Innovative P-wave detection for discrimination between ventricular and supraventricular tachycardia in single-chamber ICDs: is the P-wave invisible during tachycardia?

Differentiation between supraventricular tachycardia (SVT) and ventricular tachycardia (VT) remains a substantial clinical challenge in patients with single-chamber implantable cardioverter-defibrillators (ICDs) due to absence of visible P waves. Innovative optimization of intrathoracic electrogram...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Europace (London, England) England), 2013-06, Vol.15 (6), p.827-834
Hauptverfasser: Xiong, Will W, Karam, Pascal Y, Marsh, James D, Varma, Niraj, Verdino, Ralph J, Paydak, Hakan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 834
container_issue 6
container_start_page 827
container_title Europace (London, England)
container_volume 15
creator Xiong, Will W
Karam, Pascal Y
Marsh, James D
Varma, Niraj
Verdino, Ralph J
Paydak, Hakan
description Differentiation between supraventricular tachycardia (SVT) and ventricular tachycardia (VT) remains a substantial clinical challenge in patients with single-chamber implantable cardioverter-defibrillators (ICDs) due to absence of visible P waves. Innovative optimization of intrathoracic electrogram (EGM) configuration will facilitate P-wave detection and rhythm differentiation during tachycardia. Innovative optimization of EGM configuration was originally performed to improve patient care. In this retrospective cohort study, we examined our database for records of 140 consecutive patients undergoing single-chamber ICD implantation. During the follow-ups of 61 included patients with optimized EGM configuration, 27 patients were identified to have VT and/or SVT. EGMs in the Can (generator) to superior vena cava (Can-SVC) configuration were compared with those conventionally from the Can to right ventricular coil (Can-RV coil) source in the same patients. In Can-SVC EGMs, the ratio of P/QRS amplitude was 14-fold higher (0.57 ± 0.08 vs. 0.04 ± 0.00, P < 0.001) compared with those in Can-RV coil EGMs during sinus rhythm. With Can-SVC configuration, the odds of atrioventricular dissociation detection in patients with VT was increased 15-fold (61.9% vs. 9.5% with Can-RV coil; odds ratio, 15.4; 95% confidence interval, 2.8 to 84.7; P = 0.0009). In patients with SVT, P-waves or retrograde P-waves were markedly more identifiable in Can-SVC configuration compared with Can-RV coil (odds ratio, 40; 95% confidence interval, 3.6 to 447.1; P = 0.0010). P-wave recognition by optimizing EGM configuration provides a novel diagnostic tool for differentiation between VT and SVT in single-chamber ICDs. A potential discrimination algorithm would provide a cost-effective approach to improving the qualitative outcomes.
doi_str_mv 10.1093/europace/eus405
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1356393026</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1356393026</sourcerecordid><originalsourceid>FETCH-LOGICAL-c338t-e2e0e3358292a17c716bc358250c2fbdb0bb2cb73ddcc9a30806d7ff2c9417213</originalsourceid><addsrcrecordid>eNpNUctOwzAQtBCIR-HMDfnIJeBH3dRcECqvSpXgAOfIjw01SpxgO0V8Eb-JSwFx2tnR7OxqB6FjSs4okfwchtD1ykAGcUzEFtqngrOCEcm2MyZSFoIyuYcOYnwlhJRMil20x3hmqRD76HPufbdSya0APxbvKhcLCUxyncd1F7B10QTXOq--KQ3pHcDjFfgUnBkaFbDyFsehD-o_mZRZfhgVrFPYeRydf2mgMEvVagh4PruOF9hFnJZ_e51fueh0ky8YQpb_t7g8RDu1aiIc_dQRer69eZrdF4uHu_nsalEYzqepAAYEOBdTJpmipSnpRJt1K4hhtbaaaM2MLrm1xkjFyZRMbFnXzMgxLRnlI3S68e1D9zZATFWbHwBNozx0Q6woFxMuOWGTLD3fSE3oYgxQV31-lAofFSXVOp3qN51qk06eOPkxH3QL9k__Gwf_Aqujkpw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1356393026</pqid></control><display><type>article</type><title>Innovative P-wave detection for discrimination between ventricular and supraventricular tachycardia in single-chamber ICDs: is the P-wave invisible during tachycardia?</title><source>MEDLINE</source><source>Oxford Journals Open Access Collection</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Xiong, Will W ; Karam, Pascal Y ; Marsh, James D ; Varma, Niraj ; Verdino, Ralph J ; Paydak, Hakan</creator><creatorcontrib>Xiong, Will W ; Karam, Pascal Y ; Marsh, James D ; Varma, Niraj ; Verdino, Ralph J ; Paydak, Hakan</creatorcontrib><description>Differentiation between supraventricular tachycardia (SVT) and ventricular tachycardia (VT) remains a substantial clinical challenge in patients with single-chamber implantable cardioverter-defibrillators (ICDs) due to absence of visible P waves. Innovative optimization of intrathoracic electrogram (EGM) configuration will facilitate P-wave detection and rhythm differentiation during tachycardia. Innovative optimization of EGM configuration was originally performed to improve patient care. In this retrospective cohort study, we examined our database for records of 140 consecutive patients undergoing single-chamber ICD implantation. During the follow-ups of 61 included patients with optimized EGM configuration, 27 patients were identified to have VT and/or SVT. EGMs in the Can (generator) to superior vena cava (Can-SVC) configuration were compared with those conventionally from the Can to right ventricular coil (Can-RV coil) source in the same patients. In Can-SVC EGMs, the ratio of P/QRS amplitude was 14-fold higher (0.57 ± 0.08 vs. 0.04 ± 0.00, P &lt; 0.001) compared with those in Can-RV coil EGMs during sinus rhythm. With Can-SVC configuration, the odds of atrioventricular dissociation detection in patients with VT was increased 15-fold (61.9% vs. 9.5% with Can-RV coil; odds ratio, 15.4; 95% confidence interval, 2.8 to 84.7; P = 0.0009). In patients with SVT, P-waves or retrograde P-waves were markedly more identifiable in Can-SVC configuration compared with Can-RV coil (odds ratio, 40; 95% confidence interval, 3.6 to 447.1; P = 0.0010). P-wave recognition by optimizing EGM configuration provides a novel diagnostic tool for differentiation between VT and SVT in single-chamber ICDs. A potential discrimination algorithm would provide a cost-effective approach to improving the qualitative outcomes.</description><identifier>ISSN: 1099-5129</identifier><identifier>EISSN: 1532-2092</identifier><identifier>DOI: 10.1093/europace/eus405</identifier><identifier>PMID: 23512155</identifier><language>eng</language><publisher>England</publisher><subject>Algorithms ; Defibrillators, Implantable ; Diagnosis, Computer-Assisted - methods ; Diagnosis, Differential ; Electrocardiography - methods ; Female ; Humans ; Male ; Middle Aged ; Reproducibility of Results ; Retrospective Studies ; Sensitivity and Specificity ; Tachycardia, Supraventricular - diagnosis ; Tachycardia, Supraventricular - prevention &amp; control ; Tachycardia, Ventricular - diagnosis ; Tachycardia, Ventricular - prevention &amp; control ; Therapy, Computer-Assisted - methods ; Treatment Outcome</subject><ispartof>Europace (London, England), 2013-06, Vol.15 (6), p.827-834</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c338t-e2e0e3358292a17c716bc358250c2fbdb0bb2cb73ddcc9a30806d7ff2c9417213</citedby><cites>FETCH-LOGICAL-c338t-e2e0e3358292a17c716bc358250c2fbdb0bb2cb73ddcc9a30806d7ff2c9417213</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782,27907,27908</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23512155$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Xiong, Will W</creatorcontrib><creatorcontrib>Karam, Pascal Y</creatorcontrib><creatorcontrib>Marsh, James D</creatorcontrib><creatorcontrib>Varma, Niraj</creatorcontrib><creatorcontrib>Verdino, Ralph J</creatorcontrib><creatorcontrib>Paydak, Hakan</creatorcontrib><title>Innovative P-wave detection for discrimination between ventricular and supraventricular tachycardia in single-chamber ICDs: is the P-wave invisible during tachycardia?</title><title>Europace (London, England)</title><addtitle>Europace</addtitle><description>Differentiation between supraventricular tachycardia (SVT) and ventricular tachycardia (VT) remains a substantial clinical challenge in patients with single-chamber implantable cardioverter-defibrillators (ICDs) due to absence of visible P waves. Innovative optimization of intrathoracic electrogram (EGM) configuration will facilitate P-wave detection and rhythm differentiation during tachycardia. Innovative optimization of EGM configuration was originally performed to improve patient care. In this retrospective cohort study, we examined our database for records of 140 consecutive patients undergoing single-chamber ICD implantation. During the follow-ups of 61 included patients with optimized EGM configuration, 27 patients were identified to have VT and/or SVT. EGMs in the Can (generator) to superior vena cava (Can-SVC) configuration were compared with those conventionally from the Can to right ventricular coil (Can-RV coil) source in the same patients. In Can-SVC EGMs, the ratio of P/QRS amplitude was 14-fold higher (0.57 ± 0.08 vs. 0.04 ± 0.00, P &lt; 0.001) compared with those in Can-RV coil EGMs during sinus rhythm. With Can-SVC configuration, the odds of atrioventricular dissociation detection in patients with VT was increased 15-fold (61.9% vs. 9.5% with Can-RV coil; odds ratio, 15.4; 95% confidence interval, 2.8 to 84.7; P = 0.0009). In patients with SVT, P-waves or retrograde P-waves were markedly more identifiable in Can-SVC configuration compared with Can-RV coil (odds ratio, 40; 95% confidence interval, 3.6 to 447.1; P = 0.0010). P-wave recognition by optimizing EGM configuration provides a novel diagnostic tool for differentiation between VT and SVT in single-chamber ICDs. A potential discrimination algorithm would provide a cost-effective approach to improving the qualitative outcomes.</description><subject>Algorithms</subject><subject>Defibrillators, Implantable</subject><subject>Diagnosis, Computer-Assisted - methods</subject><subject>Diagnosis, Differential</subject><subject>Electrocardiography - methods</subject><subject>Female</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Reproducibility of Results</subject><subject>Retrospective Studies</subject><subject>Sensitivity and Specificity</subject><subject>Tachycardia, Supraventricular - diagnosis</subject><subject>Tachycardia, Supraventricular - prevention &amp; control</subject><subject>Tachycardia, Ventricular - diagnosis</subject><subject>Tachycardia, Ventricular - prevention &amp; control</subject><subject>Therapy, Computer-Assisted - methods</subject><subject>Treatment Outcome</subject><issn>1099-5129</issn><issn>1532-2092</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpNUctOwzAQtBCIR-HMDfnIJeBH3dRcECqvSpXgAOfIjw01SpxgO0V8Eb-JSwFx2tnR7OxqB6FjSs4okfwchtD1ykAGcUzEFtqngrOCEcm2MyZSFoIyuYcOYnwlhJRMil20x3hmqRD76HPufbdSya0APxbvKhcLCUxyncd1F7B10QTXOq--KQ3pHcDjFfgUnBkaFbDyFsehD-o_mZRZfhgVrFPYeRydf2mgMEvVagh4PruOF9hFnJZ_e51fueh0ky8YQpb_t7g8RDu1aiIc_dQRer69eZrdF4uHu_nsalEYzqepAAYEOBdTJpmipSnpRJt1K4hhtbaaaM2MLrm1xkjFyZRMbFnXzMgxLRnlI3S68e1D9zZATFWbHwBNozx0Q6woFxMuOWGTLD3fSE3oYgxQV31-lAofFSXVOp3qN51qk06eOPkxH3QL9k__Gwf_Aqujkpw</recordid><startdate>201306</startdate><enddate>201306</enddate><creator>Xiong, Will W</creator><creator>Karam, Pascal Y</creator><creator>Marsh, James D</creator><creator>Varma, Niraj</creator><creator>Verdino, Ralph J</creator><creator>Paydak, Hakan</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201306</creationdate><title>Innovative P-wave detection for discrimination between ventricular and supraventricular tachycardia in single-chamber ICDs: is the P-wave invisible during tachycardia?</title><author>Xiong, Will W ; Karam, Pascal Y ; Marsh, James D ; Varma, Niraj ; Verdino, Ralph J ; Paydak, Hakan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c338t-e2e0e3358292a17c716bc358250c2fbdb0bb2cb73ddcc9a30806d7ff2c9417213</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Algorithms</topic><topic>Defibrillators, Implantable</topic><topic>Diagnosis, Computer-Assisted - methods</topic><topic>Diagnosis, Differential</topic><topic>Electrocardiography - methods</topic><topic>Female</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Reproducibility of Results</topic><topic>Retrospective Studies</topic><topic>Sensitivity and Specificity</topic><topic>Tachycardia, Supraventricular - diagnosis</topic><topic>Tachycardia, Supraventricular - prevention &amp; control</topic><topic>Tachycardia, Ventricular - diagnosis</topic><topic>Tachycardia, Ventricular - prevention &amp; control</topic><topic>Therapy, Computer-Assisted - methods</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Xiong, Will W</creatorcontrib><creatorcontrib>Karam, Pascal Y</creatorcontrib><creatorcontrib>Marsh, James D</creatorcontrib><creatorcontrib>Varma, Niraj</creatorcontrib><creatorcontrib>Verdino, Ralph J</creatorcontrib><creatorcontrib>Paydak, Hakan</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Europace (London, England)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Xiong, Will W</au><au>Karam, Pascal Y</au><au>Marsh, James D</au><au>Varma, Niraj</au><au>Verdino, Ralph J</au><au>Paydak, Hakan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Innovative P-wave detection for discrimination between ventricular and supraventricular tachycardia in single-chamber ICDs: is the P-wave invisible during tachycardia?</atitle><jtitle>Europace (London, England)</jtitle><addtitle>Europace</addtitle><date>2013-06</date><risdate>2013</risdate><volume>15</volume><issue>6</issue><spage>827</spage><epage>834</epage><pages>827-834</pages><issn>1099-5129</issn><eissn>1532-2092</eissn><abstract>Differentiation between supraventricular tachycardia (SVT) and ventricular tachycardia (VT) remains a substantial clinical challenge in patients with single-chamber implantable cardioverter-defibrillators (ICDs) due to absence of visible P waves. Innovative optimization of intrathoracic electrogram (EGM) configuration will facilitate P-wave detection and rhythm differentiation during tachycardia. Innovative optimization of EGM configuration was originally performed to improve patient care. In this retrospective cohort study, we examined our database for records of 140 consecutive patients undergoing single-chamber ICD implantation. During the follow-ups of 61 included patients with optimized EGM configuration, 27 patients were identified to have VT and/or SVT. EGMs in the Can (generator) to superior vena cava (Can-SVC) configuration were compared with those conventionally from the Can to right ventricular coil (Can-RV coil) source in the same patients. In Can-SVC EGMs, the ratio of P/QRS amplitude was 14-fold higher (0.57 ± 0.08 vs. 0.04 ± 0.00, P &lt; 0.001) compared with those in Can-RV coil EGMs during sinus rhythm. With Can-SVC configuration, the odds of atrioventricular dissociation detection in patients with VT was increased 15-fold (61.9% vs. 9.5% with Can-RV coil; odds ratio, 15.4; 95% confidence interval, 2.8 to 84.7; P = 0.0009). In patients with SVT, P-waves or retrograde P-waves were markedly more identifiable in Can-SVC configuration compared with Can-RV coil (odds ratio, 40; 95% confidence interval, 3.6 to 447.1; P = 0.0010). P-wave recognition by optimizing EGM configuration provides a novel diagnostic tool for differentiation between VT and SVT in single-chamber ICDs. A potential discrimination algorithm would provide a cost-effective approach to improving the qualitative outcomes.</abstract><cop>England</cop><pmid>23512155</pmid><doi>10.1093/europace/eus405</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1099-5129
ispartof Europace (London, England), 2013-06, Vol.15 (6), p.827-834
issn 1099-5129
1532-2092
language eng
recordid cdi_proquest_miscellaneous_1356393026
source MEDLINE; Oxford Journals Open Access Collection; EZB-FREE-00999 freely available EZB journals; PubMed Central; Alma/SFX Local Collection
subjects Algorithms
Defibrillators, Implantable
Diagnosis, Computer-Assisted - methods
Diagnosis, Differential
Electrocardiography - methods
Female
Humans
Male
Middle Aged
Reproducibility of Results
Retrospective Studies
Sensitivity and Specificity
Tachycardia, Supraventricular - diagnosis
Tachycardia, Supraventricular - prevention & control
Tachycardia, Ventricular - diagnosis
Tachycardia, Ventricular - prevention & control
Therapy, Computer-Assisted - methods
Treatment Outcome
title Innovative P-wave detection for discrimination between ventricular and supraventricular tachycardia in single-chamber ICDs: is the P-wave invisible during tachycardia?
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T08%3A40%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Innovative%20P-wave%20detection%20for%20discrimination%20between%20ventricular%20and%20supraventricular%20tachycardia%20in%20single-chamber%20ICDs:%20is%20the%20P-wave%20invisible%20during%20tachycardia?&rft.jtitle=Europace%20(London,%20England)&rft.au=Xiong,%20Will%20W&rft.date=2013-06&rft.volume=15&rft.issue=6&rft.spage=827&rft.epage=834&rft.pages=827-834&rft.issn=1099-5129&rft.eissn=1532-2092&rft_id=info:doi/10.1093/europace/eus405&rft_dat=%3Cproquest_cross%3E1356393026%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1356393026&rft_id=info:pmid/23512155&rfr_iscdi=true