Performance Evaluation of Different Design Alternatives for Microfabricated Nonporous Fused Silica Pillar Columns for Capillary Electrochromatography
An experimental study comparing the performance of different designs for microfabricated column structures for microchip capillary electrochromatography is presented. The work is a follow-up to our previously published modeling and simulation study on the same topic. Experiments were performed using...
Gespeichert in:
Veröffentlicht in: | Analytical chemistry (Washington) 2012-11, Vol.84 (22), p.9996-10004 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 10004 |
---|---|
container_issue | 22 |
container_start_page | 9996 |
container_title | Analytical chemistry (Washington) |
container_volume | 84 |
creator | Sukas, Sertan De Malsche, Wim Desmet, Gert Gardeniers, Han J.G.E |
description | An experimental study comparing the performance of different designs for microfabricated column structures for microchip capillary electrochromatography is presented. The work is a follow-up to our previously published modeling and simulation study on the same topic. Experiments were performed using fused silica microchips with and without octadecyltrimethoxysilane coating for nonretained and retained modes of operation, respectively. Showing the same trends as the modeling results, the foil shape produces a significant decrease in plate height with an increase of around 15% in mobile phase velocity in nonretained measurements of Coumarin 480 (C480). Measured plate heights at 1 kV/cm applied electric field were 0.77, 1.33, and 1.42 μm for foil, diamond, and hexagon, respectively. Chromatographic runs of C480 yielded minimal plate height values of 1.85 and 3.28 μm for foil and diamond, respectively. The optimization of the shape and placement of the structures appeared to have a considerable impact on the achievable performance. |
doi_str_mv | 10.1021/ac302450z |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1179550152</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1179550152</sourcerecordid><originalsourceid>FETCH-LOGICAL-a373t-8cb8f54838897f8b9a29b57bd7393b424b699d93ae265bc2e96a96af4716fea23</originalsourceid><addsrcrecordid>eNplkV1rFDEUhoModq1e-AckIIJejOZjkkkuy3arQtWCej2cZJM2JTMZk5lC_R_-X9Pu2opCICTnOV_vi9BzSt5Swug7sJywVpCfD9CKCkYaqRR7iFaEEN6wjpAD9KSUS0IoJVQ-RgeMUyK5FCv068xln_IAo3V4cwVxgTmkESePj4P3LrtxxseuhPMRH8XZ5bHGr1zBNQl_CjYnDyYHC7Pb4s9pnFJOS8EnS6nvryHWCD4LMULG6xSXYdxlrmG6_bzGm-jsnJO9yGmAOZ1nmC6un6JHHmJxz_b3Ifp-svm2_tCcfnn_cX102gDv-Nwoa5QXreJK6c4ro4FpIzqz7bjmpmWtkVpvNQfHpDCWOS2hHt92VHoHjB-i17u6U04_FlfmfgjFujrZ6OoaPaWdFoJUTSv68h_0Mi1VjXhLKd2Slt5Qb3ZUFaaU7Hw_5TDUPXtK-huv-juvKvtiX3Exg9vekX_MqcCrPQDFQvS5mhTKPSdlK4Tu7jmw5a-p_mv4G4ORqc8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1178940412</pqid></control><display><type>article</type><title>Performance Evaluation of Different Design Alternatives for Microfabricated Nonporous Fused Silica Pillar Columns for Capillary Electrochromatography</title><source>ACS Publications</source><creator>Sukas, Sertan ; De Malsche, Wim ; Desmet, Gert ; Gardeniers, Han J.G.E</creator><creatorcontrib>Sukas, Sertan ; De Malsche, Wim ; Desmet, Gert ; Gardeniers, Han J.G.E</creatorcontrib><description>An experimental study comparing the performance of different designs for microfabricated column structures for microchip capillary electrochromatography is presented. The work is a follow-up to our previously published modeling and simulation study on the same topic. Experiments were performed using fused silica microchips with and without octadecyltrimethoxysilane coating for nonretained and retained modes of operation, respectively. Showing the same trends as the modeling results, the foil shape produces a significant decrease in plate height with an increase of around 15% in mobile phase velocity in nonretained measurements of Coumarin 480 (C480). Measured plate heights at 1 kV/cm applied electric field were 0.77, 1.33, and 1.42 μm for foil, diamond, and hexagon, respectively. Chromatographic runs of C480 yielded minimal plate height values of 1.85 and 3.28 μm for foil and diamond, respectively. The optimization of the shape and placement of the structures appeared to have a considerable impact on the achievable performance.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/ac302450z</identifier><identifier>PMID: 23106365</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>Washington, DC: American Chemical Society</publisher><subject>Analytical chemistry ; Chemistry ; Chromatographic methods and physical methods associated with chromatography ; Chromatography ; Design optimization ; Exact sciences and technology ; Other chromatographic methods ; Semiconductors ; Silica ; Simulation</subject><ispartof>Analytical chemistry (Washington), 2012-11, Vol.84 (22), p.9996-10004</ispartof><rights>Copyright © 2012 American Chemical Society</rights><rights>2014 INIST-CNRS</rights><rights>Copyright American Chemical Society Nov 20, 2012</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a373t-8cb8f54838897f8b9a29b57bd7393b424b699d93ae265bc2e96a96af4716fea23</citedby><cites>FETCH-LOGICAL-a373t-8cb8f54838897f8b9a29b57bd7393b424b699d93ae265bc2e96a96af4716fea23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/ac302450z$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/ac302450z$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,776,780,2752,27053,27901,27902,56713,56763</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=26645597$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23106365$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sukas, Sertan</creatorcontrib><creatorcontrib>De Malsche, Wim</creatorcontrib><creatorcontrib>Desmet, Gert</creatorcontrib><creatorcontrib>Gardeniers, Han J.G.E</creatorcontrib><title>Performance Evaluation of Different Design Alternatives for Microfabricated Nonporous Fused Silica Pillar Columns for Capillary Electrochromatography</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>An experimental study comparing the performance of different designs for microfabricated column structures for microchip capillary electrochromatography is presented. The work is a follow-up to our previously published modeling and simulation study on the same topic. Experiments were performed using fused silica microchips with and without octadecyltrimethoxysilane coating for nonretained and retained modes of operation, respectively. Showing the same trends as the modeling results, the foil shape produces a significant decrease in plate height with an increase of around 15% in mobile phase velocity in nonretained measurements of Coumarin 480 (C480). Measured plate heights at 1 kV/cm applied electric field were 0.77, 1.33, and 1.42 μm for foil, diamond, and hexagon, respectively. Chromatographic runs of C480 yielded minimal plate height values of 1.85 and 3.28 μm for foil and diamond, respectively. The optimization of the shape and placement of the structures appeared to have a considerable impact on the achievable performance.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Chromatographic methods and physical methods associated with chromatography</subject><subject>Chromatography</subject><subject>Design optimization</subject><subject>Exact sciences and technology</subject><subject>Other chromatographic methods</subject><subject>Semiconductors</subject><subject>Silica</subject><subject>Simulation</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNplkV1rFDEUhoModq1e-AckIIJejOZjkkkuy3arQtWCej2cZJM2JTMZk5lC_R_-X9Pu2opCICTnOV_vi9BzSt5Swug7sJywVpCfD9CKCkYaqRR7iFaEEN6wjpAD9KSUS0IoJVQ-RgeMUyK5FCv068xln_IAo3V4cwVxgTmkESePj4P3LrtxxseuhPMRH8XZ5bHGr1zBNQl_CjYnDyYHC7Pb4s9pnFJOS8EnS6nvryHWCD4LMULG6xSXYdxlrmG6_bzGm-jsnJO9yGmAOZ1nmC6un6JHHmJxz_b3Ifp-svm2_tCcfnn_cX102gDv-Nwoa5QXreJK6c4ro4FpIzqz7bjmpmWtkVpvNQfHpDCWOS2hHt92VHoHjB-i17u6U04_FlfmfgjFujrZ6OoaPaWdFoJUTSv68h_0Mi1VjXhLKd2Slt5Qb3ZUFaaU7Hw_5TDUPXtK-huv-juvKvtiX3Exg9vekX_MqcCrPQDFQvS5mhTKPSdlK4Tu7jmw5a-p_mv4G4ORqc8</recordid><startdate>20121120</startdate><enddate>20121120</enddate><creator>Sukas, Sertan</creator><creator>De Malsche, Wim</creator><creator>Desmet, Gert</creator><creator>Gardeniers, Han J.G.E</creator><general>American Chemical Society</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20121120</creationdate><title>Performance Evaluation of Different Design Alternatives for Microfabricated Nonporous Fused Silica Pillar Columns for Capillary Electrochromatography</title><author>Sukas, Sertan ; De Malsche, Wim ; Desmet, Gert ; Gardeniers, Han J.G.E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a373t-8cb8f54838897f8b9a29b57bd7393b424b699d93ae265bc2e96a96af4716fea23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Chromatographic methods and physical methods associated with chromatography</topic><topic>Chromatography</topic><topic>Design optimization</topic><topic>Exact sciences and technology</topic><topic>Other chromatographic methods</topic><topic>Semiconductors</topic><topic>Silica</topic><topic>Simulation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sukas, Sertan</creatorcontrib><creatorcontrib>De Malsche, Wim</creatorcontrib><creatorcontrib>Desmet, Gert</creatorcontrib><creatorcontrib>Gardeniers, Han J.G.E</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sukas, Sertan</au><au>De Malsche, Wim</au><au>Desmet, Gert</au><au>Gardeniers, Han J.G.E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Performance Evaluation of Different Design Alternatives for Microfabricated Nonporous Fused Silica Pillar Columns for Capillary Electrochromatography</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2012-11-20</date><risdate>2012</risdate><volume>84</volume><issue>22</issue><spage>9996</spage><epage>10004</epage><pages>9996-10004</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>An experimental study comparing the performance of different designs for microfabricated column structures for microchip capillary electrochromatography is presented. The work is a follow-up to our previously published modeling and simulation study on the same topic. Experiments were performed using fused silica microchips with and without octadecyltrimethoxysilane coating for nonretained and retained modes of operation, respectively. Showing the same trends as the modeling results, the foil shape produces a significant decrease in plate height with an increase of around 15% in mobile phase velocity in nonretained measurements of Coumarin 480 (C480). Measured plate heights at 1 kV/cm applied electric field were 0.77, 1.33, and 1.42 μm for foil, diamond, and hexagon, respectively. Chromatographic runs of C480 yielded minimal plate height values of 1.85 and 3.28 μm for foil and diamond, respectively. The optimization of the shape and placement of the structures appeared to have a considerable impact on the achievable performance.</abstract><cop>Washington, DC</cop><pub>American Chemical Society</pub><pmid>23106365</pmid><doi>10.1021/ac302450z</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2700 |
ispartof | Analytical chemistry (Washington), 2012-11, Vol.84 (22), p.9996-10004 |
issn | 0003-2700 1520-6882 |
language | eng |
recordid | cdi_proquest_miscellaneous_1179550152 |
source | ACS Publications |
subjects | Analytical chemistry Chemistry Chromatographic methods and physical methods associated with chromatography Chromatography Design optimization Exact sciences and technology Other chromatographic methods Semiconductors Silica Simulation |
title | Performance Evaluation of Different Design Alternatives for Microfabricated Nonporous Fused Silica Pillar Columns for Capillary Electrochromatography |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T00%3A04%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Performance%20Evaluation%20of%20Different%20Design%20Alternatives%20for%20Microfabricated%20Nonporous%20Fused%20Silica%20Pillar%20Columns%20for%20Capillary%20Electrochromatography&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Sukas,%20Sertan&rft.date=2012-11-20&rft.volume=84&rft.issue=22&rft.spage=9996&rft.epage=10004&rft.pages=9996-10004&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/ac302450z&rft_dat=%3Cproquest_cross%3E1179550152%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1178940412&rft_id=info:pmid/23106365&rfr_iscdi=true |