Integrated optofluidic system for monitoring particle mass concentrations based on planar emitter-receiver units
We demonstrate an integrated optofluidic system for monitoring the particle mass concentration and the Sauter mean diameter of polydisperse flowing suspensions of water and standardized test dust. For optimum integration, a planar emitter-receiver unit is developed and fabricated on Si technology. A...
Gespeichert in:
Veröffentlicht in: | Applied optics (2004) 2012-11, Vol.51 (32), p.7800-7809 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 7809 |
---|---|
container_issue | 32 |
container_start_page | 7800 |
container_title | Applied optics (2004) |
container_volume | 51 |
creator | Hofmann, Meike Müller, Ralf Stoebenau, Sebastian Stauden, Thomas Brodersen, Olaf Sinzinger, Stefan |
description | We demonstrate an integrated optofluidic system for monitoring the particle mass concentration and the Sauter mean diameter of polydisperse flowing suspensions of water and standardized test dust. For optimum integration, a planar emitter-receiver unit is developed and fabricated on Si technology. A vertical cavity surface emitting laser at 850 nm serves as light source, and monolithically integrated segmented photodiodes detect both the attenuation of the primary light beam and the scattered light. The optical system is integrated into a planar transparent polymethylmethacrylate substrate by micromilling of an optical freeform surface and electron beam evaporation of reflective layers following the concept of planar integrated free-space optical systems. We are able to detect 1 mg/L of the standards ISO 12103-A2 (fine test dust), -A3 (medium test dust), and -A4 (coarse test dust) and to determine the Sauter mean diameter of the particle size distribution. |
doi_str_mv | 10.1364/AO.51.007800 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1283709067</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1283709067</sourcerecordid><originalsourceid>FETCH-LOGICAL-c281t-b38d4a8e01ef4f23564c7c8ecc862175488b72ed6b75fb58c96c2804a93b6d933</originalsourceid><addsrcrecordid>eNqFkT1PwzAQhi0EglLYmJFHBlL8GTtjVfFRqVIXkNgix7lURkkcbAep_55UBVamu-F5H53uReiGkgXluXhYbheSLghRmpATNGNUyozTXJ6i2bQWGWX6_QJdxvhBCJeiUOfognEqmC74DA3rPsEumAQ19kPyTTu62lkc9zFBhxsfcOd7l3xw_Q4PJiRnW8CdiRFb31vo0xR2vo-4MvEg6fHQmt4EDJ1LCUIWwIL7goDHyROv0Flj2gjXP3OO3p4eX1cv2Wb7vF4tN5llmqas4roWRgOh0IiGcZkLq6wGa3XOqJJC60oxqPNKyaaS2hb5FCTCFLzK64LzObo7eofgP0eIqexctNBOt4EfYzm9hStSkFz9j1JJFSFakwm9P6I2-BgDNOUQXGfCvqSkPNRRLrelpOWxjgm__TGPVQf1H_z7f_4NBPCHGg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1151700880</pqid></control><display><type>article</type><title>Integrated optofluidic system for monitoring particle mass concentrations based on planar emitter-receiver units</title><source>Alma/SFX Local Collection</source><source>Optica Publishing Group Journals</source><creator>Hofmann, Meike ; Müller, Ralf ; Stoebenau, Sebastian ; Stauden, Thomas ; Brodersen, Olaf ; Sinzinger, Stefan</creator><creatorcontrib>Hofmann, Meike ; Müller, Ralf ; Stoebenau, Sebastian ; Stauden, Thomas ; Brodersen, Olaf ; Sinzinger, Stefan</creatorcontrib><description>We demonstrate an integrated optofluidic system for monitoring the particle mass concentration and the Sauter mean diameter of polydisperse flowing suspensions of water and standardized test dust. For optimum integration, a planar emitter-receiver unit is developed and fabricated on Si technology. A vertical cavity surface emitting laser at 850 nm serves as light source, and monolithically integrated segmented photodiodes detect both the attenuation of the primary light beam and the scattered light. The optical system is integrated into a planar transparent polymethylmethacrylate substrate by micromilling of an optical freeform surface and electron beam evaporation of reflective layers following the concept of planar integrated free-space optical systems. We are able to detect 1 mg/L of the standards ISO 12103-A2 (fine test dust), -A3 (medium test dust), and -A4 (coarse test dust) and to determine the Sauter mean diameter of the particle size distribution.</description><identifier>ISSN: 1559-128X</identifier><identifier>EISSN: 2155-3165</identifier><identifier>EISSN: 1539-4522</identifier><identifier>DOI: 10.1364/AO.51.007800</identifier><identifier>PMID: 23142893</identifier><language>eng</language><publisher>United States</publisher><subject>Attenuation ; Dust ; Emittance ; Monitoring ; Optimization ; Particle mass ; Sauter mean diameter</subject><ispartof>Applied optics (2004), 2012-11, Vol.51 (32), p.7800-7809</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c281t-b38d4a8e01ef4f23564c7c8ecc862175488b72ed6b75fb58c96c2804a93b6d933</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,3245,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23142893$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hofmann, Meike</creatorcontrib><creatorcontrib>Müller, Ralf</creatorcontrib><creatorcontrib>Stoebenau, Sebastian</creatorcontrib><creatorcontrib>Stauden, Thomas</creatorcontrib><creatorcontrib>Brodersen, Olaf</creatorcontrib><creatorcontrib>Sinzinger, Stefan</creatorcontrib><title>Integrated optofluidic system for monitoring particle mass concentrations based on planar emitter-receiver units</title><title>Applied optics (2004)</title><addtitle>Appl Opt</addtitle><description>We demonstrate an integrated optofluidic system for monitoring the particle mass concentration and the Sauter mean diameter of polydisperse flowing suspensions of water and standardized test dust. For optimum integration, a planar emitter-receiver unit is developed and fabricated on Si technology. A vertical cavity surface emitting laser at 850 nm serves as light source, and monolithically integrated segmented photodiodes detect both the attenuation of the primary light beam and the scattered light. The optical system is integrated into a planar transparent polymethylmethacrylate substrate by micromilling of an optical freeform surface and electron beam evaporation of reflective layers following the concept of planar integrated free-space optical systems. We are able to detect 1 mg/L of the standards ISO 12103-A2 (fine test dust), -A3 (medium test dust), and -A4 (coarse test dust) and to determine the Sauter mean diameter of the particle size distribution.</description><subject>Attenuation</subject><subject>Dust</subject><subject>Emittance</subject><subject>Monitoring</subject><subject>Optimization</subject><subject>Particle mass</subject><subject>Sauter mean diameter</subject><issn>1559-128X</issn><issn>2155-3165</issn><issn>1539-4522</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNqFkT1PwzAQhi0EglLYmJFHBlL8GTtjVfFRqVIXkNgix7lURkkcbAep_55UBVamu-F5H53uReiGkgXluXhYbheSLghRmpATNGNUyozTXJ6i2bQWGWX6_QJdxvhBCJeiUOfognEqmC74DA3rPsEumAQ19kPyTTu62lkc9zFBhxsfcOd7l3xw_Q4PJiRnW8CdiRFb31vo0xR2vo-4MvEg6fHQmt4EDJ1LCUIWwIL7goDHyROv0Flj2gjXP3OO3p4eX1cv2Wb7vF4tN5llmqas4roWRgOh0IiGcZkLq6wGa3XOqJJC60oxqPNKyaaS2hb5FCTCFLzK64LzObo7eofgP0eIqexctNBOt4EfYzm9hStSkFz9j1JJFSFakwm9P6I2-BgDNOUQXGfCvqSkPNRRLrelpOWxjgm__TGPVQf1H_z7f_4NBPCHGg</recordid><startdate>20121110</startdate><enddate>20121110</enddate><creator>Hofmann, Meike</creator><creator>Müller, Ralf</creator><creator>Stoebenau, Sebastian</creator><creator>Stauden, Thomas</creator><creator>Brodersen, Olaf</creator><creator>Sinzinger, Stefan</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20121110</creationdate><title>Integrated optofluidic system for monitoring particle mass concentrations based on planar emitter-receiver units</title><author>Hofmann, Meike ; Müller, Ralf ; Stoebenau, Sebastian ; Stauden, Thomas ; Brodersen, Olaf ; Sinzinger, Stefan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c281t-b38d4a8e01ef4f23564c7c8ecc862175488b72ed6b75fb58c96c2804a93b6d933</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Attenuation</topic><topic>Dust</topic><topic>Emittance</topic><topic>Monitoring</topic><topic>Optimization</topic><topic>Particle mass</topic><topic>Sauter mean diameter</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hofmann, Meike</creatorcontrib><creatorcontrib>Müller, Ralf</creatorcontrib><creatorcontrib>Stoebenau, Sebastian</creatorcontrib><creatorcontrib>Stauden, Thomas</creatorcontrib><creatorcontrib>Brodersen, Olaf</creatorcontrib><creatorcontrib>Sinzinger, Stefan</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Electronics & Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Applied optics (2004)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hofmann, Meike</au><au>Müller, Ralf</au><au>Stoebenau, Sebastian</au><au>Stauden, Thomas</au><au>Brodersen, Olaf</au><au>Sinzinger, Stefan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Integrated optofluidic system for monitoring particle mass concentrations based on planar emitter-receiver units</atitle><jtitle>Applied optics (2004)</jtitle><addtitle>Appl Opt</addtitle><date>2012-11-10</date><risdate>2012</risdate><volume>51</volume><issue>32</issue><spage>7800</spage><epage>7809</epage><pages>7800-7809</pages><issn>1559-128X</issn><eissn>2155-3165</eissn><eissn>1539-4522</eissn><abstract>We demonstrate an integrated optofluidic system for monitoring the particle mass concentration and the Sauter mean diameter of polydisperse flowing suspensions of water and standardized test dust. For optimum integration, a planar emitter-receiver unit is developed and fabricated on Si technology. A vertical cavity surface emitting laser at 850 nm serves as light source, and monolithically integrated segmented photodiodes detect both the attenuation of the primary light beam and the scattered light. The optical system is integrated into a planar transparent polymethylmethacrylate substrate by micromilling of an optical freeform surface and electron beam evaporation of reflective layers following the concept of planar integrated free-space optical systems. We are able to detect 1 mg/L of the standards ISO 12103-A2 (fine test dust), -A3 (medium test dust), and -A4 (coarse test dust) and to determine the Sauter mean diameter of the particle size distribution.</abstract><cop>United States</cop><pmid>23142893</pmid><doi>10.1364/AO.51.007800</doi><tpages>10</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1559-128X |
ispartof | Applied optics (2004), 2012-11, Vol.51 (32), p.7800-7809 |
issn | 1559-128X 2155-3165 1539-4522 |
language | eng |
recordid | cdi_proquest_miscellaneous_1283709067 |
source | Alma/SFX Local Collection; Optica Publishing Group Journals |
subjects | Attenuation Dust Emittance Monitoring Optimization Particle mass Sauter mean diameter |
title | Integrated optofluidic system for monitoring particle mass concentrations based on planar emitter-receiver units |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T12%3A46%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Integrated%20optofluidic%20system%20for%20monitoring%20particle%20mass%20concentrations%20based%20on%20planar%20emitter-receiver%20units&rft.jtitle=Applied%20optics%20(2004)&rft.au=Hofmann,%20Meike&rft.date=2012-11-10&rft.volume=51&rft.issue=32&rft.spage=7800&rft.epage=7809&rft.pages=7800-7809&rft.issn=1559-128X&rft.eissn=2155-3165&rft_id=info:doi/10.1364/AO.51.007800&rft_dat=%3Cproquest_cross%3E1283709067%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1151700880&rft_id=info:pmid/23142893&rfr_iscdi=true |