Software architecture for multi-bed FDK-based reconstruction in X-ray CT scanners

Highlights ► Comprehensive software architecture for small-animal CT. ► Covers all the steps from the system calibration to the volume reconstruction. ► Strategies for calibration and artifact correction are discussed. ► Takes advantage of system symmetries and allows for parallel reconstruction....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Computer methods and programs in biomedicine 2012-08, Vol.107 (2), p.218-232
Hauptverfasser: Abella, M, Vaquero, J.J, Sisniega, A, Pascau, J, Udías, A, García, V, Vidal, I, Desco, M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 232
container_issue 2
container_start_page 218
container_title Computer methods and programs in biomedicine
container_volume 107
creator Abella, M
Vaquero, J.J
Sisniega, A
Pascau, J
Udías, A
García, V
Vidal, I
Desco, M
description Highlights ► Comprehensive software architecture for small-animal CT. ► Covers all the steps from the system calibration to the volume reconstruction. ► Strategies for calibration and artifact correction are discussed. ► Takes advantage of system symmetries and allows for parallel reconstruction.
doi_str_mv 10.1016/j.cmpb.2011.06.008
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1034828008</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0169260711001738</els_id><sourcerecordid>1020051330</sourcerecordid><originalsourceid>FETCH-LOGICAL-c518t-af6f80bb1da44f215213d88f3316a79a33769f297fa22b0aa0c74eda28a4ba9b3</originalsourceid><addsrcrecordid>eNqNklGL1DAQx4Mo3t7pF_BB-iL40jpJ2jQFEWS9U_FA5E7wLUzTBLO26V6SKvvtTdlVwQfxKQn85p_hN0PIEwoVBSpe7Co97fuKAaUViApA3iMbKltWto1o7pNNhrqSCWjPyHmMOwBgTSMekjNGO5Ag5IZ8uplt-oHBFBj0V5eMTkt-2DkU0zImV_ZmKK7efCh7jPkWjJ59TGHRyc2-cL74UgY8FNvbImr03oT4iDywOEbz-HRekM9Xl7fbd-X1x7fvt6-vS91QmUq0wkroezpgXVtGG0b5IKXlnApsO-S8FZ1lXWuRsR4QQbe1GZBJrHvsen5Bnh9z92G-W0xManJRm3FEb-YlKgq8lkxmK_-BMoCGcg4ZZUdUhznGYKzaBzdhOGRIrdbVTq3W1WpdgVDH_Ken_KWfzPC75JfmDDw7AZg1jTag1y7-4UQOzq1m7uWRM1ncd2eCitoZr83gsvmkhtn9u49Xf5Xr0XmXf_xmDibu5iX4PBJFVWQK1M26H-t6UApAWy75T2aZs7Y</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1020051330</pqid></control><display><type>article</type><title>Software architecture for multi-bed FDK-based reconstruction in X-ray CT scanners</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Abella, M ; Vaquero, J.J ; Sisniega, A ; Pascau, J ; Udías, A ; García, V ; Vidal, I ; Desco, M</creator><creatorcontrib>Abella, M ; Vaquero, J.J ; Sisniega, A ; Pascau, J ; Udías, A ; García, V ; Vidal, I ; Desco, M</creatorcontrib><description>Highlights ► Comprehensive software architecture for small-animal CT. ► Covers all the steps from the system calibration to the volume reconstruction. ► Strategies for calibration and artifact correction are discussed. ► Takes advantage of system symmetries and allows for parallel reconstruction.</description><identifier>ISSN: 0169-2607</identifier><identifier>EISSN: 1872-7565</identifier><identifier>DOI: 10.1016/j.cmpb.2011.06.008</identifier><identifier>PMID: 21908068</identifier><language>eng</language><publisher>Kidlington: Elsevier Ireland Ltd</publisher><subject>Algorithms ; Animals ; Biological and medical sciences ; Cone-beam ; CT artifacts ; FDK ; Internal Medicine ; Medical sciences ; Mice ; Other ; Radiographic Image Enhancement - methods ; Radiographic Image Interpretation, Computer-Assisted - methods ; Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects) ; Reconstruction ; Reproducibility of Results ; Sensitivity and Specificity ; Software ; Technology. Biomaterials. Equipments. Material. Instrumentation ; Tomography, X-Ray Computed - methods ; Tomography, X-Ray Computed - veterinary ; Whole Body Imaging - methods ; Whole Body Imaging - veterinary ; X-ray computed tomography</subject><ispartof>Computer methods and programs in biomedicine, 2012-08, Vol.107 (2), p.218-232</ispartof><rights>Elsevier Ireland Ltd</rights><rights>2011 Elsevier Ireland Ltd</rights><rights>2015 INIST-CNRS</rights><rights>Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c518t-af6f80bb1da44f215213d88f3316a79a33769f297fa22b0aa0c74eda28a4ba9b3</citedby><cites>FETCH-LOGICAL-c518t-af6f80bb1da44f215213d88f3316a79a33769f297fa22b0aa0c74eda28a4ba9b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.cmpb.2011.06.008$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,27922,27923,45993</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=26016280$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21908068$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Abella, M</creatorcontrib><creatorcontrib>Vaquero, J.J</creatorcontrib><creatorcontrib>Sisniega, A</creatorcontrib><creatorcontrib>Pascau, J</creatorcontrib><creatorcontrib>Udías, A</creatorcontrib><creatorcontrib>García, V</creatorcontrib><creatorcontrib>Vidal, I</creatorcontrib><creatorcontrib>Desco, M</creatorcontrib><title>Software architecture for multi-bed FDK-based reconstruction in X-ray CT scanners</title><title>Computer methods and programs in biomedicine</title><addtitle>Comput Methods Programs Biomed</addtitle><description>Highlights ► Comprehensive software architecture for small-animal CT. ► Covers all the steps from the system calibration to the volume reconstruction. ► Strategies for calibration and artifact correction are discussed. ► Takes advantage of system symmetries and allows for parallel reconstruction.</description><subject>Algorithms</subject><subject>Animals</subject><subject>Biological and medical sciences</subject><subject>Cone-beam</subject><subject>CT artifacts</subject><subject>FDK</subject><subject>Internal Medicine</subject><subject>Medical sciences</subject><subject>Mice</subject><subject>Other</subject><subject>Radiographic Image Enhancement - methods</subject><subject>Radiographic Image Interpretation, Computer-Assisted - methods</subject><subject>Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects)</subject><subject>Reconstruction</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><subject>Software</subject><subject>Technology. Biomaterials. Equipments. Material. Instrumentation</subject><subject>Tomography, X-Ray Computed - methods</subject><subject>Tomography, X-Ray Computed - veterinary</subject><subject>Whole Body Imaging - methods</subject><subject>Whole Body Imaging - veterinary</subject><subject>X-ray computed tomography</subject><issn>0169-2607</issn><issn>1872-7565</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqNklGL1DAQx4Mo3t7pF_BB-iL40jpJ2jQFEWS9U_FA5E7wLUzTBLO26V6SKvvtTdlVwQfxKQn85p_hN0PIEwoVBSpe7Co97fuKAaUViApA3iMbKltWto1o7pNNhrqSCWjPyHmMOwBgTSMekjNGO5Ag5IZ8uplt-oHBFBj0V5eMTkt-2DkU0zImV_ZmKK7efCh7jPkWjJ59TGHRyc2-cL74UgY8FNvbImr03oT4iDywOEbz-HRekM9Xl7fbd-X1x7fvt6-vS91QmUq0wkroezpgXVtGG0b5IKXlnApsO-S8FZ1lXWuRsR4QQbe1GZBJrHvsen5Bnh9z92G-W0xManJRm3FEb-YlKgq8lkxmK_-BMoCGcg4ZZUdUhznGYKzaBzdhOGRIrdbVTq3W1WpdgVDH_Ken_KWfzPC75JfmDDw7AZg1jTag1y7-4UQOzq1m7uWRM1ncd2eCitoZr83gsvmkhtn9u49Xf5Xr0XmXf_xmDibu5iX4PBJFVWQK1M26H-t6UApAWy75T2aZs7Y</recordid><startdate>20120801</startdate><enddate>20120801</enddate><creator>Abella, M</creator><creator>Vaquero, J.J</creator><creator>Sisniega, A</creator><creator>Pascau, J</creator><creator>Udías, A</creator><creator>García, V</creator><creator>Vidal, I</creator><creator>Desco, M</creator><general>Elsevier Ireland Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope></search><sort><creationdate>20120801</creationdate><title>Software architecture for multi-bed FDK-based reconstruction in X-ray CT scanners</title><author>Abella, M ; Vaquero, J.J ; Sisniega, A ; Pascau, J ; Udías, A ; García, V ; Vidal, I ; Desco, M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c518t-af6f80bb1da44f215213d88f3316a79a33769f297fa22b0aa0c74eda28a4ba9b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Algorithms</topic><topic>Animals</topic><topic>Biological and medical sciences</topic><topic>Cone-beam</topic><topic>CT artifacts</topic><topic>FDK</topic><topic>Internal Medicine</topic><topic>Medical sciences</topic><topic>Mice</topic><topic>Other</topic><topic>Radiographic Image Enhancement - methods</topic><topic>Radiographic Image Interpretation, Computer-Assisted - methods</topic><topic>Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects)</topic><topic>Reconstruction</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><topic>Software</topic><topic>Technology. Biomaterials. Equipments. Material. Instrumentation</topic><topic>Tomography, X-Ray Computed - methods</topic><topic>Tomography, X-Ray Computed - veterinary</topic><topic>Whole Body Imaging - methods</topic><topic>Whole Body Imaging - veterinary</topic><topic>X-ray computed tomography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Abella, M</creatorcontrib><creatorcontrib>Vaquero, J.J</creatorcontrib><creatorcontrib>Sisniega, A</creatorcontrib><creatorcontrib>Pascau, J</creatorcontrib><creatorcontrib>Udías, A</creatorcontrib><creatorcontrib>García, V</creatorcontrib><creatorcontrib>Vidal, I</creatorcontrib><creatorcontrib>Desco, M</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Computer methods and programs in biomedicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Abella, M</au><au>Vaquero, J.J</au><au>Sisniega, A</au><au>Pascau, J</au><au>Udías, A</au><au>García, V</au><au>Vidal, I</au><au>Desco, M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Software architecture for multi-bed FDK-based reconstruction in X-ray CT scanners</atitle><jtitle>Computer methods and programs in biomedicine</jtitle><addtitle>Comput Methods Programs Biomed</addtitle><date>2012-08-01</date><risdate>2012</risdate><volume>107</volume><issue>2</issue><spage>218</spage><epage>232</epage><pages>218-232</pages><issn>0169-2607</issn><eissn>1872-7565</eissn><abstract>Highlights ► Comprehensive software architecture for small-animal CT. ► Covers all the steps from the system calibration to the volume reconstruction. ► Strategies for calibration and artifact correction are discussed. ► Takes advantage of system symmetries and allows for parallel reconstruction.</abstract><cop>Kidlington</cop><pub>Elsevier Ireland Ltd</pub><pmid>21908068</pmid><doi>10.1016/j.cmpb.2011.06.008</doi><tpages>15</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0169-2607
ispartof Computer methods and programs in biomedicine, 2012-08, Vol.107 (2), p.218-232
issn 0169-2607
1872-7565
language eng
recordid cdi_proquest_miscellaneous_1034828008
source MEDLINE; ScienceDirect Journals (5 years ago - present)
subjects Algorithms
Animals
Biological and medical sciences
Cone-beam
CT artifacts
FDK
Internal Medicine
Medical sciences
Mice
Other
Radiographic Image Enhancement - methods
Radiographic Image Interpretation, Computer-Assisted - methods
Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects)
Reconstruction
Reproducibility of Results
Sensitivity and Specificity
Software
Technology. Biomaterials. Equipments. Material. Instrumentation
Tomography, X-Ray Computed - methods
Tomography, X-Ray Computed - veterinary
Whole Body Imaging - methods
Whole Body Imaging - veterinary
X-ray computed tomography
title Software architecture for multi-bed FDK-based reconstruction in X-ray CT scanners
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T00%3A37%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Software%20architecture%20for%20multi-bed%20FDK-based%20reconstruction%20in%20X-ray%20CT%20scanners&rft.jtitle=Computer%20methods%20and%20programs%20in%20biomedicine&rft.au=Abella,%20M&rft.date=2012-08-01&rft.volume=107&rft.issue=2&rft.spage=218&rft.epage=232&rft.pages=218-232&rft.issn=0169-2607&rft.eissn=1872-7565&rft_id=info:doi/10.1016/j.cmpb.2011.06.008&rft_dat=%3Cproquest_cross%3E1020051330%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1020051330&rft_id=info:pmid/21908068&rft_els_id=S0169260711001738&rfr_iscdi=true