Experimental characterization of a prototype detector system for carbon ion radiography and tomography
Ion beams exhibit a finite range and an inverted depth-dose profile, the Bragg peak. These favorable physical properties allow excellent tumor-dose conformality. However, they introduce sensitivity to range uncertainties. Although these uncertainties are typically taken into account in treatment pla...
Gespeichert in:
Veröffentlicht in: | Physics in medicine & biology 2013-02, Vol.58 (3), p.413-427 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 427 |
---|---|
container_issue | 3 |
container_start_page | 413 |
container_title | Physics in medicine & biology |
container_volume | 58 |
creator | Rinaldi, I Brons, S Gordon, J Panse, R Voss, B Jäkel, O Parodi, K |
description | Ion beams exhibit a finite range and an inverted depth-dose profile, the Bragg peak. These favorable physical properties allow excellent tumor-dose conformality. However, they introduce sensitivity to range uncertainties. Although these uncertainties are typically taken into account in treatment planning, delivery of the intended dose to the patient has to be ensured daily to prevent underdosage of the tumor or overdosage of surrounding critical structures. Thus, imaging techniques play an increasingly important role for treatment planning and in situ monitoring in ion beam therapy. At the Heidelberg Ion Beam Therapy (HIT) center, a prototype detector system based on a stack of 61 ionization chambers has been assembled for the purpose of radiographic and tomographic imaging of transmitted energetic ions. Its applicability to ion-based transmission imaging was investigated experimentally. An extensive characterization of the set-up in terms of beam parameters and settings of the read-out electronics was performed. Overall, the findings of this work support the potential of an efficient experimental set-up as the range telescope equipped with high sensitivity and fast electronics to perform heavy ion radiography and tomography at HIT. |
doi_str_mv | 10.1088/0031-9155/58/3/413 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1273584656</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1273584656</sourcerecordid><originalsourceid>FETCH-LOGICAL-c408t-c2dc692d8d6ec142f115a1979c0a798eadae734b251b2c352ba8018cf9305aa53</originalsourceid><addsrcrecordid>eNp9kMtOwzAQRS0EoqXwAyyQl2xCPXacOktUlYdUiQ2srYnj0FRNHGxXonw9rlq6ZOWHzr2aOYTcAnsAptSUMQFZCVJOpZqKaQ7ijIxBFJAVsmDnZHwCRuQqhDVjAIrnl2TEBS8LLssxaRbfg_VtZ_uIG2pW6NHE9PGDsXU9dQ1FOngXXdwNltY2WhOdp2EXou1ok64GfZXIPe2xbt2nx2G1o9jXNLru-LwmFw1ugr05nhPy8bR4n79ky7fn1_njMjM5UzEzvDZFyWtVF9ZAzhsAiVDOSsNwViqLNdqZyCsuoeJGSF6hYqBMUwomEaWYkPtDb5r5a2tD1F0bjN1ssLduGzTwmZAqT34Syg-o8S4Ebxs9JA_odxqY3vvVe316r09LpYVOflPo7ti_rTpbnyJ_QhPwcABaN-i12_o-rftf4y8KM4Wk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1273584656</pqid></control><display><type>article</type><title>Experimental characterization of a prototype detector system for carbon ion radiography and tomography</title><source>MEDLINE</source><source>Institute of Physics Journals</source><creator>Rinaldi, I ; Brons, S ; Gordon, J ; Panse, R ; Voss, B ; Jäkel, O ; Parodi, K</creator><creatorcontrib>Rinaldi, I ; Brons, S ; Gordon, J ; Panse, R ; Voss, B ; Jäkel, O ; Parodi, K</creatorcontrib><description>Ion beams exhibit a finite range and an inverted depth-dose profile, the Bragg peak. These favorable physical properties allow excellent tumor-dose conformality. However, they introduce sensitivity to range uncertainties. Although these uncertainties are typically taken into account in treatment planning, delivery of the intended dose to the patient has to be ensured daily to prevent underdosage of the tumor or overdosage of surrounding critical structures. Thus, imaging techniques play an increasingly important role for treatment planning and in situ monitoring in ion beam therapy. At the Heidelberg Ion Beam Therapy (HIT) center, a prototype detector system based on a stack of 61 ionization chambers has been assembled for the purpose of radiographic and tomographic imaging of transmitted energetic ions. Its applicability to ion-based transmission imaging was investigated experimentally. An extensive characterization of the set-up in terms of beam parameters and settings of the read-out electronics was performed. Overall, the findings of this work support the potential of an efficient experimental set-up as the range telescope equipped with high sensitivity and fast electronics to perform heavy ion radiography and tomography at HIT.</description><identifier>ISSN: 0031-9155</identifier><identifier>EISSN: 1361-6560</identifier><identifier>DOI: 10.1088/0031-9155/58/3/413</identifier><identifier>PMID: 23296259</identifier><identifier>CODEN: PHMBA7</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>Calibration ; Carbon - chemistry ; Humans ; Radiation Dosage ; Radiography - instrumentation ; Tomography - instrumentation</subject><ispartof>Physics in medicine & biology, 2013-02, Vol.58 (3), p.413-427</ispartof><rights>2013 Institute of Physics and Engineering in Medicine</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c408t-c2dc692d8d6ec142f115a1979c0a798eadae734b251b2c352ba8018cf9305aa53</citedby><cites>FETCH-LOGICAL-c408t-c2dc692d8d6ec142f115a1979c0a798eadae734b251b2c352ba8018cf9305aa53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/0031-9155/58/3/413/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>315,782,786,27931,27932,53853,53900</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23296259$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Rinaldi, I</creatorcontrib><creatorcontrib>Brons, S</creatorcontrib><creatorcontrib>Gordon, J</creatorcontrib><creatorcontrib>Panse, R</creatorcontrib><creatorcontrib>Voss, B</creatorcontrib><creatorcontrib>Jäkel, O</creatorcontrib><creatorcontrib>Parodi, K</creatorcontrib><title>Experimental characterization of a prototype detector system for carbon ion radiography and tomography</title><title>Physics in medicine & biology</title><addtitle>PMB</addtitle><addtitle>Phys. Med. Biol</addtitle><description>Ion beams exhibit a finite range and an inverted depth-dose profile, the Bragg peak. These favorable physical properties allow excellent tumor-dose conformality. However, they introduce sensitivity to range uncertainties. Although these uncertainties are typically taken into account in treatment planning, delivery of the intended dose to the patient has to be ensured daily to prevent underdosage of the tumor or overdosage of surrounding critical structures. Thus, imaging techniques play an increasingly important role for treatment planning and in situ monitoring in ion beam therapy. At the Heidelberg Ion Beam Therapy (HIT) center, a prototype detector system based on a stack of 61 ionization chambers has been assembled for the purpose of radiographic and tomographic imaging of transmitted energetic ions. Its applicability to ion-based transmission imaging was investigated experimentally. An extensive characterization of the set-up in terms of beam parameters and settings of the read-out electronics was performed. Overall, the findings of this work support the potential of an efficient experimental set-up as the range telescope equipped with high sensitivity and fast electronics to perform heavy ion radiography and tomography at HIT.</description><subject>Calibration</subject><subject>Carbon - chemistry</subject><subject>Humans</subject><subject>Radiation Dosage</subject><subject>Radiography - instrumentation</subject><subject>Tomography - instrumentation</subject><issn>0031-9155</issn><issn>1361-6560</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kMtOwzAQRS0EoqXwAyyQl2xCPXacOktUlYdUiQ2srYnj0FRNHGxXonw9rlq6ZOWHzr2aOYTcAnsAptSUMQFZCVJOpZqKaQ7ijIxBFJAVsmDnZHwCRuQqhDVjAIrnl2TEBS8LLssxaRbfg_VtZ_uIG2pW6NHE9PGDsXU9dQ1FOngXXdwNltY2WhOdp2EXou1ok64GfZXIPe2xbt2nx2G1o9jXNLru-LwmFw1ugr05nhPy8bR4n79ky7fn1_njMjM5UzEzvDZFyWtVF9ZAzhsAiVDOSsNwViqLNdqZyCsuoeJGSF6hYqBMUwomEaWYkPtDb5r5a2tD1F0bjN1ssLduGzTwmZAqT34Syg-o8S4Ebxs9JA_odxqY3vvVe316r09LpYVOflPo7ti_rTpbnyJ_QhPwcABaN-i12_o-rftf4y8KM4Wk</recordid><startdate>20130207</startdate><enddate>20130207</enddate><creator>Rinaldi, I</creator><creator>Brons, S</creator><creator>Gordon, J</creator><creator>Panse, R</creator><creator>Voss, B</creator><creator>Jäkel, O</creator><creator>Parodi, K</creator><general>IOP Publishing</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20130207</creationdate><title>Experimental characterization of a prototype detector system for carbon ion radiography and tomography</title><author>Rinaldi, I ; Brons, S ; Gordon, J ; Panse, R ; Voss, B ; Jäkel, O ; Parodi, K</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c408t-c2dc692d8d6ec142f115a1979c0a798eadae734b251b2c352ba8018cf9305aa53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Calibration</topic><topic>Carbon - chemistry</topic><topic>Humans</topic><topic>Radiation Dosage</topic><topic>Radiography - instrumentation</topic><topic>Tomography - instrumentation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rinaldi, I</creatorcontrib><creatorcontrib>Brons, S</creatorcontrib><creatorcontrib>Gordon, J</creatorcontrib><creatorcontrib>Panse, R</creatorcontrib><creatorcontrib>Voss, B</creatorcontrib><creatorcontrib>Jäkel, O</creatorcontrib><creatorcontrib>Parodi, K</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physics in medicine & biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rinaldi, I</au><au>Brons, S</au><au>Gordon, J</au><au>Panse, R</au><au>Voss, B</au><au>Jäkel, O</au><au>Parodi, K</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Experimental characterization of a prototype detector system for carbon ion radiography and tomography</atitle><jtitle>Physics in medicine & biology</jtitle><stitle>PMB</stitle><addtitle>Phys. Med. Biol</addtitle><date>2013-02-07</date><risdate>2013</risdate><volume>58</volume><issue>3</issue><spage>413</spage><epage>427</epage><pages>413-427</pages><issn>0031-9155</issn><eissn>1361-6560</eissn><coden>PHMBA7</coden><abstract>Ion beams exhibit a finite range and an inverted depth-dose profile, the Bragg peak. These favorable physical properties allow excellent tumor-dose conformality. However, they introduce sensitivity to range uncertainties. Although these uncertainties are typically taken into account in treatment planning, delivery of the intended dose to the patient has to be ensured daily to prevent underdosage of the tumor or overdosage of surrounding critical structures. Thus, imaging techniques play an increasingly important role for treatment planning and in situ monitoring in ion beam therapy. At the Heidelberg Ion Beam Therapy (HIT) center, a prototype detector system based on a stack of 61 ionization chambers has been assembled for the purpose of radiographic and tomographic imaging of transmitted energetic ions. Its applicability to ion-based transmission imaging was investigated experimentally. An extensive characterization of the set-up in terms of beam parameters and settings of the read-out electronics was performed. Overall, the findings of this work support the potential of an efficient experimental set-up as the range telescope equipped with high sensitivity and fast electronics to perform heavy ion radiography and tomography at HIT.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>23296259</pmid><doi>10.1088/0031-9155/58/3/413</doi><tpages>15</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0031-9155 |
ispartof | Physics in medicine & biology, 2013-02, Vol.58 (3), p.413-427 |
issn | 0031-9155 1361-6560 |
language | eng |
recordid | cdi_proquest_miscellaneous_1273584656 |
source | MEDLINE; Institute of Physics Journals |
subjects | Calibration Carbon - chemistry Humans Radiation Dosage Radiography - instrumentation Tomography - instrumentation |
title | Experimental characterization of a prototype detector system for carbon ion radiography and tomography |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-03T23%3A56%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Experimental%20characterization%20of%20a%20prototype%20detector%20system%20for%20carbon%20ion%20radiography%20and%20tomography&rft.jtitle=Physics%20in%20medicine%20&%20biology&rft.au=Rinaldi,%20I&rft.date=2013-02-07&rft.volume=58&rft.issue=3&rft.spage=413&rft.epage=427&rft.pages=413-427&rft.issn=0031-9155&rft.eissn=1361-6560&rft.coden=PHMBA7&rft_id=info:doi/10.1088/0031-9155/58/3/413&rft_dat=%3Cproquest_cross%3E1273584656%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1273584656&rft_id=info:pmid/23296259&rfr_iscdi=true |