A moribund athlete
Cardiac catheterisation was done to exclude coronary artery disease, and an intra-aortic balloon pump was placed for circulatory support. Central veno-arterial extracorporeal membrane oxygenation (ECMO) was established; a cannula was inserted via the abdominal wall into the right atrium to drain sys...
Gespeichert in:
Veröffentlicht in: | The Lancet (British edition) 2012-07, Vol.380 (9836), p.74-74 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Cardiac catheterisation was done to exclude coronary artery disease, and an intra-aortic balloon pump was placed for circulatory support. Central veno-arterial extracorporeal membrane oxygenation (ECMO) was established; a cannula was inserted via the abdominal wall into the right atrium to drain systemic venous blood into the ECMO pump, which returned oxygenated blood via a separate cannula into the ascending aorta (figure). |
---|---|