Determination of mercury traces by differential-pulse stripping voltammetry after sorption of mercury vapour on a gold-plated electrode
Trace mercury is reduced with tin(II) to mercury metal, which is volatilised by bubbling air through the solution. A certain fraction of this mercury is sorbed on a rotating gold disk electrode and stripped in a thiocyanate solution. The detection limit is about 30 ng Hg(II) in solution; the relativ...
Gespeichert in:
Veröffentlicht in: | Analytica chimica acta 1987, Vol.199, p.167-171 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 171 |
---|---|
container_issue | |
container_start_page | 167 |
container_title | Analytica chimica acta |
container_volume | 199 |
creator | Scholz, Fritz Nitschke, Lutz Henrion, Günter |
description | Trace mercury is reduced with tin(II) to mercury metal, which is volatilised by bubbling air through the solution. A certain fraction of this mercury is sorbed on a rotating gold disk electrode and stripped in a thiocyanate solution. The detection limit is about 30 ng Hg(II) in solution; the relative standard deviation is 6% for 100 ng Hg(II) (
n = 7). The detection limit for mercury in air is 1.7 ng l
−1 with a preconcentration time of 10 min. |
doi_str_mv | 10.1016/S0003-2670(00)82809-3 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_13777990</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003267000828093</els_id><sourcerecordid>13777990</sourcerecordid><originalsourceid>FETCH-LOGICAL-c284t-d9053599e8db51ef9a1fc7d78500e7c4e81fe32bc79dac3ec43d1568876224e13</originalsourceid><addsrcrecordid>eNqFkMGKFDEQhhtRcFx9BCEHET20VpLuTnISWXVXWPCgnkMmqSyRdKdN0gPzBL62mZ1lD148FSm-_y_ydd1LCu8o0On9dwDgPZsEvAF4K5kE1fNH3Y5KwfuBs-Fxt3tAnnbPSvnVnozCsOv-fMKKeQ6LqSEtJHkyY7ZbPpKajcVC9kfigveYcanBxH7dYkFSag7rGpZbckixmnnG2iLGty5SUl7_LTuYNW2ZtKUhtym6fo2moiMY0dacHD7vnnjTml_cz4vu55fPPy6v-5tvV18vP970lsmh9k7ByEelULr9SNErQ70VTsgRAIUdUFKPnO2tUM5Yjnbgjo6TlGJibEDKL7rX5941p98blqrnUCzGaBZMW9GUCyGUggaOZ9DmVEpGr9ccZpOPmoI-add32vXJqQbQd9o1b7lX9wdMsSb6bBYbykNYjAomdsI-nDFsnz0EzLrYgItFF3JTol0K_zn0F-fEmkg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>13777990</pqid></control><display><type>article</type><title>Determination of mercury traces by differential-pulse stripping voltammetry after sorption of mercury vapour on a gold-plated electrode</title><source>ScienceDirect Freedom Collection (Elsevier)</source><creator>Scholz, Fritz ; Nitschke, Lutz ; Henrion, Günter</creator><creatorcontrib>Scholz, Fritz ; Nitschke, Lutz ; Henrion, Günter</creatorcontrib><description>Trace mercury is reduced with tin(II) to mercury metal, which is volatilised by bubbling air through the solution. A certain fraction of this mercury is sorbed on a rotating gold disk electrode and stripped in a thiocyanate solution. The detection limit is about 30 ng Hg(II) in solution; the relative standard deviation is 6% for 100 ng Hg(II) (
n = 7). The detection limit for mercury in air is 1.7 ng l
−1 with a preconcentration time of 10 min.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/S0003-2670(00)82809-3</identifier><identifier>CODEN: ACACAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Chemistry ; Electrochemical methods ; Exact sciences and technology</subject><ispartof>Analytica chimica acta, 1987, Vol.199, p.167-171</ispartof><rights>1987</rights><rights>1988 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c284t-d9053599e8db51ef9a1fc7d78500e7c4e81fe32bc79dac3ec43d1568876224e13</citedby><cites>FETCH-LOGICAL-c284t-d9053599e8db51ef9a1fc7d78500e7c4e81fe32bc79dac3ec43d1568876224e13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0003-2670(00)82809-3$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,4024,27923,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=7590623$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Scholz, Fritz</creatorcontrib><creatorcontrib>Nitschke, Lutz</creatorcontrib><creatorcontrib>Henrion, Günter</creatorcontrib><title>Determination of mercury traces by differential-pulse stripping voltammetry after sorption of mercury vapour on a gold-plated electrode</title><title>Analytica chimica acta</title><description>Trace mercury is reduced with tin(II) to mercury metal, which is volatilised by bubbling air through the solution. A certain fraction of this mercury is sorbed on a rotating gold disk electrode and stripped in a thiocyanate solution. The detection limit is about 30 ng Hg(II) in solution; the relative standard deviation is 6% for 100 ng Hg(II) (
n = 7). The detection limit for mercury in air is 1.7 ng l
−1 with a preconcentration time of 10 min.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Electrochemical methods</subject><subject>Exact sciences and technology</subject><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1987</creationdate><recordtype>article</recordtype><recordid>eNqFkMGKFDEQhhtRcFx9BCEHET20VpLuTnISWXVXWPCgnkMmqSyRdKdN0gPzBL62mZ1lD148FSm-_y_ydd1LCu8o0On9dwDgPZsEvAF4K5kE1fNH3Y5KwfuBs-Fxt3tAnnbPSvnVnozCsOv-fMKKeQ6LqSEtJHkyY7ZbPpKajcVC9kfigveYcanBxH7dYkFSag7rGpZbckixmnnG2iLGty5SUl7_LTuYNW2ZtKUhtym6fo2moiMY0dacHD7vnnjTml_cz4vu55fPPy6v-5tvV18vP970lsmh9k7ByEelULr9SNErQ70VTsgRAIUdUFKPnO2tUM5Yjnbgjo6TlGJibEDKL7rX5941p98blqrnUCzGaBZMW9GUCyGUggaOZ9DmVEpGr9ccZpOPmoI-add32vXJqQbQd9o1b7lX9wdMsSb6bBYbykNYjAomdsI-nDFsnz0EzLrYgItFF3JTol0K_zn0F-fEmkg</recordid><startdate>1987</startdate><enddate>1987</enddate><creator>Scholz, Fritz</creator><creator>Nitschke, Lutz</creator><creator>Henrion, Günter</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QH</scope></search><sort><creationdate>1987</creationdate><title>Determination of mercury traces by differential-pulse stripping voltammetry after sorption of mercury vapour on a gold-plated electrode</title><author>Scholz, Fritz ; Nitschke, Lutz ; Henrion, Günter</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c284t-d9053599e8db51ef9a1fc7d78500e7c4e81fe32bc79dac3ec43d1568876224e13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1987</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Electrochemical methods</topic><topic>Exact sciences and technology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Scholz, Fritz</creatorcontrib><creatorcontrib>Nitschke, Lutz</creatorcontrib><creatorcontrib>Henrion, Günter</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Aqualine</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Scholz, Fritz</au><au>Nitschke, Lutz</au><au>Henrion, Günter</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of mercury traces by differential-pulse stripping voltammetry after sorption of mercury vapour on a gold-plated electrode</atitle><jtitle>Analytica chimica acta</jtitle><date>1987</date><risdate>1987</risdate><volume>199</volume><spage>167</spage><epage>171</epage><pages>167-171</pages><issn>0003-2670</issn><eissn>1873-4324</eissn><coden>ACACAM</coden><abstract>Trace mercury is reduced with tin(II) to mercury metal, which is volatilised by bubbling air through the solution. A certain fraction of this mercury is sorbed on a rotating gold disk electrode and stripped in a thiocyanate solution. The detection limit is about 30 ng Hg(II) in solution; the relative standard deviation is 6% for 100 ng Hg(II) (
n = 7). The detection limit for mercury in air is 1.7 ng l
−1 with a preconcentration time of 10 min.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/S0003-2670(00)82809-3</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2670 |
ispartof | Analytica chimica acta, 1987, Vol.199, p.167-171 |
issn | 0003-2670 1873-4324 |
language | eng |
recordid | cdi_proquest_miscellaneous_13777990 |
source | ScienceDirect Freedom Collection (Elsevier) |
subjects | Analytical chemistry Chemistry Electrochemical methods Exact sciences and technology |
title | Determination of mercury traces by differential-pulse stripping voltammetry after sorption of mercury vapour on a gold-plated electrode |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T06%3A41%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20mercury%20traces%20by%20differential-pulse%20stripping%20voltammetry%20after%20sorption%20of%20mercury%20vapour%20on%20a%20gold-plated%20electrode&rft.jtitle=Analytica%20chimica%20acta&rft.au=Scholz,%20Fritz&rft.date=1987&rft.volume=199&rft.spage=167&rft.epage=171&rft.pages=167-171&rft.issn=0003-2670&rft.eissn=1873-4324&rft.coden=ACACAM&rft_id=info:doi/10.1016/S0003-2670(00)82809-3&rft_dat=%3Cproquest_cross%3E13777990%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=13777990&rft_id=info:pmid/&rft_els_id=S0003267000828093&rfr_iscdi=true |