Sound Reflection from Overhead Stage Canopies Depending on Ceiling Modification

Reflecting structures placed over the stage in auditoria and concert halls should provide sound reflection in a way that enhances sound emission from the stage without causing acoustic defects in the interior. Model studies conducted by the authors were used to determine the relative level of sound...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Archives of acoustics 2012-06, Vol.37 (2), p.213-218
Hauptverfasser: Kamisiński, Tadeusz, Szeląg, Agata, Rubacha, Jarosław
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 218
container_issue 2
container_start_page 213
container_title Archives of acoustics
container_volume 37
creator Kamisiński, Tadeusz
Szeląg, Agata
Rubacha, Jarosław
description Reflecting structures placed over the stage in auditoria and concert halls should provide sound reflection in a way that enhances sound emission from the stage without causing acoustic defects in the interior. Model studies conducted by the authors were used to determine the relative level of sound reflection by reflecting structures as a function of frequency for a number of geometric configurations and materials. Analysis of the results allowed drawing conclusions about the effect of modifications of the ceiling over the reflecting panels on the quality of the sound reflected from them. It was shown that modification of the ceiling over the reflecting panels by employing highly sound absorbing materials significantly improved the characteristics of the reflected sound. Also, certain configurations of elements located in the space under the ceiling should be avoided, as the experiments indicated the occurrence of adverse acoustic effects.
doi_str_mv 10.2478/v10168-012-0028-1
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1038254617</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2929295121</sourcerecordid><originalsourceid>FETCH-LOGICAL-c484t-32b85900f818df57204bca5e925f915aa528a9f7dfd18d12423240b5cfbd55b63</originalsourceid><addsrcrecordid>eNp1kEGLFDEQhYMoOMzuD_DW4MVLa1JJOumTyKyzKiuD7greQrpTGbP2dMake3X__WZoEREsKKoO33tVPEKeMfoShNKv7hhlja4pg5pS0DV7RFbAKa2hga-PyYoyrmpJlXxKznO-paV4C4q3K7K7jvPoqs_oB-ynEMfKp3iodneYvqF11fVk91ht7BiPAXN1gUccXRj3VSE3GIbT-jG64ENvT_Iz8sTbIeP577kmX7Zvbzbv6qvd5fvNm6u6F1pMNYdOy5ZSr5l2XiqgouutxBakb5m0VoK2rVfOuwIwEMBB0E72vnNSdg1fkxeL7zHFHzPmyRxC7nEY7IhxzoZRrkGKhqmCPv8HvY1zGst3hnFgpVvRFootVJ9izgm9OaZwsOm-WJlTymZJ2ZSUzSnlIl6T14vmpx0mTA73ab4vy18H_qtVAIwXh3pxCHnCX39O2vTdNIoraT7dCNN82F5ciq02W_4A1MuQ4w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1321132949</pqid></control><display><type>article</type><title>Sound Reflection from Overhead Stage Canopies Depending on Ceiling Modification</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Kamisiński, Tadeusz ; Szeląg, Agata ; Rubacha, Jarosław</creator><creatorcontrib>Kamisiński, Tadeusz ; Szeląg, Agata ; Rubacha, Jarosław</creatorcontrib><description>Reflecting structures placed over the stage in auditoria and concert halls should provide sound reflection in a way that enhances sound emission from the stage without causing acoustic defects in the interior. Model studies conducted by the authors were used to determine the relative level of sound reflection by reflecting structures as a function of frequency for a number of geometric configurations and materials. Analysis of the results allowed drawing conclusions about the effect of modifications of the ceiling over the reflecting panels on the quality of the sound reflected from them. It was shown that modification of the ceiling over the reflecting panels by employing highly sound absorbing materials significantly improved the characteristics of the reflected sound. Also, certain configurations of elements located in the space under the ceiling should be avoided, as the experiments indicated the occurrence of adverse acoustic effects.</description><identifier>ISSN: 0137-5075</identifier><identifier>EISSN: 2300-262X</identifier><identifier>DOI: 10.2478/v10168-012-0028-1</identifier><language>eng</language><publisher>Warsaw: Versita</publisher><subject>Acoustics ; Canopies ; Ceilings ; Concerts ; Halls ; Panels ; reflecting structures ; Reflection ; room acoustic ; Sound ; sound reflection</subject><ispartof>Archives of acoustics, 2012-06, Vol.37 (2), p.213-218</ispartof><rights>Copyright Versita Jun 2012</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c484t-32b85900f818df57204bca5e925f915aa528a9f7dfd18d12423240b5cfbd55b63</citedby><cites>FETCH-LOGICAL-c484t-32b85900f818df57204bca5e925f915aa528a9f7dfd18d12423240b5cfbd55b63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782,27911,27912</link.rule.ids></links><search><creatorcontrib>Kamisiński, Tadeusz</creatorcontrib><creatorcontrib>Szeląg, Agata</creatorcontrib><creatorcontrib>Rubacha, Jarosław</creatorcontrib><title>Sound Reflection from Overhead Stage Canopies Depending on Ceiling Modification</title><title>Archives of acoustics</title><description>Reflecting structures placed over the stage in auditoria and concert halls should provide sound reflection in a way that enhances sound emission from the stage without causing acoustic defects in the interior. Model studies conducted by the authors were used to determine the relative level of sound reflection by reflecting structures as a function of frequency for a number of geometric configurations and materials. Analysis of the results allowed drawing conclusions about the effect of modifications of the ceiling over the reflecting panels on the quality of the sound reflected from them. It was shown that modification of the ceiling over the reflecting panels by employing highly sound absorbing materials significantly improved the characteristics of the reflected sound. Also, certain configurations of elements located in the space under the ceiling should be avoided, as the experiments indicated the occurrence of adverse acoustic effects.</description><subject>Acoustics</subject><subject>Canopies</subject><subject>Ceilings</subject><subject>Concerts</subject><subject>Halls</subject><subject>Panels</subject><subject>reflecting structures</subject><subject>Reflection</subject><subject>room acoustic</subject><subject>Sound</subject><subject>sound reflection</subject><issn>0137-5075</issn><issn>2300-262X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNp1kEGLFDEQhYMoOMzuD_DW4MVLa1JJOumTyKyzKiuD7greQrpTGbP2dMake3X__WZoEREsKKoO33tVPEKeMfoShNKv7hhlja4pg5pS0DV7RFbAKa2hga-PyYoyrmpJlXxKznO-paV4C4q3K7K7jvPoqs_oB-ynEMfKp3iodneYvqF11fVk91ht7BiPAXN1gUccXRj3VSE3GIbT-jG64ENvT_Iz8sTbIeP577kmX7Zvbzbv6qvd5fvNm6u6F1pMNYdOy5ZSr5l2XiqgouutxBakb5m0VoK2rVfOuwIwEMBB0E72vnNSdg1fkxeL7zHFHzPmyRxC7nEY7IhxzoZRrkGKhqmCPv8HvY1zGst3hnFgpVvRFootVJ9izgm9OaZwsOm-WJlTymZJ2ZSUzSnlIl6T14vmpx0mTA73ab4vy18H_qtVAIwXh3pxCHnCX39O2vTdNIoraT7dCNN82F5ciq02W_4A1MuQ4w</recordid><startdate>20120629</startdate><enddate>20120629</enddate><creator>Kamisiński, Tadeusz</creator><creator>Szeląg, Agata</creator><creator>Rubacha, Jarosław</creator><general>Versita</general><general>Polish Academy of Sciences</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>H8D</scope><scope>HCIFZ</scope><scope>L7M</scope><scope>P5Z</scope><scope>P62</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20120629</creationdate><title>Sound Reflection from Overhead Stage Canopies Depending on Ceiling Modification</title><author>Kamisiński, Tadeusz ; Szeląg, Agata ; Rubacha, Jarosław</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c484t-32b85900f818df57204bca5e925f915aa528a9f7dfd18d12423240b5cfbd55b63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Acoustics</topic><topic>Canopies</topic><topic>Ceilings</topic><topic>Concerts</topic><topic>Halls</topic><topic>Panels</topic><topic>reflecting structures</topic><topic>Reflection</topic><topic>room acoustic</topic><topic>Sound</topic><topic>sound reflection</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kamisiński, Tadeusz</creatorcontrib><creatorcontrib>Szeląg, Agata</creatorcontrib><creatorcontrib>Rubacha, Jarosław</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Aerospace Database</collection><collection>SciTech Premium Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Advanced Technologies &amp; Aerospace Database</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Archives of acoustics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kamisiński, Tadeusz</au><au>Szeląg, Agata</au><au>Rubacha, Jarosław</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sound Reflection from Overhead Stage Canopies Depending on Ceiling Modification</atitle><jtitle>Archives of acoustics</jtitle><date>2012-06-29</date><risdate>2012</risdate><volume>37</volume><issue>2</issue><spage>213</spage><epage>218</epage><pages>213-218</pages><issn>0137-5075</issn><eissn>2300-262X</eissn><abstract>Reflecting structures placed over the stage in auditoria and concert halls should provide sound reflection in a way that enhances sound emission from the stage without causing acoustic defects in the interior. Model studies conducted by the authors were used to determine the relative level of sound reflection by reflecting structures as a function of frequency for a number of geometric configurations and materials. Analysis of the results allowed drawing conclusions about the effect of modifications of the ceiling over the reflecting panels on the quality of the sound reflected from them. It was shown that modification of the ceiling over the reflecting panels by employing highly sound absorbing materials significantly improved the characteristics of the reflected sound. Also, certain configurations of elements located in the space under the ceiling should be avoided, as the experiments indicated the occurrence of adverse acoustic effects.</abstract><cop>Warsaw</cop><pub>Versita</pub><doi>10.2478/v10168-012-0028-1</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0137-5075
ispartof Archives of acoustics, 2012-06, Vol.37 (2), p.213-218
issn 0137-5075
2300-262X
language eng
recordid cdi_proquest_miscellaneous_1038254617
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Acoustics
Canopies
Ceilings
Concerts
Halls
Panels
reflecting structures
Reflection
room acoustic
Sound
sound reflection
title Sound Reflection from Overhead Stage Canopies Depending on Ceiling Modification
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T18%3A58%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sound%20Reflection%20from%20Overhead%20Stage%20Canopies%20Depending%20on%20Ceiling%20Modification&rft.jtitle=Archives%20of%20acoustics&rft.au=Kamisi%C5%84ski,%20Tadeusz&rft.date=2012-06-29&rft.volume=37&rft.issue=2&rft.spage=213&rft.epage=218&rft.pages=213-218&rft.issn=0137-5075&rft.eissn=2300-262X&rft_id=info:doi/10.2478/v10168-012-0028-1&rft_dat=%3Cproquest_cross%3E2929295121%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1321132949&rft_id=info:pmid/&rfr_iscdi=true