Abdominopelvic and lower extremity deep venous thrombosis: evaluation with contrast-enhanced MR venography with a blood-pool agent

The purpose of this article is to evaluate contrast-enhanced (CE) MR venography (MRV) with a blood-pool agent for detection of abdominopelvic and lower extremity deep venous thrombosis (DVT) compared with a conventional unenhanced gradient-recalled echo (GRE) MRV technique. This retrospective study...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of roentgenology (1976) 2013-07, Vol.201 (1), p.208-214
Hauptverfasser: Huang, Steven Y, Kim, Charles Y, Miller, Michael J, Gupta, Rajan T, Lessne, Mark L, Horvath, Jeffrey J, Boll, Daniel T, Evans, Paul D, Befera, Nicholas T, Krishnan, Pranay, Chan, Johanna L, Merkle, Elmar M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 214
container_issue 1
container_start_page 208
container_title American journal of roentgenology (1976)
container_volume 201
creator Huang, Steven Y
Kim, Charles Y
Miller, Michael J
Gupta, Rajan T
Lessne, Mark L
Horvath, Jeffrey J
Boll, Daniel T
Evans, Paul D
Befera, Nicholas T
Krishnan, Pranay
Chan, Johanna L
Merkle, Elmar M
description The purpose of this article is to evaluate contrast-enhanced (CE) MR venography (MRV) with a blood-pool agent for detection of abdominopelvic and lower extremity deep venous thrombosis (DVT) compared with a conventional unenhanced gradient-recalled echo (GRE) MRV technique. This retrospective study was performed on 30 patients (mean age, 52.7 years; 15 men and 15 women) referred for MRV between March 2010 and November 2010 for evaluation of lower extremity or abdominopelvic DVT. All patients underwent a GRE sequence followed by a CE T1-weighted sequence with gadofosveset, a blood-pool agent. The abdominopelvic and lower extremity venous system was divided into 13 segments. The presence of acute or chronic DVT was assessed by six radiologists, as well as qualitative and quantitative assessments of each venous segment. Image acquisition and interpretation times were also tabulated. The sensitivity and specificity for acute DVT were 91.0% and 99.8%, respectively, on CE MRV compared with 80.8% and 95.8%, respectively, on GRE MRV (p = 0.077 and p < 0.001). The sensitivity and specificity for chronic DVT were 84.4% and 98.4%, respectively, on CE MRV and 64.5% and 95.6%, respectively, on GRE MRV (p < 0.001 for both). Subjective ratings of vein visualization, signal homogeneity, and confidence pertaining to DVT diagnosis were significantly higher with the CE images (p < 0.001). The contrast-to-noise ratio for CE images was similar or significantly higher for all venous segments. Image acquisition and radiologist interpretation times on the CE studies were decreased (p < 0.001). Gadofosveset-enhanced MRV had equal or higher sensitivity and specificity for detection of DVT than did GRE MRV, with decreased time for image acquisition and interpretation.
doi_str_mv 10.2214/AJR.12.9611
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1371267595</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1371267595</sourcerecordid><originalsourceid>FETCH-LOGICAL-c289t-f5f2fd13898a64d2a14958d1af5330e85e55d747795270988a3a11c91ff105a83</originalsourceid><addsrcrecordid>eNo9kEFv1DAQhS0EotvCiTvyEQll8dhxbHNbVVBARUgVSNyi2XjSDUrsYHu37JVfTsoWTm8O3zzpfYy9ALGWEuo3m083a5Br1wA8YivQdVMpqOExWwnVQGWF-n7GznP-IYQw1pmn7Eyq5WiMWbHfm62P0xDiTONh6DgGz8d4R4nTr5JoGsqRe6KZHyjEfeZll-K0jXnIbzkdcNxjGWLgd0PZ8S6GkjCXisIOQ0eef775-3ebcN4dTxDy7Rijr-YYR463FMoz9qTHMdPzh7xg396_-3r5obr-cvXxcnNdddK6UvW6l70HZZ3FpvYSoXbaesBeKyXIatLam9oYp6URzlpUCNA56HsQGq26YK9OvXOKP_eUSzsNuaNxxEDLtBaUAdkY7fSCvj6hXYo5J-rbOQ0TpmMLor2X3i7SW5DtvfSFfvlQvN9O5P-z_yyrP52afqs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1371267595</pqid></control><display><type>article</type><title>Abdominopelvic and lower extremity deep venous thrombosis: evaluation with contrast-enhanced MR venography with a blood-pool agent</title><source>American Roentgen Ray Society</source><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Huang, Steven Y ; Kim, Charles Y ; Miller, Michael J ; Gupta, Rajan T ; Lessne, Mark L ; Horvath, Jeffrey J ; Boll, Daniel T ; Evans, Paul D ; Befera, Nicholas T ; Krishnan, Pranay ; Chan, Johanna L ; Merkle, Elmar M</creator><creatorcontrib>Huang, Steven Y ; Kim, Charles Y ; Miller, Michael J ; Gupta, Rajan T ; Lessne, Mark L ; Horvath, Jeffrey J ; Boll, Daniel T ; Evans, Paul D ; Befera, Nicholas T ; Krishnan, Pranay ; Chan, Johanna L ; Merkle, Elmar M</creatorcontrib><description>The purpose of this article is to evaluate contrast-enhanced (CE) MR venography (MRV) with a blood-pool agent for detection of abdominopelvic and lower extremity deep venous thrombosis (DVT) compared with a conventional unenhanced gradient-recalled echo (GRE) MRV technique. This retrospective study was performed on 30 patients (mean age, 52.7 years; 15 men and 15 women) referred for MRV between March 2010 and November 2010 for evaluation of lower extremity or abdominopelvic DVT. All patients underwent a GRE sequence followed by a CE T1-weighted sequence with gadofosveset, a blood-pool agent. The abdominopelvic and lower extremity venous system was divided into 13 segments. The presence of acute or chronic DVT was assessed by six radiologists, as well as qualitative and quantitative assessments of each venous segment. Image acquisition and interpretation times were also tabulated. The sensitivity and specificity for acute DVT were 91.0% and 99.8%, respectively, on CE MRV compared with 80.8% and 95.8%, respectively, on GRE MRV (p = 0.077 and p &lt; 0.001). The sensitivity and specificity for chronic DVT were 84.4% and 98.4%, respectively, on CE MRV and 64.5% and 95.6%, respectively, on GRE MRV (p &lt; 0.001 for both). Subjective ratings of vein visualization, signal homogeneity, and confidence pertaining to DVT diagnosis were significantly higher with the CE images (p &lt; 0.001). The contrast-to-noise ratio for CE images was similar or significantly higher for all venous segments. Image acquisition and radiologist interpretation times on the CE studies were decreased (p &lt; 0.001). Gadofosveset-enhanced MRV had equal or higher sensitivity and specificity for detection of DVT than did GRE MRV, with decreased time for image acquisition and interpretation.</description><identifier>ISSN: 0361-803X</identifier><identifier>EISSN: 1546-3141</identifier><identifier>DOI: 10.2214/AJR.12.9611</identifier><identifier>PMID: 23789677</identifier><language>eng</language><publisher>United States</publisher><subject>Abdomen - blood supply ; Adolescent ; Adult ; Aged ; Contrast Media ; Female ; Gadolinium ; Glomerular Filtration Rate ; Humans ; Leg - blood supply ; Magnetic Resonance Angiography - methods ; Male ; Middle Aged ; Organometallic Compounds ; Retrospective Studies ; Sensitivity and Specificity ; Venous Thrombosis - diagnosis</subject><ispartof>American journal of roentgenology (1976), 2013-07, Vol.201 (1), p.208-214</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c289t-f5f2fd13898a64d2a14958d1af5330e85e55d747795270988a3a11c91ff105a83</citedby><cites>FETCH-LOGICAL-c289t-f5f2fd13898a64d2a14958d1af5330e85e55d747795270988a3a11c91ff105a83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,4106,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23789677$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Huang, Steven Y</creatorcontrib><creatorcontrib>Kim, Charles Y</creatorcontrib><creatorcontrib>Miller, Michael J</creatorcontrib><creatorcontrib>Gupta, Rajan T</creatorcontrib><creatorcontrib>Lessne, Mark L</creatorcontrib><creatorcontrib>Horvath, Jeffrey J</creatorcontrib><creatorcontrib>Boll, Daniel T</creatorcontrib><creatorcontrib>Evans, Paul D</creatorcontrib><creatorcontrib>Befera, Nicholas T</creatorcontrib><creatorcontrib>Krishnan, Pranay</creatorcontrib><creatorcontrib>Chan, Johanna L</creatorcontrib><creatorcontrib>Merkle, Elmar M</creatorcontrib><title>Abdominopelvic and lower extremity deep venous thrombosis: evaluation with contrast-enhanced MR venography with a blood-pool agent</title><title>American journal of roentgenology (1976)</title><addtitle>AJR Am J Roentgenol</addtitle><description>The purpose of this article is to evaluate contrast-enhanced (CE) MR venography (MRV) with a blood-pool agent for detection of abdominopelvic and lower extremity deep venous thrombosis (DVT) compared with a conventional unenhanced gradient-recalled echo (GRE) MRV technique. This retrospective study was performed on 30 patients (mean age, 52.7 years; 15 men and 15 women) referred for MRV between March 2010 and November 2010 for evaluation of lower extremity or abdominopelvic DVT. All patients underwent a GRE sequence followed by a CE T1-weighted sequence with gadofosveset, a blood-pool agent. The abdominopelvic and lower extremity venous system was divided into 13 segments. The presence of acute or chronic DVT was assessed by six radiologists, as well as qualitative and quantitative assessments of each venous segment. Image acquisition and interpretation times were also tabulated. The sensitivity and specificity for acute DVT were 91.0% and 99.8%, respectively, on CE MRV compared with 80.8% and 95.8%, respectively, on GRE MRV (p = 0.077 and p &lt; 0.001). The sensitivity and specificity for chronic DVT were 84.4% and 98.4%, respectively, on CE MRV and 64.5% and 95.6%, respectively, on GRE MRV (p &lt; 0.001 for both). Subjective ratings of vein visualization, signal homogeneity, and confidence pertaining to DVT diagnosis were significantly higher with the CE images (p &lt; 0.001). The contrast-to-noise ratio for CE images was similar or significantly higher for all venous segments. Image acquisition and radiologist interpretation times on the CE studies were decreased (p &lt; 0.001). Gadofosveset-enhanced MRV had equal or higher sensitivity and specificity for detection of DVT than did GRE MRV, with decreased time for image acquisition and interpretation.</description><subject>Abdomen - blood supply</subject><subject>Adolescent</subject><subject>Adult</subject><subject>Aged</subject><subject>Contrast Media</subject><subject>Female</subject><subject>Gadolinium</subject><subject>Glomerular Filtration Rate</subject><subject>Humans</subject><subject>Leg - blood supply</subject><subject>Magnetic Resonance Angiography - methods</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Organometallic Compounds</subject><subject>Retrospective Studies</subject><subject>Sensitivity and Specificity</subject><subject>Venous Thrombosis - diagnosis</subject><issn>0361-803X</issn><issn>1546-3141</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kEFv1DAQhS0EotvCiTvyEQll8dhxbHNbVVBARUgVSNyi2XjSDUrsYHu37JVfTsoWTm8O3zzpfYy9ALGWEuo3m083a5Br1wA8YivQdVMpqOExWwnVQGWF-n7GznP-IYQw1pmn7Eyq5WiMWbHfm62P0xDiTONh6DgGz8d4R4nTr5JoGsqRe6KZHyjEfeZll-K0jXnIbzkdcNxjGWLgd0PZ8S6GkjCXisIOQ0eef775-3ebcN4dTxDy7Rijr-YYR463FMoz9qTHMdPzh7xg396_-3r5obr-cvXxcnNdddK6UvW6l70HZZ3FpvYSoXbaesBeKyXIatLam9oYp6URzlpUCNA56HsQGq26YK9OvXOKP_eUSzsNuaNxxEDLtBaUAdkY7fSCvj6hXYo5J-rbOQ0TpmMLor2X3i7SW5DtvfSFfvlQvN9O5P-z_yyrP52afqs</recordid><startdate>201307</startdate><enddate>201307</enddate><creator>Huang, Steven Y</creator><creator>Kim, Charles Y</creator><creator>Miller, Michael J</creator><creator>Gupta, Rajan T</creator><creator>Lessne, Mark L</creator><creator>Horvath, Jeffrey J</creator><creator>Boll, Daniel T</creator><creator>Evans, Paul D</creator><creator>Befera, Nicholas T</creator><creator>Krishnan, Pranay</creator><creator>Chan, Johanna L</creator><creator>Merkle, Elmar M</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201307</creationdate><title>Abdominopelvic and lower extremity deep venous thrombosis: evaluation with contrast-enhanced MR venography with a blood-pool agent</title><author>Huang, Steven Y ; Kim, Charles Y ; Miller, Michael J ; Gupta, Rajan T ; Lessne, Mark L ; Horvath, Jeffrey J ; Boll, Daniel T ; Evans, Paul D ; Befera, Nicholas T ; Krishnan, Pranay ; Chan, Johanna L ; Merkle, Elmar M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c289t-f5f2fd13898a64d2a14958d1af5330e85e55d747795270988a3a11c91ff105a83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Abdomen - blood supply</topic><topic>Adolescent</topic><topic>Adult</topic><topic>Aged</topic><topic>Contrast Media</topic><topic>Female</topic><topic>Gadolinium</topic><topic>Glomerular Filtration Rate</topic><topic>Humans</topic><topic>Leg - blood supply</topic><topic>Magnetic Resonance Angiography - methods</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Organometallic Compounds</topic><topic>Retrospective Studies</topic><topic>Sensitivity and Specificity</topic><topic>Venous Thrombosis - diagnosis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Huang, Steven Y</creatorcontrib><creatorcontrib>Kim, Charles Y</creatorcontrib><creatorcontrib>Miller, Michael J</creatorcontrib><creatorcontrib>Gupta, Rajan T</creatorcontrib><creatorcontrib>Lessne, Mark L</creatorcontrib><creatorcontrib>Horvath, Jeffrey J</creatorcontrib><creatorcontrib>Boll, Daniel T</creatorcontrib><creatorcontrib>Evans, Paul D</creatorcontrib><creatorcontrib>Befera, Nicholas T</creatorcontrib><creatorcontrib>Krishnan, Pranay</creatorcontrib><creatorcontrib>Chan, Johanna L</creatorcontrib><creatorcontrib>Merkle, Elmar M</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>American journal of roentgenology (1976)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Huang, Steven Y</au><au>Kim, Charles Y</au><au>Miller, Michael J</au><au>Gupta, Rajan T</au><au>Lessne, Mark L</au><au>Horvath, Jeffrey J</au><au>Boll, Daniel T</au><au>Evans, Paul D</au><au>Befera, Nicholas T</au><au>Krishnan, Pranay</au><au>Chan, Johanna L</au><au>Merkle, Elmar M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Abdominopelvic and lower extremity deep venous thrombosis: evaluation with contrast-enhanced MR venography with a blood-pool agent</atitle><jtitle>American journal of roentgenology (1976)</jtitle><addtitle>AJR Am J Roentgenol</addtitle><date>2013-07</date><risdate>2013</risdate><volume>201</volume><issue>1</issue><spage>208</spage><epage>214</epage><pages>208-214</pages><issn>0361-803X</issn><eissn>1546-3141</eissn><abstract>The purpose of this article is to evaluate contrast-enhanced (CE) MR venography (MRV) with a blood-pool agent for detection of abdominopelvic and lower extremity deep venous thrombosis (DVT) compared with a conventional unenhanced gradient-recalled echo (GRE) MRV technique. This retrospective study was performed on 30 patients (mean age, 52.7 years; 15 men and 15 women) referred for MRV between March 2010 and November 2010 for evaluation of lower extremity or abdominopelvic DVT. All patients underwent a GRE sequence followed by a CE T1-weighted sequence with gadofosveset, a blood-pool agent. The abdominopelvic and lower extremity venous system was divided into 13 segments. The presence of acute or chronic DVT was assessed by six radiologists, as well as qualitative and quantitative assessments of each venous segment. Image acquisition and interpretation times were also tabulated. The sensitivity and specificity for acute DVT were 91.0% and 99.8%, respectively, on CE MRV compared with 80.8% and 95.8%, respectively, on GRE MRV (p = 0.077 and p &lt; 0.001). The sensitivity and specificity for chronic DVT were 84.4% and 98.4%, respectively, on CE MRV and 64.5% and 95.6%, respectively, on GRE MRV (p &lt; 0.001 for both). Subjective ratings of vein visualization, signal homogeneity, and confidence pertaining to DVT diagnosis were significantly higher with the CE images (p &lt; 0.001). The contrast-to-noise ratio for CE images was similar or significantly higher for all venous segments. Image acquisition and radiologist interpretation times on the CE studies were decreased (p &lt; 0.001). Gadofosveset-enhanced MRV had equal or higher sensitivity and specificity for detection of DVT than did GRE MRV, with decreased time for image acquisition and interpretation.</abstract><cop>United States</cop><pmid>23789677</pmid><doi>10.2214/AJR.12.9611</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0361-803X
ispartof American journal of roentgenology (1976), 2013-07, Vol.201 (1), p.208-214
issn 0361-803X
1546-3141
language eng
recordid cdi_proquest_miscellaneous_1371267595
source American Roentgen Ray Society; MEDLINE; Alma/SFX Local Collection
subjects Abdomen - blood supply
Adolescent
Adult
Aged
Contrast Media
Female
Gadolinium
Glomerular Filtration Rate
Humans
Leg - blood supply
Magnetic Resonance Angiography - methods
Male
Middle Aged
Organometallic Compounds
Retrospective Studies
Sensitivity and Specificity
Venous Thrombosis - diagnosis
title Abdominopelvic and lower extremity deep venous thrombosis: evaluation with contrast-enhanced MR venography with a blood-pool agent
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-14T23%3A40%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Abdominopelvic%20and%20lower%20extremity%20deep%20venous%20thrombosis:%20evaluation%20with%20contrast-enhanced%20MR%20venography%20with%20a%20blood-pool%20agent&rft.jtitle=American%20journal%20of%20roentgenology%20(1976)&rft.au=Huang,%20Steven%20Y&rft.date=2013-07&rft.volume=201&rft.issue=1&rft.spage=208&rft.epage=214&rft.pages=208-214&rft.issn=0361-803X&rft.eissn=1546-3141&rft_id=info:doi/10.2214/AJR.12.9611&rft_dat=%3Cproquest_cross%3E1371267595%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1371267595&rft_id=info:pmid/23789677&rfr_iscdi=true