Structural damage evaluation of reinforced concrete beams exposed to high temperatures
The objective of this study is to investigate the effect of temperature distribution, concrete strength, cover thickness, and heating time on the structural behavior of reinforced concrete beams. Toward this goal, reinforced concrete beams with different concrete compressive strength and cover thick...
Gespeichert in:
Veröffentlicht in: | Journal of fire protection engineering 2013-05, Vol.23 (2), p.135-151 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 151 |
---|---|
container_issue | 2 |
container_start_page | 135 |
container_title | Journal of fire protection engineering |
container_volume | 23 |
creator | Choi, E. G. Shin, Y.-S. Kim, H. S. |
description | The objective of this study is to investigate the effect of temperature distribution, concrete strength, cover thickness, and heating time on the structural behavior of reinforced concrete beams. Toward this goal, reinforced concrete beams with different concrete compressive strength and cover thickness are fabricated and subjected to furnace heating for 60, 90, and 120min under a loaded state. In order to analyze structural behavior based on the thermal behavior of the beams, transient temperature distribution is measured during the furnace heating. After furnace heating, spalling is observed. From loading tests performed on the damaged reinforced concrete beams, residual strength, maximum loads, and beam deflections are measured and examined. The experimental results show that significant damage occurs in the reinforced concrete beams under high temperatures. In addition, it is found that thermal and structural behavior of damaged reinforced concrete beams is dependent on cover thickness and concrete strength and that most structural damage occurs in a relatively short period of heating time. Using these experimental findings, an equation is proposed that can be used to predict maximum load capacity and stiffness reduction ratio of the damaged reinforced concrete beams. |
doi_str_mv | 10.1177/1042391512474666 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1352288134</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1352288134</sourcerecordid><originalsourceid>FETCH-LOGICAL-c206t-fe9b1ba7d2593c239c59723648acfcc899c72919072f3ecc24ff2fe673b218f73</originalsourceid><addsrcrecordid>eNpdkM1LxDAQxYMouK7ePebopZpM2qY5yuIXLHjwA28lnZ3sVtqmJqnof29lPXmaYX6Px7zH2LkUl1JqfSVFDsrIQkKu87IsD9hCFgoyqeHtcN5nnP3yY3YS47sQQuXKLNjrUwoTpinYjm9sb7fE6dN2k02tH7h3PFA7OB-QNhz9gIES8YZsHzl9jT7O5-T5rt3ueKJ-pGBnL4qn7MjZLtLZ31yyl9ub59V9tn68e1hdrzMEUabMkWlkY_UGCqNw_h8Lo0GVeWXRIVbGoAYjjdDgFCFC7hw4KrVqQFZOqyW72PuOwX9MFFPdtxGp6-xAfoq1VAVAVck57JKJvRSDjzGQq8fQ9jZ811LUvxXW_ytUPwruZKw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1352288134</pqid></control><display><type>article</type><title>Structural damage evaluation of reinforced concrete beams exposed to high temperatures</title><source>SAGE Complete A-Z List</source><creator>Choi, E. G. ; Shin, Y.-S. ; Kim, H. S.</creator><creatorcontrib>Choi, E. G. ; Shin, Y.-S. ; Kim, H. S.</creatorcontrib><description>The objective of this study is to investigate the effect of temperature distribution, concrete strength, cover thickness, and heating time on the structural behavior of reinforced concrete beams. Toward this goal, reinforced concrete beams with different concrete compressive strength and cover thickness are fabricated and subjected to furnace heating for 60, 90, and 120min under a loaded state. In order to analyze structural behavior based on the thermal behavior of the beams, transient temperature distribution is measured during the furnace heating. After furnace heating, spalling is observed. From loading tests performed on the damaged reinforced concrete beams, residual strength, maximum loads, and beam deflections are measured and examined. The experimental results show that significant damage occurs in the reinforced concrete beams under high temperatures. In addition, it is found that thermal and structural behavior of damaged reinforced concrete beams is dependent on cover thickness and concrete strength and that most structural damage occurs in a relatively short period of heating time. Using these experimental findings, an equation is proposed that can be used to predict maximum load capacity and stiffness reduction ratio of the damaged reinforced concrete beams.</description><identifier>ISSN: 1042-3915</identifier><identifier>EISSN: 1532-172X</identifier><identifier>DOI: 10.1177/1042391512474666</identifier><language>eng</language><ispartof>Journal of fire protection engineering, 2013-05, Vol.23 (2), p.135-151</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c206t-fe9b1ba7d2593c239c59723648acfcc899c72919072f3ecc24ff2fe673b218f73</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Choi, E. G.</creatorcontrib><creatorcontrib>Shin, Y.-S.</creatorcontrib><creatorcontrib>Kim, H. S.</creatorcontrib><title>Structural damage evaluation of reinforced concrete beams exposed to high temperatures</title><title>Journal of fire protection engineering</title><description>The objective of this study is to investigate the effect of temperature distribution, concrete strength, cover thickness, and heating time on the structural behavior of reinforced concrete beams. Toward this goal, reinforced concrete beams with different concrete compressive strength and cover thickness are fabricated and subjected to furnace heating for 60, 90, and 120min under a loaded state. In order to analyze structural behavior based on the thermal behavior of the beams, transient temperature distribution is measured during the furnace heating. After furnace heating, spalling is observed. From loading tests performed on the damaged reinforced concrete beams, residual strength, maximum loads, and beam deflections are measured and examined. The experimental results show that significant damage occurs in the reinforced concrete beams under high temperatures. In addition, it is found that thermal and structural behavior of damaged reinforced concrete beams is dependent on cover thickness and concrete strength and that most structural damage occurs in a relatively short period of heating time. Using these experimental findings, an equation is proposed that can be used to predict maximum load capacity and stiffness reduction ratio of the damaged reinforced concrete beams.</description><issn>1042-3915</issn><issn>1532-172X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNpdkM1LxDAQxYMouK7ePebopZpM2qY5yuIXLHjwA28lnZ3sVtqmJqnof29lPXmaYX6Px7zH2LkUl1JqfSVFDsrIQkKu87IsD9hCFgoyqeHtcN5nnP3yY3YS47sQQuXKLNjrUwoTpinYjm9sb7fE6dN2k02tH7h3PFA7OB-QNhz9gIES8YZsHzl9jT7O5-T5rt3ueKJ-pGBnL4qn7MjZLtLZ31yyl9ub59V9tn68e1hdrzMEUabMkWlkY_UGCqNw_h8Lo0GVeWXRIVbGoAYjjdDgFCFC7hw4KrVqQFZOqyW72PuOwX9MFFPdtxGp6-xAfoq1VAVAVck57JKJvRSDjzGQq8fQ9jZ811LUvxXW_ytUPwruZKw</recordid><startdate>20130501</startdate><enddate>20130501</enddate><creator>Choi, E. G.</creator><creator>Shin, Y.-S.</creator><creator>Kim, H. S.</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7T2</scope><scope>7U2</scope><scope>C1K</scope></search><sort><creationdate>20130501</creationdate><title>Structural damage evaluation of reinforced concrete beams exposed to high temperatures</title><author>Choi, E. G. ; Shin, Y.-S. ; Kim, H. S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c206t-fe9b1ba7d2593c239c59723648acfcc899c72919072f3ecc24ff2fe673b218f73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Choi, E. G.</creatorcontrib><creatorcontrib>Shin, Y.-S.</creatorcontrib><creatorcontrib>Kim, H. S.</creatorcontrib><collection>CrossRef</collection><collection>Health and Safety Science Abstracts (Full archive)</collection><collection>Safety Science and Risk</collection><collection>Environmental Sciences and Pollution Management</collection><jtitle>Journal of fire protection engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Choi, E. G.</au><au>Shin, Y.-S.</au><au>Kim, H. S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Structural damage evaluation of reinforced concrete beams exposed to high temperatures</atitle><jtitle>Journal of fire protection engineering</jtitle><date>2013-05-01</date><risdate>2013</risdate><volume>23</volume><issue>2</issue><spage>135</spage><epage>151</epage><pages>135-151</pages><issn>1042-3915</issn><eissn>1532-172X</eissn><abstract>The objective of this study is to investigate the effect of temperature distribution, concrete strength, cover thickness, and heating time on the structural behavior of reinforced concrete beams. Toward this goal, reinforced concrete beams with different concrete compressive strength and cover thickness are fabricated and subjected to furnace heating for 60, 90, and 120min under a loaded state. In order to analyze structural behavior based on the thermal behavior of the beams, transient temperature distribution is measured during the furnace heating. After furnace heating, spalling is observed. From loading tests performed on the damaged reinforced concrete beams, residual strength, maximum loads, and beam deflections are measured and examined. The experimental results show that significant damage occurs in the reinforced concrete beams under high temperatures. In addition, it is found that thermal and structural behavior of damaged reinforced concrete beams is dependent on cover thickness and concrete strength and that most structural damage occurs in a relatively short period of heating time. Using these experimental findings, an equation is proposed that can be used to predict maximum load capacity and stiffness reduction ratio of the damaged reinforced concrete beams.</abstract><doi>10.1177/1042391512474666</doi><tpages>17</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1042-3915 |
ispartof | Journal of fire protection engineering, 2013-05, Vol.23 (2), p.135-151 |
issn | 1042-3915 1532-172X |
language | eng |
recordid | cdi_proquest_miscellaneous_1352288134 |
source | SAGE Complete A-Z List |
title | Structural damage evaluation of reinforced concrete beams exposed to high temperatures |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T23%3A33%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Structural%20damage%20evaluation%20of%20reinforced%20concrete%20beams%20exposed%20to%20high%20temperatures&rft.jtitle=Journal%20of%20fire%20protection%20engineering&rft.au=Choi,%20E.%20G.&rft.date=2013-05-01&rft.volume=23&rft.issue=2&rft.spage=135&rft.epage=151&rft.pages=135-151&rft.issn=1042-3915&rft.eissn=1532-172X&rft_id=info:doi/10.1177/1042391512474666&rft_dat=%3Cproquest_cross%3E1352288134%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1352288134&rft_id=info:pmid/&rfr_iscdi=true |