Patient dose measurements in diagnostic radiology procedures in Montenegro

It was the aim of the study presented here to estimate for the first time patient dose levels in conventional diagnostic radiology in Montenegro. Measurements of patient dose in terms of entrance surface air kerma (ESAK) and kerma-area product (KAP) were performed on at least 10 patients for each ex...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiation protection dosimetry 2012-05, Vol.149 (4), p.454-463
Hauptverfasser: Milatovic, A., Ciraj-Bjelac, O., Ivanovic, S., Jovanovic, S., Spasic-Jokic, V.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 463
container_issue 4
container_start_page 454
container_title Radiation protection dosimetry
container_volume 149
creator Milatovic, A.
Ciraj-Bjelac, O.
Ivanovic, S.
Jovanovic, S.
Spasic-Jokic, V.
description It was the aim of the study presented here to estimate for the first time patient dose levels in conventional diagnostic radiology in Montenegro. Measurements of patient dose in terms of entrance surface air kerma (ESAK) and kerma-area product (KAP) were performed on at least 10 patients for each examination type, in each of five randomly selected health institutions in Montenegro, so that a total of 872 patients for 16 different examination categories were included in the survey (817 patients for 1049 radiographies and 55 fluoroscopy patients). Exposure settings and individual data were recorded for each patient. Mean, median and third quartile values ESAK of patient doses are reported. The estimated mean ESAK values obtained are as follows: 4.7 mGy for pelvis anteroposterior (AP), 4.5 mGy for lumbar spine AP, 7.8 mGy for lumbar spine lateral (LAT), 3.1 mGy for thoracic spine AP and 4.3 mGy for thoracic spine LAT. When compared with the European diagnostic reference values, the mean ESAK for all studied examination types are found to be below the reference levels, except in chest radiography. Mean ESAK values for chest radiography are 0.9 mGy for posteroanterior (PA) projection and 2.0 mGy for LAT. The results exhibit a wide range of variation. For fluoroscopy examinations, the total KAP was measured. The mean KAP value per procedure for barium meal is found to be 22 Gy cm(2), 41 Gy cm(2) for barium enema and 19 Gy cm(2) for intravenous urography. Broad dose ranges for the same types of examinations indicate the necessity of applying practice optimisation in diagnostic radiology and establishment of national diagnostic reference levels.
doi_str_mv 10.1093/rpd/ncr317
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1020854962</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1013921922</sourcerecordid><originalsourceid>FETCH-LOGICAL-c320t-aa0955574dcd35bca0b9309394058d6e86dfd3ef7e992e1b1dd032b4b87fda093</originalsourceid><addsrcrecordid>eNqN0D1PwzAQBmALgWgpLPwAlBEhhfozjkdUlS8VwQBz5NiXKiixi50M_fe4tDAznXR67nT3InRJ8C3Bis3Dxs6dCYzIIzQlktOccVwcoykmnOclp3iCzmL8xJhKJfgpmlAipUh-ip7f9NCCGzLrI2Q96DgG6FMjZq3LbKvXzsehNVnQtvWdX2-zTfAGbGI_5MW7ARysgz9HJ43uIlwc6gx93C_fF4_56vXhaXG3yg2jeMi1xkoIIbk1lonaaFwrlt5QHIvSFlAWtrEMGglKUSA1sRYzWvO6lI1Ns2yGrvd70yFfI8Sh6ttooOu0Az_GimCKS8FVQf9BCVOUKLqjN3tqgo8xQFNtQtvrsE2o2sVcpZirfcwJXx32jnUP9o_-5sq-AV1uedY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1013921922</pqid></control><display><type>article</type><title>Patient dose measurements in diagnostic radiology procedures in Montenegro</title><source>MEDLINE</source><source>Oxford University Press Journals All Titles (1996-Current)</source><source>Alma/SFX Local Collection</source><creator>Milatovic, A. ; Ciraj-Bjelac, O. ; Ivanovic, S. ; Jovanovic, S. ; Spasic-Jokic, V.</creator><creatorcontrib>Milatovic, A. ; Ciraj-Bjelac, O. ; Ivanovic, S. ; Jovanovic, S. ; Spasic-Jokic, V.</creatorcontrib><description>It was the aim of the study presented here to estimate for the first time patient dose levels in conventional diagnostic radiology in Montenegro. Measurements of patient dose in terms of entrance surface air kerma (ESAK) and kerma-area product (KAP) were performed on at least 10 patients for each examination type, in each of five randomly selected health institutions in Montenegro, so that a total of 872 patients for 16 different examination categories were included in the survey (817 patients for 1049 radiographies and 55 fluoroscopy patients). Exposure settings and individual data were recorded for each patient. Mean, median and third quartile values ESAK of patient doses are reported. The estimated mean ESAK values obtained are as follows: 4.7 mGy for pelvis anteroposterior (AP), 4.5 mGy for lumbar spine AP, 7.8 mGy for lumbar spine lateral (LAT), 3.1 mGy for thoracic spine AP and 4.3 mGy for thoracic spine LAT. When compared with the European diagnostic reference values, the mean ESAK for all studied examination types are found to be below the reference levels, except in chest radiography. Mean ESAK values for chest radiography are 0.9 mGy for posteroanterior (PA) projection and 2.0 mGy for LAT. The results exhibit a wide range of variation. For fluoroscopy examinations, the total KAP was measured. The mean KAP value per procedure for barium meal is found to be 22 Gy cm(2), 41 Gy cm(2) for barium enema and 19 Gy cm(2) for intravenous urography. Broad dose ranges for the same types of examinations indicate the necessity of applying practice optimisation in diagnostic radiology and establishment of national diagnostic reference levels.</description><identifier>ISSN: 0144-8420</identifier><identifier>EISSN: 1742-3406</identifier><identifier>DOI: 10.1093/rpd/ncr317</identifier><identifier>PMID: 21775317</identifier><language>eng</language><publisher>England</publisher><subject>Adult ; Aged ; Aged, 80 and over ; Barium ; Data Collection ; Dosimetry ; Female ; Fluoroscopy - methods ; Humans ; Lumbar Vertebrae - radiation effects ; Male ; Middle Aged ; Montenegro ; Radiation Dosage ; Radiation Monitoring - methods ; Radiography ; Radiography - methods ; Radiography, Thoracic ; Radiology ; Reference Values ; spine ; Thoracic Vertebrae - radiation effects</subject><ispartof>Radiation protection dosimetry, 2012-05, Vol.149 (4), p.454-463</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c320t-aa0955574dcd35bca0b9309394058d6e86dfd3ef7e992e1b1dd032b4b87fda093</citedby><cites>FETCH-LOGICAL-c320t-aa0955574dcd35bca0b9309394058d6e86dfd3ef7e992e1b1dd032b4b87fda093</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21775317$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Milatovic, A.</creatorcontrib><creatorcontrib>Ciraj-Bjelac, O.</creatorcontrib><creatorcontrib>Ivanovic, S.</creatorcontrib><creatorcontrib>Jovanovic, S.</creatorcontrib><creatorcontrib>Spasic-Jokic, V.</creatorcontrib><title>Patient dose measurements in diagnostic radiology procedures in Montenegro</title><title>Radiation protection dosimetry</title><addtitle>Radiat Prot Dosimetry</addtitle><description>It was the aim of the study presented here to estimate for the first time patient dose levels in conventional diagnostic radiology in Montenegro. Measurements of patient dose in terms of entrance surface air kerma (ESAK) and kerma-area product (KAP) were performed on at least 10 patients for each examination type, in each of five randomly selected health institutions in Montenegro, so that a total of 872 patients for 16 different examination categories were included in the survey (817 patients for 1049 radiographies and 55 fluoroscopy patients). Exposure settings and individual data were recorded for each patient. Mean, median and third quartile values ESAK of patient doses are reported. The estimated mean ESAK values obtained are as follows: 4.7 mGy for pelvis anteroposterior (AP), 4.5 mGy for lumbar spine AP, 7.8 mGy for lumbar spine lateral (LAT), 3.1 mGy for thoracic spine AP and 4.3 mGy for thoracic spine LAT. When compared with the European diagnostic reference values, the mean ESAK for all studied examination types are found to be below the reference levels, except in chest radiography. Mean ESAK values for chest radiography are 0.9 mGy for posteroanterior (PA) projection and 2.0 mGy for LAT. The results exhibit a wide range of variation. For fluoroscopy examinations, the total KAP was measured. The mean KAP value per procedure for barium meal is found to be 22 Gy cm(2), 41 Gy cm(2) for barium enema and 19 Gy cm(2) for intravenous urography. Broad dose ranges for the same types of examinations indicate the necessity of applying practice optimisation in diagnostic radiology and establishment of national diagnostic reference levels.</description><subject>Adult</subject><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Barium</subject><subject>Data Collection</subject><subject>Dosimetry</subject><subject>Female</subject><subject>Fluoroscopy - methods</subject><subject>Humans</subject><subject>Lumbar Vertebrae - radiation effects</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Montenegro</subject><subject>Radiation Dosage</subject><subject>Radiation Monitoring - methods</subject><subject>Radiography</subject><subject>Radiography - methods</subject><subject>Radiography, Thoracic</subject><subject>Radiology</subject><subject>Reference Values</subject><subject>spine</subject><subject>Thoracic Vertebrae - radiation effects</subject><issn>0144-8420</issn><issn>1742-3406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqN0D1PwzAQBmALgWgpLPwAlBEhhfozjkdUlS8VwQBz5NiXKiixi50M_fe4tDAznXR67nT3InRJ8C3Bis3Dxs6dCYzIIzQlktOccVwcoykmnOclp3iCzmL8xJhKJfgpmlAipUh-ip7f9NCCGzLrI2Q96DgG6FMjZq3LbKvXzsehNVnQtvWdX2-zTfAGbGI_5MW7ARysgz9HJ43uIlwc6gx93C_fF4_56vXhaXG3yg2jeMi1xkoIIbk1lonaaFwrlt5QHIvSFlAWtrEMGglKUSA1sRYzWvO6lI1Ns2yGrvd70yFfI8Sh6ttooOu0Az_GimCKS8FVQf9BCVOUKLqjN3tqgo8xQFNtQtvrsE2o2sVcpZirfcwJXx32jnUP9o_-5sq-AV1uedY</recordid><startdate>20120501</startdate><enddate>20120501</enddate><creator>Milatovic, A.</creator><creator>Ciraj-Bjelac, O.</creator><creator>Ivanovic, S.</creator><creator>Jovanovic, S.</creator><creator>Spasic-Jokic, V.</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope></search><sort><creationdate>20120501</creationdate><title>Patient dose measurements in diagnostic radiology procedures in Montenegro</title><author>Milatovic, A. ; Ciraj-Bjelac, O. ; Ivanovic, S. ; Jovanovic, S. ; Spasic-Jokic, V.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c320t-aa0955574dcd35bca0b9309394058d6e86dfd3ef7e992e1b1dd032b4b87fda093</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Barium</topic><topic>Data Collection</topic><topic>Dosimetry</topic><topic>Female</topic><topic>Fluoroscopy - methods</topic><topic>Humans</topic><topic>Lumbar Vertebrae - radiation effects</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Montenegro</topic><topic>Radiation Dosage</topic><topic>Radiation Monitoring - methods</topic><topic>Radiography</topic><topic>Radiography - methods</topic><topic>Radiography, Thoracic</topic><topic>Radiology</topic><topic>Reference Values</topic><topic>spine</topic><topic>Thoracic Vertebrae - radiation effects</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Milatovic, A.</creatorcontrib><creatorcontrib>Ciraj-Bjelac, O.</creatorcontrib><creatorcontrib>Ivanovic, S.</creatorcontrib><creatorcontrib>Jovanovic, S.</creatorcontrib><creatorcontrib>Spasic-Jokic, V.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><jtitle>Radiation protection dosimetry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Milatovic, A.</au><au>Ciraj-Bjelac, O.</au><au>Ivanovic, S.</au><au>Jovanovic, S.</au><au>Spasic-Jokic, V.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Patient dose measurements in diagnostic radiology procedures in Montenegro</atitle><jtitle>Radiation protection dosimetry</jtitle><addtitle>Radiat Prot Dosimetry</addtitle><date>2012-05-01</date><risdate>2012</risdate><volume>149</volume><issue>4</issue><spage>454</spage><epage>463</epage><pages>454-463</pages><issn>0144-8420</issn><eissn>1742-3406</eissn><abstract>It was the aim of the study presented here to estimate for the first time patient dose levels in conventional diagnostic radiology in Montenegro. Measurements of patient dose in terms of entrance surface air kerma (ESAK) and kerma-area product (KAP) were performed on at least 10 patients for each examination type, in each of five randomly selected health institutions in Montenegro, so that a total of 872 patients for 16 different examination categories were included in the survey (817 patients for 1049 radiographies and 55 fluoroscopy patients). Exposure settings and individual data were recorded for each patient. Mean, median and third quartile values ESAK of patient doses are reported. The estimated mean ESAK values obtained are as follows: 4.7 mGy for pelvis anteroposterior (AP), 4.5 mGy for lumbar spine AP, 7.8 mGy for lumbar spine lateral (LAT), 3.1 mGy for thoracic spine AP and 4.3 mGy for thoracic spine LAT. When compared with the European diagnostic reference values, the mean ESAK for all studied examination types are found to be below the reference levels, except in chest radiography. Mean ESAK values for chest radiography are 0.9 mGy for posteroanterior (PA) projection and 2.0 mGy for LAT. The results exhibit a wide range of variation. For fluoroscopy examinations, the total KAP was measured. The mean KAP value per procedure for barium meal is found to be 22 Gy cm(2), 41 Gy cm(2) for barium enema and 19 Gy cm(2) for intravenous urography. Broad dose ranges for the same types of examinations indicate the necessity of applying practice optimisation in diagnostic radiology and establishment of national diagnostic reference levels.</abstract><cop>England</cop><pmid>21775317</pmid><doi>10.1093/rpd/ncr317</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0144-8420
ispartof Radiation protection dosimetry, 2012-05, Vol.149 (4), p.454-463
issn 0144-8420
1742-3406
language eng
recordid cdi_proquest_miscellaneous_1020854962
source MEDLINE; Oxford University Press Journals All Titles (1996-Current); Alma/SFX Local Collection
subjects Adult
Aged
Aged, 80 and over
Barium
Data Collection
Dosimetry
Female
Fluoroscopy - methods
Humans
Lumbar Vertebrae - radiation effects
Male
Middle Aged
Montenegro
Radiation Dosage
Radiation Monitoring - methods
Radiography
Radiography - methods
Radiography, Thoracic
Radiology
Reference Values
spine
Thoracic Vertebrae - radiation effects
title Patient dose measurements in diagnostic radiology procedures in Montenegro
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T05%3A09%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Patient%20dose%20measurements%20in%20diagnostic%20radiology%20procedures%20in%20Montenegro&rft.jtitle=Radiation%20protection%20dosimetry&rft.au=Milatovic,%20A.&rft.date=2012-05-01&rft.volume=149&rft.issue=4&rft.spage=454&rft.epage=463&rft.pages=454-463&rft.issn=0144-8420&rft.eissn=1742-3406&rft_id=info:doi/10.1093/rpd/ncr317&rft_dat=%3Cproquest_cross%3E1013921922%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1013921922&rft_id=info:pmid/21775317&rfr_iscdi=true