Development of weighting factors for climate variables for selecting the energy reference year according to the EN ISO 15927-4 standard

This paper presents a new method for selecting the energy reference year, which may be used for many applications, such as the energy performance of buildings, the simulation of active or passive solar energy systems, HVAC system performance or indoor climate analyses. The EN ISO 15927-4 method was...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Energy and buildings 2012-04, Vol.47, p.53-60
Hauptverfasser: KALAMEES, Targo, JYLHÄ, Kirsti, TIETÄVÄINEN, Hanna, JOKISALO, Juha, ILOMETS, Simo, HYVÖNEN, Reijo, SAKU, Seppo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 60
container_issue
container_start_page 53
container_title Energy and buildings
container_volume 47
creator KALAMEES, Targo
JYLHÄ, Kirsti
TIETÄVÄINEN, Hanna
JOKISALO, Juha
ILOMETS, Simo
HYVÖNEN, Reijo
SAKU, Seppo
description This paper presents a new method for selecting the energy reference year, which may be used for many applications, such as the energy performance of buildings, the simulation of active or passive solar energy systems, HVAC system performance or indoor climate analyses. The EN ISO 15927-4 method was modified by using monthly dependent weighting factors for the main climatic parameters in the calculation of heating and cooling energy demand in buildings. We used data from the cold Finnish boreal climate to demonstrate the method. In a cold boreal climate, during the summer temperature and solar radiation have a similar influence on heating and cooling energy demand, whereas air humidity and wind speed have a minor effect. The principle for determining the weighting factors and modified method for the selection of the energy reference year can also be used for other climatic zones. The weighting factors determined in this study can be used for other countries in a cold climatic area.
doi_str_mv 10.1016/j.enbuild.2011.11.031
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1019650575</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1019650575</sourcerecordid><originalsourceid>FETCH-LOGICAL-c382t-c52711c3e29328c0bdb290e8d1ab31ad600445e150f7ed9dd132bd4e7d09ab033</originalsourceid><addsrcrecordid>eNo9kM9KAzEQh_egYK0-gpCL4GVrJtlsdo9SqxaKPajnJZvMtlvSTU22lT6Br236B2FgYPh-M8yXJHdAR0Ahf1yNsKu3rTUjRgFGsSiHi2RAuSxSKYviKrkOYUUpzYWEQfL7jDu0brPGrieuIT_YLpZ92y1Io3TvfCCN80Tbdq16JDvlW1VbPE0DWtRHtl8iwQ79Yk88Nuix00j2qDxRWjtvjow7YpN3Mv2YExAlk2lGQq86o7y5SS4bZQPenvsw-XqZfI7f0tn8dTp-mqWaF6xPtWASQHNkJWeFprWpWUmxMKBqDsrklGaZQBC0kWhKY4Cz2mQoDS1VTTkfJg-nvRvvvrcY-mrdBo3Wqg7dNlRRYpkLKqSIqDih2rsQ4l_VxkcNfh-hA5dXq-osuzrIrmJF2TF3fz6hgla28arTbfgPM5FnOQDwP1tphOc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1019650575</pqid></control><display><type>article</type><title>Development of weighting factors for climate variables for selecting the energy reference year according to the EN ISO 15927-4 standard</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>KALAMEES, Targo ; JYLHÄ, Kirsti ; TIETÄVÄINEN, Hanna ; JOKISALO, Juha ; ILOMETS, Simo ; HYVÖNEN, Reijo ; SAKU, Seppo</creator><creatorcontrib>KALAMEES, Targo ; JYLHÄ, Kirsti ; TIETÄVÄINEN, Hanna ; JOKISALO, Juha ; ILOMETS, Simo ; HYVÖNEN, Reijo ; SAKU, Seppo</creatorcontrib><description>This paper presents a new method for selecting the energy reference year, which may be used for many applications, such as the energy performance of buildings, the simulation of active or passive solar energy systems, HVAC system performance or indoor climate analyses. The EN ISO 15927-4 method was modified by using monthly dependent weighting factors for the main climatic parameters in the calculation of heating and cooling energy demand in buildings. We used data from the cold Finnish boreal climate to demonstrate the method. In a cold boreal climate, during the summer temperature and solar radiation have a similar influence on heating and cooling energy demand, whereas air humidity and wind speed have a minor effect. The principle for determining the weighting factors and modified method for the selection of the energy reference year can also be used for other climatic zones. The weighting factors determined in this study can be used for other countries in a cold climatic area.</description><identifier>ISSN: 0378-7788</identifier><identifier>DOI: 10.1016/j.enbuild.2011.11.031</identifier><identifier>CODEN: ENEBDR</identifier><language>eng</language><publisher>Oxford: Elsevier</publisher><subject>Applied sciences ; Building technical equipments ; Buildings ; Buildings. Public works ; Computation methods. Tables. Charts ; Energy management and energy conservation in building ; Environmental engineering ; Exact sciences and technology ; Structural analysis. Stresses</subject><ispartof>Energy and buildings, 2012-04, Vol.47, p.53-60</ispartof><rights>2014 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c382t-c52711c3e29328c0bdb290e8d1ab31ad600445e150f7ed9dd132bd4e7d09ab033</citedby><cites>FETCH-LOGICAL-c382t-c52711c3e29328c0bdb290e8d1ab31ad600445e150f7ed9dd132bd4e7d09ab033</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=25646111$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>KALAMEES, Targo</creatorcontrib><creatorcontrib>JYLHÄ, Kirsti</creatorcontrib><creatorcontrib>TIETÄVÄINEN, Hanna</creatorcontrib><creatorcontrib>JOKISALO, Juha</creatorcontrib><creatorcontrib>ILOMETS, Simo</creatorcontrib><creatorcontrib>HYVÖNEN, Reijo</creatorcontrib><creatorcontrib>SAKU, Seppo</creatorcontrib><title>Development of weighting factors for climate variables for selecting the energy reference year according to the EN ISO 15927-4 standard</title><title>Energy and buildings</title><description>This paper presents a new method for selecting the energy reference year, which may be used for many applications, such as the energy performance of buildings, the simulation of active or passive solar energy systems, HVAC system performance or indoor climate analyses. The EN ISO 15927-4 method was modified by using monthly dependent weighting factors for the main climatic parameters in the calculation of heating and cooling energy demand in buildings. We used data from the cold Finnish boreal climate to demonstrate the method. In a cold boreal climate, during the summer temperature and solar radiation have a similar influence on heating and cooling energy demand, whereas air humidity and wind speed have a minor effect. The principle for determining the weighting factors and modified method for the selection of the energy reference year can also be used for other climatic zones. The weighting factors determined in this study can be used for other countries in a cold climatic area.</description><subject>Applied sciences</subject><subject>Building technical equipments</subject><subject>Buildings</subject><subject>Buildings. Public works</subject><subject>Computation methods. Tables. Charts</subject><subject>Energy management and energy conservation in building</subject><subject>Environmental engineering</subject><subject>Exact sciences and technology</subject><subject>Structural analysis. Stresses</subject><issn>0378-7788</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNo9kM9KAzEQh_egYK0-gpCL4GVrJtlsdo9SqxaKPajnJZvMtlvSTU22lT6Br236B2FgYPh-M8yXJHdAR0Ahf1yNsKu3rTUjRgFGsSiHi2RAuSxSKYviKrkOYUUpzYWEQfL7jDu0brPGrieuIT_YLpZ92y1Io3TvfCCN80Tbdq16JDvlW1VbPE0DWtRHtl8iwQ79Yk88Nuix00j2qDxRWjtvjow7YpN3Mv2YExAlk2lGQq86o7y5SS4bZQPenvsw-XqZfI7f0tn8dTp-mqWaF6xPtWASQHNkJWeFprWpWUmxMKBqDsrklGaZQBC0kWhKY4Cz2mQoDS1VTTkfJg-nvRvvvrcY-mrdBo3Wqg7dNlRRYpkLKqSIqDih2rsQ4l_VxkcNfh-hA5dXq-osuzrIrmJF2TF3fz6hgla28arTbfgPM5FnOQDwP1tphOc</recordid><startdate>20120401</startdate><enddate>20120401</enddate><creator>KALAMEES, Targo</creator><creator>JYLHÄ, Kirsti</creator><creator>TIETÄVÄINEN, Hanna</creator><creator>JOKISALO, Juha</creator><creator>ILOMETS, Simo</creator><creator>HYVÖNEN, Reijo</creator><creator>SAKU, Seppo</creator><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>7U6</scope><scope>C1K</scope></search><sort><creationdate>20120401</creationdate><title>Development of weighting factors for climate variables for selecting the energy reference year according to the EN ISO 15927-4 standard</title><author>KALAMEES, Targo ; JYLHÄ, Kirsti ; TIETÄVÄINEN, Hanna ; JOKISALO, Juha ; ILOMETS, Simo ; HYVÖNEN, Reijo ; SAKU, Seppo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c382t-c52711c3e29328c0bdb290e8d1ab31ad600445e150f7ed9dd132bd4e7d09ab033</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Applied sciences</topic><topic>Building technical equipments</topic><topic>Buildings</topic><topic>Buildings. Public works</topic><topic>Computation methods. Tables. Charts</topic><topic>Energy management and energy conservation in building</topic><topic>Environmental engineering</topic><topic>Exact sciences and technology</topic><topic>Structural analysis. Stresses</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>KALAMEES, Targo</creatorcontrib><creatorcontrib>JYLHÄ, Kirsti</creatorcontrib><creatorcontrib>TIETÄVÄINEN, Hanna</creatorcontrib><creatorcontrib>JOKISALO, Juha</creatorcontrib><creatorcontrib>ILOMETS, Simo</creatorcontrib><creatorcontrib>HYVÖNEN, Reijo</creatorcontrib><creatorcontrib>SAKU, Seppo</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Sustainability Science Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><jtitle>Energy and buildings</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>KALAMEES, Targo</au><au>JYLHÄ, Kirsti</au><au>TIETÄVÄINEN, Hanna</au><au>JOKISALO, Juha</au><au>ILOMETS, Simo</au><au>HYVÖNEN, Reijo</au><au>SAKU, Seppo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of weighting factors for climate variables for selecting the energy reference year according to the EN ISO 15927-4 standard</atitle><jtitle>Energy and buildings</jtitle><date>2012-04-01</date><risdate>2012</risdate><volume>47</volume><spage>53</spage><epage>60</epage><pages>53-60</pages><issn>0378-7788</issn><coden>ENEBDR</coden><abstract>This paper presents a new method for selecting the energy reference year, which may be used for many applications, such as the energy performance of buildings, the simulation of active or passive solar energy systems, HVAC system performance or indoor climate analyses. The EN ISO 15927-4 method was modified by using monthly dependent weighting factors for the main climatic parameters in the calculation of heating and cooling energy demand in buildings. We used data from the cold Finnish boreal climate to demonstrate the method. In a cold boreal climate, during the summer temperature and solar radiation have a similar influence on heating and cooling energy demand, whereas air humidity and wind speed have a minor effect. The principle for determining the weighting factors and modified method for the selection of the energy reference year can also be used for other climatic zones. The weighting factors determined in this study can be used for other countries in a cold climatic area.</abstract><cop>Oxford</cop><pub>Elsevier</pub><doi>10.1016/j.enbuild.2011.11.031</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0378-7788
ispartof Energy and buildings, 2012-04, Vol.47, p.53-60
issn 0378-7788
language eng
recordid cdi_proquest_miscellaneous_1019650575
source ScienceDirect Journals (5 years ago - present)
subjects Applied sciences
Building technical equipments
Buildings
Buildings. Public works
Computation methods. Tables. Charts
Energy management and energy conservation in building
Environmental engineering
Exact sciences and technology
Structural analysis. Stresses
title Development of weighting factors for climate variables for selecting the energy reference year according to the EN ISO 15927-4 standard
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T06%3A55%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20weighting%20factors%20for%20climate%20variables%20for%20selecting%20the%20energy%20reference%20year%20according%20to%20the%20EN%20ISO%2015927-4%20standard&rft.jtitle=Energy%20and%20buildings&rft.au=KALAMEES,%20Targo&rft.date=2012-04-01&rft.volume=47&rft.spage=53&rft.epage=60&rft.pages=53-60&rft.issn=0378-7788&rft.coden=ENEBDR&rft_id=info:doi/10.1016/j.enbuild.2011.11.031&rft_dat=%3Cproquest_cross%3E1019650575%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1019650575&rft_id=info:pmid/&rfr_iscdi=true