Rapid detection of illicit drugs in neat saliva using desorption/ionization on porous silicon

The ability to detect illicit drugs directly in oral fluids is of major interest for roadside, workplace and athlete drug testing. For example, roadside testing for popular drugs of abuse is being rolled out by law enforcement agencies following the introduction of legislation in several countries a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2012-09, Vol.99, p.791-798
Hauptverfasser: Guinan, Taryn, Ronci, Maurizio, Kobus, Hilton, Voelcker, Nicolas H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 798
container_issue
container_start_page 791
container_title Talanta (Oxford)
container_volume 99
creator Guinan, Taryn
Ronci, Maurizio
Kobus, Hilton
Voelcker, Nicolas H.
description The ability to detect illicit drugs directly in oral fluids is of major interest for roadside, workplace and athlete drug testing. For example, roadside testing for popular drugs of abuse is being rolled out by law enforcement agencies following the introduction of legislation in several countries all over the world. This paper reports on the direct analysis of methamphetamine, cocaine and 3,4-methylenedioxymethamphetamine in oral fluids using a hydrophobic porous silicon array as a combined drug extraction and concentration medium. Analysis by laser desorption/ionization time-of-flight mass spectrometry (MS) identified these drugs with a sensitivity in line with the suggested confirmatory cut-off concentrations, and 300 times faster. In addition, MS imaging demonstrated good spot-to-spot reproducibility of the signal. Our analytical approach is compatible with multiplexing and is therefore suitable for high-throughput analysis of samples obtained from drug testing in the field. Furthermore, the application of this analytical technology is not limited to illicit drugs or oral fluids. Indeed, we believe that this platform technology could be applied to the high-throughput analysis of diverse metabolites in body fluids. ► Fluorinated pSi surfaces were used to effectively extract illicit drugs from water and neat saliva. ► We demonstrate quantitation of illicit drugs in both water and saliva using desorption ionization on porous silicon (DIOS). ► Crystallization patterns were examined using DIOS imaging to confirm spot-to-spot reproducibility.
doi_str_mv 10.1016/j.talanta.2012.07.029
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1039343571</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0039914012006054</els_id><sourcerecordid>1039343571</sourcerecordid><originalsourceid>FETCH-LOGICAL-c461t-3602885f0e2efc512db893fbea726f99ac630c72330f473536b07198b5d22bf43</originalsourceid><addsrcrecordid>eNqFkcGKFDEQhoMo7uzqIyi5CF66t5LqTjonkUVdYUEQPUpIp5MlQ0_SJt0L69ObYUY9eijq8v1VxVeEvGLQMmDiet-uZjZxNS0HxluQLXD1hOzYILHBXuJTsgNA1SjWwQW5LGUPABwBn5MLzpWQgvc78uOrWcJEJ7c6u4YUafI0zHOwYaVT3u4LDZFGZ1ZazBweDN1KiPeVLykvx8B1rfDLnLKRLimnrdAS6ogUX5Bn3szFvTz3K_L944dvN7fN3ZdPn2_e3zW2E2xtUAAfht6D487bnvFpHBT60RnJhVfKWIFgJUcE30nsUYwgmRrGfuJ89B1ekbenuUtOPzdXVn0Ixbq5CnL1HM2qCOyqFVbR_oTanErJzuslh4PJjxXSR7N6r89m9dGsBqmr2Zp7fV6xjQc3_U39UVmBN2fAFGtmn020ofzjBA5KoajcuxPnqpCH4LIuNrho3RRy_YGeUvjPKb8BhyaaHQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1039343571</pqid></control><display><type>article</type><title>Rapid detection of illicit drugs in neat saliva using desorption/ionization on porous silicon</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Guinan, Taryn ; Ronci, Maurizio ; Kobus, Hilton ; Voelcker, Nicolas H.</creator><creatorcontrib>Guinan, Taryn ; Ronci, Maurizio ; Kobus, Hilton ; Voelcker, Nicolas H.</creatorcontrib><description>The ability to detect illicit drugs directly in oral fluids is of major interest for roadside, workplace and athlete drug testing. For example, roadside testing for popular drugs of abuse is being rolled out by law enforcement agencies following the introduction of legislation in several countries all over the world. This paper reports on the direct analysis of methamphetamine, cocaine and 3,4-methylenedioxymethamphetamine in oral fluids using a hydrophobic porous silicon array as a combined drug extraction and concentration medium. Analysis by laser desorption/ionization time-of-flight mass spectrometry (MS) identified these drugs with a sensitivity in line with the suggested confirmatory cut-off concentrations, and 300 times faster. In addition, MS imaging demonstrated good spot-to-spot reproducibility of the signal. Our analytical approach is compatible with multiplexing and is therefore suitable for high-throughput analysis of samples obtained from drug testing in the field. Furthermore, the application of this analytical technology is not limited to illicit drugs or oral fluids. Indeed, we believe that this platform technology could be applied to the high-throughput analysis of diverse metabolites in body fluids. ► Fluorinated pSi surfaces were used to effectively extract illicit drugs from water and neat saliva. ► We demonstrate quantitation of illicit drugs in both water and saliva using desorption ionization on porous silicon (DIOS). ► Crystallization patterns were examined using DIOS imaging to confirm spot-to-spot reproducibility.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/j.talanta.2012.07.029</identifier><identifier>PMID: 22967625</identifier><identifier>CODEN: TLNTA2</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Chemistry ; DIOS ; Exact sciences and technology ; Humans ; Illicit drug analysis ; MS imaging ; Porosity ; Porous silicon ; Saliva - chemistry ; Silicon - chemistry ; Spectrometric and optical methods ; Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization - methods ; Substance Abuse Detection - methods ; Time Factors</subject><ispartof>Talanta (Oxford), 2012-09, Vol.99, p.791-798</ispartof><rights>2012</rights><rights>2015 INIST-CNRS</rights><rights>Copyright © 2012. Published by Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c461t-3602885f0e2efc512db893fbea726f99ac630c72330f473536b07198b5d22bf43</citedby><cites>FETCH-LOGICAL-c461t-3602885f0e2efc512db893fbea726f99ac630c72330f473536b07198b5d22bf43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.talanta.2012.07.029$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,27922,27923,45993</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=26389936$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/22967625$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Guinan, Taryn</creatorcontrib><creatorcontrib>Ronci, Maurizio</creatorcontrib><creatorcontrib>Kobus, Hilton</creatorcontrib><creatorcontrib>Voelcker, Nicolas H.</creatorcontrib><title>Rapid detection of illicit drugs in neat saliva using desorption/ionization on porous silicon</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>The ability to detect illicit drugs directly in oral fluids is of major interest for roadside, workplace and athlete drug testing. For example, roadside testing for popular drugs of abuse is being rolled out by law enforcement agencies following the introduction of legislation in several countries all over the world. This paper reports on the direct analysis of methamphetamine, cocaine and 3,4-methylenedioxymethamphetamine in oral fluids using a hydrophobic porous silicon array as a combined drug extraction and concentration medium. Analysis by laser desorption/ionization time-of-flight mass spectrometry (MS) identified these drugs with a sensitivity in line with the suggested confirmatory cut-off concentrations, and 300 times faster. In addition, MS imaging demonstrated good spot-to-spot reproducibility of the signal. Our analytical approach is compatible with multiplexing and is therefore suitable for high-throughput analysis of samples obtained from drug testing in the field. Furthermore, the application of this analytical technology is not limited to illicit drugs or oral fluids. Indeed, we believe that this platform technology could be applied to the high-throughput analysis of diverse metabolites in body fluids. ► Fluorinated pSi surfaces were used to effectively extract illicit drugs from water and neat saliva. ► We demonstrate quantitation of illicit drugs in both water and saliva using desorption ionization on porous silicon (DIOS). ► Crystallization patterns were examined using DIOS imaging to confirm spot-to-spot reproducibility.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>DIOS</subject><subject>Exact sciences and technology</subject><subject>Humans</subject><subject>Illicit drug analysis</subject><subject>MS imaging</subject><subject>Porosity</subject><subject>Porous silicon</subject><subject>Saliva - chemistry</subject><subject>Silicon - chemistry</subject><subject>Spectrometric and optical methods</subject><subject>Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization - methods</subject><subject>Substance Abuse Detection - methods</subject><subject>Time Factors</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkcGKFDEQhoMo7uzqIyi5CF66t5LqTjonkUVdYUEQPUpIp5MlQ0_SJt0L69ObYUY9eijq8v1VxVeEvGLQMmDiet-uZjZxNS0HxluQLXD1hOzYILHBXuJTsgNA1SjWwQW5LGUPABwBn5MLzpWQgvc78uOrWcJEJ7c6u4YUafI0zHOwYaVT3u4LDZFGZ1ZazBweDN1KiPeVLykvx8B1rfDLnLKRLimnrdAS6ogUX5Bn3szFvTz3K_L944dvN7fN3ZdPn2_e3zW2E2xtUAAfht6D487bnvFpHBT60RnJhVfKWIFgJUcE30nsUYwgmRrGfuJ89B1ekbenuUtOPzdXVn0Ixbq5CnL1HM2qCOyqFVbR_oTanErJzuslh4PJjxXSR7N6r89m9dGsBqmr2Zp7fV6xjQc3_U39UVmBN2fAFGtmn020ofzjBA5KoajcuxPnqpCH4LIuNrho3RRy_YGeUvjPKb8BhyaaHQ</recordid><startdate>20120915</startdate><enddate>20120915</enddate><creator>Guinan, Taryn</creator><creator>Ronci, Maurizio</creator><creator>Kobus, Hilton</creator><creator>Voelcker, Nicolas H.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20120915</creationdate><title>Rapid detection of illicit drugs in neat saliva using desorption/ionization on porous silicon</title><author>Guinan, Taryn ; Ronci, Maurizio ; Kobus, Hilton ; Voelcker, Nicolas H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c461t-3602885f0e2efc512db893fbea726f99ac630c72330f473536b07198b5d22bf43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>DIOS</topic><topic>Exact sciences and technology</topic><topic>Humans</topic><topic>Illicit drug analysis</topic><topic>MS imaging</topic><topic>Porosity</topic><topic>Porous silicon</topic><topic>Saliva - chemistry</topic><topic>Silicon - chemistry</topic><topic>Spectrometric and optical methods</topic><topic>Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization - methods</topic><topic>Substance Abuse Detection - methods</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Guinan, Taryn</creatorcontrib><creatorcontrib>Ronci, Maurizio</creatorcontrib><creatorcontrib>Kobus, Hilton</creatorcontrib><creatorcontrib>Voelcker, Nicolas H.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Guinan, Taryn</au><au>Ronci, Maurizio</au><au>Kobus, Hilton</au><au>Voelcker, Nicolas H.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Rapid detection of illicit drugs in neat saliva using desorption/ionization on porous silicon</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>2012-09-15</date><risdate>2012</risdate><volume>99</volume><spage>791</spage><epage>798</epage><pages>791-798</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><coden>TLNTA2</coden><abstract>The ability to detect illicit drugs directly in oral fluids is of major interest for roadside, workplace and athlete drug testing. For example, roadside testing for popular drugs of abuse is being rolled out by law enforcement agencies following the introduction of legislation in several countries all over the world. This paper reports on the direct analysis of methamphetamine, cocaine and 3,4-methylenedioxymethamphetamine in oral fluids using a hydrophobic porous silicon array as a combined drug extraction and concentration medium. Analysis by laser desorption/ionization time-of-flight mass spectrometry (MS) identified these drugs with a sensitivity in line with the suggested confirmatory cut-off concentrations, and 300 times faster. In addition, MS imaging demonstrated good spot-to-spot reproducibility of the signal. Our analytical approach is compatible with multiplexing and is therefore suitable for high-throughput analysis of samples obtained from drug testing in the field. Furthermore, the application of this analytical technology is not limited to illicit drugs or oral fluids. Indeed, we believe that this platform technology could be applied to the high-throughput analysis of diverse metabolites in body fluids. ► Fluorinated pSi surfaces were used to effectively extract illicit drugs from water and neat saliva. ► We demonstrate quantitation of illicit drugs in both water and saliva using desorption ionization on porous silicon (DIOS). ► Crystallization patterns were examined using DIOS imaging to confirm spot-to-spot reproducibility.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>22967625</pmid><doi>10.1016/j.talanta.2012.07.029</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 2012-09, Vol.99, p.791-798
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_1039343571
source MEDLINE; ScienceDirect Journals (5 years ago - present)
subjects Analytical chemistry
Chemistry
DIOS
Exact sciences and technology
Humans
Illicit drug analysis
MS imaging
Porosity
Porous silicon
Saliva - chemistry
Silicon - chemistry
Spectrometric and optical methods
Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization - methods
Substance Abuse Detection - methods
Time Factors
title Rapid detection of illicit drugs in neat saliva using desorption/ionization on porous silicon
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T22%3A15%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Rapid%20detection%20of%20illicit%20drugs%20in%20neat%20saliva%20using%20desorption/ionization%20on%20porous%20silicon&rft.jtitle=Talanta%20(Oxford)&rft.au=Guinan,%20Taryn&rft.date=2012-09-15&rft.volume=99&rft.spage=791&rft.epage=798&rft.pages=791-798&rft.issn=0039-9140&rft.eissn=1873-3573&rft.coden=TLNTA2&rft_id=info:doi/10.1016/j.talanta.2012.07.029&rft_dat=%3Cproquest_cross%3E1039343571%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1039343571&rft_id=info:pmid/22967625&rft_els_id=S0039914012006054&rfr_iscdi=true