Assessment of pituitary adenoma volumetric change using longitudinal MR image registration
Introduction Change detection is a crucial factor in monitoring of slowly evolving pathologies. The objective of the study was to test a semi-automatic method applied on longitudinal MRI monitoring of volume change in pituitary macroadenomas. Methods The proposed method is based on a visual comparis...
Gespeichert in:
Veröffentlicht in: | Neuroradiology 2012-05, Vol.54 (5), p.435-443 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Introduction
Change detection is a crucial factor in monitoring of slowly evolving pathologies. The objective of the study was to test a semi-automatic method applied on longitudinal MRI monitoring of volume change in pituitary macroadenomas.
Methods
The proposed method is based on a visual comparison of geometrically corrected, co-registered, intensity-normalized contrast-enhanced (CE) 3D GRE T1-weighted images. Qualitative volume changes based on this applied method were compared with experts’ readings of conventional pre- and post-CE 2D T1-weighted images. Magnetic resonance (MR) imaging was performed two to four times in 13 patients with a total combination of 29 time points.
Results
Compared to conventional 2D MR readings, a diagnosis of tumor growth (yes/no) was changed in 5 of 13 patients (38%) at 9 of the 29 combinations of time points (31%) using the 3D-based semi-automatic method. With manual tumor tracings as reference, McNemar’s test showed a significant difference between the two methods.
Conclusion
Visual comparison of geometrically corrected, intensity-normalized, and affine-aligned longitudinal 3D images may enable more accurate assessment of qualitative volumetric change in pituitary adenomas than conventional reading of 2D images. |
---|---|
ISSN: | 0028-3940 1432-1920 |
DOI: | 10.1007/s00234-011-0894-7 |