Proximal interphalangeal joint replacement with an unconstrained pyrocarbon prosthesis (Ascension®): a long-term follow-up
There have been limited publications that report long-term outcomes of pyrocarbon implants. This report describes both clinical and radiographic long-term results for patients who have been treated with pyrocarbon proximal interphalangeal implants. Thirteen implants in ten patients are reported for...
Gespeichert in:
Veröffentlicht in: | The Journal of hand surgery, European volume European volume, 2013-07, Vol.38 (6), p.680-685 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 685 |
---|---|
container_issue | 6 |
container_start_page | 680 |
container_title | The Journal of hand surgery, European volume |
container_volume | 38 |
creator | Heers, G. Springorum, H. R. Baier, C. Götz, J. Grifka, J. Renkawitz, T. |
description | There have been limited publications that report long-term outcomes of pyrocarbon implants. This report describes both clinical and radiographic long-term results for patients who have been treated with pyrocarbon proximal interphalangeal implants. Thirteen implants in ten patients are reported for an average follow-up of 8.3 years (range 6.2–9.3). All patients were suffering from degenerative joint disease. Five of the 13 digits were free of pain, the remaining eight digits had mild to moderate pain (visual analogue scale 2–5). The average active range of motion was 58° (SD 19°) at latest examination. X-ray results were unremarkable in six digits with an acceptable position of the prosthesis. However, in seven patients significant radiolucent lines (≥ 1 mm) were observed. Three prostheses demonstrated a migration of the proximal component, and one a subsidence of the distal component. Our study does not support the use of this implant for treatment of osteoarthritis of the finger joint owing to high complication rates and limited range of motion. |
doi_str_mv | 10.1177/1753193412469898 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1370122985</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1753193412469898</sage_id><sourcerecordid>1370122985</sourcerecordid><originalsourceid>FETCH-LOGICAL-c379t-91b70ae0e20af6170915ae3764786bb48b060a2ecd1e4fa4021a734893d9d30c3</originalsourceid><addsrcrecordid>eNp1UMtOwzAQtBCIlsKdE_IRDgG_EsfcqoqXhAQHOEdOsmlTJXawE5WKf-Ij-DJctXBA4rSv2dmdQeiUkktKpbyiMuZUcUGZSFSq0j00ZkTwKGGp2kfjzTjazEfoyPslIXGqaHKIRowzLmQSj9HHs7PvdasbXJseXLfQjTZzCPXShg520DW6gBZCvqr7BdYGD6awxvdO1wZK3K2dLbTLrcGds75fgK89Pp_6Aoyvrfn6vLjGGjfWzKNwocWVbRq7iobuGB1UuvFwsosT9Hp78zK7jx6f7h5m08eo4FL1kaK5JBoIMKKrhEqiaKyBy0TINMlzkeYkIZpBUVIQlRaEUS25SBUvVclJwSfofMsb_nsbwPdZW4fvmqAU7OAzyiWhjKk0DlCyhRZBindQZZ0L7rh1Rkm2sTz7a3lYOduxD3kL5e_Cj8cBEG0BXs8hW9rBmaD2f8JvRGyLcw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1370122985</pqid></control><display><type>article</type><title>Proximal interphalangeal joint replacement with an unconstrained pyrocarbon prosthesis (Ascension®): a long-term follow-up</title><source>MEDLINE</source><source>SAGE Complete</source><source>Alma/SFX Local Collection</source><creator>Heers, G. ; Springorum, H. R. ; Baier, C. ; Götz, J. ; Grifka, J. ; Renkawitz, T.</creator><creatorcontrib>Heers, G. ; Springorum, H. R. ; Baier, C. ; Götz, J. ; Grifka, J. ; Renkawitz, T.</creatorcontrib><description>There have been limited publications that report long-term outcomes of pyrocarbon implants. This report describes both clinical and radiographic long-term results for patients who have been treated with pyrocarbon proximal interphalangeal implants. Thirteen implants in ten patients are reported for an average follow-up of 8.3 years (range 6.2–9.3). All patients were suffering from degenerative joint disease. Five of the 13 digits were free of pain, the remaining eight digits had mild to moderate pain (visual analogue scale 2–5). The average active range of motion was 58° (SD 19°) at latest examination. X-ray results were unremarkable in six digits with an acceptable position of the prosthesis. However, in seven patients significant radiolucent lines (≥ 1 mm) were observed. Three prostheses demonstrated a migration of the proximal component, and one a subsidence of the distal component. Our study does not support the use of this implant for treatment of osteoarthritis of the finger joint owing to high complication rates and limited range of motion.</description><identifier>ISSN: 1753-1934</identifier><identifier>EISSN: 2043-6289</identifier><identifier>DOI: 10.1177/1753193412469898</identifier><identifier>PMID: 23234765</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Aged ; Arthroplasty, Replacement, Finger - instrumentation ; Carbon ; Finger Joint - surgery ; Follow-Up Studies ; Humans ; Joint Prosthesis ; Middle Aged ; Osteoarthritis - surgery ; Range of Motion, Articular ; Visual Analog Scale</subject><ispartof>The Journal of hand surgery, European volume, 2013-07, Vol.38 (6), p.680-685</ispartof><rights>The Author(s) 2012</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c379t-91b70ae0e20af6170915ae3764786bb48b060a2ecd1e4fa4021a734893d9d30c3</citedby><cites>FETCH-LOGICAL-c379t-91b70ae0e20af6170915ae3764786bb48b060a2ecd1e4fa4021a734893d9d30c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/1753193412469898$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/1753193412469898$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,776,780,21798,27901,27902,43597,43598</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23234765$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Heers, G.</creatorcontrib><creatorcontrib>Springorum, H. R.</creatorcontrib><creatorcontrib>Baier, C.</creatorcontrib><creatorcontrib>Götz, J.</creatorcontrib><creatorcontrib>Grifka, J.</creatorcontrib><creatorcontrib>Renkawitz, T.</creatorcontrib><title>Proximal interphalangeal joint replacement with an unconstrained pyrocarbon prosthesis (Ascension®): a long-term follow-up</title><title>The Journal of hand surgery, European volume</title><addtitle>J Hand Surg Eur Vol</addtitle><description>There have been limited publications that report long-term outcomes of pyrocarbon implants. This report describes both clinical and radiographic long-term results for patients who have been treated with pyrocarbon proximal interphalangeal implants. Thirteen implants in ten patients are reported for an average follow-up of 8.3 years (range 6.2–9.3). All patients were suffering from degenerative joint disease. Five of the 13 digits were free of pain, the remaining eight digits had mild to moderate pain (visual analogue scale 2–5). The average active range of motion was 58° (SD 19°) at latest examination. X-ray results were unremarkable in six digits with an acceptable position of the prosthesis. However, in seven patients significant radiolucent lines (≥ 1 mm) were observed. Three prostheses demonstrated a migration of the proximal component, and one a subsidence of the distal component. Our study does not support the use of this implant for treatment of osteoarthritis of the finger joint owing to high complication rates and limited range of motion.</description><subject>Aged</subject><subject>Arthroplasty, Replacement, Finger - instrumentation</subject><subject>Carbon</subject><subject>Finger Joint - surgery</subject><subject>Follow-Up Studies</subject><subject>Humans</subject><subject>Joint Prosthesis</subject><subject>Middle Aged</subject><subject>Osteoarthritis - surgery</subject><subject>Range of Motion, Articular</subject><subject>Visual Analog Scale</subject><issn>1753-1934</issn><issn>2043-6289</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1UMtOwzAQtBCIlsKdE_IRDgG_EsfcqoqXhAQHOEdOsmlTJXawE5WKf-Ij-DJctXBA4rSv2dmdQeiUkktKpbyiMuZUcUGZSFSq0j00ZkTwKGGp2kfjzTjazEfoyPslIXGqaHKIRowzLmQSj9HHs7PvdasbXJseXLfQjTZzCPXShg520DW6gBZCvqr7BdYGD6awxvdO1wZK3K2dLbTLrcGds75fgK89Pp_6Aoyvrfn6vLjGGjfWzKNwocWVbRq7iobuGB1UuvFwsosT9Hp78zK7jx6f7h5m08eo4FL1kaK5JBoIMKKrhEqiaKyBy0TINMlzkeYkIZpBUVIQlRaEUS25SBUvVclJwSfofMsb_nsbwPdZW4fvmqAU7OAzyiWhjKk0DlCyhRZBindQZZ0L7rh1Rkm2sTz7a3lYOduxD3kL5e_Cj8cBEG0BXs8hW9rBmaD2f8JvRGyLcw</recordid><startdate>201307</startdate><enddate>201307</enddate><creator>Heers, G.</creator><creator>Springorum, H. R.</creator><creator>Baier, C.</creator><creator>Götz, J.</creator><creator>Grifka, J.</creator><creator>Renkawitz, T.</creator><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201307</creationdate><title>Proximal interphalangeal joint replacement with an unconstrained pyrocarbon prosthesis (Ascension®): a long-term follow-up</title><author>Heers, G. ; Springorum, H. R. ; Baier, C. ; Götz, J. ; Grifka, J. ; Renkawitz, T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c379t-91b70ae0e20af6170915ae3764786bb48b060a2ecd1e4fa4021a734893d9d30c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Aged</topic><topic>Arthroplasty, Replacement, Finger - instrumentation</topic><topic>Carbon</topic><topic>Finger Joint - surgery</topic><topic>Follow-Up Studies</topic><topic>Humans</topic><topic>Joint Prosthesis</topic><topic>Middle Aged</topic><topic>Osteoarthritis - surgery</topic><topic>Range of Motion, Articular</topic><topic>Visual Analog Scale</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Heers, G.</creatorcontrib><creatorcontrib>Springorum, H. R.</creatorcontrib><creatorcontrib>Baier, C.</creatorcontrib><creatorcontrib>Götz, J.</creatorcontrib><creatorcontrib>Grifka, J.</creatorcontrib><creatorcontrib>Renkawitz, T.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of hand surgery, European volume</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Heers, G.</au><au>Springorum, H. R.</au><au>Baier, C.</au><au>Götz, J.</au><au>Grifka, J.</au><au>Renkawitz, T.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Proximal interphalangeal joint replacement with an unconstrained pyrocarbon prosthesis (Ascension®): a long-term follow-up</atitle><jtitle>The Journal of hand surgery, European volume</jtitle><addtitle>J Hand Surg Eur Vol</addtitle><date>2013-07</date><risdate>2013</risdate><volume>38</volume><issue>6</issue><spage>680</spage><epage>685</epage><pages>680-685</pages><issn>1753-1934</issn><eissn>2043-6289</eissn><abstract>There have been limited publications that report long-term outcomes of pyrocarbon implants. This report describes both clinical and radiographic long-term results for patients who have been treated with pyrocarbon proximal interphalangeal implants. Thirteen implants in ten patients are reported for an average follow-up of 8.3 years (range 6.2–9.3). All patients were suffering from degenerative joint disease. Five of the 13 digits were free of pain, the remaining eight digits had mild to moderate pain (visual analogue scale 2–5). The average active range of motion was 58° (SD 19°) at latest examination. X-ray results were unremarkable in six digits with an acceptable position of the prosthesis. However, in seven patients significant radiolucent lines (≥ 1 mm) were observed. Three prostheses demonstrated a migration of the proximal component, and one a subsidence of the distal component. Our study does not support the use of this implant for treatment of osteoarthritis of the finger joint owing to high complication rates and limited range of motion.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>23234765</pmid><doi>10.1177/1753193412469898</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1753-1934 |
ispartof | The Journal of hand surgery, European volume, 2013-07, Vol.38 (6), p.680-685 |
issn | 1753-1934 2043-6289 |
language | eng |
recordid | cdi_proquest_miscellaneous_1370122985 |
source | MEDLINE; SAGE Complete; Alma/SFX Local Collection |
subjects | Aged Arthroplasty, Replacement, Finger - instrumentation Carbon Finger Joint - surgery Follow-Up Studies Humans Joint Prosthesis Middle Aged Osteoarthritis - surgery Range of Motion, Articular Visual Analog Scale |
title | Proximal interphalangeal joint replacement with an unconstrained pyrocarbon prosthesis (Ascension®): a long-term follow-up |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T17%3A18%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Proximal%20interphalangeal%20joint%20replacement%20with%20an%20unconstrained%20pyrocarbon%20prosthesis%20(Ascension%C2%AE):%20a%20long-term%20follow-up&rft.jtitle=The%20Journal%20of%20hand%20surgery,%20European%20volume&rft.au=Heers,%20G.&rft.date=2013-07&rft.volume=38&rft.issue=6&rft.spage=680&rft.epage=685&rft.pages=680-685&rft.issn=1753-1934&rft.eissn=2043-6289&rft_id=info:doi/10.1177/1753193412469898&rft_dat=%3Cproquest_cross%3E1370122985%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1370122985&rft_id=info:pmid/23234765&rft_sage_id=10.1177_1753193412469898&rfr_iscdi=true |