Evaluating the impact of an ammonia-based post-combustion CO sub(2) capture process on a steam power plant with different cooling water temperatures

The use of aqueous ammonia is a promising option to capture carbon dioxide from the flue gas of coal-fired power plants. Compared to a capture process using monoethanolamine (MEA), the use of ammonia can reduce the heat requirement of the CO sub(2) desorption significantly, although an additional ef...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of greenhouse gas control 2012-09, Vol.10, p.1-14
Hauptverfasser: Linnenberg, Sebastian, Darde, Victor, Oexmann, Jochen, Kather, Alfons, van Well, Willy JM, Thomsen, Kaj
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 14
container_issue
container_start_page 1
container_title International journal of greenhouse gas control
container_volume 10
creator Linnenberg, Sebastian
Darde, Victor
Oexmann, Jochen
Kather, Alfons
van Well, Willy JM
Thomsen, Kaj
description The use of aqueous ammonia is a promising option to capture carbon dioxide from the flue gas of coal-fired power plants. Compared to a capture process using monoethanolamine (MEA), the use of ammonia can reduce the heat requirement of the CO sub(2) desorption significantly, although an additional effort is necessary to provide the cooling of the process. To allow for a fair evaluation of the integration of this CO sub(2) capture process into a power plant process, an overall process evaluation is carried out. The use of detailed models of the power plant, of the compressor and of the CO sub(2) capture process enables the calculation of the power loss due to the steam extraction as well as due to the required auxiliary power for CO sub(2) compression, solvent and cooling pumps and mechanical chillers. To study the influence of the cold end of the process, two power plants with different cooling water temperatures are analysed. Additionally, two different process configurations of the capture plant, with either one single absorber or two absorbers connected in series where the first absorber captures the majority of the CO sub(2) and the second limits the NH sub(3) slip, are evaluated. The influence of the main process parameters (desorber pressure, solvent circulation rate, solvent recycling rate and chilling temperature) are evaluated and the optimal configuration with respect to the overall net efficiency penalty is determined. The study shows that the configuration of the process with absorption at low temperature (approximately 10 degree C) with or without precipitation of ammonium carbonate compounds leads to a lower net efficiency penalty than an MEA-based process, assuming that low temperature cooling water is available. An estimate of the size of the absorber shows that the absorber columns of an ammonia-based process are significantly higher than the ones required for an MEA-based process.
doi_str_mv 10.1016/j.ijggc.2012.05.003
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_1125224690</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1125224690</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_11252246903</originalsourceid><addsrcrecordid>eNqVjc1OwzAQhH0AifLzBFz2WA4JttOEcq6KuHHhXm3cTeoojk12TV-EByaVeAFOo9F8M6PUo9Gl0aZ5Hko_9L0rrTa21HWpdXWlVual1kW9rZobdcs8aN0Ys9mu1M_-G8eM4qce5ETgQ0InEDvACTCEOHksWmQ6QooshYuhzSw-TrD7AM7t2j6BwyR5JkhzdMQMS4jAQhiW0plmSCNOAmcvJzj6rqOZFutiHC-3Z5QFEQqJZrzs8L267nBkevjTO7V-23_u3ovl4CsTyyF4djQuqxQzH4yxtbWb5lVX_0B_AaMrYjE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1125224690</pqid></control><display><type>article</type><title>Evaluating the impact of an ammonia-based post-combustion CO sub(2) capture process on a steam power plant with different cooling water temperatures</title><source>Access via ScienceDirect (Elsevier)</source><creator>Linnenberg, Sebastian ; Darde, Victor ; Oexmann, Jochen ; Kather, Alfons ; van Well, Willy JM ; Thomsen, Kaj</creator><creatorcontrib>Linnenberg, Sebastian ; Darde, Victor ; Oexmann, Jochen ; Kather, Alfons ; van Well, Willy JM ; Thomsen, Kaj</creatorcontrib><description>The use of aqueous ammonia is a promising option to capture carbon dioxide from the flue gas of coal-fired power plants. Compared to a capture process using monoethanolamine (MEA), the use of ammonia can reduce the heat requirement of the CO sub(2) desorption significantly, although an additional effort is necessary to provide the cooling of the process. To allow for a fair evaluation of the integration of this CO sub(2) capture process into a power plant process, an overall process evaluation is carried out. The use of detailed models of the power plant, of the compressor and of the CO sub(2) capture process enables the calculation of the power loss due to the steam extraction as well as due to the required auxiliary power for CO sub(2) compression, solvent and cooling pumps and mechanical chillers. To study the influence of the cold end of the process, two power plants with different cooling water temperatures are analysed. Additionally, two different process configurations of the capture plant, with either one single absorber or two absorbers connected in series where the first absorber captures the majority of the CO sub(2) and the second limits the NH sub(3) slip, are evaluated. The influence of the main process parameters (desorber pressure, solvent circulation rate, solvent recycling rate and chilling temperature) are evaluated and the optimal configuration with respect to the overall net efficiency penalty is determined. The study shows that the configuration of the process with absorption at low temperature (approximately 10 degree C) with or without precipitation of ammonium carbonate compounds leads to a lower net efficiency penalty than an MEA-based process, assuming that low temperature cooling water is available. An estimate of the size of the absorber shows that the absorber columns of an ammonia-based process are significantly higher than the ones required for an MEA-based process.</description><identifier>ISSN: 1750-5836</identifier><identifier>DOI: 10.1016/j.ijggc.2012.05.003</identifier><language>eng</language><subject>Absorption</subject><ispartof>International journal of greenhouse gas control, 2012-09, Vol.10, p.1-14</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,27928,27929</link.rule.ids></links><search><creatorcontrib>Linnenberg, Sebastian</creatorcontrib><creatorcontrib>Darde, Victor</creatorcontrib><creatorcontrib>Oexmann, Jochen</creatorcontrib><creatorcontrib>Kather, Alfons</creatorcontrib><creatorcontrib>van Well, Willy JM</creatorcontrib><creatorcontrib>Thomsen, Kaj</creatorcontrib><title>Evaluating the impact of an ammonia-based post-combustion CO sub(2) capture process on a steam power plant with different cooling water temperatures</title><title>International journal of greenhouse gas control</title><description>The use of aqueous ammonia is a promising option to capture carbon dioxide from the flue gas of coal-fired power plants. Compared to a capture process using monoethanolamine (MEA), the use of ammonia can reduce the heat requirement of the CO sub(2) desorption significantly, although an additional effort is necessary to provide the cooling of the process. To allow for a fair evaluation of the integration of this CO sub(2) capture process into a power plant process, an overall process evaluation is carried out. The use of detailed models of the power plant, of the compressor and of the CO sub(2) capture process enables the calculation of the power loss due to the steam extraction as well as due to the required auxiliary power for CO sub(2) compression, solvent and cooling pumps and mechanical chillers. To study the influence of the cold end of the process, two power plants with different cooling water temperatures are analysed. Additionally, two different process configurations of the capture plant, with either one single absorber or two absorbers connected in series where the first absorber captures the majority of the CO sub(2) and the second limits the NH sub(3) slip, are evaluated. The influence of the main process parameters (desorber pressure, solvent circulation rate, solvent recycling rate and chilling temperature) are evaluated and the optimal configuration with respect to the overall net efficiency penalty is determined. The study shows that the configuration of the process with absorption at low temperature (approximately 10 degree C) with or without precipitation of ammonium carbonate compounds leads to a lower net efficiency penalty than an MEA-based process, assuming that low temperature cooling water is available. An estimate of the size of the absorber shows that the absorber columns of an ammonia-based process are significantly higher than the ones required for an MEA-based process.</description><subject>Absorption</subject><issn>1750-5836</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNqVjc1OwzAQhH0AifLzBFz2WA4JttOEcq6KuHHhXm3cTeoojk12TV-EByaVeAFOo9F8M6PUo9Gl0aZ5Hko_9L0rrTa21HWpdXWlVual1kW9rZobdcs8aN0Ys9mu1M_-G8eM4qce5ETgQ0InEDvACTCEOHksWmQ6QooshYuhzSw-TrD7AM7t2j6BwyR5JkhzdMQMS4jAQhiW0plmSCNOAmcvJzj6rqOZFutiHC-3Z5QFEQqJZrzs8L267nBkevjTO7V-23_u3ovl4CsTyyF4djQuqxQzH4yxtbWb5lVX_0B_AaMrYjE</recordid><startdate>20120901</startdate><enddate>20120901</enddate><creator>Linnenberg, Sebastian</creator><creator>Darde, Victor</creator><creator>Oexmann, Jochen</creator><creator>Kather, Alfons</creator><creator>van Well, Willy JM</creator><creator>Thomsen, Kaj</creator><scope>7ST</scope><scope>7TV</scope><scope>7U6</scope><scope>C1K</scope><scope>SOI</scope></search><sort><creationdate>20120901</creationdate><title>Evaluating the impact of an ammonia-based post-combustion CO sub(2) capture process on a steam power plant with different cooling water temperatures</title><author>Linnenberg, Sebastian ; Darde, Victor ; Oexmann, Jochen ; Kather, Alfons ; van Well, Willy JM ; Thomsen, Kaj</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_11252246903</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Absorption</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Linnenberg, Sebastian</creatorcontrib><creatorcontrib>Darde, Victor</creatorcontrib><creatorcontrib>Oexmann, Jochen</creatorcontrib><creatorcontrib>Kather, Alfons</creatorcontrib><creatorcontrib>van Well, Willy JM</creatorcontrib><creatorcontrib>Thomsen, Kaj</creatorcontrib><collection>Environment Abstracts</collection><collection>Pollution Abstracts</collection><collection>Sustainability Science Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><jtitle>International journal of greenhouse gas control</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Linnenberg, Sebastian</au><au>Darde, Victor</au><au>Oexmann, Jochen</au><au>Kather, Alfons</au><au>van Well, Willy JM</au><au>Thomsen, Kaj</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluating the impact of an ammonia-based post-combustion CO sub(2) capture process on a steam power plant with different cooling water temperatures</atitle><jtitle>International journal of greenhouse gas control</jtitle><date>2012-09-01</date><risdate>2012</risdate><volume>10</volume><spage>1</spage><epage>14</epage><pages>1-14</pages><issn>1750-5836</issn><abstract>The use of aqueous ammonia is a promising option to capture carbon dioxide from the flue gas of coal-fired power plants. Compared to a capture process using monoethanolamine (MEA), the use of ammonia can reduce the heat requirement of the CO sub(2) desorption significantly, although an additional effort is necessary to provide the cooling of the process. To allow for a fair evaluation of the integration of this CO sub(2) capture process into a power plant process, an overall process evaluation is carried out. The use of detailed models of the power plant, of the compressor and of the CO sub(2) capture process enables the calculation of the power loss due to the steam extraction as well as due to the required auxiliary power for CO sub(2) compression, solvent and cooling pumps and mechanical chillers. To study the influence of the cold end of the process, two power plants with different cooling water temperatures are analysed. Additionally, two different process configurations of the capture plant, with either one single absorber or two absorbers connected in series where the first absorber captures the majority of the CO sub(2) and the second limits the NH sub(3) slip, are evaluated. The influence of the main process parameters (desorber pressure, solvent circulation rate, solvent recycling rate and chilling temperature) are evaluated and the optimal configuration with respect to the overall net efficiency penalty is determined. The study shows that the configuration of the process with absorption at low temperature (approximately 10 degree C) with or without precipitation of ammonium carbonate compounds leads to a lower net efficiency penalty than an MEA-based process, assuming that low temperature cooling water is available. An estimate of the size of the absorber shows that the absorber columns of an ammonia-based process are significantly higher than the ones required for an MEA-based process.</abstract><doi>10.1016/j.ijggc.2012.05.003</doi></addata></record>
fulltext fulltext
identifier ISSN: 1750-5836
ispartof International journal of greenhouse gas control, 2012-09, Vol.10, p.1-14
issn 1750-5836
language eng
recordid cdi_proquest_miscellaneous_1125224690
source Access via ScienceDirect (Elsevier)
subjects Absorption
title Evaluating the impact of an ammonia-based post-combustion CO sub(2) capture process on a steam power plant with different cooling water temperatures
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-16T23%3A40%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluating%20the%20impact%20of%20an%20ammonia-based%20post-combustion%20CO%20sub(2)%20capture%20process%20on%20a%20steam%20power%20plant%20with%20different%20cooling%20water%20temperatures&rft.jtitle=International%20journal%20of%20greenhouse%20gas%20control&rft.au=Linnenberg,%20Sebastian&rft.date=2012-09-01&rft.volume=10&rft.spage=1&rft.epage=14&rft.pages=1-14&rft.issn=1750-5836&rft_id=info:doi/10.1016/j.ijggc.2012.05.003&rft_dat=%3Cproquest%3E1125224690%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1125224690&rft_id=info:pmid/&rfr_iscdi=true