Feasibility and validity of self-reported walking capacity in patients with intermittent claudication

Objective The primary aim of this study was to assess if self-reported measures of walking limitation correlate better with a community-based assessment of maximum walking distance (MWD) than they do with laboratory-based tests in patients with intermittent claudication. A secondary aim was to exami...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Vascular Surgery 2013-05, Vol.57 (5), p.1227-1234
Hauptverfasser: Tew, Garry, PhD, Copeland, Robert, PhD, Le Faucheur, Alexis, PhD, Gernigon, Marie, MSc, Nawaz, Shah, MD, Abraham, Pierre, MD, PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective The primary aim of this study was to assess if self-reported measures of walking limitation correlate better with a community-based assessment of maximum walking distance (MWD) than they do with laboratory-based tests in patients with intermittent claudication. A secondary aim was to examine the effect of prior objective testing on these correlations. Methods Thirty-one patients completed three self-report tools (self-reported MWD; Walking Impairment Questionnaire [WIQ]; Estimation of Ambulatory Capacity by History-Questionnaire [EACH-Q]) immediately before and approximately 1 week after a series of objective tests (incremental treadmill walking test, 6-minute walk test, 1-hour global positioning system [GPS] recording of a community walk). We analyzed the feasibility of the self-report tools in terms of number of errors and their correlation (r) with objective measures. Results The correlations of self-report tests to GPS-MWD (range, .579-.808) were consistently higher than with the treadmill test (range, .310-.584) and 6-minute walk test (range, .414-.613). The WIQ had the highest proportion of errors, both at first and second completion (58% and 42%, respectively), compared with self-reported MWD (23% and 13%, respectively) and the EACH-Q (6.5% and 13%, respectively). Correlations were improved with the second set of self-report tests (range, .310-.595 to .414-.808). Conclusions The fact that all self-report tools correlated better with a community-based measure of MWD using GPS than with laboratory results confirms that they measure what they aim to: community-based MWD. In addition, prescription of a community walk might help patients to better estimate their walking limitation.
ISSN:0741-5214
1097-6809
DOI:10.1016/j.jvs.2012.02.073