Determination of complexing capacities of ligands in natural waters and conditional stability constants of the copper complexes by means of manganese dioxide

A dispersion of manganese dioxide is used as a weak ion exchanger in the determination of the complexing capacities of natural waters for copper and in the estimation of the stability constants of the complexes formed, at the concentration and pH at which the ligands occur in natural waters. Experim...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytica chimica acta 1979-04, Vol.106 (1), p.113-120
Hauptverfasser: van den Berg, C.M.G., Kramer, J.R.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 120
container_issue 1
container_start_page 113
container_title Analytica chimica acta
container_volume 106
creator van den Berg, C.M.G.
Kramer, J.R.
description A dispersion of manganese dioxide is used as a weak ion exchanger in the determination of the complexing capacities of natural waters for copper and in the estimation of the stability constants of the complexes formed, at the concentration and pH at which the ligands occur in natural waters. Experiments were done at 25°C and 0.01 M ionic strength. Stability constants varied from 10 7.8 to 10 8.8 at pH 7.6 for ligands in lakes and rivers. The constant for the copper—fulvic acid complex was estimated as 10 7.8 at pH 7.6. Only one complexing site of major importance for natural water environments was observed.
doi_str_mv 10.1016/S0003-2670(01)83711-9
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_13920731</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003267001837119</els_id><sourcerecordid>13920731</sourcerecordid><originalsourceid>FETCH-LOGICAL-a427t-586e1c9ecb1156c0709d17f06a9c3a59a7858574cfd95277eec686c5cf47b8c93</originalsourceid><addsrcrecordid>eNqFUctO3DAUtaoidTr0Eyp5hWARauflZFWhgZZKI7GAri3n5mZ6UeKktgdmPqb_WmcG2LKy7vF5XPsw9lWKSylk-e1eCJElaanEuZAXVaakTOoPbCErlSV5luYf2eKN8ol99v4xjqkU-YL9u8aAbiBrAo2Wjx2HcZh63JHdcDCTAQqEfr7oaWNs6zlZHtlbZ3r-bKLY8whHmW1p9oiwD6ahnsJ-RuNgw8Eg_MEITBO615Bo3Oz5gMYeCIOxMQI98pbGHbV4yk4603v88nIu2e8fNw-r22R99_PX6mqdmDxVISmqEiXUCI2URQlCibqVqhOlqSEzRW1UVVSFyqFr6yJVChHKqoQCulw1FdTZkp0dfSc3_t2iD3ogD9j3cZtx67XM6lSoTEZicSSCG7132OnJ0WDcXkuh5zL0oQw9_7QWUh_K0HPA96MO4yueCJ32QGgBW3IIQbcjvePwH9ITlVo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>13920731</pqid></control><display><type>article</type><title>Determination of complexing capacities of ligands in natural waters and conditional stability constants of the copper complexes by means of manganese dioxide</title><source>Access via ScienceDirect (Elsevier)</source><creator>van den Berg, C.M.G. ; Kramer, J.R.</creator><creatorcontrib>van den Berg, C.M.G. ; Kramer, J.R.</creatorcontrib><description>A dispersion of manganese dioxide is used as a weak ion exchanger in the determination of the complexing capacities of natural waters for copper and in the estimation of the stability constants of the complexes formed, at the concentration and pH at which the ligands occur in natural waters. Experiments were done at 25°C and 0.01 M ionic strength. Stability constants varied from 10 7.8 to 10 8.8 at pH 7.6 for ligands in lakes and rivers. The constant for the copper—fulvic acid complex was estimated as 10 7.8 at pH 7.6. Only one complexing site of major importance for natural water environments was observed.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/S0003-2670(01)83711-9</identifier><language>eng</language><publisher>Elsevier B.V</publisher><ispartof>Analytica chimica acta, 1979-04, Vol.106 (1), p.113-120</ispartof><rights>1979</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a427t-586e1c9ecb1156c0709d17f06a9c3a59a7858574cfd95277eec686c5cf47b8c93</citedby><cites>FETCH-LOGICAL-a427t-586e1c9ecb1156c0709d17f06a9c3a59a7858574cfd95277eec686c5cf47b8c93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0003-2670(01)83711-9$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>315,782,786,3552,27931,27932,46002</link.rule.ids></links><search><creatorcontrib>van den Berg, C.M.G.</creatorcontrib><creatorcontrib>Kramer, J.R.</creatorcontrib><title>Determination of complexing capacities of ligands in natural waters and conditional stability constants of the copper complexes by means of manganese dioxide</title><title>Analytica chimica acta</title><description>A dispersion of manganese dioxide is used as a weak ion exchanger in the determination of the complexing capacities of natural waters for copper and in the estimation of the stability constants of the complexes formed, at the concentration and pH at which the ligands occur in natural waters. Experiments were done at 25°C and 0.01 M ionic strength. Stability constants varied from 10 7.8 to 10 8.8 at pH 7.6 for ligands in lakes and rivers. The constant for the copper—fulvic acid complex was estimated as 10 7.8 at pH 7.6. Only one complexing site of major importance for natural water environments was observed.</description><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1979</creationdate><recordtype>article</recordtype><recordid>eNqFUctO3DAUtaoidTr0Eyp5hWARauflZFWhgZZKI7GAri3n5mZ6UeKktgdmPqb_WmcG2LKy7vF5XPsw9lWKSylk-e1eCJElaanEuZAXVaakTOoPbCErlSV5luYf2eKN8ol99v4xjqkU-YL9u8aAbiBrAo2Wjx2HcZh63JHdcDCTAQqEfr7oaWNs6zlZHtlbZ3r-bKLY8whHmW1p9oiwD6ahnsJ-RuNgw8Eg_MEITBO615Bo3Oz5gMYeCIOxMQI98pbGHbV4yk4603v88nIu2e8fNw-r22R99_PX6mqdmDxVISmqEiXUCI2URQlCibqVqhOlqSEzRW1UVVSFyqFr6yJVChHKqoQCulw1FdTZkp0dfSc3_t2iD3ogD9j3cZtx67XM6lSoTEZicSSCG7132OnJ0WDcXkuh5zL0oQw9_7QWUh_K0HPA96MO4yueCJ32QGgBW3IIQbcjvePwH9ITlVo</recordid><startdate>19790401</startdate><enddate>19790401</enddate><creator>van den Berg, C.M.G.</creator><creator>Kramer, J.R.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QH</scope></search><sort><creationdate>19790401</creationdate><title>Determination of complexing capacities of ligands in natural waters and conditional stability constants of the copper complexes by means of manganese dioxide</title><author>van den Berg, C.M.G. ; Kramer, J.R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a427t-586e1c9ecb1156c0709d17f06a9c3a59a7858574cfd95277eec686c5cf47b8c93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1979</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>van den Berg, C.M.G.</creatorcontrib><creatorcontrib>Kramer, J.R.</creatorcontrib><collection>CrossRef</collection><collection>Aqualine</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>van den Berg, C.M.G.</au><au>Kramer, J.R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of complexing capacities of ligands in natural waters and conditional stability constants of the copper complexes by means of manganese dioxide</atitle><jtitle>Analytica chimica acta</jtitle><date>1979-04-01</date><risdate>1979</risdate><volume>106</volume><issue>1</issue><spage>113</spage><epage>120</epage><pages>113-120</pages><issn>0003-2670</issn><eissn>1873-4324</eissn><abstract>A dispersion of manganese dioxide is used as a weak ion exchanger in the determination of the complexing capacities of natural waters for copper and in the estimation of the stability constants of the complexes formed, at the concentration and pH at which the ligands occur in natural waters. Experiments were done at 25°C and 0.01 M ionic strength. Stability constants varied from 10 7.8 to 10 8.8 at pH 7.6 for ligands in lakes and rivers. The constant for the copper—fulvic acid complex was estimated as 10 7.8 at pH 7.6. Only one complexing site of major importance for natural water environments was observed.</abstract><pub>Elsevier B.V</pub><doi>10.1016/S0003-2670(01)83711-9</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2670
ispartof Analytica chimica acta, 1979-04, Vol.106 (1), p.113-120
issn 0003-2670
1873-4324
language eng
recordid cdi_proquest_miscellaneous_13920731
source Access via ScienceDirect (Elsevier)
title Determination of complexing capacities of ligands in natural waters and conditional stability constants of the copper complexes by means of manganese dioxide
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-04T02%3A17%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20complexing%20capacities%20of%20ligands%20in%20natural%20waters%20and%20conditional%20stability%20constants%20of%20the%20copper%20complexes%20by%20means%20of%20manganese%20dioxide&rft.jtitle=Analytica%20chimica%20acta&rft.au=van%20den%20Berg,%20C.M.G.&rft.date=1979-04-01&rft.volume=106&rft.issue=1&rft.spage=113&rft.epage=120&rft.pages=113-120&rft.issn=0003-2670&rft.eissn=1873-4324&rft_id=info:doi/10.1016/S0003-2670(01)83711-9&rft_dat=%3Cproquest_cross%3E13920731%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=13920731&rft_id=info:pmid/&rft_els_id=S0003267001837119&rfr_iscdi=true