Robotic assistance and general anaesthesia improve catheter stability and increase signal attenuation during atrial fibrillation ablation

Recurrent arrhythmias after ablation procedures are often caused by recovery of ablated tissue. Robotic catheter manipulation systems increase catheter tip stability which improves energy delivery and could produce more transmural lesions. We tested this assertion using bipolar voltage attenuation a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Europace (London, England) England), 2013-01, Vol.15 (1), p.41-47
Hauptverfasser: Malcolme-Lawes, Louisa C, Lim, Phang Boon, Koa-Wing, Michael, Whinnett, Zachary I, Jamil-Copley, Shahnaz, Hayat, Sajad, Francis, Darrel P, Kojodjojo, Pipin, Davies, D Wyn, Peters, Nicholas S, Kanagaratnam, Prapa
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 47
container_issue 1
container_start_page 41
container_title Europace (London, England)
container_volume 15
creator Malcolme-Lawes, Louisa C
Lim, Phang Boon
Koa-Wing, Michael
Whinnett, Zachary I
Jamil-Copley, Shahnaz
Hayat, Sajad
Francis, Darrel P
Kojodjojo, Pipin
Davies, D Wyn
Peters, Nicholas S
Kanagaratnam, Prapa
description Recurrent arrhythmias after ablation procedures are often caused by recovery of ablated tissue. Robotic catheter manipulation systems increase catheter tip stability which improves energy delivery and could produce more transmural lesions. We tested this assertion using bipolar voltage attenuation as a marker of lesion quality comparing robotic and manual circumferential pulmonary vein ablation for atrial fibrillation (AF). Twenty patients were randomly assigned to robotic or manual AF ablation at standard radiofrequency (RF) settings for our institution (30 W 60 s manual, 25 W 30 s robotic, R30). A separate group of 10 consecutive patients underwent robotic ablation at increased RF duration, 25 W for 60 s (R60). Lesions were marked on an electroanatomic map before and after ablation to measure distance moved and change in bipolar electrogram amplitude during RF. A total of 1108 lesions were studied (761 robotic, 347 manual). A correlation was identified between voltage attenuation and catheter movement during RF (Spearman's rho -0.929, P < 0.001). The ablation catheter was more stable during robotic RF; 2.9 ± 2.3 mm (R30) and 2.6 ± 2.2 mm (R60), both significantly less than the manual group (4.3 ± 3.0 mm, P < 0.001). Despite improved stability, there was no difference in signal attenuation between the manual and R30 group. However, there was increased signal attenuation in the R60 group (52.4 ± 19.4%) compared with manual (47.7 ± 25.4%, P = 0.01). When procedures under general anaesthesia (GA) and conscious sedation were analysed separately, the improvement in signal attenuation in the R60 group was only significant in the procedures under GA. Robotically assisted ablation has the capability to deliver greater bipolar voltage attenuation compared with manual ablation with appropriate selection of RF parameters. General anaesthesia confers additional benefits of catheter stability and greater signal attenuation. These findings may have a significant impact on outcomes from AF ablation procedures.
doi_str_mv 10.1093/europace/eus244
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1238106167</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1238106167</sourcerecordid><originalsourceid>FETCH-LOGICAL-c338t-f15be7e7926fe5dc43df7c442701f5e2e94ea56484b0bd74944306a3af6ec8f13</originalsourceid><addsrcrecordid>eNo9UMtOwzAQtBCIlsKZG8qRS6ifSXxEFS8JCQnBOXKcdTFKnGI7SP0E_hqXtJx2NDsz2h2ELgm-IViyJYx-2CgNCQTK-RGaE8FoTrGkxwljKXNBqJyhsxA-McYlleIUzSiVRJRVNUc_r0MzRKszFYINUTkNmXJttgYHXnUJKwjxA4JVme03fviGTKtERPBZ0je2s3H7Z7FOe1ABsmDXbmeNEdyooh1c1o7eunWivE0bYxtvu25aqWYC5-jEqC7AxX4u0Pv93dvqMX9-eXha3T7nmrEq5oaIBkooJS0MiFZz1ppSc05LTIwACpKDEgWveIObtuSSc4YLxZQpQFeGsAW6nnLTM19jeq7ubdCQznEwjKEmlFUEF6Qok3Q5SbUfQvBg6o23vfLbmuB613996L-e-k-Oq3342PTQ_usPhbNf_yWImQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1238106167</pqid></control><display><type>article</type><title>Robotic assistance and general anaesthesia improve catheter stability and increase signal attenuation during atrial fibrillation ablation</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Oxford Journals Open Access Collection</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Malcolme-Lawes, Louisa C ; Lim, Phang Boon ; Koa-Wing, Michael ; Whinnett, Zachary I ; Jamil-Copley, Shahnaz ; Hayat, Sajad ; Francis, Darrel P ; Kojodjojo, Pipin ; Davies, D Wyn ; Peters, Nicholas S ; Kanagaratnam, Prapa</creator><creatorcontrib>Malcolme-Lawes, Louisa C ; Lim, Phang Boon ; Koa-Wing, Michael ; Whinnett, Zachary I ; Jamil-Copley, Shahnaz ; Hayat, Sajad ; Francis, Darrel P ; Kojodjojo, Pipin ; Davies, D Wyn ; Peters, Nicholas S ; Kanagaratnam, Prapa</creatorcontrib><description>Recurrent arrhythmias after ablation procedures are often caused by recovery of ablated tissue. Robotic catheter manipulation systems increase catheter tip stability which improves energy delivery and could produce more transmural lesions. We tested this assertion using bipolar voltage attenuation as a marker of lesion quality comparing robotic and manual circumferential pulmonary vein ablation for atrial fibrillation (AF). Twenty patients were randomly assigned to robotic or manual AF ablation at standard radiofrequency (RF) settings for our institution (30 W 60 s manual, 25 W 30 s robotic, R30). A separate group of 10 consecutive patients underwent robotic ablation at increased RF duration, 25 W for 60 s (R60). Lesions were marked on an electroanatomic map before and after ablation to measure distance moved and change in bipolar electrogram amplitude during RF. A total of 1108 lesions were studied (761 robotic, 347 manual). A correlation was identified between voltage attenuation and catheter movement during RF (Spearman's rho -0.929, P &lt; 0.001). The ablation catheter was more stable during robotic RF; 2.9 ± 2.3 mm (R30) and 2.6 ± 2.2 mm (R60), both significantly less than the manual group (4.3 ± 3.0 mm, P &lt; 0.001). Despite improved stability, there was no difference in signal attenuation between the manual and R30 group. However, there was increased signal attenuation in the R60 group (52.4 ± 19.4%) compared with manual (47.7 ± 25.4%, P = 0.01). When procedures under general anaesthesia (GA) and conscious sedation were analysed separately, the improvement in signal attenuation in the R60 group was only significant in the procedures under GA. Robotically assisted ablation has the capability to deliver greater bipolar voltage attenuation compared with manual ablation with appropriate selection of RF parameters. General anaesthesia confers additional benefits of catheter stability and greater signal attenuation. These findings may have a significant impact on outcomes from AF ablation procedures.</description><identifier>ISSN: 1099-5129</identifier><identifier>EISSN: 1532-2092</identifier><identifier>DOI: 10.1093/europace/eus244</identifier><identifier>PMID: 22915788</identifier><language>eng</language><publisher>England</publisher><subject>Anesthesia, General - methods ; Anesthetics, General - therapeutic use ; Atrial Fibrillation - diagnosis ; Atrial Fibrillation - surgery ; Catheter Ablation - methods ; Female ; Heart Conduction System - surgery ; Humans ; Male ; Middle Aged ; Pulmonary Veins - surgery ; Robotics - methods ; Surgery, Computer-Assisted - methods ; Treatment Outcome</subject><ispartof>Europace (London, England), 2013-01, Vol.15 (1), p.41-47</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c338t-f15be7e7926fe5dc43df7c442701f5e2e94ea56484b0bd74944306a3af6ec8f13</citedby><cites>FETCH-LOGICAL-c338t-f15be7e7926fe5dc43df7c442701f5e2e94ea56484b0bd74944306a3af6ec8f13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/22915788$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Malcolme-Lawes, Louisa C</creatorcontrib><creatorcontrib>Lim, Phang Boon</creatorcontrib><creatorcontrib>Koa-Wing, Michael</creatorcontrib><creatorcontrib>Whinnett, Zachary I</creatorcontrib><creatorcontrib>Jamil-Copley, Shahnaz</creatorcontrib><creatorcontrib>Hayat, Sajad</creatorcontrib><creatorcontrib>Francis, Darrel P</creatorcontrib><creatorcontrib>Kojodjojo, Pipin</creatorcontrib><creatorcontrib>Davies, D Wyn</creatorcontrib><creatorcontrib>Peters, Nicholas S</creatorcontrib><creatorcontrib>Kanagaratnam, Prapa</creatorcontrib><title>Robotic assistance and general anaesthesia improve catheter stability and increase signal attenuation during atrial fibrillation ablation</title><title>Europace (London, England)</title><addtitle>Europace</addtitle><description>Recurrent arrhythmias after ablation procedures are often caused by recovery of ablated tissue. Robotic catheter manipulation systems increase catheter tip stability which improves energy delivery and could produce more transmural lesions. We tested this assertion using bipolar voltage attenuation as a marker of lesion quality comparing robotic and manual circumferential pulmonary vein ablation for atrial fibrillation (AF). Twenty patients were randomly assigned to robotic or manual AF ablation at standard radiofrequency (RF) settings for our institution (30 W 60 s manual, 25 W 30 s robotic, R30). A separate group of 10 consecutive patients underwent robotic ablation at increased RF duration, 25 W for 60 s (R60). Lesions were marked on an electroanatomic map before and after ablation to measure distance moved and change in bipolar electrogram amplitude during RF. A total of 1108 lesions were studied (761 robotic, 347 manual). A correlation was identified between voltage attenuation and catheter movement during RF (Spearman's rho -0.929, P &lt; 0.001). The ablation catheter was more stable during robotic RF; 2.9 ± 2.3 mm (R30) and 2.6 ± 2.2 mm (R60), both significantly less than the manual group (4.3 ± 3.0 mm, P &lt; 0.001). Despite improved stability, there was no difference in signal attenuation between the manual and R30 group. However, there was increased signal attenuation in the R60 group (52.4 ± 19.4%) compared with manual (47.7 ± 25.4%, P = 0.01). When procedures under general anaesthesia (GA) and conscious sedation were analysed separately, the improvement in signal attenuation in the R60 group was only significant in the procedures under GA. Robotically assisted ablation has the capability to deliver greater bipolar voltage attenuation compared with manual ablation with appropriate selection of RF parameters. General anaesthesia confers additional benefits of catheter stability and greater signal attenuation. These findings may have a significant impact on outcomes from AF ablation procedures.</description><subject>Anesthesia, General - methods</subject><subject>Anesthetics, General - therapeutic use</subject><subject>Atrial Fibrillation - diagnosis</subject><subject>Atrial Fibrillation - surgery</subject><subject>Catheter Ablation - methods</subject><subject>Female</subject><subject>Heart Conduction System - surgery</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Pulmonary Veins - surgery</subject><subject>Robotics - methods</subject><subject>Surgery, Computer-Assisted - methods</subject><subject>Treatment Outcome</subject><issn>1099-5129</issn><issn>1532-2092</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9UMtOwzAQtBCIlsKZG8qRS6ifSXxEFS8JCQnBOXKcdTFKnGI7SP0E_hqXtJx2NDsz2h2ELgm-IViyJYx-2CgNCQTK-RGaE8FoTrGkxwljKXNBqJyhsxA-McYlleIUzSiVRJRVNUc_r0MzRKszFYINUTkNmXJttgYHXnUJKwjxA4JVme03fviGTKtERPBZ0je2s3H7Z7FOe1ABsmDXbmeNEdyooh1c1o7eunWivE0bYxtvu25aqWYC5-jEqC7AxX4u0Pv93dvqMX9-eXha3T7nmrEq5oaIBkooJS0MiFZz1ppSc05LTIwACpKDEgWveIObtuSSc4YLxZQpQFeGsAW6nnLTM19jeq7ubdCQznEwjKEmlFUEF6Qok3Q5SbUfQvBg6o23vfLbmuB613996L-e-k-Oq3342PTQ_usPhbNf_yWImQ</recordid><startdate>201301</startdate><enddate>201301</enddate><creator>Malcolme-Lawes, Louisa C</creator><creator>Lim, Phang Boon</creator><creator>Koa-Wing, Michael</creator><creator>Whinnett, Zachary I</creator><creator>Jamil-Copley, Shahnaz</creator><creator>Hayat, Sajad</creator><creator>Francis, Darrel P</creator><creator>Kojodjojo, Pipin</creator><creator>Davies, D Wyn</creator><creator>Peters, Nicholas S</creator><creator>Kanagaratnam, Prapa</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201301</creationdate><title>Robotic assistance and general anaesthesia improve catheter stability and increase signal attenuation during atrial fibrillation ablation</title><author>Malcolme-Lawes, Louisa C ; Lim, Phang Boon ; Koa-Wing, Michael ; Whinnett, Zachary I ; Jamil-Copley, Shahnaz ; Hayat, Sajad ; Francis, Darrel P ; Kojodjojo, Pipin ; Davies, D Wyn ; Peters, Nicholas S ; Kanagaratnam, Prapa</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c338t-f15be7e7926fe5dc43df7c442701f5e2e94ea56484b0bd74944306a3af6ec8f13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Anesthesia, General - methods</topic><topic>Anesthetics, General - therapeutic use</topic><topic>Atrial Fibrillation - diagnosis</topic><topic>Atrial Fibrillation - surgery</topic><topic>Catheter Ablation - methods</topic><topic>Female</topic><topic>Heart Conduction System - surgery</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Pulmonary Veins - surgery</topic><topic>Robotics - methods</topic><topic>Surgery, Computer-Assisted - methods</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Malcolme-Lawes, Louisa C</creatorcontrib><creatorcontrib>Lim, Phang Boon</creatorcontrib><creatorcontrib>Koa-Wing, Michael</creatorcontrib><creatorcontrib>Whinnett, Zachary I</creatorcontrib><creatorcontrib>Jamil-Copley, Shahnaz</creatorcontrib><creatorcontrib>Hayat, Sajad</creatorcontrib><creatorcontrib>Francis, Darrel P</creatorcontrib><creatorcontrib>Kojodjojo, Pipin</creatorcontrib><creatorcontrib>Davies, D Wyn</creatorcontrib><creatorcontrib>Peters, Nicholas S</creatorcontrib><creatorcontrib>Kanagaratnam, Prapa</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Europace (London, England)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Malcolme-Lawes, Louisa C</au><au>Lim, Phang Boon</au><au>Koa-Wing, Michael</au><au>Whinnett, Zachary I</au><au>Jamil-Copley, Shahnaz</au><au>Hayat, Sajad</au><au>Francis, Darrel P</au><au>Kojodjojo, Pipin</au><au>Davies, D Wyn</au><au>Peters, Nicholas S</au><au>Kanagaratnam, Prapa</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Robotic assistance and general anaesthesia improve catheter stability and increase signal attenuation during atrial fibrillation ablation</atitle><jtitle>Europace (London, England)</jtitle><addtitle>Europace</addtitle><date>2013-01</date><risdate>2013</risdate><volume>15</volume><issue>1</issue><spage>41</spage><epage>47</epage><pages>41-47</pages><issn>1099-5129</issn><eissn>1532-2092</eissn><abstract>Recurrent arrhythmias after ablation procedures are often caused by recovery of ablated tissue. Robotic catheter manipulation systems increase catheter tip stability which improves energy delivery and could produce more transmural lesions. We tested this assertion using bipolar voltage attenuation as a marker of lesion quality comparing robotic and manual circumferential pulmonary vein ablation for atrial fibrillation (AF). Twenty patients were randomly assigned to robotic or manual AF ablation at standard radiofrequency (RF) settings for our institution (30 W 60 s manual, 25 W 30 s robotic, R30). A separate group of 10 consecutive patients underwent robotic ablation at increased RF duration, 25 W for 60 s (R60). Lesions were marked on an electroanatomic map before and after ablation to measure distance moved and change in bipolar electrogram amplitude during RF. A total of 1108 lesions were studied (761 robotic, 347 manual). A correlation was identified between voltage attenuation and catheter movement during RF (Spearman's rho -0.929, P &lt; 0.001). The ablation catheter was more stable during robotic RF; 2.9 ± 2.3 mm (R30) and 2.6 ± 2.2 mm (R60), both significantly less than the manual group (4.3 ± 3.0 mm, P &lt; 0.001). Despite improved stability, there was no difference in signal attenuation between the manual and R30 group. However, there was increased signal attenuation in the R60 group (52.4 ± 19.4%) compared with manual (47.7 ± 25.4%, P = 0.01). When procedures under general anaesthesia (GA) and conscious sedation were analysed separately, the improvement in signal attenuation in the R60 group was only significant in the procedures under GA. Robotically assisted ablation has the capability to deliver greater bipolar voltage attenuation compared with manual ablation with appropriate selection of RF parameters. General anaesthesia confers additional benefits of catheter stability and greater signal attenuation. These findings may have a significant impact on outcomes from AF ablation procedures.</abstract><cop>England</cop><pmid>22915788</pmid><doi>10.1093/europace/eus244</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1099-5129
ispartof Europace (London, England), 2013-01, Vol.15 (1), p.41-47
issn 1099-5129
1532-2092
language eng
recordid cdi_proquest_miscellaneous_1238106167
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Oxford Journals Open Access Collection; PubMed Central; Alma/SFX Local Collection
subjects Anesthesia, General - methods
Anesthetics, General - therapeutic use
Atrial Fibrillation - diagnosis
Atrial Fibrillation - surgery
Catheter Ablation - methods
Female
Heart Conduction System - surgery
Humans
Male
Middle Aged
Pulmonary Veins - surgery
Robotics - methods
Surgery, Computer-Assisted - methods
Treatment Outcome
title Robotic assistance and general anaesthesia improve catheter stability and increase signal attenuation during atrial fibrillation ablation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T21%3A25%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Robotic%20assistance%20and%20general%20anaesthesia%20improve%20catheter%20stability%20and%20increase%20signal%20attenuation%20during%20atrial%20fibrillation%20ablation&rft.jtitle=Europace%20(London,%20England)&rft.au=Malcolme-Lawes,%20Louisa%20C&rft.date=2013-01&rft.volume=15&rft.issue=1&rft.spage=41&rft.epage=47&rft.pages=41-47&rft.issn=1099-5129&rft.eissn=1532-2092&rft_id=info:doi/10.1093/europace/eus244&rft_dat=%3Cproquest_cross%3E1238106167%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1238106167&rft_id=info:pmid/22915788&rfr_iscdi=true