib>Gebhard, Cathérine ; Fiechter, Michael ; Fuchs, Tobias A ; Stehli, Julia ; Müller, Ennio ; Stähli, Barbara E ; Gebhard, Caroline E ; Ghadri, Jelena R ; Klaeser, Bernd ; Gaemperli, Oliver ; Kaufmann, Philipp A</creatorcontrib><description>The assessment of coronary stents with present-generation 64-detector row computed tomography (HDCT) scanners is limited by image noise and blooming artefacts. We evaluated the performance of adaptive statistical iterative reconstruction (ASIR) for noise reduction in coronary stent imaging with HDCT. In 50 stents of 28 patients (mean age 64 ± 10 years) undergoing coronary CT angiography (CCTA) on an HDCT scanner the mean in-stent luminal diameter, stent length, image quality, in-stent contrast attenuation, and image noise were assessed. Studies were reconstructed using filtered back projection (FBP) and ASIR-FBP composites. ASIR resulted in reduced image noise vs. FBP (P &lt; 0.0001). Two readers graded the CCTA stent image quality on a 4-point Likert scale and determined the proportion of interpretable stent segments. The best image quality for all clinical images was obtained with 40 and 60% ASIR with significantly larger luminal area visualization compared with FBP (+42.1 ± 5.4% with 100% ASIR vs. FBP alone; P &lt; 0.0001) while the stent length was decreased (-4.7 ± 0.9%, &lt;P = 0.002) and volume measurements were unaffected. Reconstruction of CCTA from HDCT using 40 and 60% ASIR incrementally improves intra-stent luminal area, diameter visualization, and image quality compared with FBP reconstruction.</description><identifier>ISSN: 2047-2404</identifier><identifier>EISSN: 2047-2412</identifier><identifier>DOI: 10.1093/ehjci/jet013</identifier><identifier>PMID: 23428650</identifier><language>eng</language><publisher>England</publisher><subject>Aged ; Angioplasty, Balloon, Coronary - instrumentation ; Angioplasty, Balloon, Coronary - methods ; Cohort Studies ; Coronary Angiography - methods ; Coronary Stenosis - diagnostic imaging ; Coronary Stenosis - therapy ; Female ; Humans ; Image Processing, Computer-Assisted ; Male ; Middle Aged ; Multidetector Computed Tomography - methods ; Observer Variation ; Quality Control ; Radiation Dosage ; Radiographic Image Interpretation, Computer-Assisted ; Reproducibility of Results ; Risk Assessment ; Sensitivity and Specificity ; Stents</subject><ispartof>European heart journal cardiovascular imaging, 2013-10, Vol.14 (10), p.969-977</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c395t-41f11db33ec96d8fcb717dd9b501351f704f21cc38f67bf02f8c5183bd7602853</citedby><cites>FETCH-LOGICAL-c395t-41f11db33ec96d8fcb717dd9b501351f704f21cc38f67bf02f8c5183bd7602853</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,27929,27930</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23428650$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gebhard, Cathérine</creatorcontrib><creatorcontrib>Fiechter, Michael</creatorcontrib><creatorcontrib>Fuchs, Tobias A</creatorcontrib><creatorcontrib>Stehli, Julia</creatorcontrib><creatorcontrib>Müller, Ennio</creatorcontrib><creatorcontrib>Stähli, Barbara E</creatorcontrib><creatorcontrib>Gebhard, Caroline E</creatorcontrib><creatorcontrib>Ghadri, Jelena R</creatorcontrib><creatorcontrib>Klaeser, Bernd</creatorcontrib><creatorcontrib>Gaemperli, Oliver</creatorcontrib><creatorcontrib>Kaufmann, Philipp A</creatorcontrib><title>Coronary artery stents: influence of adaptive statistical iterative reconstruction on image quality using 64-HDCT</title><title>European heart journal cardiovascular imaging</title><addtitle>Eur Heart J Cardiovasc Imaging</addtitle><description>The assessment of coronary stents with present-generation 64-detector row computed tomography (HDCT) scanners is limited by image noise and blooming artefacts. We evaluated the performance of adaptive statistical iterative reconstruction (ASIR) for noise reduction in coronary stent imaging with HDCT. In 50 stents of 28 patients (mean age 64 ± 10 years) undergoing coronary CT angiography (CCTA) on an HDCT scanner the mean in-stent luminal diameter, stent length, image quality, in-stent contrast attenuation, and image noise were assessed. Studies were reconstructed using filtered back projection (FBP) and ASIR-FBP composites. ASIR resulted in reduced image noise vs. FBP (P &lt; 0.0001). Two readers graded the CCTA stent image quality on a 4-point Likert scale and determined the proportion of interpretable stent segments. The best image quality for all clinical images was obtained with 40 and 60% ASIR with significantly larger luminal area visualization compared with FBP (+42.1 ± 5.4% with 100% ASIR vs. FBP alone; P &lt; 0.0001) while the stent length was decreased (-4.7 ± 0.9%, &lt;P = 0.002) and volume measurements were unaffected. Reconstruction of CCTA from HDCT using 40 and 60% ASIR incrementally improves intra-stent luminal area, diameter visualization, and image quality compared with FBP reconstruction.</description><subject>Aged</subject><subject>Angioplasty, Balloon, Coronary - instrumentation</subject><subject>Angioplasty, Balloon, Coronary - methods</subject><subject>Cohort Studies</subject><subject>Coronary Angiography - methods</subject><subject>Coronary Stenosis - diagnostic imaging</subject><subject>Coronary Stenosis - therapy</subject><subject>Female</subject><subject>Humans</subject><subject>Image Processing, Computer-Assisted</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Multidetector Computed Tomography - methods</subject><subject>Observer Variation</subject><subject>Quality Control</subject><subject>Radiation Dosage</subject><subject>Radiographic Image Interpretation, Computer-Assisted</subject><subject>Reproducibility of Results</subject><subject>Risk Assessment</subject><subject>Sensitivity and Specificity</subject><subject>Stents</subject><issn>2047-2404</issn><issn>2047-2412</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kMtLAzEQxoMottTePEuOHlyb5z68yfqoUPBSz0s2m9SUbdImWaH_vbGtHQZmmPnxwfcBcIvRI0YVnanvtTSztYoI0wswJogVGWGYXJ53xEZgGsIapeIsZwRfgxGhjJQ5R2Owq513Vvg9FD6qNEJUNoYnaKzuB2Wlgk5D0YltND8qfUU0IRopemgSLw5Xr6SzIfpBRuMsTG02YqXgbhC9iXs4BGNXMGfZ_KVe3oArLfqgpqc5AV9vr8t6ni0-3z_q50UmacVjxrDGuGspVbLKu1LLtsBF11UtT1Y51gVimmApaanzotWI6FJyXNK2K3JESk4n4P6ou_VuN6gQm40JUvW9sMoNocGM5jxnHKGEPhxR6V0IXulm65MDv28wav5ybg45N8ecE353Uh7ajerO8H-q9BepG3uZ</recordid><startdate>20131001</startdate><enddate>20131001</enddate><creator>Gebhard, Cathérine</creator><creator>Fiechter, Michael</creator><creator>Fuchs, Tobias A</creator><creator>Stehli, Julia</creator><creator>Müller, Ennio</creator><creator>Stähli, Barbara E</creator><creator>Gebhard, Caroline E</creator><creator>Ghadri, Jelena R</creator><creator>Klaeser, Bernd</creator><creator>Gaemperli, Oliver</creator><creator>Kaufmann, Philipp A</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20131001</creationdate><title>Coronary artery stents: influence of adaptive statistical iterative reconstruction on image quality using 64-HDCT</title><author>Gebhard, Cathérine ; Fiechter, Michael ; Fuchs, Tobias A ; Stehli, Julia ; Müller, Ennio ; Stähli, Barbara E ; Gebhard, Caroline E ; Ghadri, Jelena R ; Klaeser, Bernd ; Gaemperli, Oliver ; Kaufmann, Philipp A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c395t-41f11db33ec96d8fcb717dd9b501351f704f21cc38f67bf02f8c5183bd7602853</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Aged</topic><topic>Angioplasty, Balloon, Coronary - instrumentation</topic><topic>Angioplasty, Balloon, Coronary - methods</topic><topic>Cohort Studies</topic><topic>Coronary Angiography - methods</topic><topic>Coronary Stenosis - diagnostic imaging</topic><topic>Coronary Stenosis - therapy</topic><topic>Female</topic><topic>Humans</topic><topic>Image Processing, Computer-Assisted</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Multidetector Computed Tomography - methods</topic><topic>Observer Variation</topic><topic>Quality Control</topic><topic>Radiation Dosage</topic><topic>Radiographic Image Interpretation, Computer-Assisted</topic><topic>Reproducibility of Results</topic><topic>Risk Assessment</topic><topic>Sensitivity and Specificity</topic><topic>Stents</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gebhard, Cathérine</creatorcontrib><creatorcontrib>Fiechter, Michael</creatorcontrib><creatorcontrib>Fuchs, Tobias A</creatorcontrib><creatorcontrib>Stehli, Julia</creatorcontrib><creatorcontrib>Müller, Ennio</creatorcontrib><creatorcontrib>Stähli, Barbara E</creatorcontrib><creatorcontrib>Gebhard, Caroline E</creatorcontrib><creatorcontrib>Ghadri, Jelena R</creatorcontrib><creatorcontrib>Klaeser, Bernd</creatorcontrib><creatorcontrib>Gaemperli, Oliver</creatorcontrib><creatorcontrib>Kaufmann, Philipp A</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European heart journal cardiovascular imaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gebhard, Cathérine</au><au>Fiechter, Michael</au><au>Fuchs, Tobias A</au><au>Stehli, Julia</au><au>Müller, Ennio</au><au>Stähli, Barbara E</au><au>Gebhard, Caroline E</au><au>Ghadri, Jelena R</au><au>Klaeser, Bernd</au><au>Gaemperli, Oliver</au><au>Kaufmann, Philipp A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Coronary artery stents: influence of adaptive statistical iterative reconstruction on image quality using 64-HDCT</atitle><jtitle>European heart journal cardiovascular imaging</jtitle><addtitle>Eur Heart J Cardiovasc Imaging</addtitle><date>2013-10-01</date><risdate>2013</risdate><volume>14</volume><issue>10</issue><spage>969</spage><epage>977</epage><pages>969-977</pages><issn>2047-2404</issn><eissn>2047-2412</eissn><abstract>The assessment of coronary stents with present-generation 64-detector row computed tomography (HDCT) scanners is limited by image noise and blooming artefacts. We evaluated the performance of adaptive statistical iterative reconstruction (ASIR) for noise reduction in coronary stent imaging with HDCT. In 50 stents of 28 patients (mean age 64 ± 10 years) undergoing coronary CT angiography (CCTA) on an HDCT scanner the mean in-stent luminal diameter, stent length, image quality, in-stent contrast attenuation, and image noise were assessed. Studies were reconstructed using filtered back projection (FBP) and ASIR-FBP composites. ASIR resulted in reduced image noise vs. FBP (P &lt; 0.0001). Two readers graded the CCTA stent image quality on a 4-point Likert scale and determined the proportion of interpretable stent segments. The best image quality for all clinical images was obtained with 40 and 60% ASIR with significantly larger luminal area visualization compared with FBP (+42.1 ± 5.4% with 100% ASIR vs. FBP alone; P &lt; 0.0001) while the stent length was decreased (-4.7 ± 0.9%, &lt;P = 0.002) and volume measurements were unaffected. Reconstruction of CCTA from HDCT using 40 and 60% ASIR incrementally improves intra-stent luminal area, diameter visualization, and image quality compared with FBP reconstruction.</abstract><cop>England</cop><pmid>23428650</pmid><doi>10.1093/ehjci/jet013</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2047-2404
ispartof European heart journal cardiovascular imaging, 2013-10, Vol.14 (10), p.969-977
issn 2047-2404
2047-2412
language eng
recordid cdi_proquest_miscellaneous_1436564500
source MEDLINE; Oxford University Press Journals All Titles (1996-Current); Alma/SFX Local Collection
subjects Aged
Angioplasty, Balloon, Coronary - instrumentation
Angioplasty, Balloon, Coronary - methods
Cohort Studies
Coronary Angiography - methods
Coronary Stenosis - diagnostic imaging
Coronary Stenosis - therapy
Female
Humans
Image Processing, Computer-Assisted
Male
Middle Aged
Multidetector Computed Tomography - methods
Observer Variation
Quality Control
Radiation Dosage
Radiographic Image Interpretation, Computer-Assisted
Reproducibility of Results
Risk Assessment
Sensitivity and Specificity
Stents
title Coronary artery stents: influence of adaptive statistical iterative reconstruction on image quality using 64-HDCT
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-15T12%3A13%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Coronary%20artery%20stents:%20influence%20of%20adaptive%20statistical%20iterative%20reconstruction%20on%20image%20quality%20using%2064-HDCT&rft.jtitle=European%20heart%20journal%20cardiovascular%20imaging&rft.au=Gebhard,%20Cath%C3%A9rine&rft.date=2013-10-01&rft.volume=14&rft.issue=10&rft.spage=969&rft.epage=977&rft.pages=969-977&rft.issn=2047-2404&rft.eissn=2047-2412&rft_id=info:doi/10.1093/ehjci/jet013&rft_dat=%3Cproquest_cross%3E1436564500%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1436564500&rft_id=info:pmid/23428650&rfr_iscdi=true