NON-INVASIVE EVALUATION OF CARDIAC FUNCTION WITH PULSED DOPPLER FLOWMETER

The peak (dPower/dt), the maximum value of dPower/dt calculated by differentiation of ventricular power with respect to time, is verified from the physiological studies to be quite useful index indicating the ventricular contractility independent of the pre- and afterloads. However, the index has th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Tairyoku kagaku. Japanese journal of physical fitness and sports medicine 2012-01, Vol.34(1985 (Supplement), p.99-112
Hauptverfasser: Takayama, Kazuhisa, MAIE, KENICHI, Miyashita, Yuzo, Takahashi, Ikumi, FUJISAKI, HISAMITI, HARA, MASATADA, Nakatsuka, Takayuki, Yoshimura, Shozo, Furuhata, Hiroshi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 112
container_issue Supplement
container_start_page 99
container_title Tairyoku kagaku. Japanese journal of physical fitness and sports medicine
container_volume 34(1985
creator Takayama, Kazuhisa
MAIE, KENICHI
Miyashita, Yuzo
Takahashi, Ikumi
FUJISAKI, HISAMITI
HARA, MASATADA
Nakatsuka, Takayuki
Yoshimura, Shozo
Furuhata, Hiroshi
description The peak (dPower/dt), the maximum value of dPower/dt calculated by differentiation of ventricular power with respect to time, is verified from the physiological studies to be quite useful index indicating the ventricular contractility independent of the pre- and afterloads. However, the index has the disadvantage in the clinical application that it can not be measured by a non-invasive method. In the present study, peak (dPower/dt) could successfully be determined in a non-invasive manner as the product of aortic flow as measured with an ultrasonic pulsed Doppler flowmeter and brachial blood pressure as measured with cuff in the new apparatus. Involved in this study were 21 children, 52 adults with normal cardiac performance and 11 adult patients with coronary artery disease. The measurement of the index was successfully carried out in 28 of 61 adults and especially 16 of 21 children. The results of the study are summarized as follows:1. Power waveform is similar to blood flow waveform and is little influenced by blood pressure waveform.2, Peak (dPower/dt) can be determined as product of peak rate of change of aortic flow (peak (dF/dt)) and mean brachial blood pressure without resorting to measurement of blood pressure waveform.3. Peak (dPower/dt) was found significantly lower in cases having an ejection fraction less than 50% (93.5 J/sec2) than in those showing an ejection fraction of above 50% (145.3 J/sec2) (p
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_1285103553</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1285103553</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_12851035533</originalsourceid><addsrcrecordid>eNqVyt0KgjAYgOERBdnPPeywE-Fby7_DoRMHaxOd2plIGBSW1er-g-gGOnrh4Z0gh4QhcXeBR6bIAaCRG4F_mKOFtRcAnwQADhJKK1eompWi5pjXTFbMCK2wTnHMikSwGKeVir_WCJPhvJIlT3Ci81zyAqdSN3tueLFCs1M32H796xJtUm7izL0_x8e7t6_2erbHfhi6Wz--bUu2oUeAeh6lf6wfZ886tQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1285103553</pqid></control><display><type>article</type><title>NON-INVASIVE EVALUATION OF CARDIAC FUNCTION WITH PULSED DOPPLER FLOWMETER</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>J-STAGE (Japan Science &amp; Technology Information Aggregator, Electronic) Freely Available Titles - Japanese</source><creator>Takayama, Kazuhisa ; MAIE, KENICHI ; Miyashita, Yuzo ; Takahashi, Ikumi ; FUJISAKI, HISAMITI ; HARA, MASATADA ; Nakatsuka, Takayuki ; Yoshimura, Shozo ; Furuhata, Hiroshi</creator><creatorcontrib>Takayama, Kazuhisa ; MAIE, KENICHI ; Miyashita, Yuzo ; Takahashi, Ikumi ; FUJISAKI, HISAMITI ; HARA, MASATADA ; Nakatsuka, Takayuki ; Yoshimura, Shozo ; Furuhata, Hiroshi</creatorcontrib><description>The peak (dPower/dt), the maximum value of dPower/dt calculated by differentiation of ventricular power with respect to time, is verified from the physiological studies to be quite useful index indicating the ventricular contractility independent of the pre- and afterloads. However, the index has the disadvantage in the clinical application that it can not be measured by a non-invasive method. In the present study, peak (dPower/dt) could successfully be determined in a non-invasive manner as the product of aortic flow as measured with an ultrasonic pulsed Doppler flowmeter and brachial blood pressure as measured with cuff in the new apparatus. Involved in this study were 21 children, 52 adults with normal cardiac performance and 11 adult patients with coronary artery disease. The measurement of the index was successfully carried out in 28 of 61 adults and especially 16 of 21 children. The results of the study are summarized as follows:1. Power waveform is similar to blood flow waveform and is little influenced by blood pressure waveform.2, Peak (dPower/dt) can be determined as product of peak rate of change of aortic flow (peak (dF/dt)) and mean brachial blood pressure without resorting to measurement of blood pressure waveform.3. Peak (dPower/dt) was found significantly lower in cases having an ejection fraction less than 50% (93.5 J/sec2) than in those showing an ejection fraction of above 50% (145.3 J/sec2) (p&lt;0.001) .4. Peak (dPower/dt) normalized with body surface area was not significantly different from 8 years old children (80.2 J/sec2/m2) and 21-34 years old adults (88.0 J/sec2/m2) . According to this index, the cardiac contractility of 8 yearus old children seemed to reach the adult level.From these findings it is concluded that the non-invasive method of determining a cardiologic parameter, peak (dPower/dt), as an index of cardiac contractility provides a means of salient clinical value.</description><identifier>ISSN: 0039-906X</identifier><identifier>EISSN: 1881-4751</identifier><language>eng</language><subject>Adults ; Blood flow ; Blood pressure ; Cardiac function ; Children ; Circulatory system ; Measurement ; Power</subject><ispartof>Tairyoku kagaku. Japanese journal of physical fitness and sports medicine, 2012-01, Vol.34(1985 (Supplement), p.99-112</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids></links><search><creatorcontrib>Takayama, Kazuhisa</creatorcontrib><creatorcontrib>MAIE, KENICHI</creatorcontrib><creatorcontrib>Miyashita, Yuzo</creatorcontrib><creatorcontrib>Takahashi, Ikumi</creatorcontrib><creatorcontrib>FUJISAKI, HISAMITI</creatorcontrib><creatorcontrib>HARA, MASATADA</creatorcontrib><creatorcontrib>Nakatsuka, Takayuki</creatorcontrib><creatorcontrib>Yoshimura, Shozo</creatorcontrib><creatorcontrib>Furuhata, Hiroshi</creatorcontrib><title>NON-INVASIVE EVALUATION OF CARDIAC FUNCTION WITH PULSED DOPPLER FLOWMETER</title><title>Tairyoku kagaku. Japanese journal of physical fitness and sports medicine</title><description>The peak (dPower/dt), the maximum value of dPower/dt calculated by differentiation of ventricular power with respect to time, is verified from the physiological studies to be quite useful index indicating the ventricular contractility independent of the pre- and afterloads. However, the index has the disadvantage in the clinical application that it can not be measured by a non-invasive method. In the present study, peak (dPower/dt) could successfully be determined in a non-invasive manner as the product of aortic flow as measured with an ultrasonic pulsed Doppler flowmeter and brachial blood pressure as measured with cuff in the new apparatus. Involved in this study were 21 children, 52 adults with normal cardiac performance and 11 adult patients with coronary artery disease. The measurement of the index was successfully carried out in 28 of 61 adults and especially 16 of 21 children. The results of the study are summarized as follows:1. Power waveform is similar to blood flow waveform and is little influenced by blood pressure waveform.2, Peak (dPower/dt) can be determined as product of peak rate of change of aortic flow (peak (dF/dt)) and mean brachial blood pressure without resorting to measurement of blood pressure waveform.3. Peak (dPower/dt) was found significantly lower in cases having an ejection fraction less than 50% (93.5 J/sec2) than in those showing an ejection fraction of above 50% (145.3 J/sec2) (p&lt;0.001) .4. Peak (dPower/dt) normalized with body surface area was not significantly different from 8 years old children (80.2 J/sec2/m2) and 21-34 years old adults (88.0 J/sec2/m2) . According to this index, the cardiac contractility of 8 yearus old children seemed to reach the adult level.From these findings it is concluded that the non-invasive method of determining a cardiologic parameter, peak (dPower/dt), as an index of cardiac contractility provides a means of salient clinical value.</description><subject>Adults</subject><subject>Blood flow</subject><subject>Blood pressure</subject><subject>Cardiac function</subject><subject>Children</subject><subject>Circulatory system</subject><subject>Measurement</subject><subject>Power</subject><issn>0039-906X</issn><issn>1881-4751</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNqVyt0KgjAYgOERBdnPPeywE-Fby7_DoRMHaxOd2plIGBSW1er-g-gGOnrh4Z0gh4QhcXeBR6bIAaCRG4F_mKOFtRcAnwQADhJKK1eompWi5pjXTFbMCK2wTnHMikSwGKeVir_WCJPhvJIlT3Ci81zyAqdSN3tueLFCs1M32H796xJtUm7izL0_x8e7t6_2erbHfhi6Wz--bUu2oUeAeh6lf6wfZ886tQ</recordid><startdate>20120101</startdate><enddate>20120101</enddate><creator>Takayama, Kazuhisa</creator><creator>MAIE, KENICHI</creator><creator>Miyashita, Yuzo</creator><creator>Takahashi, Ikumi</creator><creator>FUJISAKI, HISAMITI</creator><creator>HARA, MASATADA</creator><creator>Nakatsuka, Takayuki</creator><creator>Yoshimura, Shozo</creator><creator>Furuhata, Hiroshi</creator><scope>7TS</scope></search><sort><creationdate>20120101</creationdate><title>NON-INVASIVE EVALUATION OF CARDIAC FUNCTION WITH PULSED DOPPLER FLOWMETER</title><author>Takayama, Kazuhisa ; MAIE, KENICHI ; Miyashita, Yuzo ; Takahashi, Ikumi ; FUJISAKI, HISAMITI ; HARA, MASATADA ; Nakatsuka, Takayuki ; Yoshimura, Shozo ; Furuhata, Hiroshi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_12851035533</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Adults</topic><topic>Blood flow</topic><topic>Blood pressure</topic><topic>Cardiac function</topic><topic>Children</topic><topic>Circulatory system</topic><topic>Measurement</topic><topic>Power</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Takayama, Kazuhisa</creatorcontrib><creatorcontrib>MAIE, KENICHI</creatorcontrib><creatorcontrib>Miyashita, Yuzo</creatorcontrib><creatorcontrib>Takahashi, Ikumi</creatorcontrib><creatorcontrib>FUJISAKI, HISAMITI</creatorcontrib><creatorcontrib>HARA, MASATADA</creatorcontrib><creatorcontrib>Nakatsuka, Takayuki</creatorcontrib><creatorcontrib>Yoshimura, Shozo</creatorcontrib><creatorcontrib>Furuhata, Hiroshi</creatorcontrib><collection>Physical Education Index</collection><jtitle>Tairyoku kagaku. Japanese journal of physical fitness and sports medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Takayama, Kazuhisa</au><au>MAIE, KENICHI</au><au>Miyashita, Yuzo</au><au>Takahashi, Ikumi</au><au>FUJISAKI, HISAMITI</au><au>HARA, MASATADA</au><au>Nakatsuka, Takayuki</au><au>Yoshimura, Shozo</au><au>Furuhata, Hiroshi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>NON-INVASIVE EVALUATION OF CARDIAC FUNCTION WITH PULSED DOPPLER FLOWMETER</atitle><jtitle>Tairyoku kagaku. Japanese journal of physical fitness and sports medicine</jtitle><date>2012-01-01</date><risdate>2012</risdate><volume>34(1985</volume><issue>Supplement</issue><spage>99</spage><epage>112</epage><pages>99-112</pages><issn>0039-906X</issn><eissn>1881-4751</eissn><abstract>The peak (dPower/dt), the maximum value of dPower/dt calculated by differentiation of ventricular power with respect to time, is verified from the physiological studies to be quite useful index indicating the ventricular contractility independent of the pre- and afterloads. However, the index has the disadvantage in the clinical application that it can not be measured by a non-invasive method. In the present study, peak (dPower/dt) could successfully be determined in a non-invasive manner as the product of aortic flow as measured with an ultrasonic pulsed Doppler flowmeter and brachial blood pressure as measured with cuff in the new apparatus. Involved in this study were 21 children, 52 adults with normal cardiac performance and 11 adult patients with coronary artery disease. The measurement of the index was successfully carried out in 28 of 61 adults and especially 16 of 21 children. The results of the study are summarized as follows:1. Power waveform is similar to blood flow waveform and is little influenced by blood pressure waveform.2, Peak (dPower/dt) can be determined as product of peak rate of change of aortic flow (peak (dF/dt)) and mean brachial blood pressure without resorting to measurement of blood pressure waveform.3. Peak (dPower/dt) was found significantly lower in cases having an ejection fraction less than 50% (93.5 J/sec2) than in those showing an ejection fraction of above 50% (145.3 J/sec2) (p&lt;0.001) .4. Peak (dPower/dt) normalized with body surface area was not significantly different from 8 years old children (80.2 J/sec2/m2) and 21-34 years old adults (88.0 J/sec2/m2) . According to this index, the cardiac contractility of 8 yearus old children seemed to reach the adult level.From these findings it is concluded that the non-invasive method of determining a cardiologic parameter, peak (dPower/dt), as an index of cardiac contractility provides a means of salient clinical value.</abstract></addata></record>
fulltext fulltext
identifier ISSN: 0039-906X
ispartof Tairyoku kagaku. Japanese journal of physical fitness and sports medicine, 2012-01, Vol.34(1985 (Supplement), p.99-112
issn 0039-906X
1881-4751
language eng
recordid cdi_proquest_miscellaneous_1285103553
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; J-STAGE (Japan Science & Technology Information Aggregator, Electronic) Freely Available Titles - Japanese
subjects Adults
Blood flow
Blood pressure
Cardiac function
Children
Circulatory system
Measurement
Power
title NON-INVASIVE EVALUATION OF CARDIAC FUNCTION WITH PULSED DOPPLER FLOWMETER
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T15%3A06%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=NON-INVASIVE%20EVALUATION%20OF%20CARDIAC%20FUNCTION%20WITH%20PULSED%20DOPPLER%20FLOWMETER&rft.jtitle=Tairyoku%20kagaku.%20Japanese%20journal%20of%20physical%20fitness%20and%20sports%20medicine&rft.au=Takayama,%20Kazuhisa&rft.date=2012-01-01&rft.volume=34(1985&rft.issue=Supplement&rft.spage=99&rft.epage=112&rft.pages=99-112&rft.issn=0039-906X&rft.eissn=1881-4751&rft_id=info:doi/&rft_dat=%3Cproquest%3E1285103553%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1285103553&rft_id=info:pmid/&rfr_iscdi=true