Tolerability of 24-Hour Intraocular Pressure Monitoring of a Pressure-sensitive Contact Lens

PURPOSE:To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. PATIENTS AND METHODS:Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this pro...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of glaucoma 2013-04, Vol.22 (4), p.311-316
Hauptverfasser: Lorenz, Katrin, Korb, Christina, Herzog, Nicola, Vetter, Jan M, Elflein, Heike, Keilani, Munir M, Pfeiffer, Norbert
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 316
container_issue 4
container_start_page 311
container_title Journal of glaucoma
container_volume 22
creator Lorenz, Katrin
Korb, Christina
Herzog, Nicola
Vetter, Jan M
Elflein, Heike
Keilani, Munir M
Pfeiffer, Norbert
description PURPOSE:To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. PATIENTS AND METHODS:Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Safety parameters included best corrected visual acuity, pachymetry, epithelial defects, conjunctival erythema, and corneal topography. RESULTS:Mean age was 61.7 years in group 1 and 65.0 years in group 2. Nineteen healthy subjects and 19 glaucoma patients (95%) completed the 24-hour wearing period. Early discontinuation resulted from pain (n=1) or inappropriate fitting of the sensor due to steep corneal radii (n=1). Mean tolerability was 21.8 in group 1 (range, 7 to 67) and 26.8 in group 2 (range, 0 to 71). Corneal epithelial staining (Modified Oxford scale, grade 0 to 4) changed from 0.4 (group 1) and 1.0 (group 2) at baseline to 1.8 (group 1) and 2.8 (group 2) after monitoring. No statistically significant differences could be detected between both groups. CONCLUSIONS:This new pressure-sensitive contact lens is tolerable and safe over a 24-hour wearing period in healthy subjects and glaucoma patients. Both normals and glaucoma patients had a similar safety and tolerability profile.
doi_str_mv 10.1097/IJG.0b013e318241b874
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1322732130</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1322732130</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4224-5004c26478a9968e4c0961bf52857f4e5f5e4e50a3eec19e673dcf483fd85b593</originalsourceid><addsrcrecordid>eNp9kE1PwzAMhiMEYmPwDxDqkUtHPtv0iCY-hobgMCQOSFWauayQNSNJmfbvybSxAwcutmU_fm29CJ0TPCS4yK_GD3dDXGHCgBFJOalkzg9QnwiWpVyS18NYY5GnWNKih068_8CYYkrJMepRJiiXIu-jt6k14FTVmCasE1snlKf3tnPJuA1OWd0Z5ZJnB953DpJH2zbBuqZ936BqP0g9tL4JzTckI9sGpUMyiZ1TdFQr4-Fslwfo5fZmOrpPJ09349H1JNWcxnsCY65pxnOpiiKTwDUuMlLVgsYXaw6iFhAjVgxAkwKynM10zSWrZ1JUomADdLnVXTr71YEP5aLxGoxRLdjOl4RRmjNKGI4o36LaWe8d1OXSNQvl1iXB5cbXMvpa_vU1rl3sLnTVAmb7pV8jIyC3wMqaAM5_mm4FrpyDMmH-v_YPIJqF9w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1322732130</pqid></control><display><type>article</type><title>Tolerability of 24-Hour Intraocular Pressure Monitoring of a Pressure-sensitive Contact Lens</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>Lorenz, Katrin ; Korb, Christina ; Herzog, Nicola ; Vetter, Jan M ; Elflein, Heike ; Keilani, Munir M ; Pfeiffer, Norbert</creator><creatorcontrib>Lorenz, Katrin ; Korb, Christina ; Herzog, Nicola ; Vetter, Jan M ; Elflein, Heike ; Keilani, Munir M ; Pfeiffer, Norbert</creatorcontrib><description>PURPOSE:To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. PATIENTS AND METHODS:Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Safety parameters included best corrected visual acuity, pachymetry, epithelial defects, conjunctival erythema, and corneal topography. RESULTS:Mean age was 61.7 years in group 1 and 65.0 years in group 2. Nineteen healthy subjects and 19 glaucoma patients (95%) completed the 24-hour wearing period. Early discontinuation resulted from pain (n=1) or inappropriate fitting of the sensor due to steep corneal radii (n=1). Mean tolerability was 21.8 in group 1 (range, 7 to 67) and 26.8 in group 2 (range, 0 to 71). Corneal epithelial staining (Modified Oxford scale, grade 0 to 4) changed from 0.4 (group 1) and 1.0 (group 2) at baseline to 1.8 (group 1) and 2.8 (group 2) after monitoring. No statistically significant differences could be detected between both groups. CONCLUSIONS:This new pressure-sensitive contact lens is tolerable and safe over a 24-hour wearing period in healthy subjects and glaucoma patients. Both normals and glaucoma patients had a similar safety and tolerability profile.</description><identifier>ISSN: 1057-0829</identifier><identifier>EISSN: 1536-481X</identifier><identifier>DOI: 10.1097/IJG.0b013e318241b874</identifier><identifier>PMID: 23524857</identifier><language>eng</language><publisher>United States: Lippincott Williams &amp; Wilkins, Inc</publisher><subject>Adult ; Aged ; Circadian Rhythm - physiology ; Contact Lenses, Hydrophilic ; Corneal Pachymetry ; Corneal Topography ; Equipment Safety ; Female ; Glaucoma - diagnosis ; Glaucoma - physiopathology ; Humans ; Intraocular Pressure - physiology ; Male ; Middle Aged ; Monitoring, Ambulatory - adverse effects ; Monitoring, Ambulatory - instrumentation ; Patient Satisfaction ; Prospective Studies ; Telemetry - instrumentation ; Tonometry, Ocular - adverse effects ; Tonometry, Ocular - instrumentation ; Visual Acuity - physiology</subject><ispartof>Journal of glaucoma, 2013-04, Vol.22 (4), p.311-316</ispartof><rights>2013 Lippincott Williams &amp; Wilkins, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4224-5004c26478a9968e4c0961bf52857f4e5f5e4e50a3eec19e673dcf483fd85b593</citedby><cites>FETCH-LOGICAL-c4224-5004c26478a9968e4c0961bf52857f4e5f5e4e50a3eec19e673dcf483fd85b593</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23524857$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lorenz, Katrin</creatorcontrib><creatorcontrib>Korb, Christina</creatorcontrib><creatorcontrib>Herzog, Nicola</creatorcontrib><creatorcontrib>Vetter, Jan M</creatorcontrib><creatorcontrib>Elflein, Heike</creatorcontrib><creatorcontrib>Keilani, Munir M</creatorcontrib><creatorcontrib>Pfeiffer, Norbert</creatorcontrib><title>Tolerability of 24-Hour Intraocular Pressure Monitoring of a Pressure-sensitive Contact Lens</title><title>Journal of glaucoma</title><addtitle>J Glaucoma</addtitle><description>PURPOSE:To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. PATIENTS AND METHODS:Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Safety parameters included best corrected visual acuity, pachymetry, epithelial defects, conjunctival erythema, and corneal topography. RESULTS:Mean age was 61.7 years in group 1 and 65.0 years in group 2. Nineteen healthy subjects and 19 glaucoma patients (95%) completed the 24-hour wearing period. Early discontinuation resulted from pain (n=1) or inappropriate fitting of the sensor due to steep corneal radii (n=1). Mean tolerability was 21.8 in group 1 (range, 7 to 67) and 26.8 in group 2 (range, 0 to 71). Corneal epithelial staining (Modified Oxford scale, grade 0 to 4) changed from 0.4 (group 1) and 1.0 (group 2) at baseline to 1.8 (group 1) and 2.8 (group 2) after monitoring. No statistically significant differences could be detected between both groups. CONCLUSIONS:This new pressure-sensitive contact lens is tolerable and safe over a 24-hour wearing period in healthy subjects and glaucoma patients. Both normals and glaucoma patients had a similar safety and tolerability profile.</description><subject>Adult</subject><subject>Aged</subject><subject>Circadian Rhythm - physiology</subject><subject>Contact Lenses, Hydrophilic</subject><subject>Corneal Pachymetry</subject><subject>Corneal Topography</subject><subject>Equipment Safety</subject><subject>Female</subject><subject>Glaucoma - diagnosis</subject><subject>Glaucoma - physiopathology</subject><subject>Humans</subject><subject>Intraocular Pressure - physiology</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Monitoring, Ambulatory - adverse effects</subject><subject>Monitoring, Ambulatory - instrumentation</subject><subject>Patient Satisfaction</subject><subject>Prospective Studies</subject><subject>Telemetry - instrumentation</subject><subject>Tonometry, Ocular - adverse effects</subject><subject>Tonometry, Ocular - instrumentation</subject><subject>Visual Acuity - physiology</subject><issn>1057-0829</issn><issn>1536-481X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE1PwzAMhiMEYmPwDxDqkUtHPtv0iCY-hobgMCQOSFWauayQNSNJmfbvybSxAwcutmU_fm29CJ0TPCS4yK_GD3dDXGHCgBFJOalkzg9QnwiWpVyS18NYY5GnWNKih068_8CYYkrJMepRJiiXIu-jt6k14FTVmCasE1snlKf3tnPJuA1OWd0Z5ZJnB953DpJH2zbBuqZ936BqP0g9tL4JzTckI9sGpUMyiZ1TdFQr4-Fslwfo5fZmOrpPJ09349H1JNWcxnsCY65pxnOpiiKTwDUuMlLVgsYXaw6iFhAjVgxAkwKynM10zSWrZ1JUomADdLnVXTr71YEP5aLxGoxRLdjOl4RRmjNKGI4o36LaWe8d1OXSNQvl1iXB5cbXMvpa_vU1rl3sLnTVAmb7pV8jIyC3wMqaAM5_mm4FrpyDMmH-v_YPIJqF9w</recordid><startdate>201304</startdate><enddate>201304</enddate><creator>Lorenz, Katrin</creator><creator>Korb, Christina</creator><creator>Herzog, Nicola</creator><creator>Vetter, Jan M</creator><creator>Elflein, Heike</creator><creator>Keilani, Munir M</creator><creator>Pfeiffer, Norbert</creator><general>Lippincott Williams &amp; Wilkins, Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201304</creationdate><title>Tolerability of 24-Hour Intraocular Pressure Monitoring of a Pressure-sensitive Contact Lens</title><author>Lorenz, Katrin ; Korb, Christina ; Herzog, Nicola ; Vetter, Jan M ; Elflein, Heike ; Keilani, Munir M ; Pfeiffer, Norbert</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4224-5004c26478a9968e4c0961bf52857f4e5f5e4e50a3eec19e673dcf483fd85b593</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Circadian Rhythm - physiology</topic><topic>Contact Lenses, Hydrophilic</topic><topic>Corneal Pachymetry</topic><topic>Corneal Topography</topic><topic>Equipment Safety</topic><topic>Female</topic><topic>Glaucoma - diagnosis</topic><topic>Glaucoma - physiopathology</topic><topic>Humans</topic><topic>Intraocular Pressure - physiology</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Monitoring, Ambulatory - adverse effects</topic><topic>Monitoring, Ambulatory - instrumentation</topic><topic>Patient Satisfaction</topic><topic>Prospective Studies</topic><topic>Telemetry - instrumentation</topic><topic>Tonometry, Ocular - adverse effects</topic><topic>Tonometry, Ocular - instrumentation</topic><topic>Visual Acuity - physiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lorenz, Katrin</creatorcontrib><creatorcontrib>Korb, Christina</creatorcontrib><creatorcontrib>Herzog, Nicola</creatorcontrib><creatorcontrib>Vetter, Jan M</creatorcontrib><creatorcontrib>Elflein, Heike</creatorcontrib><creatorcontrib>Keilani, Munir M</creatorcontrib><creatorcontrib>Pfeiffer, Norbert</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of glaucoma</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lorenz, Katrin</au><au>Korb, Christina</au><au>Herzog, Nicola</au><au>Vetter, Jan M</au><au>Elflein, Heike</au><au>Keilani, Munir M</au><au>Pfeiffer, Norbert</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Tolerability of 24-Hour Intraocular Pressure Monitoring of a Pressure-sensitive Contact Lens</atitle><jtitle>Journal of glaucoma</jtitle><addtitle>J Glaucoma</addtitle><date>2013-04</date><risdate>2013</risdate><volume>22</volume><issue>4</issue><spage>311</spage><epage>316</epage><pages>311-316</pages><issn>1057-0829</issn><eissn>1536-481X</eissn><abstract>PURPOSE:To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. PATIENTS AND METHODS:Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Safety parameters included best corrected visual acuity, pachymetry, epithelial defects, conjunctival erythema, and corneal topography. RESULTS:Mean age was 61.7 years in group 1 and 65.0 years in group 2. Nineteen healthy subjects and 19 glaucoma patients (95%) completed the 24-hour wearing period. Early discontinuation resulted from pain (n=1) or inappropriate fitting of the sensor due to steep corneal radii (n=1). Mean tolerability was 21.8 in group 1 (range, 7 to 67) and 26.8 in group 2 (range, 0 to 71). Corneal epithelial staining (Modified Oxford scale, grade 0 to 4) changed from 0.4 (group 1) and 1.0 (group 2) at baseline to 1.8 (group 1) and 2.8 (group 2) after monitoring. No statistically significant differences could be detected between both groups. CONCLUSIONS:This new pressure-sensitive contact lens is tolerable and safe over a 24-hour wearing period in healthy subjects and glaucoma patients. Both normals and glaucoma patients had a similar safety and tolerability profile.</abstract><cop>United States</cop><pub>Lippincott Williams &amp; Wilkins, Inc</pub><pmid>23524857</pmid><doi>10.1097/IJG.0b013e318241b874</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1057-0829
ispartof Journal of glaucoma, 2013-04, Vol.22 (4), p.311-316
issn 1057-0829
1536-481X
language eng
recordid cdi_proquest_miscellaneous_1322732130
source MEDLINE; Journals@Ovid Complete
subjects Adult
Aged
Circadian Rhythm - physiology
Contact Lenses, Hydrophilic
Corneal Pachymetry
Corneal Topography
Equipment Safety
Female
Glaucoma - diagnosis
Glaucoma - physiopathology
Humans
Intraocular Pressure - physiology
Male
Middle Aged
Monitoring, Ambulatory - adverse effects
Monitoring, Ambulatory - instrumentation
Patient Satisfaction
Prospective Studies
Telemetry - instrumentation
Tonometry, Ocular - adverse effects
Tonometry, Ocular - instrumentation
Visual Acuity - physiology
title Tolerability of 24-Hour Intraocular Pressure Monitoring of a Pressure-sensitive Contact Lens
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T20%3A17%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Tolerability%20of%2024-Hour%20Intraocular%20Pressure%20Monitoring%20of%20a%20Pressure-sensitive%20Contact%20Lens&rft.jtitle=Journal%20of%20glaucoma&rft.au=Lorenz,%20Katrin&rft.date=2013-04&rft.volume=22&rft.issue=4&rft.spage=311&rft.epage=316&rft.pages=311-316&rft.issn=1057-0829&rft.eissn=1536-481X&rft_id=info:doi/10.1097/IJG.0b013e318241b874&rft_dat=%3Cproquest_cross%3E1322732130%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1322732130&rft_id=info:pmid/23524857&rfr_iscdi=true