Clinical Utility of Positron Emission Mammography
Several imaging modalities have been introduced over recent years to better screen for and stage breast cancer. Positron emission mammography (PEM) has been approved by the US Food and Drug Administration and introduced into clinical use as a diagnostic adjunct to mammography and breast ultrasonogra...
Gespeichert in:
Veröffentlicht in: | Proceedings - Baylor University. Medical Center 2013-07, Vol.26 (3), p.314-319 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 319 |
---|---|
container_issue | 3 |
container_start_page | 314 |
container_title | Proceedings - Baylor University. Medical Center |
container_volume | 26 |
creator | Glass, Shannon B. Shah, Zeeshan A. |
description | Several imaging modalities have been introduced over recent years to better screen for and stage breast cancer. Positron emission mammography (PEM) has been approved by the US Food and Drug Administration and introduced into clinical use as a diagnostic adjunct to mammography and breast ultrasonography. PEM has higher resolution and a more localized field of view than positron emission tomography-computed tomography and can be performed on patients to stage a newly diagnosed malignancy. Review of mammograms together with magnetic resonance or PEM images improves detection of disease. |
doi_str_mv | 10.1080/08998280.2013.11928996 |
format | Article |
fullrecord | <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_miscellaneous_1373441164</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A336177206</galeid><sourcerecordid>A336177206</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4786-42b585f7f2bf0eca15f6b4db501f18009fce914068508028fc5bed004f6642ad3</originalsourceid><addsrcrecordid>eNqFkV1rFDEUhoModq3-hbLgjTez5uRrMjfCstRWqOiFvQ6ZTLJNySRrMqvsvzfDdqsVQXKRcPKc93y8CF0AXgGW-D2WXSeJxCuCga4AOlID4hlaACe8oYST52gxQ81MnaFXpdxjzIBC-xKdESqBMUwWCDbBR290WN5OPvjpsExu-TUVP-UUl5ejL8XXx2c9jmmb9e7u8Bq9cDoU--bhPke3Hy-_ba6bmy9Xnzbrm8awVoqGkZ5L7lpHeoet0cCd6NnQcwwOJMadM7YDhoXkdR4ineG9HWqLTghG9EDP0Yej7m7fj3YwNk5ZB7XLftT5oJL26ulP9Hdqm34oKiSjuKsC7x4Ecvq-t2VSdRpjQ9DRpn1RQFvKGIBgFX37F3qf9jnW8SpVFw0YhPxNbXWwykeXal0zi6o1pQLalmBRqdU_qHoGO3qTonW-xp8kiGOCyamUbN3jjIDVbLY6ma1ms9XJ7Jp48eeGHtNO7lZgfQTmLvKof6YcBjXpQ0jZZR2NL4r-p8gvjFu2pg</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1399810168</pqid></control><display><type>article</type><title>Clinical Utility of Positron Emission Mammography</title><source>PubMed Central</source><source>EZB Electronic Journals Library</source><creator>Glass, Shannon B. ; Shah, Zeeshan A.</creator><creatorcontrib>Glass, Shannon B. ; Shah, Zeeshan A.</creatorcontrib><description>Several imaging modalities have been introduced over recent years to better screen for and stage breast cancer. Positron emission mammography (PEM) has been approved by the US Food and Drug Administration and introduced into clinical use as a diagnostic adjunct to mammography and breast ultrasonography. PEM has higher resolution and a more localized field of view than positron emission tomography-computed tomography and can be performed on patients to stage a newly diagnosed malignancy. Review of mammograms together with magnetic resonance or PEM images improves detection of disease.</description><identifier>ISSN: 0899-8280</identifier><identifier>EISSN: 1525-3252</identifier><identifier>DOI: 10.1080/08998280.2013.11928996</identifier><identifier>PMID: 23814402</identifier><language>eng</language><publisher>United States: Taylor & Francis</publisher><subject>Analysis ; Breast cancer ; Cancer ; Diagnosis ; Emission ; Health aspects ; Innovations ; Mammography ; Positrons</subject><ispartof>Proceedings - Baylor University. Medical Center, 2013-07, Vol.26 (3), p.314-319</ispartof><rights>Copyright © 2013 Baylor University Medical Center 2013</rights><rights>COPYRIGHT 2013 Taylor & Francis Group LLC</rights><rights>Copyright Baylor University Medical Center Jul 2013</rights><rights>Copyright © 2013, Baylor University Medical Center 2013</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4786-42b585f7f2bf0eca15f6b4db501f18009fce914068508028fc5bed004f6642ad3</citedby><cites>FETCH-LOGICAL-c4786-42b585f7f2bf0eca15f6b4db501f18009fce914068508028fc5bed004f6642ad3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3684309/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3684309/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23814402$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Glass, Shannon B.</creatorcontrib><creatorcontrib>Shah, Zeeshan A.</creatorcontrib><title>Clinical Utility of Positron Emission Mammography</title><title>Proceedings - Baylor University. Medical Center</title><addtitle>Proc (Bayl Univ Med Cent)</addtitle><description>Several imaging modalities have been introduced over recent years to better screen for and stage breast cancer. Positron emission mammography (PEM) has been approved by the US Food and Drug Administration and introduced into clinical use as a diagnostic adjunct to mammography and breast ultrasonography. PEM has higher resolution and a more localized field of view than positron emission tomography-computed tomography and can be performed on patients to stage a newly diagnosed malignancy. Review of mammograms together with magnetic resonance or PEM images improves detection of disease.</description><subject>Analysis</subject><subject>Breast cancer</subject><subject>Cancer</subject><subject>Diagnosis</subject><subject>Emission</subject><subject>Health aspects</subject><subject>Innovations</subject><subject>Mammography</subject><subject>Positrons</subject><issn>0899-8280</issn><issn>1525-3252</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><recordid>eNqFkV1rFDEUhoModq3-hbLgjTez5uRrMjfCstRWqOiFvQ6ZTLJNySRrMqvsvzfDdqsVQXKRcPKc93y8CF0AXgGW-D2WXSeJxCuCga4AOlID4hlaACe8oYST52gxQ81MnaFXpdxjzIBC-xKdESqBMUwWCDbBR290WN5OPvjpsExu-TUVP-UUl5ejL8XXx2c9jmmb9e7u8Bq9cDoU--bhPke3Hy-_ba6bmy9Xnzbrm8awVoqGkZ5L7lpHeoet0cCd6NnQcwwOJMadM7YDhoXkdR4ineG9HWqLTghG9EDP0Yej7m7fj3YwNk5ZB7XLftT5oJL26ulP9Hdqm34oKiSjuKsC7x4Ecvq-t2VSdRpjQ9DRpn1RQFvKGIBgFX37F3qf9jnW8SpVFw0YhPxNbXWwykeXal0zi6o1pQLalmBRqdU_qHoGO3qTonW-xp8kiGOCyamUbN3jjIDVbLY6ma1ms9XJ7Jp48eeGHtNO7lZgfQTmLvKof6YcBjXpQ0jZZR2NL4r-p8gvjFu2pg</recordid><startdate>20130701</startdate><enddate>20130701</enddate><creator>Glass, Shannon B.</creator><creator>Shah, Zeeshan A.</creator><general>Taylor & Francis</general><general>Taylor & Francis Group LLC</general><general>Taylor & Francis Ltd</general><general>Baylor Health Care System</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20130701</creationdate><title>Clinical Utility of Positron Emission Mammography</title><author>Glass, Shannon B. ; Shah, Zeeshan A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4786-42b585f7f2bf0eca15f6b4db501f18009fce914068508028fc5bed004f6642ad3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Analysis</topic><topic>Breast cancer</topic><topic>Cancer</topic><topic>Diagnosis</topic><topic>Emission</topic><topic>Health aspects</topic><topic>Innovations</topic><topic>Mammography</topic><topic>Positrons</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Glass, Shannon B.</creatorcontrib><creatorcontrib>Shah, Zeeshan A.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Proceedings - Baylor University. Medical Center</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Glass, Shannon B.</au><au>Shah, Zeeshan A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Clinical Utility of Positron Emission Mammography</atitle><jtitle>Proceedings - Baylor University. Medical Center</jtitle><addtitle>Proc (Bayl Univ Med Cent)</addtitle><date>2013-07-01</date><risdate>2013</risdate><volume>26</volume><issue>3</issue><spage>314</spage><epage>319</epage><pages>314-319</pages><issn>0899-8280</issn><eissn>1525-3252</eissn><abstract>Several imaging modalities have been introduced over recent years to better screen for and stage breast cancer. Positron emission mammography (PEM) has been approved by the US Food and Drug Administration and introduced into clinical use as a diagnostic adjunct to mammography and breast ultrasonography. PEM has higher resolution and a more localized field of view than positron emission tomography-computed tomography and can be performed on patients to stage a newly diagnosed malignancy. Review of mammograms together with magnetic resonance or PEM images improves detection of disease.</abstract><cop>United States</cop><pub>Taylor & Francis</pub><pmid>23814402</pmid><doi>10.1080/08998280.2013.11928996</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0899-8280 |
ispartof | Proceedings - Baylor University. Medical Center, 2013-07, Vol.26 (3), p.314-319 |
issn | 0899-8280 1525-3252 |
language | eng |
recordid | cdi_proquest_miscellaneous_1373441164 |
source | PubMed Central; EZB Electronic Journals Library |
subjects | Analysis Breast cancer Cancer Diagnosis Emission Health aspects Innovations Mammography Positrons |
title | Clinical Utility of Positron Emission Mammography |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T19%3A03%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Clinical%20Utility%20of%20Positron%20Emission%20Mammography&rft.jtitle=Proceedings%20-%20Baylor%20University.%20Medical%20Center&rft.au=Glass,%20Shannon%20B.&rft.date=2013-07-01&rft.volume=26&rft.issue=3&rft.spage=314&rft.epage=319&rft.pages=314-319&rft.issn=0899-8280&rft.eissn=1525-3252&rft_id=info:doi/10.1080/08998280.2013.11928996&rft_dat=%3Cgale_proqu%3EA336177206%3C/gale_proqu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1399810168&rft_id=info:pmid/23814402&rft_galeid=A336177206&rfr_iscdi=true |